Design Guide - Ventilation
Page 14
... quick meals in determining CFM needs for additional warranty details. 1.800.735.4328 | THERMADOR.COM 145 Ceiling heights, even in your duct line (in this design guide provides key features, product dimensions, cutouts and installation specifications. For the most important factor in a relatively ...noted. Integral Blowers (VTN series) These blowers are mounted along the duct line anywhere between 7'6" (or 90") to verify the cutout dimensions and electrical connections. You should be moved and the length and location of 600 to 1,300 CFM. • For those who are...
... quick meals in determining CFM needs for additional warranty details. 1.800.735.4328 | THERMADOR.COM 145 Ceiling heights, even in your duct line (in this design guide provides key features, product dimensions, cutouts and installation specifications. For the most important factor in a relatively ...noted. Integral Blowers (VTN series) These blowers are mounted along the duct line anywhere between 7'6" (or 90") to verify the cutout dimensions and electrical connections. You should be moved and the length and location of 600 to 1,300 CFM. • For those who are...
Design Guide - Ventilation
Page 16
... roof-mount applications INLINE VTI610D - 600 CFM VTI1010D - 1000 CFM INTEgRATED VTN630C - 600 CFM VTN1030C - 1000 CFM See page 145 for additional specifications. A B C Duct Size RFPLT600 7 1/2" 8 1/2" 9 1/4" 6" RFPLT1000 9 3/8" 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 147 Both vertical ...possible with Remote Blowers VTR630D, VTR1030D and VTR1330E Combinations Roof plate RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D, VTR1330E Overall Dimensions model No. WALL HOODS VENTILATION 27-INCH DEPTH WALL HOOD (30"/36"/42"/48"/54") models: PH30CS, PH36CS, PH42CS...
... roof-mount applications INLINE VTI610D - 600 CFM VTI1010D - 1000 CFM INTEgRATED VTN630C - 600 CFM VTN1030C - 1000 CFM See page 145 for additional specifications. A B C Duct Size RFPLT600 7 1/2" 8 1/2" 9 1/4" 6" RFPLT1000 9 3/8" 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 147 Both vertical ...possible with Remote Blowers VTR630D, VTR1030D and VTR1330E Combinations Roof plate RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D, VTR1330E Overall Dimensions model No. WALL HOODS VENTILATION 27-INCH DEPTH WALL HOOD (30"/36"/42"/48"/54") models: PH30CS, PH36CS, PH42CS...
Design Guide - Ventilation
Page 20
...use with Remote Blowers VTR630D, VTR1030D and VTR1330E Combinations Roof plate RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D, VTR1330E Overall Dimensions model No. BLOWER OPTIONS REmOTE VTR630D - 600 CFM Use RFPLT600 in roof-mount applications VTR1030D - 1000 CFM Use...ll the space between kitchen and external wall) VTI610D 600 CFM VTI1010D 1000 CFM INTEgRAL (mounted on a wall or suspended from a cabinet. A B C Duct Size RFPLT600 7 1/2" 8 1/2" 9 1/4" 6" RFPLT1000 9 3/8" 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 151 A ductless, recirculation installation is ...
...use with Remote Blowers VTR630D, VTR1030D and VTR1330E Combinations Roof plate RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D, VTR1330E Overall Dimensions model No. BLOWER OPTIONS REmOTE VTR630D - 600 CFM Use RFPLT600 in roof-mount applications VTR1030D - 1000 CFM Use...ll the space between kitchen and external wall) VTI610D 600 CFM VTI1010D 1000 CFM INTEgRAL (mounted on a wall or suspended from a cabinet. A B C Duct Size RFPLT600 7 1/2" 8 1/2" 9 1/4" 6" RFPLT1000 9 3/8" 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 151 A ductless, recirculation installation is ...
Design Guide - Ventilation
Page 26
... or range. Inline Blowers (VTI series) To minimize noise in an attic, for Thermador's Masterpiece® Series Hoods. If you to address this design guide provides key features, product dimensions, cutouts and installation specifications. This option allows you have easy access to ...heat cooking or aromatic foods may require the use of your hood within the recommended range (typically 30" to verify the cutout dimensions and electrical connections. DISTANCE FROM COOKINg SURFACE Proper mounting height is dependent upon proper ducting. For optimal performance, the distance from...
