... & Specifications (VWH 10"H. Wall Hoods w/Standard Ventilator Description 24" 30" 36" Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kit Interior duct size* Interior-Maximum amps 23-7/8" (60.6 cm) 29-7/8" (75.9 cm) 12" (30.5 cm) 12" (30.5 cm) 2 2 N/A 460 CFM...
... & Specifications (VWH 10"H. Wall Hoods w/Standard Ventilator Description 24" 30" 36" Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kit Interior duct size* Interior-Maximum amps 23-7/8" (60.6 cm) 29-7/8" (75.9 cm) 12" (30.5 cm) 12" (30.5 cm) 2 2 N/A 460 CFM...
Installation Instructions
Page 5
...) (121.6 cm) (136.8 cm) (152.1 cm) (167.3 cm) Duct cover depth 12" (30.5 cm) Duct cover height 12" (30.5 cm) Number of lights 2 2 2 2 3 3 4 4 Number of filters 2 2 2 2 3 3 4 4 Heat lamps 1 1 1 1 2 2 2 2 Interior ventilator kits Exterior ventilator kits In-line ventilator kits VINV300/ VINV300/ 600 600/1200 DEV900/ 1200* DEV900/ 1200* DIL900/1200 DIL900/1200...
...) (121.6 cm) (136.8 cm) (152.1 cm) (167.3 cm) Duct cover depth 12" (30.5 cm) Duct cover height 12" (30.5 cm) Number of lights 2 2 2 2 3 3 4 4 Number of filters 2 2 2 2 3 3 4 4 Heat lamps 1 1 1 1 2 2 2 2 Interior ventilator kits Exterior ventilator kits In-line ventilator kits VINV300/ VINV300/ 600 600/1200 DEV900/ 1200* DEV900/ 1200* DIL900/1200 DIL900/1200...
Installation Instructions
Page 7
...Hoods 36", 48", & 60") Seal joints with locally-supplied stainless steel. Note: T-Series Models must be used with longer duct runs. Viking also recommends using a backsplash. 13 or exterior-power ventilator should be protected from the wall. NOTE: Maximum amp rating for this purpose must...the back trim to non-combustible surfaces, and a 24" minimum to 36" (91.4 cm) above the grill surface. An interior- The bottom of filters Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size 36" 35-7/8" (91.1 cm) 2 2 VINV1200* DEV1200*/1500** DIL1200 48"...
...Hoods 36", 48", & 60") Seal joints with locally-supplied stainless steel. Note: T-Series Models must be used with longer duct runs. Viking also recommends using a backsplash. 13 or exterior-power ventilator should be protected from the wall. NOTE: Maximum amp rating for this purpose must...the back trim to non-combustible surfaces, and a 24" minimum to 36" (91.4 cm) above the grill surface. An interior- The bottom of filters Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size 36" 35-7/8" (91.1 cm) 2 2 VINV1200* DEV1200*/1500** DIL1200 48"...
Installation Instructions
Page 8
....0 cm) 24" (61.0 cm) Duct cover depth 12" (30.5 cm) Duct cover height Number of lights 12" (30.5 cm) to 24" (61.0 cm) 2 2 2 3 3 4 4 Number of filters 2 2 2 2 3 3 3 Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits 1 1 VINV300/600 VINV300/600 DEV900/ 1200* DIL900/1200 DEV900/ 1200* DIL900/1200 1 VINV600...
....0 cm) 24" (61.0 cm) Duct cover depth 12" (30.5 cm) Duct cover height Number of lights 12" (30.5 cm) to 24" (61.0 cm) 2 2 2 3 3 4 4 Number of filters 2 2 2 2 3 3 3 Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits 1 1 VINV300/600 VINV300/600 DEV900/ 1200* DIL900/1200 DEV900/ 1200* DIL900/1200 1 VINV600...
Installation Instructions
Page 10
Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size Exterior duct size Interior-Maximum amps Exterior-Maximum amps In-...
Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size Exterior duct size Interior-Maximum amps Exterior-Maximum amps In-...
Installation Instructions
Page 12
VCIH Chimney Island Hoods Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size 36" 12" (30.5 cm) 4 4 VINV600 DEV900/1200* DIL900/1200 7" (17.8 ...
VCIH Chimney Island Hoods Description Duct cover width Duct cover depth Duct cover height Number of lights Number of filters Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size 36" 12" (30.5 cm) 4 4 VINV600 DEV900/1200* DIL900/1200 7" (17.8 ...
