Ventilation Products
Page 14
VIPR182R VersaVentTM rear downdrafts Retractable downdrafts quietly do their job, then disappear into your countertop. 14 MODELS WITH CONTROLS ON DOWNDRAFT 30" width - VIPR182 MODELS WITH REMOTEMOUNTED CONTROLS 30" width - VIPR162 48" width - VIPR102 36" width - VIPR162R 48" width - VIPR102R 36" width -
VIPR182R VersaVentTM rear downdrafts Retractable downdrafts quietly do their job, then disappear into your countertop. 14 MODELS WITH CONTROLS ON DOWNDRAFT 30" width - VIPR182 MODELS WITH REMOTEMOUNTED CONTROLS 30" width - VIPR162 48" width - VIPR102 36" width - VIPR162R 48" width - VIPR102R 36" width -
Ventilation Products
Page 15
...) (for 10 minutes before automatically shutting off feature allows operation for use of a Viking gas char-grill, a Viking 18" high overhead hood is installed with Viking rangetops Must use Viking ventilator kits with Viking downdrafts; use with 48" wide downdraft only) Do not install with a Viking rangetop that has a gas char-grill or wok; Appearance and design For...
...) (for 10 minutes before automatically shutting off feature allows operation for use of a Viking gas char-grill, a Viking 18" high overhead hood is installed with Viking rangetops Must use Viking ventilator kits with Viking downdrafts; use with 48" wide downdraft only) Do not install with a Viking rangetop that has a gas char-grill or wok; Appearance and design For...
Ventilation Products
Page 28
VersaVentTM rear downdrafts 30" width - DIPR161R 45" width - DIPR151R Remote-mounted control panels install anywhere on your countertop. 28 DIPR101R 36" width -
VersaVentTM rear downdrafts 30" width - DIPR161R 45" width - DIPR151R Remote-mounted control panels install anywhere on your countertop. 28 DIPR101R 36" width -
Ventilation Products
Page 29
... (VIDV500) • Exterior ventilator kits - 900 CFM (VEDV900) or 1,200 CFM (VEDV1200) (for 10 minutes before automatically shutting off feature allows operation for use Viking ventilator kits with 45" wide downdraft only) Stainless steel finish is standard; remote-mounted control is black with stainless steel frame No matter what you cook, the..., easy-to-clean filters are dishwasher-safe and sized Filter alert reminds user to clean filters after approximately 30 hours of use Must use with Viking downdrafts;
... (VIDV500) • Exterior ventilator kits - 900 CFM (VEDV900) or 1,200 CFM (VEDV1200) (for 10 minutes before automatically shutting off feature allows operation for use Viking ventilator kits with 45" wide downdraft only) Stainless steel finish is standard; remote-mounted control is black with stainless steel frame No matter what you cook, the..., easy-to-clean filters are dishwasher-safe and sized Filter alert reminds user to clean filters after approximately 30 hours of use Must use with Viking downdrafts;
Ventilation Products
Page 31
... "ledge" and "ledgeless" models; power ventilators to 9' high Classic Chimney wall hoods and Slim Traditional wall hoods • Adjustable duct cover comes standard - for Designer downdraft Gray with Designer Stainless Steel/White glass cooktops Wall Hood Warming Shelf Panels Wall Hood Backsplashes 31 Accessory Rail Remote-Mounted Control standard on top...
... "ledge" and "ledgeless" models; power ventilators to 9' high Classic Chimney wall hoods and Slim Traditional wall hoods • Adjustable duct cover comes standard - for Designer downdraft Gray with Designer Stainless Steel/White glass cooktops Wall Hood Warming Shelf Panels Wall Hood Backsplashes 31 Accessory Rail Remote-Mounted Control standard on top...
Ventilation Products
Page 32
... sage 32 It's something Viking calls Design Integrity™. ...even the grain of three Viking product offerings - You wouldn't install...Viking offers complete ultra-premium kitchens and truly consistent design, while delivering the quality and performance that makes Viking... Mint Julep (MJ), Sea Glass (SE), Iridescent Blue (IB), Viking Blue (VB), Pumpkin (PM), Racing Red (RR), Apple Red ... Rail in one can match the Viking kitchen and Viking Design Integrity. all brass components have... finishes. With the complete Viking indoor or outdoor kitchen, ...Stainless Steel (SS) Viking uses the most up...
