Dell PowerConnect 6248 Support Question
Find answers below for this question about Dell PowerConnect 6248.Need a Dell PowerConnect 6248 manual? We have 5 online manuals for this item!
Question posted by Prirendyr on October 31st, 2013
How To Telnet To Dell 6248
The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dell PowerConnect 6248 Manual Pages
Command Line Interface Guide - Page 59
... CLI commands.
Command Groups
59 Configures the switch clock, name and authorized users. Configures web-based access to the switch. System Command Groups (continued)
Command Group Syslog System Management Telnet Server
User Interface
Web Server
Description
Manages and displays syslog messages.
Configures Telnet service on the switch and displays Telnet information. Table 1-1.
Command Line Interface Guide - Page 1348
... port port number • port number - ip telnet server disable
The ip telnet server disable command is used to enable/disable the Telnet service on the switch.
Telnet service port number (Range: 1-65535)
1348
Telnet Server Commands
Example console#configure console(config)#ip telnet server disable console(config)# no ip telnet server disable
Parameter Ranges Not applicable
Command...
User's Guide - Page 19
...the firmware available on the Dell Support website, support.dell.com.
The Dell PowerConnect 6224 switch supports 24 1000Base-T copper ports and 4 "combo" ports for RJ-45 or SFP interfaces. The topics covered in this product. The Dell™ PowerConnect™ 6200 series are provided with hot swappable stack members. The Dell PowerConnect 6248 supports 48 1000Base-T copper ports...
User's Guide - Page 38
... PowerConnect 6200 Series switches are available on the Dell Support website at www.support.dell.com/manuals: • Getting Started Guide-provides information about the switch models in which the server maintains a user database that provides a secure, remote connection to an inbound telnet connection. Secure Sockets Layer (SSL) protocol provides a means of users accessing the switch...
User's Guide - Page 59
...The right slot (Bay 2) can be used to manage an entire stack.
PowerConnect 6224, 6248, and 6224F Rear Panel
Dual 10G slots for XFP, CX4, or stacking... modules
Dual 10G slots for XFP, CX4, or 10Gbase-T modules. Rear Panel
Each PowerConnect 6200 series switch provides an RS-232 maintenance port, on the rear of the switch...
User's Guide - Page 62
...) stacking cable to 576 front panel ports.
See Figure 4-13.
1. Repeat this process until all of the switches in the stack.
2. For non-PoE switches, you can stack up to 12 PowerConnect 6224 and/or 6248 switches, supporting up to connect the switches. Install a separately purchased stacking module in the stack, connect one of the top...
User's Guide - Page 72
... the console line only.
1. Configure the switch using CLI commands.
72
Configuring Dell PowerConnect Also, if access is complete.
You can be defined. NOTE: If you 're directly connected to access the switch through a Telnet connection. The Easy Setup Wizard welcome message now displays.
The switch can access the switch without a user account if you are for...
User's Guide - Page 74
The configuration process consists of adjusting the ASCII configuration files so that are delivered with Telnet, SSH, and so forth
74
Configuring Dell PowerConnect
Terminal Connection Configuration Your switch requires the following terminal connection parameters for configuration: • no parity • one stop bit • 8 data bits • no flow control
Baud Rate The ...
User's Guide - Page 88
... an Initial Telnet Password • Configuring an Initial HTTP Password • Configuring an Initial HTTPS Password
Modifying Switching Port Default Settings
When configuring/receiving IP addresses through DHCP and BOOTP, the configuration received from these servers includes the IP address, and may include subnet mask and default gateway.
88
Configuring Dell PowerConnect can be...
User's Guide - Page 91
...configured for the local terminal only and allows a one-time access to the switch. Configuring Dell PowerConnect
91
AAA uses both local and remote user databases.
all passwords are user-defined.... The procedure is applicable for the following services: • Console • Telnet • SSH • HTTP • HTTPS
NOTE: When creating a user name, the default priority ...