Installation Instructions
Page 14
... to left to right. 2) Bottom mounting holes fasten ventilator system to rear of custom hood canopy with all 18"H. Make sure the back wall of filters 2 2 2 3 3 4 4 Heat lamps 1 1 1 2 2 2 2 Interior ventilator kits Exterior ventilator kits In-line ventilator kits VINV300/ 600/1200* DEV900/ 1200* DIL900/1200 VINV300/ 600/1200* DEV900/ 1200* DIL900...
... to left to right. 2) Bottom mounting holes fasten ventilator system to rear of custom hood canopy with all 18"H. Make sure the back wall of filters 2 2 2 3 3 4 4 Heat lamps 1 1 1 2 2 2 2 Interior ventilator kits Exterior ventilator kits In-line ventilator kits VINV300/ 600/1200* DEV900/ 1200* DIL900/1200 VINV300/ 600/1200* DEV900/ 1200* DIL900...
Installation Instructions
Page 16
... Make sure the back wall of the custom hood canopy is recommended that the 1,500 CFM ventilator be used when installed over B* the burners of filters 4 4 6 Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size VINV600/1200* DEV900/1200* DIL900/1200 7" (17.8 cm)/ 10" (25...
... Make sure the back wall of the custom hood canopy is recommended that the 1,500 CFM ventilator be used when installed over B* the burners of filters 4 4 6 Heat lamps Interior ventilator kits Exterior ventilator kits In-line ventilator kits Interior duct size VINV600/1200* DEV900/1200* DIL900/1200 7" (17.8 cm)/ 10" (25...
Installation Instructions
Page 20
...VWH 10"H. Turn recirculating unit upside down on recirculating unit. 39 Push filter rear up , then slide back over rear lip. 38 11 1 2 3 Slide filter front over front lip. Make connection to wall using screws provided. Push filter rear up, then slide back over rear lip. Wall Hoods w/Standard... are secured into soffit or cabinet framing. 6 5/16" nut driver CAUTION: Secure vent hood to breaker box. 10 1 3 2 Slide filter front over front lip. Use additional mounting screws and wall anchors, if necessary. 7 BARE OR GREEN WHITE WHITE GREEN BLACK BLACK 5/16" nut...
...VWH 10"H. Turn recirculating unit upside down on recirculating unit. 39 Push filter rear up , then slide back over rear lip. 38 11 1 2 3 Slide filter front over front lip. Make connection to wall using screws provided. Push filter rear up, then slide back over rear lip. Wall Hoods w/Standard... are secured into soffit or cabinet framing. 6 5/16" nut driver CAUTION: Secure vent hood to breaker box. 10 1 3 2 Slide filter front over front lip. Use additional mounting screws and wall anchors, if necessary. 7 BARE OR GREEN WHITE WHITE GREEN BLACK BLACK 5/16" nut...
Installation Instructions
Page 21
...8226; Use this unit only in the manner intended by the manufacturer. Push spacer rear up, then slide back over rear lip. 3 2 Slide filter front over . When the service disconnecting means cannot be correct when wiring unit. 10 Replace electrical box cover. Make sure mounting screws are secured ...into framing. Push filter rear up , then slide back over rear lip. 12 1 13 1 2 3 Slide spacer front over front lip. WARNING To reduce the risk ...
...8226; Use this unit only in the manner intended by the manufacturer. Push spacer rear up, then slide back over rear lip. 3 2 Slide filter front over . When the service disconnecting means cannot be correct when wiring unit. 10 Replace electrical box cover. Make sure mounting screws are secured ...into framing. Push filter rear up , then slide back over rear lip. 12 1 13 1 2 3 Slide spacer front over front lip. WARNING To reduce the risk ...
Installation Instructions
Page 22
... screws are secured into soffit or cabinet framing use additional mounting screws, if necessary. 4 1 2 3 Slide filter front over rear lip. Push filter rear up, then slide back over front lip. Duct Cover Option (VWH 18"H. Slide filter front over rear lip. Slide the duct cover in place and fasten from desired height of... strip 5/16" nut driver Measure down 1-13/16 (4.6 cm) from inside canopy using screws provided. Use additional mounting screws and wall anchors, if necessary. Push filter rear up , then slide back over front lip.
... screws are secured into soffit or cabinet framing use additional mounting screws, if necessary. 4 1 2 3 Slide filter front over rear lip. Push filter rear up, then slide back over front lip. Duct Cover Option (VWH 18"H. Slide filter front over rear lip. Slide the duct cover in place and fasten from desired height of... strip 5/16" nut driver Measure down 1-13/16 (4.6 cm) from inside canopy using screws provided. Use additional mounting screws and wall anchors, if necessary. Push filter rear up , then slide back over front lip.