... sage 32 It's something Viking calls Design Integrity™. ...even the grain of three Viking product offerings - You wouldn't install...Viking offers complete ultra-premium kitchens and truly consistent design, while delivering the quality and performance that makes Viking... Mint Julep (MJ), Sea Glass (SE), Iridescent Blue (IB), Viking Blue (VB), Pumpkin (PM), Racing Red (RR), Apple Red ... Rail in one can match the Viking kitchen and Viking Design Integrity. all brass components have... finishes. With the complete Viking indoor or outdoor kitchen, ...Stainless Steel (SS) Viking uses the most up...
Ventilation Products
Page 33
Warranty highlights Professional and Designer Series wall and island hoods, Professional downdraft Three-year full - complete unit Lifetime limited - all ventilator motors Ninety-day limited - complete unit Lifetime limited - stainless steel exterior Five-year... - cosmetic parts such as glass, painted items, and decorative items Designer Series downdraft One-year full - cosmetic parts such as glass, painted items, and decorative items mint julep sea glass iridescent blue viking blue pumpkin racing red apple red burgundy plum black chocolate cobalt blue 33 stainless ...
Warranty highlights Professional and Designer Series wall and island hoods, Professional downdraft Three-year full - complete unit Lifetime limited - all ventilator motors Ninety-day limited - complete unit Lifetime limited - stainless steel exterior Five-year... - cosmetic parts such as glass, painted items, and decorative items Designer Series downdraft One-year full - cosmetic parts such as glass, painted items, and decorative items mint julep sea glass iridescent blue viking blue pumpkin racing red apple red burgundy plum black chocolate cobalt blue 33 stainless ...
Ventilation Products
Page 41
Rear downdrafts - DIPR161RSS 45" W. VIPR102(R)SS 36" W. VIPR162(R)SS 48" W. Professional Model 30" W. Designer Model 30" W. DIPR151RSS Number of Filters 2 2 2 re a r d o wndr a f t ...transition to 6" round) 10" (can transition to 6" round) 10" (can transition to 6" round) Exterior 10" 10" 10" Maximum Amps Interior 4.0 Exterior 6.0 4.0 6.0 4.0 6.0 Rear downdrafts - VIPR182(R)SS Number of Filters 2 2 2 re a r d o wndr a f t s Recommended Ventilator Kits Recommended Duct Size Interior VIDV500 VIDV500 VIDV500 Exterior VEDV900/VEDV1200 VEDV900/VEDV1200 VEDV900/...
Rear downdrafts - DIPR161RSS 45" W. VIPR102(R)SS 36" W. VIPR162(R)SS 48" W. Professional Model 30" W. Designer Model 30" W. DIPR151RSS Number of Filters 2 2 2 re a r d o wndr a f t ...transition to 6" round) 10" (can transition to 6" round) 10" (can transition to 6" round) Exterior 10" 10" 10" Maximum Amps Interior 4.0 Exterior 6.0 4.0 6.0 4.0 6.0 Rear downdrafts - VIPR182(R)SS Number of Filters 2 2 2 re a r d o wndr a f t s Recommended Ventilator Kits Recommended Duct Size Interior VIDV500 VIDV500 VIDV500 Exterior VEDV900/VEDV1200 VEDV900/VEDV1200 VEDV900/...
Specs
Page 1
...over cooking surface or vessels DIPR models include • For use with Viking Designer cooktops & rangetops (non-grill, non-wok**) • Island rangetop must be below expectations. cabinets*) DESIGNER DOWNDRAFT W/REMOTE DIPR101R - 30"W. (fits in most 30"W. cabinets*) *... 2 0 1 1 V R C - VENTILATION Built-In VersaVent™ Rear Downdraft Standard Features & Accessories All models include • Downdraft blower systems are dishwasher-safe and sized VIPR models include • For use with Viking Professional cooktops • Controls on intake top VIPR(R) models include • For...
...over cooking surface or vessels DIPR models include • For use with Viking Designer cooktops & rangetops (non-grill, non-wok**) • Island rangetop must be below expectations. cabinets*) DESIGNER DOWNDRAFT W/REMOTE DIPR101R - 30"W. (fits in most 30"W. cabinets*) *... 2 0 1 1 V R C - VENTILATION Built-In VersaVent™ Rear Downdraft Standard Features & Accessories All models include • Downdraft blower systems are dishwasher-safe and sized VIPR models include • For use with Viking Professional cooktops • Controls on intake top VIPR(R) models include • For...
Specs
Page 2
... GUIDE VIKINGRANGE.COM • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - Dimensions & Specifications PRODUCT DIMENSIONS VIPR Professional Downdraft VIPR Professional Downdraft w/Remote DIPR Designer Downdraft w/Remote (5.12"cm) A PROFESSIONAL (5.12"cm) A 8(2-121.1/1cm6") DESIGNER (82-01.5/1c6m") VIPR102/102R Overall width (A) 30" (76.2 ... height From countertop 8-11/16" (22.1 cm) Approx. VENTILATION Built-In VersaVent™ Rear Downdraft % Please see Installation Notes & Accessories for important information, including blower kits and remote mounted controls.
