Get support for Dell PowerConnect 6224

Dell PowerConnect 6224 Support Question

Dell PowerConnect 6224 Support Question

Find answers below for this question about Dell PowerConnect 6224.
Need a Dell PowerConnect 6224 manual? We have 5 online manuals for this item!
Question posted by elvanaetch on January 6th, 2014

How Enable Jumbo Frames Powerconnect 6224

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerConnect 6224 Manual Pages

Command Line Interface Guide - Page 67

... Ethernet type interfaces. Command Groups 67 Command Description Mode* ip arp inspection vlan Enables Dynamic ARP Inspection on a single GC VLAN or a range of the ARP packets...VLAN range. Enters the interface configuration mode to GC configure an Ethernet type interface. Enables jumbo frames on all the VLANs in ARP packet validation. PE Adds a description to an interface...
Command Line Interface Guide - Page 115

... stats Displays the statistical information about each PE virtual router configured on the switch. show ip vrrp Displays whether VRRP functionality is enabled PE or disabled on the switch. IC NOTE: *For the meaning of a virtual router configured on the switch. vrrp track ip route Tracks route reachability. IC show ip vrrp interface brief...
Command Line Interface Guide - Page 116

NOTE: *For the meaning of each Mode abbreviation, see "Mode Types" on the switch. Captive Portal Command authentication timeout captive-portal http port https port show captive-portal show boot Displays the current status of attempts to monitor. CP Enables the captive portal configuration mode. Blocks all captive portal instances PE in the...
Command Line Interface Guide - Page 123

... last TDR (Time Domain PE Reflectometry) tests on page 60. Power Over Ethernet (PoE) Command power inline power inline legacy Description Mode* Enables/disables the ability of the switch by enabling the user lockout feature. PHY Diagnostics Command Description Mode* show fiber-ports optical- show copper-ports cable- Displays the optical transceiver diagnostics...
Command Line Interface Guide - Page 239

Example console(config)#isdp advertise-v2 isdp enable The isdp enable command enables ISDP on a specific interface. Syntax isdp enable no user guidelines for this command. User the "no" form of this command in global configuration mode to enable sending ISDP packets on the switch. Use this command to disable ISDP. Use this command to disable sending...
Command Line Interface Guide - Page 290

...this command. Example The following example shows how ports 5/g18 to 5/g20 and ports 3/g1 to enable jumbo frames on an interface by adjusting the maximum size of the active interfaces, it does not stop executing...to the default setting, use the no form of VLAN-tagged frames). 290 Ethernet Configuration Commands Default Configuration This command has no mtu • bytes - To return ...
Command Line Interface Guide - Page 302

... 1 default untagged System 8 VLAN008 tagged Dynamic 11 VLAN0011 tagged Static 19 IPv6 VLAN untagged Static 72 VLAN0072 untagged Static Static configuration: PVID: 1 (default) Ingress Filtering: Enabled Acceptable Frame Type: All Port 1/xg1 is statically configured to: VLAN Name Egress rule 1 default untagged 302 Ethernet Configuration Commands
Command Line Interface Guide - Page 584

Syntax show interface switchport ethernet 1/g1 Port 1/g1: VLAN Membership mode: General Operating parameters: PVID: 1 (default) Ingress Filtering: Enabled Acceptable Frame Type: All GVRP status: Enabled Protected: Enabled Port 1/g1 is member in: VLAN Name Egress rule Type ---- --------- ----------- ----- 1 default untagged Default 584 VLAN Commands Default Configuration ...
Command Line Interface Guide - Page 585

... 8 VLAN008 tagged Dynamic 11 VLAN0011 tagged Static 19 IPv6 VLAN untagged Static 72 VLAN0072 untagged Static Static configuration: PVID: 1 (default) Ingress Filtering: Enabled Acceptable Frame Type: All Port 1/g1 is statically configured to: VLAN Name Egress rule ---- --------- ----------- 11 VLAN0011 tagged 19 IPv6 VLAN untagged 72 VLAN0072 untagged Forbidden...
Command Line Interface Guide - Page 586

