EMC CX700 Support Question
Find answers below for this question about EMC CX700 - Insignia CLARiiON Hard Drive Array.Need a EMC CX700 manual? We have 1 online manual for this item!
Question posted by ernestmeyer on November 25th, 2012
Replacement Of The Standby Power Supply 078-000-085 For The Cx700 Storage Array.
I would like a step-by-step description of how to safely replace the SG6004 SPS unit in a CX700 storage unit. There are 2 product codes on the SPS : 100-809-017 and 078-000-085
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related EMC CX700 Manual Pages
Initialization Guide - Page 1
... or Host Connections 34 ◆ Configuring Your Host Server and Storage System 36
Only an authorized EMC service provider should perform the procedures described in this guide.
1 Topics include ◆ Initialization Overview 2 ◆ Requirements for the CLARiiON® CX300, CX500, and CX700 storage systems. An authorized EMC service provider will perform these procedures at...
Initialization Guide - Page 2
... to the SP LAN port (page 29).
❑ Install software options (page 30).
❑ Set initial security parameters (page 32).
5 Make Management and Switch or Host ❑ Connect a fibre-optic switch or Fibre Channel
Connections
host (page 34).
6 Configure Your Host Server and Storage System (page 36)
2
EMC CLARiiON CX300, CX500, and CX700 Initialization...
Initialization Guide - Page 3
...you can manage the storage systems from any server ...products.
❑ A NULL modem cable, with 9-pin, female-male to manage your storage... (supplied with each storage system).
❑ A crossover LAN cable (supplied with each storage system...storage systems, you will need the following:
General Requirements ❑ A CX700, CX500, or CX300 storage system with two storage
processors (SPs...
Initialization Guide - Page 5
...Setting 8 None 1 115200 baud
What Next? This is running, do one of the SP, as shown in Table 1.
Setting Up the Service Laptop
Setting Up the Service Laptop
The...configure the modem for the line characteristics of the following:
For Windows 2000 systems -
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
5 Refer to Setting Up the Dial-Up PPP Support (Windows 2000 Environment)...
Initialization Guide - Page 10
... dialog box, select the dialup networking serial cable with the correct COM port noted in step 1i. Double-click My Computer, then double-click Dial-Up Networking.
2.
and do...following: a.
Configure the serial connection for all the SPs you want to exit the Modem Configuration dialog box.
10
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide When prompted to reboot, click Yes....
Initialization Guide - Page 11
...Network dialog box, click the Identification tab. EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
11
c. Select the Use IP header ... select TCP/IP. 11. Click TCP/IP Settings... The SP will provide the address for the service laptop. b. Select...click Dial-Up
Networking. c. If it is ready to Initializing the Storage System on . 14. e. Click the Workgroup radio button, then ...
Initialization Guide - Page 12
... B
Hostname
Up to complete the system setup. YES____ NO____
12
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide Initializing the Storage System
Initializing the Storage System
This section describes how to set critical startup parameters on SP A and SP B to EMC-specific assigned value for the storage system, and complete the following worksheet.
IP Address
Subnet Mask...
Initialization Guide - Page 13
... in Figure 1. Be sure that you are starting with SP A.
The SP's power LED should be a steady green, and no amber LEDs should be blinking.
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
13 lOlOl
Service Laptop
RS-232 Cable
Figure 1 COM 1 to initialize the storage system from the service laptop. These instructions assume that the...
Initialization Guide - Page 15
Initializing the Storage System
Figure 2 Storage Processor Networking Configuration Setup Screen (SP A)
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
15
Initialization Guide - Page 16
... Processor Network Configuration confirmation screen.
16
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide Initializing the Storage System
5. Subnet Mask d.
After about 30 seconds, a confirmation screen opens, similar to the EMC Navisphere Version 6.X Security Administrator's Guide.
6. For a description of Navisphere 6.X security features, refer to the one in Figure...
Initialization Guide - Page 17
... laptop serial port (COM 1) and the SP B service port (|0|0|, or ).
9. In the Connect to dialog box, log in as user clariion with password clariion!. b. Click Connect and click OK on your... networking.
Depending on the Connection Complete dialog box.
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
17 Select the connection name that you assigned when you set up...
Initialization Guide - Page 19
Initializing the Storage System
Figure 4 Storage Processor Networking Configuration Setup Screen (SP B)
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
19
Initialization Guide - Page 20
... screen opens, similar to the one in step 12, and includes a message informing you want to manage the storage system. Specify the following for SP A f. CAUTION
Be sure that SP B is the management port whose setting you that this is rebooting.
20
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide If you can change the management...
Initialization Guide - Page 21
... SP ...Storage System
Figure 5
Network Configuration Confirmation Screen (SP B)
15. A Confirm: Navisphere Security dialog box opens indicating that global security is not initialized. On the service laptop, launch the Navisphere® Manager software (Management UI). EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
21 In most cases, you install the Navisphere software (see step...
Initialization Guide - Page 23
... using the arrows to scroll up and down. 22. Verify the date and time and click Yes, then OK on the success screen. Initializing the Storage System
Figure 7
SP B Properties
20. EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
23 A Confirm SP B: SP Properties dialog box opens. 23.
Click the General tab. 21.
Initialization Guide - Page 24
Figure 8 Setting the Port Speed
24
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
When you will be connected.
In the SP Properties screen, click the Fibre Speed tab, as shown in Figure 8. (If you have a CX500 or CX300 storage system, you set the port speed, match it to the device to 1 or 2 gigabits/second...
Initialization Guide - Page 25
... 2000
a.
See Figure 9. 27. In the Connect to dialog box, log in as user clariion with password clariion!. Confirm the IP Address, Gateway and Subnet Mask for SP B,
then click OK.
b. Initializing the Storage System
26. EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
25 Figure 9
Network Tab
28. Select the connection name that you assigned...
Initialization Guide - Page 27
...Select Yes and click Submit. Wait about 30 seconds, then return to the setup screen.
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide
27 Please wait a moment before reconnecting.
33. Refresh the screen (press F5)...system returns you will restart automatically. Repeat steps 16 through 27, setting the time, date, and port speed for SP A. Initializing the Storage System
32.
Initialization Guide - Page 28
... display descriptions of each standby power supply (SPS) or battery backup unit (BBU) of the storage system. You can now set the battery test time, so that each week the SP runs... b. Double-click the icons for the storage system and standby power
supply components in the dialog box.
28
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide Setting Battery Test Time
Setting Battery...
Initialization Guide - Page 32
... the Management Port from which the laptop is automatically set for example, 10.42.12.100/setup
If you do not want it to the SP with /setup appended, for the other SP.
32
EMC CLARiiON CX300, CX500, and CX700 Initialization Guide However, be a part of a larger domain, set initial security parameters while still connected...
Similar Questions
Emc Ns502g Power Supply
Hello, does anybody know the power supply nameplate wattage of the Celerra NS502G??
Hello, does anybody know the power supply nameplate wattage of the Celerra NS502G??
(Posted by abrunero 11 years ago)
How To Replace Faulty Power Supply Of Ns720g
(Posted by mousumir 12 years ago)
I Need One 512 Mb Memory Chip For Ax150sci
The unit reports: The write cache is currently disabled. The write cache is disabled when faulted co...
The unit reports: The write cache is currently disabled. The write cache is disabled when faulted co...
(Posted by bsirotin 14 years ago)