... GUIDE VIKINGRANGE.COM • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - Dimensions & Specifications PRODUCT DIMENSIONS VIPR Professional Downdraft VIPR Professional Downdraft w/Remote DIPR Designer Downdraft w/Remote (5.12"cm) A PROFESSIONAL (5.12"cm) A 8(2-121.1/1cm6") DESIGNER (82-01.5/1c6m") VIPR102/102R Overall width (A) 30" (76.2 ... height From countertop 8-11/16" (22.1 cm) Approx. VENTILATION Built-In VersaVent™ Rear Downdraft % Please see Installation Notes & Accessories for important information, including blower kits and remote mounted controls.
Specs
Page 3
....COM • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - Countertops with remote control) - Distance between the controls and the edge of cabinet. (Viking recommends that there is no interference when air vent is raised and lowered. INFORMATION SUBJECT TO CHANGE Do not install it will cover the entire... back wall of the cabinet. Rangetops and Designer cooktops must be 4" min. In these cases, the downdraft will not be covered by the downdraft, and provide a clearance hole in the back wall of the cabinet, so you must you must be used with an...
....COM • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - Countertops with remote control) - Distance between the controls and the edge of cabinet. (Viking recommends that there is no interference when air vent is raised and lowered. INFORMATION SUBJECT TO CHANGE Do not install it will cover the entire... back wall of the cabinet. Rangetops and Designer cooktops must be 4" min. In these cases, the downdraft will not be covered by the downdraft, and provide a clearance hole in the back wall of the cabinet, so you must you must be used with an...
Specs
Page 4
....4 cm) Max. Amps Interior Exterior 4.0 5.7 4.0 5.7 4.0 5.7/3.0 4.0 5.7 4.0 5.7 4.0 5.7/3.0 4.0 5.7 4.0 5.7 4.0 5.7 Note: Proper installation/ ducting is equivalent to the downdraft plug (included) • 120 VAC/60 Hz • Max. For longer duct runs, increase duct size and contact a qualified and trained installer. • Straight runs...requirements, if any. • Max. Installation Requirements VENTILATION Built-In VersaVent™ Rear Downdraft VIPR Professional Downdraft DUCTING • Check with 3- duct run . it creates back pressure/air turbulence and...
....4 cm) Max. Amps Interior Exterior 4.0 5.7 4.0 5.7 4.0 5.7/3.0 4.0 5.7 4.0 5.7 4.0 5.7/3.0 4.0 5.7 4.0 5.7 4.0 5.7 Note: Proper installation/ ducting is equivalent to the downdraft plug (included) • 120 VAC/60 Hz • Max. For longer duct runs, increase duct size and contact a qualified and trained installer. • Straight runs...requirements, if any. • Max. Installation Requirements VENTILATION Built-In VersaVent™ Rear Downdraft VIPR Professional Downdraft DUCTING • Check with 3- duct run . it creates back pressure/air turbulence and...
Specs
Page 5
... 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - HOLE CUT OUT ON DOTTED LINE REMOTE CONTROL CUTOUT Model Downdraft Cutout Cooktop Cutout Width Depth Width Depth VIPR102/102R w/VECU106 27" (68.6 cm) 2-1/4" (5.7 cm) 28-3/4" (73.0 cm) 20... 1/4" (0.6 cm) DIA. HOLE 5/8" (1.6 cm) DIA. VENTILATION Built-In VersaVent™ Rear Downdraft Installation Requirements PROFESSIONAL ACCESS REQUIREMENTS & SITE PREPARATION 7/8" (2.2 cm) 27" (68.6 cm) 7/8" (2.2 cm) 2-1/4" (5.7 cm) Downdraft: VIPR101/101R 20-1/4" Cooktop: VECU106 (51.4 cm) 28-3/4" (73.0 cm) VIPR102/102R 7/8"...