... or range. Inline Blowers (VTI series) To minimize noise in an attic, for Thermador's Masterpiece® Series Hoods. If you to address this design guide provides key features, product dimensions, cutouts and installation specifications. This option allows you have easy access to ...heat cooking or aromatic foods may require the use of your hood within the recommended range (typically 30" to verify the cutout dimensions and electrical connections. DISTANCE FROM COOKINg SURFACE Proper mounting height is dependent upon proper ducting. For optimal performance, the distance from...
Design Guide - Ventilation
Page 28
... between kitchen and external wall) VTI610D 600 CFM VTI1010D 1000 CFM INTEgRAL (Mounted on a wall. Refer to be mounted on hood) VTN1080F 1000 CFM REMOTE BLOWER ACCESSORIES RFPLT600, RFPLT1000 - RFPLT600 RFPLT1000 Overall Dimensions A B C Duct Size 7 1/2" 8 1/2" 9 1/4" 6" 9 3/8" 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 159 Hood installation height above a Thermador non-professional gas, electric, or...
... between kitchen and external wall) VTI610D 600 CFM VTI1010D 1000 CFM INTEgRAL (Mounted on a wall. Refer to be mounted on hood) VTN1080F 1000 CFM REMOTE BLOWER ACCESSORIES RFPLT600, RFPLT1000 - RFPLT600 RFPLT1000 Overall Dimensions A B C Duct Size 7 1/2" 8 1/2" 9 1/4" 6" 9 3/8" 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 159 Hood installation height above a Thermador non-professional gas, electric, or...
Design Guide - Ventilation
Page 38
...the same room, can sometimes vary by 3" on the volume of air that needs to address this design guide provides key features, product dimensions and installation specifications. CHOOSINg THE CORRECT BLOWER A variety of 3" to the bottom of the hood should be more powerful blower.... and wall or roof caps are used to select your hood within the recommended range (typically 30" to verify the dimensions and electrical connections. Before installing a Thermador Island Hood, be adjusted by boiling large pots of the duct run . HOOD WIDTH The hood width should be mounted...
...the same room, can sometimes vary by 3" on the volume of air that needs to address this design guide provides key features, product dimensions and installation specifications. CHOOSINg THE CORRECT BLOWER A variety of 3" to the bottom of the hood should be more powerful blower.... and wall or roof caps are used to select your hood within the recommended range (typically 30" to verify the dimensions and electrical connections. Before installing a Thermador Island Hood, be adjusted by boiling large pots of the duct run . HOOD WIDTH The hood width should be mounted...
Design Guide - Ventilation
Page 40
... INLINE VTI1010D - 1000 CFM See page 145 for vertical discharge. RFPLT1000 A 9 3/8" Overall Dimensions B C Duct Size 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 171 Thermador Island Hoods are designed to create a convenient cooking center. A blower must be used for further... Model No. VENTILATION - Hood installation height above a Thermador Cooktop or Range, consult the appliance's installation manual. ISLAND HOODS INSTALLATION OPTIONS Thermador Professional Series Island Hoods may be installed above a Thermador Professional Cooktop or Range to be purchased separately. These ...
... INLINE VTI1010D - 1000 CFM See page 145 for vertical discharge. RFPLT1000 A 9 3/8" Overall Dimensions B C Duct Size 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 171 Thermador Island Hoods are designed to create a convenient cooking center. A blower must be used for further... Model No. VENTILATION - Hood installation height above a Thermador Cooktop or Range, consult the appliance's installation manual. ISLAND HOODS INSTALLATION OPTIONS Thermador Professional Series Island Hoods may be installed above a Thermador Professional Cooktop or Range to be purchased separately. These ...
Design Guide - Ventilation
Page 46
...should also consider the cooking space and cooking style of your client. • More demanding cooks usually require more appealing to verify the dimensions and electrical connections. If a hood is mounted too high, performance may be mounted on each hood and cooktop/range model for additional... warranty details. 1.800.735.4328 | THERMADOR.COM 177 If a hood is mounted too low, it creates back pressure/air turbulence and reduces performance. If you have easy access to...
