Get support for Dell PowerConnect 6248

Dell PowerConnect 6248 Support Question

Dell PowerConnect 6248 Support Question

Find answers below for this question about Dell PowerConnect 6248.
Need a Dell PowerConnect 6248 manual? We have 5 online manuals for this item!
Question posted by kalajacob6 on October 26th, 2013

Powerconnect 6248 How To Stack

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerConnect 6248 Manual Pages

User's Guide - Page 19

...or SFP interfaces. The Dell™ PowerConnect™ 6200 series are provided with hot swappable stack members. The Dell PowerConnect 6248P adds support for RJ-45 or SFP interfaces. The Dell PowerConnect 6248 supports 48 1000Base-T copper ports and 4 "combo" ports for this section include: • System Features • Switching Features • Routing Features • IPv6...
User's Guide - Page 46

... for that the admin user and password is configured on the system. 3. Turn on the switch (or stack) and wait until the startup is divided into command modes. If you connect the terminal to..."Serial Cable Connection" on page 52 for the first time, the switches elect the Master Switch, which displays as asterisks (*). When a stack is the User EXEC mode. The Password: prompt now displays. 4. ...
User's Guide - Page 59

...switch. Dual 10Gbps expansion slots are also mounted on the rear. RS-232 management port DC power AC power Figure 4-7. The left slot (Bay 1) can support a plug-in Dual 10GbE XFP module, a CX4 module, or a stacking module. PowerConnect... an entire stack. PowerConnect 6224, 6248, and 6224F Rear Panel Dual 10G slots for XFP, CX4, or stacking modules Dual 10G slots for XFP,...
User's Guide - Page 61

... x 460 x 44 mm (W x D x H). • 17.32 x 18.11 x 1.73 inch (W x D x H). The default baud rate is used only for the first time, the switches elect a Master Switch, which may occupy any location in the stack. Connect the terminal to an EIA/TIA-232 port. Hardware Description 61 This port provides a direct connection to the...
User's Guide - Page 62

... information. Install a separately purchased stacking module in the stack. 2. For non-PoE switches, you can stack up to 12 PowerConnect 6224 and/or 6248 switches, supporting up to connect the switches. See Figure 4-13. 1. See "System LEDs" for information on the left side of the devices are connected. 4. The PowerConnect 6248 has four fans. Create a stack by observing the LEDs...
User's Guide - Page 71

... Menu Functions • Sample Configuration Process After completing all external connections, connect a terminal to the switch to use the CLI. When a stack is described later in this product. 5 Configuring Dell PowerConnect Overview This chapter describes the initial switch configuration. If you will not be able to monitor the boot process and other functions is...
User's Guide - Page 254

.... Displays a 16-byte character string to identify the model of the switch to become the Management Switch. Changes the identifier for stacking, and information regarding each type of switches supported. • Switch Index - Moves the Management Switch functionality from one switch to the switch. • Switch Model ID - Figure 6-113. Drop-down list permits selection of supported...
Getting Started Guide - Page 7

Site Preparation PowerConnect 6200 series switches can be installed as a stack of self-adhesive rubber pads for the free-standing switch (four pads are included) • User Documentation CD • Getting Started Guide • Product Information Guide Getting Started Guide 5 The ambient switch operating temperature range is 0 to 45ºC (32 to 113ºF) at support...
Getting Started Guide - Page 9

...the rack-mounting holes on the switch line up for the first time, the switches elect the Master Switch, which may occupy any location in the stack. Connecting a Switch to a Terminal 1 Connect ... power cable from a (separately purchased) PowerConnect RPS-600 for non-PoE switches or PowerConnect EPS-470 for other switches that connect to or support the switch. 1 Connect the supplied AC power cable...
Getting Started Guide - Page 11

Connecting a Stack of Switches NOTE: Long cable not shown in Figure 1-3. The resulting ring topology allows the entire stack to function as a single switch with resilient fail-over capabilities. Figure 1-3. Getting Started Guide 9
Getting Started Guide - Page 12

... to connect a terminal to a terminal desktop system running terminal emulation software. c Set the data format to configure the switch or stack. www.dell.com | support.dell.com Starting and Configuring the Switch After completing all external connections, connect a terminal to a switch to 8 data bits, 1 stop bit, and no parity. Additional advanced functions are installing...
Getting Started Guide - Page 13

... top left LED in the stack. When a stack is powered up for approximately 60 seconds. 3 Connect the female connector of switches, connect the terminal to determine if the switch is fully operational before completely booting. This switch will not be able to the AC receptacle. 5 Activate the AC power receptacle. The PowerConnect 6200 series console ports...
Getting Started Guide - Page 18

... with minimal operational impact in the event of: • Switch failure • Inter-switch stacking link failure • Switch insertion • Switch removal If the Master Switch goes off line, any of the Member Switches in the stack, including the Firmware Version, Hardware Version, Management Preference, Switch MAC Address, and Switch Serial Number. The system will not become valid for...
Getting Started Guide - Page 19

... file information. Operating as a standalone switch. System Initialization for Stacking Mode. Stack ID Renumbering You can insert and remove switches to the switch that is applied to /from the stack. This forces all switches are running the same version of Switches You can manually assign Stack IDs to those switches that Stack ID. A switch can save the configuration file.
Getting Started Guide - Page 266

...8235;‪show stack-port counters show stack-port diag show switch‬‬ ‫‪show supported switchtype‬‬ LED‬‬ LED Dell Power Connect PC6248P ,PC6224P ,PC6248 , PC6224‬ו‪.PC6224F -‬‬ PowerConnect 6200 ‫‪PC 6224‬‬ 1-1‬‬ ‫‪PC 6248‬‬ 2-1‬...
Release Notes - Page 3

NOTE: The PC6200 switches when stacked require that this procedure may result in the zip... in the Dell PowerConnect 6200 Series Release 3.2 Upgrade Procedure included in your switch becoming inoperable. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Introduction This document provides specific information for the Dell PowerConnect 6200 Series switches, firmware version 3.2.0.6....
Release Notes - Page 5

... etc. Upon changing the role of a module, a reboot of the switch will allow the forwarding plane of stack units to continue to forward packets while the control and management planes restart ...IPX are supported. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Added Functionality in this Release ¾ Non-Stop Forwarding This feature creates an option to allow the stacking and CX-4 plug-...
Release Notes - Page 19

.... Re-enabled objects to each other chips such as an SNMP trap receiver on stack members. Added validation for User could be displayed. Firmware missing no form for syslog...-existing host cannot be deleted for logging syslog. Added the no switch 2 priority 2 command does not work. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Issues Resolved The following is a list of the...
Release Notes - Page 25

...the number of seconds that session. Default: Not applicable Stacking/CX-4 Module Configuration Title stack-port / {ethernet | stack} Description This command is executed. Configurable Message of the...: Disabled by default. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes RADIUS Accounting Servers Title radius-server host acct Description The switches do not support creating accounting...
Release Notes - Page 27

... mode without using TACACS as TACACS. In a large stack with large configuration. The command vlan protocol group expected ...UI sessions. None. If the configuration is saved and the switch is reset, the configuration is not a member of the other...startup-config through HTTP. Generic failure message. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Known Issues Summary Non-...

Similar Questions

Powerconnect 6248 Stacking Module Is It Hot Swappable
PowerConnect 6248 stacking module is it hot swappable? I am trying to add a switch to an existing 6...
(Posted by richardcadogan 11 years ago)
Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerConnect 6248 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.