... 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - HOLE CUT OUT ON DOTTED LINE REMOTE CONTROL CUTOUT Model Downdraft Cutout Cooktop Cutout Width Depth Width Depth VIPR102/102R w/VECU106 27" (68.6 cm) 2-1/4" (5.7 cm) 28-3/4" (73.0 cm) 20... 1/4" (0.6 cm) DIA. HOLE 5/8" (1.6 cm) DIA. VENTILATION Built-In VersaVent™ Rear Downdraft Installation Requirements PROFESSIONAL ACCESS REQUIREMENTS & SITE PREPARATION 7/8" (2.2 cm) 27" (68.6 cm) 7/8" (2.2 cm) 2-1/4" (5.7 cm) Downdraft: VIPR101/101R 20-1/4" Cooktop: VECU106 (51.4 cm) 28-3/4" (73.0 cm) VIPR102/102R 7/8"...
Specs
Page 6
...20-5/8" (52.4 cm) 29-1/8" (73.9 cm) DIPR101R 7/16" (1.1 cm) 42" (106.7 cm) 7/16" (1.1 cm) 2-1/4" (5.7 cm) Downdraft: DIPR150R Cooktops: DECU155 or DGCU155 20-5/8" (52.4 cm) DIPR151R 42-7/8" (108.9 cm) 34-7/8" (88.6 cm) DIPR161R TOP EDGE 1/4" (0.6 cm).... INFORMATION SUBJECT TO CHANGE HOLE CUT OUT ON DOTTED LINE REMOTE CONTROL CUTOUT Model DIPR101R w/DECU105 w/DGCU105 w/DGSU100 DIPR161R w/DECU165 w/DGCU165 w/DGSU160 DIPR151R w/DECU155 w/DGCU155 Downdraft Cutout Width Depth 27" (68.6 cm) 27" (68.6 cm) 27" (68.6 cm) 2-1/4" (5.7 cm) 2-1/4" (5.7 cm) 2-1/4" (5.7 cm) 33" (83.8 ...
...20-5/8" (52.4 cm) 29-1/8" (73.9 cm) DIPR101R 7/16" (1.1 cm) 42" (106.7 cm) 7/16" (1.1 cm) 2-1/4" (5.7 cm) Downdraft: DIPR150R Cooktops: DECU155 or DGCU155 20-5/8" (52.4 cm) DIPR151R 42-7/8" (108.9 cm) 34-7/8" (88.6 cm) DIPR161R TOP EDGE 1/4" (0.6 cm).... INFORMATION SUBJECT TO CHANGE HOLE CUT OUT ON DOTTED LINE REMOTE CONTROL CUTOUT Model DIPR101R w/DECU105 w/DGCU105 w/DGSU100 DIPR161R w/DECU165 w/DGCU165 w/DGSU160 DIPR151R w/DECU155 w/DGCU155 Downdraft Cutout Width Depth 27" (68.6 cm) 27" (68.6 cm) 27" (68.6 cm) 2-1/4" (5.7 cm) 2-1/4" (5.7 cm) 2-1/4" (5.7 cm) 33" (83.8 ...
Specs
Page 7
... items (Professional and Designer) *Must use of non-Viking kits voids product warranty. PLANNING AND DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - VENTILATION Built-In VersaVent™ Rear Downdraft % Installation Notes & Accessories Interior-Power Blower Kit ...rivet the ductwork to install • Must be used with VIPR181/181R Note: Exhaust capacity based on tests with Viking downdrafts; use Viking ventilator kits with 0.1 static pressure. ship wt. Model DSRCGY Description Designer remote mounted control (SS/gray) Approx...
... items (Professional and Designer) *Must use of non-Viking kits voids product warranty. PLANNING AND DESIGN GUIDE VIKINGRANGE.COM • 1-888-VIKING1 REVISED 5/2/11 © 2 0 1 1 V R C - VENTILATION Built-In VersaVent™ Rear Downdraft % Installation Notes & Accessories Interior-Power Blower Kit ...rivet the ductwork to install • Must be used with VIPR181/181R Note: Exhaust capacity based on tests with Viking downdrafts; use Viking ventilator kits with 0.1 static pressure. ship wt. Model DSRCGY Description Designer remote mounted control (SS/gray) Approx...
Installation Instructions
Page 1
...recommended in the manner intended by burners/ elements on "Kitchen Firesafety Tips" published by reaching across burners, an "R" model downdraft (with remote control) MUST be used with a rangetop.The remote control MUST be vented to the service panel. Before ...You can fight the fire with all applicable codes and standards, including fire-rated construction codes and standards. INSTALLER: Save this appliance. VIKING RANGE CORPORATION Downdraft Ventilators MODEL VIPR102 VIPR102R VIPR162 VIPR162R VIPR182 VIPR182R WIDTH 30" 30" w/ remote control 36" 36" w/ remote control 48" 48...