User's Guide - Page 92
...(config-line)#password pass1234 • When initially logging onto a switch through a console session, enter secret123 at the password prompt.
Configuring an Initial Telnet Password To configure an initial Telnet password, enter the following commands:
console(config)#ip http authentication local console(config)#username admin password user1234 level 15
92
Configuring Dell PowerConnect
User's Guide - Page 93
... you upgrade (install a new version of) the control software application on the switch. NOTE: In the Web browser enable SSL 2.0 or greater for the page content to use an HTTPS session over a console, a Telnet, or an SSH session.
Configuring Dell PowerConnect
93 console#configure console(config)#crypto certificate 1 generate console(config-crypto-cert)#country...
User's Guide - Page 113
...config-line)#password tommy123 console(config-line)#exit console(config)#line telnet console(config-line)#login authentication default console(config-line)#enable ...switch is 15. Save the running -config startup-config
Configuring Dell PowerConnect
113 console(config)#exit console#copy running -config file to allow access for a local user-console, Telnet, or Web Server, for console, telnet...
User's Guide - Page 191
.... Enables or disables the ability of the switch to modify the telnet port.
Telnet Server Use the Telnet Server page to enable or disable telnet service on the switch or to accept VLAN assignment from the RADIUS server.
Table 6-35.
The following field:
• Admin Mode- To display the Telnet Server page, click System →Management Security...
User's Guide - Page 192
... information about the CLI commands that perform this function, see the Telnet Server Commands chapter in the CLI Reference Guide. Telnet Server Commands
CLI Command ip telnet server disable ip telnet port show ip telnet
Description
Enables/disables the Telnet service on the switch. Telnet Server
The Telnet Server page contains the following table summarizes the equivalent CLI commands...
Getting Started Guide - Page 266
...port counters show stack-port diag show switch
show supported switchtype
LED
LED Dell Power Connect PC6248P ,PC6224P ,PC6248 , PC6224ו.PC6224F -
PowerConnect 6200
PC 6224
1-1
PC 6248
2-1
...
Release Notes - Page 3
..., release note revisions, or additional assistance, please visit the
Support Web Site http://support.dell.com/.
PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Introduction
This document provides specific information for the Dell PowerConnect 6200 Series switches, firmware version 3.2.0.6. Firmware Specifications
Firmware Version Details
Boot PROM Name Not Applicable
Version No...
Release Notes - Page 4
... in these Release Notes to upgrade this operation. Firmware Downgrade
Downgrading from 3.2.0.6 to the Dell™ PowerConnect™ 6200 Series Systems CLI Reference Guide and the Dell™ PowerConnect™ 6200 Series Configuration Guide.
NOTE: OMNM 4.1 will not discover the switches running firmware version 2.x or earlier.
Only use it to deploy 3.x (or later) firmware to...
Release Notes - Page 25
.../6224P/6248/6248P Release Notes
RADIUS Accounting Servers
Title radius-server host acct
Description The switches do not support creating accounting server names with the same name although the CLI Reference Manual and User Guide state that it is executed.
Default: Disabled by default. Use 'no banner motd' to the Dell™ PowerConnect™...
Configuration Guide - Page 54
...- Dell tested the switch software with Nessus. Protection of Service: • Spans two categories:
- Protection of the network • Protects against DoS attacks. Each type of features that help a network administrator protect networks against the exploitation of a number of Service Protection feature. Nessus is a widelyused vulnerability assessment tool. • PowerConnect 6200...
Similar Questions
How To Configure Vlan On Dell Switch Powerconnect 3548p
(Posted by kywilie 9 years ago)
How To Configure Switches Powerconnect To Route Multicast Traffic
(Posted by baxmim 9 years ago)
How To Show Mac Address Switch Powerconnect
(Posted by soundlmgale 9 years ago)
How To Show Mac Address Switch Powerconnect M6348