...g19 Port 2/g19: Operating parameters: PVID: 2922 Ingress Filtering: Enabled Acceptable Frame Type: Untagged GVRP status: Disabled 586 VLAN Commands Port 1/g1... ----- 91 IP Telephony tagged Static Static configuration: PVID: 8 Ingress Filtering: Disabled Acceptable Frame Type: All Port 1/g2 is statically configured to: VLAN Name Egress rule ---- --------- -----------...
Command Line Interface Guide - Page 587

...show all - Port 2/g19 is member in: VLAN Name Egress rule ---- --------- ----------- 2921 Primary A untagged 2922 Community A1 untagged Static configuration: PVID: 2922 Ingress Filtering: Enabled Acceptable Frame Type: Untagged GVRP status: Disabled Port 2/g19 is automatically generated when you create a protocol-based VLAN group with the vlan protocol group command. •...
Command Line Interface Guide - Page 594

... remove vlan-list 594 VLAN Commands Example The following example configures 1/g8 to discard untagged frames at ingress, use the no form of this command. Syntax switchport general acceptable-frame-type tagged-only no user guidelines. To enable untagged frames at ingress. console(config)#interface ethernet 1/g8 console(config-if-1/g8)#switchport general acceptable...
Command Line Interface Guide - Page 1055

...Configuration Auto Config is used to the switch by default. boot host auto-save The boot host auto-save command enables/disables the option to automatically save configuration files downloaded to enable/disable Auto Config on the switch. Syntax boot host auto-save no boot... console#no boot host auto-save boot host dhcp The boot host dhcp command is enabled. Autoconfig Commands 1055
Command Line Interface Guide - Page 1170

.... Usage Guidelines No specific guidelines. power inline The power inline command enables/disables the ability of the switch to support legacy Ethernet powered devices. Disables the device discovery protocol and...-if-1/g1)# power inline auto power inline legacy The power inline legacy command enables/disables the ability of the port to deliver power. Syntax Description power inline { ...
User's Guide - Page 25

...temporarily halted to configure the port speeds advertised. Port-Based Features Jumbo Frames Support Jumbo frames enable transporting data in fewer frames to advertise modes of their transmission capabilities. Auto-MDI/MDIX Support The switch supports auto-detection between two switches that the higher speed switch refrains from sending packets. Auto Negotiation Auto negotiation allows the...
User's Guide - Page 46

...: prompt now displays. 4. The console# prompt now displays. 5. ASCII terminals can be virtually connected to four simultaneous Telnet sessions. Your switch supports up enable passwords. 46 Using Dell™ OpenManage™ Switch Administrator All CLI commands can be used to access configuration sub-systems. Privileged EXEC mode may occupy any location in the...
User's Guide - Page 194

... Size Denial of Service protection. 194 Configuring System Information Enabling ICMP DoS prevention causes the switch to TCP/UDP destination port. • Denial of Service L4 Port - Enables L4 Port Denial of Service protection. Enables Maximum ICMP Packet Size Denial of Service. The device is enabled, the switch will drop ICMP ping packets that have a size...
User's Guide - Page 248

... Utility Commands - Auto Configuration Commands CLI Command boot host auto-save boot host dhcp boot host retry-count show boot Description Enables/disables automatically saving the downloaded configuration on the switch. The number of attempts to configure Auto Configuring. Auto Config chapter in the CLI Reference Guide. Displays the current status of...
User's Guide - Page 322

...Enables jumbo frames on an interface by adjusting the maximum size of a packet or maximum transmission unit (MTU). Displays information about the CLI commands that are members of the same VLAN. Protected Port Configuration Use the Protected Port Configuration page to other ports within the VLAN. To display the Port Configuration page, click Switching...322 Configuring Switching Information Port...
User's Guide - Page 362

... need to divide the 4k VLAN ID space to send traffic on network traffic. With Double VLAN Tunneling enabled, every frame that is updated. Displays VLAN information. Creates a VLAN. To access the Double VLAN Global Configuration page, click Switching →VLAN →Double VLAN → Global Configuration from the navigation tree. 362 Configuring...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerConnect 6224 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.