...recommended in the manner intended by burners/ elements on "Kitchen Firesafety Tips" published by reaching across burners, an "R" model downdraft (with remote control) MUST be used with a rangetop.The remote control MUST be vented to the service panel. Before ...You can fight the fire with all applicable codes and standards, including fire-rated construction codes and standards. INSTALLER: Save this appliance. VIKING RANGE CORPORATION Downdraft Ventilators MODEL VIPR102 VIPR102R VIPR162 VIPR162R VIPR182 VIPR182R WIDTH 30" 30" w/ remote control 36" 36" w/ remote control 48" 48...
Installation Instructions
Page 2
... 3-1/4" X 10" DUCT CONNECTOR ELECTRICAL SPECIFICATIONS 120 VAC • 60 Hz • 4.0 A TAKE MEASUREMENTS Exterior Blower Installation This downdraft blower system is designed to be used to exhaust airborne contaminants when cooking with (A) a raised lip and/or (B) a backsplash may... and electrical. 120 VAC • 60 Hz • 6.0 A (max.) • Install the cooktop. VIKING RANGE CORPORATION Downdraft Ventilators PLANNING Interior Blower Installation This downdraft blower system is designed to be used for easier installation. 2. This unit can be rather tight. Note: the...
... 3-1/4" X 10" DUCT CONNECTOR ELECTRICAL SPECIFICATIONS 120 VAC • 60 Hz • 4.0 A TAKE MEASUREMENTS Exterior Blower Installation This downdraft blower system is designed to be used to exhaust airborne contaminants when cooking with (A) a raised lip and/or (B) a backsplash may... and electrical. 120 VAC • 60 Hz • 6.0 A (max.) • Install the cooktop. VIKING RANGE CORPORATION Downdraft Ventilators PLANNING Interior Blower Installation This downdraft blower system is designed to be used for easier installation. 2. This unit can be rather tight. Note: the...
Installation Instructions
Page 3
...less. 3. NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. VIKING RANGE CORPORATION TAKE MEASUREMENTS (CONTINUED) Downdraft Ventilators Interior Blower Installation SIDE VIEW OF DOWNDRAFT WITH VIDV500 INTERIOR BLOWER 2" 7 11 16 " 1" 3 1 4 " 3 5 8 " ...or less. NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. OF STRAIGHT DUCT 3. The interior downdraft blower system is designed for use with 3-1/4" x 10" ductwork (can be transitioned to VEDV900 or VEDV1200 Exterior Blower) 7 11 ...
...less. 3. NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. VIKING RANGE CORPORATION TAKE MEASUREMENTS (CONTINUED) Downdraft Ventilators Interior Blower Installation SIDE VIEW OF DOWNDRAFT WITH VIDV500 INTERIOR BLOWER 2" 7 11 16 " 1" 3 1 4 " 3 5 8 " ...or less. NOTE: The equivalent feet of various roof and wall caps has been taken into consideration. OF STRAIGHT DUCT 3. The interior downdraft blower system is designed for use with 3-1/4" x 10" ductwork (can be transitioned to VEDV900 or VEDV1200 Exterior Blower) 7 11 ...
Installation Instructions
Page 4
VIKING RANGE CORPORATION PLAN THE CABINET CUTOUTS Interior Blower Installation Downdraft Ventilators Exterior Blower Installation LEFT SIDE DISCHARGE LEFT SIDE DISCHARGE CENTER LINES OF DUCT CUTOUT 10¼" x 3½" CUTOUT (TYP.) RIGHT SIDE DISCHARGE 241/8" 5½" ...
VIKING RANGE CORPORATION PLAN THE CABINET CUTOUTS Interior Blower Installation Downdraft Ventilators Exterior Blower Installation LEFT SIDE DISCHARGE LEFT SIDE DISCHARGE CENTER LINES OF DUCT CUTOUT 10¼" x 3½" CUTOUT (TYP.) RIGHT SIDE DISCHARGE 241/8" 5½" ...
Installation Instructions
Page 5
...channels and start the 4 nuts, do not tighten. 8. The downdraft has a 2 ft. So you must be covered by the downdraft. Use cover plate (supplied) to a side wall or cabinet floor - VIKING RANGE CORPORATION Downdraft Ventilators PLAN THE WIRING Interior Blower Installation 1. In these cases, the... width of the downdraft covers nearly the entire width of the...
...channels and start the 4 nuts, do not tighten. 8. The downdraft has a 2 ft. So you must be covered by the downdraft. Use cover plate (supplied) to a side wall or cabinet floor - VIKING RANGE CORPORATION Downdraft Ventilators PLAN THE WIRING Interior Blower Installation 1. In these cases, the... width of the downdraft covers nearly the entire width of the...