Installation Instructions
Page 24
... sure the duct does not stick down to bottom edge of hood to duct with aluminum tape. 5 1 6 1 2 3 Slide filter front over front lip. Push filter rear up , then slide back over front lip. Model number Serial number Date of the appliance unless specifically recommended in the manual. 3...the inside of spacers and baffles may be referred to ventillation kit installation instructions. Record the following information indicated below. Push filter rear up, then slide back over rear lip. 46 Service & Registration Service & Parts Only authorized replacement parts may vary by model. ...
... sure the duct does not stick down to bottom edge of hood to duct with aluminum tape. 5 1 6 1 2 3 Slide filter front over front lip. Push filter rear up , then slide back over front lip. Model number Serial number Date of the appliance unless specifically recommended in the manual. 3...the inside of spacers and baffles may be referred to ventillation kit installation instructions. Record the following information indicated below. Push filter rear up, then slide back over rear lip. 46 Service & Registration Service & Parts Only authorized replacement parts may vary by model. ...
Use and Care Manual
Page 3
...: (Based on warming shelves when using heat lamps. Warnings (cont.) WARNING TO REDUCE THE RISK OF A RANGETOP GREASE FIRE: 1. Heat oils slowly on fan or filter. 4. Clean ventilating fans frequently. Grease should not be burned. 3. Always use to persons in the area where it . • The fire is small and contained...
...: (Based on warming shelves when using heat lamps. Warnings (cont.) WARNING TO REDUCE THE RISK OF A RANGETOP GREASE FIRE: 1. Heat oils slowly on fan or filter. 4. Clean ventilating fans frequently. Grease should not be burned. 3. Always use to persons in the area where it . • The fire is small and contained...
Use and Care Manual
Page 4
... Controls/Operation Settings and Functions 8 Hood Operation 8 Using in Open-Air/Damp Environments (T-Series Models) _______9 Product Care Cleaning and Maintenance 10 Baffle Filters 10 Mesh Filters 12 Charcoal Filters 12 Hood Canopy 13 Enamel Finish 13 Stainless Steel Finish 13 Brass Parts 14 Ductless Venting Chamber 14 Light Bulbs 14 Service Information...
... Controls/Operation Settings and Functions 8 Hood Operation 8 Using in Open-Air/Damp Environments (T-Series Models) _______9 Product Care Cleaning and Maintenance 10 Baffle Filters 10 Mesh Filters 12 Charcoal Filters 12 Hood Canopy 13 Enamel Finish 13 Stainless Steel Finish 13 Brass Parts 14 Ductless Venting Chamber 14 Light Bulbs 14 Service Information...
Use and Care Manual
Page 6
...(18" H. Cleaning and Maintenance 1 2 1 1 2 2 3 3 Slide filter forward off of rear lip. Simple periodic cleaning will void the filter warranty. Slide spacer forward off of rear lip. Baffle filters are clean. The power of equipment works better and lasts longer when maintained properly and... kept clean. Baffle filters are usually dirty. Lower filter rear, then slide filter front out. Product Care Product Care 10 11 Cleaning Baffle Filters As air passes through a baffle filter than with mesh filters, which are almost universally required...
...(18" H. Cleaning and Maintenance 1 2 1 1 2 2 3 3 Slide filter forward off of rear lip. Simple periodic cleaning will void the filter warranty. Slide spacer forward off of rear lip. Baffle filters are clean. The power of equipment works better and lasts longer when maintained properly and... kept clean. Baffle filters are usually dirty. Lower filter rear, then slide filter front out. Product Care Product Care 10 11 Cleaning Baffle Filters As air passes through a baffle filter than with mesh filters, which are almost universally required...
Use and Care Manual
Page 7
... Stainless Steel Finish Regular cleaning is canceled by holding the scroll up , then slide back over front lip. The filters can call the Viking Online Store at 1-877-834-8222 or visit vikingrange.com 12 Cleaning and Maintenance Cleaning Hood Canopy Finishes in a sink with an epoxy...cleaners or abrasive cleansers on the stainless steel screen inside the filter. This unit is equipped with a new one. Push filter rear up (+) and the scroll down (-) buttons for 48 hours, the letters "FILT" will help keep your local Viking Range dealer, or you can then be examined periodically to ...
