Get support for Fluke 381

Fluke 381 Support Question

Fluke 381 Support Question

Find answers below for this question about Fluke 381.
Need a Fluke 381 manual? We have 2 online manuals for this item!
Question posted by Anonymous-164323 on March 3rd, 2018

Err Rf

I opened my meter to change batteries , when I put new ones in this is the error I got.

Current Answers

Answer #1: Posted by Schoolu2 on April 12th, 2018 10:54 AM
This answer was accepted by the poster of the original question.
Schoolu2

Member since:
April 12th, 2018

Points: 1,090
1,090
points
Be sure to replace the batteries in both the meter and the display. I had the same issue when I only replaced the display and not the meter also.

Related Fluke 381 Manual Pages

Fluke 381 Clamp Meter Product Datasheet - Page 1

Now one technician can do jobs that used to operate controls or remove protective equipment, all while watching real-time readings. The new iFlex™ flexible current probe (included... readings 381 Remote Display True-rms AC/DC Clamp Meter with iFlex™ The first clamp meter with a detachable, remote display for easier, faster, safer measurements Technical Data The new Fluke 381 does ...
Fluke 381 Clamp Meter Product Datasheet - Page 2

...change switch positions while taking a measurement • Three-year warranty • Soft carrying case Ordering information 381 Remote Display True-rms Clamp Meter with iFlex™ Specifications Fluke 381...; 5 digits 0.5 % ± 5 digits Included Accessory 750 MCM or 2-500 MCM CAT III 1000V, CAT IV 600V 2 Fluke Corporation 381 Remote Display True-rms AC/DC Clamp Meter with iFlex™
Fluke 381 Users Manual - Page 1

All rights reserved. Printed in China. Specifications are trademarks of their respective companies. All product names are subject to change without notice. 381 Remote Display True-rms Clamp Meter Users Manual PN 3538357 July 2010 © 2010 Fluke Corporation.
Fluke 381 Users Manual - Page 4

381 Users Manual Display...17 Measurements...19 AC and DC Current (Jaw 19 AC Current (Flexible Current Probe 22 AC and DC Voltage 23 Resistance/Continuity 26 Inrush Current Measurement (Jaw and Flexible Current Probe 26 Frequency Measurement (Jaw and Flexible Current Probe 28 Maintenance...28 Cleaning the Meter... and Flexible Current Probe 28 Battery Replacement 29 User-Replaceable ...
Fluke 381 Users Manual - Page 5

The Fluke 381 is a handheld, battery-operated Clamp Meter (the Meter) that traditional jawed meters cannot measure. This lets the display be removed from the measurement source. The Flexible Current Probe makes it possible to measure higher current (up to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800...
Fluke 381 Users Manual - Page 6

... and procedures that pose hazard(s) to the user; Symbols used on the Meter and in this manual or the protection provided by the Meter can be compromised. • Examine the case before the battery door is opened. 2 Carefully look at www.fluke.com. 381 Users Manual • Singapore: +65-738-5655 • Anywhere in Table...
Fluke 381 Users Manual - Page 8

...circuits carrying more than 1000 V or 1000 A with the Meter Jaw. • Never operate the Meter with the back cover removed or the case open. • Do not measure ac current in circuits carrying more... damage to the Meter or to prevent shock and arc blast injury where hazardous live conductors are exposed. • When measuring, keep fingers behind the Tactile Barrier. 381 Users Manual •...
Fluke 381 Users Manual - Page 10

...(CAT) and voltage rating of test probe, test probe accessory, current clamp accessory, and the Meter is permitted. Conforms to or remove from HAZARDOUS LIVE conductors...equipment installations, such as an electricity Meter or an overhead or underground utility service. ® Examined and licensed by TÜV Product Services. ; 381 Users Manual Symbol Meaning Symbol Meaning CAT...
Fluke 381 Users Manual - Page 12

...batteries from the Meter base and display module. It is possible for help. The display module is synchronized with a Meter base but, only one or more of the Meter is docked on the Meter base and turned on. Remote Display The Meter...radio signal does not hinder Meter measurements. 381 Users Manual off and on, the user is off when the display module is set to the Meter base. The term "IC...
Fluke 381 Users Manual - Page 14

... disable the Auto Power Off, hold down  while turning on again. If the Meter powers off if there is used for 20 minutes. Auto Power Off is at the Meter input. 381 Users Manual Hazardous Voltage Indicator When the Meter senses a voltage ±30 V or a voltage overload (OL), Y is shown on the display...
Fluke 381 Users Manual - Page 16