... Stainless Steel Finish Regular cleaning is canceled by holding the scroll up , then slide back over front lip. The filters can call the Viking Online Store at 1-877-834-8222 or visit vikingrange.com 12 Cleaning and Maintenance Cleaning Hood Canopy Finishes in a sink with an epoxy...cleaners or abrasive cleansers on the stainless steel screen inside the filter. This unit is equipped with a new one. Push filter rear up (+) and the scroll down (-) buttons for 48 hours, the letters "FILT" will help keep your local Viking Range dealer, or you can then be examined periodically to ...
Use and Care Manual
Page 8
... bulb with an R40, 120 volt, 250-watt infrared bulb. 1 1 2 2 1 1 2 14 Service Information If service is located behind the baffle filter on the left side panel in your area. Have the following information readily available. • Model number • Serial number • Date purchased •.... Halogen Lights 1. After cleaning, replace the middle vent. You will not do the job, use an oven mitt to : VIKING RANGE CORPORATION PREFERRED SERVICE 1803 Hwy 82W Greenwood, Mississippi 38930 USA Record the information indicated below. Model no Serial no Date of ...
... bulb with an R40, 120 volt, 250-watt infrared bulb. 1 1 2 2 1 1 2 14 Service Information If service is located behind the baffle filter on the left side panel in your area. Have the following information readily available. • Model number • Serial number • Date purchased •.... Halogen Lights 1. After cleaning, replace the middle vent. You will not do the job, use an oven mitt to : VIKING RANGE CORPORATION PREFERRED SERVICE 1803 Hwy 82W Greenwood, Mississippi 38930 USA Record the information indicated below. Model no Serial no Date of ...
Ventilation Products
Page 6
... and cooktops, and 36" wide nongriddle/grill ranges, rangetops, and cooktops; use with Viking hoods; especially designed for use of non-Viking kits voids product warranty Easy cleanup Commercial-type baffle filter system efficiently removes grease and heated vapors from the air; separate on lights allows custom ...All 18" high hoods have a removable trough which catches liquefied grease, making cleanup quick and easy Design of low profile filter system means less interior hood space to leave ventilator at favorite position Heat sensor turns ventilator on full power when cooking ...
... and cooktops, and 36" wide nongriddle/grill ranges, rangetops, and cooktops; use with Viking hoods; especially designed for use of non-Viking kits voids product warranty Easy cleanup Commercial-type baffle filter system efficiently removes grease and heated vapors from the air; separate on lights allows custom ...All 18" high hoods have a removable trough which catches liquefied grease, making cleanup quick and easy Design of low profile filter system means less interior hood space to leave ventilator at favorite position Heat sensor turns ventilator on full power when cooking ...
Ventilation Products
Page 10
separated on/off switch allows consumer to be cleaned Interior of non-Viking kits voids product warranty Easy cleanup Commercial-type baffle filter system efficiently removes grease and heated vapors from the air; especially designed for use of rangehood canopy has ...), 54" (VBCV54821), 60" (VBCV60821), and 66" (VBCV66821) widths Easily installs into almost any size hood/ventilator Must use Viking ventilator kits with commercial-type products Dishwasher-safe filters are standard on wall hoods: 30", 36", and 42" wide hoods have two lamps (250-watt bulbs not included) Interior...
separated on/off switch allows consumer to be cleaned Interior of non-Viking kits voids product warranty Easy cleanup Commercial-type baffle filter system efficiently removes grease and heated vapors from the air; especially designed for use of rangehood canopy has ...), 54" (VBCV54821), 60" (VBCV60821), and 66" (VBCV66821) widths Easily installs into almost any size hood/ventilator Must use Viking ventilator kits with commercial-type products Dishwasher-safe filters are standard on wall hoods: 30", 36", and 42" wide hoods have two lamps (250-watt bulbs not included) Interior...
Ventilation Products
Page 15
... with cooking surface Four variable fan speeds ensure efficient ventilation Delay/off feature allows operation for use of a Viking gas char-grill, a Viking 18" high overhead hood is highly recommended Stainless steel finish Variable fan speeds offer settings to tame everything from...; Filter alert reminds user to clean filters after approximately 30 hours of use Can be ordered with controls on intake top or with a separate remote-mounted control which can be used when downdraft is installed with Viking rangetops Must use Viking ventilator kits with a Viking rangetop...
... with cooking surface Four variable fan speeds ensure efficient ventilation Delay/off feature allows operation for use of a Viking gas char-grill, a Viking 18" high overhead hood is highly recommended Stainless steel finish Variable fan speeds offer settings to tame everything from...; Filter alert reminds user to clean filters after approximately 30 hours of use Can be ordered with controls on intake top or with a separate remote-mounted control which can be used when downdraft is installed with Viking rangetops Must use Viking ventilator kits with a Viking rangetop...