... readings. Current spikes from motor drives are not affected by low batteries in the Meter base should be changed . Low batteries on . The Meter can capture this surge current reading. When B appears, the batteries in the display. 12 Measurements are one example of such an event. 381 Users Manual Inrush Inrush Current is surge current that occurs when...
Fluke 381 Users Manual - Page 18

... maximum input. Hold L for 2 minutes when there is no button or switch interaction and then shuts off . 381 Users Manual Item A B C D E F G H I Table 2. This function works in current, voltage, and frequency modes. 14 Meter Features Description Current sensing Jaw Tactile Barrier Rotary Function Switch, see Table 3. With subsequent pushes, the minimum and the...
Fluke 381 Users Manual - Page 20

DC current AC current and frequency measurement using the Flexible Current Probe. Rotary Function Switch Meter is powered down AC voltage DC voltage Function Resistance and continuity AC current. Push Z to shift to frequency. 381 Users Manual Switch Position OFF K L K A C D Table 3. Push Z to shift to frequency. 16
Fluke 381 Users Manual - Page 22

Continuity Hazardous voltage is taken at the Jaw. 381 Users Manual Item A B Table 4. Measurement is present. Display Description Item Inrush is active H Hold is active I C Volts J D Amps K E Ohms, DC, AC, Hz L F Main display M G Remote display low-battery symbol N O Description Meter base low-battery symbol Measurement is being sent to remote display. Min, Max...
Fluke 381 Users Manual - Page 24

Open the Jaw by pressing the Jaw Release and insert the conductor into the clamp at a time. See Figure 4. Note Current flowing in opposite directions, place one conductor into the Jaw. 4. ...Function Switch to zero the Meter. 3. If measuring dc, wait for the display to stabilize and then push Z to the proper function. 381 Users Manual Note Before zeroing the Meter, make sure the Jaws are...
Fluke 381 Users Manual - Page 25

Current Measurement with Jaw ghn04.eps 21 CAT 1000 V CAT 600 V 1000 A Remote Display True-rms Clamp Meter Measurements 6C01A0C0TV0A0TV 381 TRRMEMS OCTLEAMDPISPMLEATYER iFlex 1000 A Figure 4.
Fluke 381 Users Manual - Page 26

... Current Probe. 22 D 4. You should be able to the Meter. Take special care during fitting and removal of the Flexible Current ...possible, avoid taking measurements close and latch it. If opening the end of the Flexible Current Probe to make ...energize the installation under test or wear suitable protective clothing. 381 Users Manual AC Current (Flexible Current Probe) XW Warning ...
Fluke 381 Users Manual - Page 30

...Meter Rotary Function Switch to the desired test points of the circuit. 5. If the resistance is < 30 Ω, continuity is open.... The inrush current (spike) is being tested. 3. To measure the inrush current: 1. Inrush Current Measurement (Jaw and Flexible Current Probe) The Meter...red test lead to K. 2. Push E on the Meter display. Turn the Rotary Function Switch to the G ...
Fluke 381 Users Manual - Page 33

...the display module, see Figure 8: 1. Slide the battery door back into place. 7. Dock the Display Module with three new AAA batteries. 5. Reattach the battery compartment door to open the battery compartment, 4. Replace the batteries with two new AAA batteries. 6. Remove the batteries. 4. To replace the batteries in the center of the Meter, remove the display module. 3. Turn the...
Fluke 381 Users Manual - Page 42

381 Users Manual Flexible Current Probe Cable Length (head to electronics connector 1.8 m Environmental Specifications Operating Temperature 10 °C to +50 °C Storage ...% RH (at 40 °C to 50 °C) (Without Condensation) Operating Altitude 2000 meters Storage Altitude 12,000 meters EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006 ETSI EN 300 489...

Similar Questions

I Am Getting An Rf Error, What Do I Do?
(Posted by bensalazar7164 1 year ago)
Fluke 381 Red Triangle
My fluke 381 stopped working it has new batteries but only the red triangle lights up
(Posted by tacevedo1018 3 years ago)
Fluke 233
Have a Fluke 233 remote display which has no display. Both set of batteries are good, but red warnin...
(Posted by remybreauxlsu1958 3 years ago)
Pantalla Remota Flete 381
Buenos días donde puedo conseguir la pantalla inalámbrica para la pinza amperica 381
(Posted by delossantos2577 3 years ago)
F8 Error Help
My Fluke 87V has error name F8 Error. I cant repair, i need your help now. Thanks.
(Posted by quycali 8 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 381 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.