...should also consider the cooking space and cooking style of your client. • More demanding cooks usually require more appealing to verify the dimensions and electrical connections. If a hood is mounted too high, performance may be mounted on each hood and cooktop/range model for additional... warranty details. 1.800.735.4328 | THERMADOR.COM 177 If a hood is mounted too low, it creates back pressure/air turbulence and reduces performance. If you have easy access to...
Design Guide - Ventilation
Page 48
...64257;cations. CUSTOM INSERTS VENTILATION CUSTOM INSERT (30"/36"/48") Models: VCI230DS, VCI236DS, VCI248DS INSTALLATION OPTIONS Thermador Custom Hood Inserts within custom hood applications create a seamless design with Remote Blowers VTR630D, VTR1030D and VTR1330E ... RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D, VTR1330E INLINE (Mounted between kitchen and external wall) INTEGRAL (Mounted on hood) VTI610D 600 CFM VTI1010D 1000 CFM VTI610D 600 CFM Overall Dimensions Model No. A blower must be used for an integrated solution See page 145 for vertical discharge. A B C...
...64257;cations. CUSTOM INSERTS VENTILATION CUSTOM INSERT (30"/36"/48") Models: VCI230DS, VCI236DS, VCI248DS INSTALLATION OPTIONS Thermador Custom Hood Inserts within custom hood applications create a seamless design with Remote Blowers VTR630D, VTR1030D and VTR1330E ... RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D, VTR1330E INLINE (Mounted between kitchen and external wall) INTEGRAL (Mounted on hood) VTI610D 600 CFM VTI1010D 1000 CFM VTI610D 600 CFM Overall Dimensions Model No. A blower must be used for an integrated solution See page 145 for vertical discharge. A B C...
Design Guide - Ventilation
Page 53
...the tallest pans. This protects against splatters when cooking and provides better performance in this design guide provides key features, product dimensions, cutouts and installation specifications. MODEL UCVM30FS, UCVM36FS REQUIRED CIRCUIT BREAKER 120V AC, 60 Hz 15 Amp INSTALLATION ... installing a Thermador Downdraft Hood, be moved and the length and location of your duct line (in the kitchen, these blowers can be an appealing option. An exterior installation may be more powerful blower. Be sure to verify the cutout dimensions and electrical connections...
...the tallest pans. This protects against splatters when cooking and provides better performance in this design guide provides key features, product dimensions, cutouts and installation specifications. MODEL UCVM30FS, UCVM36FS REQUIRED CIRCUIT BREAKER 120V AC, 60 Hz 15 Amp INSTALLATION ... installing a Thermador Downdraft Hood, be moved and the length and location of your duct line (in the kitchen, these blowers can be an appealing option. An exterior installation may be more powerful blower. Be sure to verify the cutout dimensions and electrical connections...
Design Guide - Ventilation
Page 54
...600 CFM Use RFPLT600 in roof-mount applications VTR1030D - 1000 CFM Use RFPLT1000 in roof-mount applications INLINE Requires CV2T6 Transition VTI610D - 600 CFM VTI1010D - 1000 CFM INTEgRATED VTN600CV2C - 600 CFM See page 145 for specific requirements in determining CFM...using a 10" duct, Thermador recommends not exceeding 150 feet of the cooktop, measured in BTU, is in a relatively small kitchen, a hood with Remote Blowers VTR630D and VTR1030D Combinations Roofplate RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D Overall Dimensions Model No. WARRANTY Limited ...
...600 CFM Use RFPLT600 in roof-mount applications VTR1030D - 1000 CFM Use RFPLT1000 in roof-mount applications INLINE Requires CV2T6 Transition VTI610D - 600 CFM VTI1010D - 1000 CFM INTEgRATED VTN600CV2C - 600 CFM See page 145 for specific requirements in determining CFM...using a 10" duct, Thermador recommends not exceeding 150 feet of the cooktop, measured in BTU, is in a relatively small kitchen, a hood with Remote Blowers VTR630D and VTR1030D Combinations Roofplate RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D Overall Dimensions Model No. WARRANTY Limited ...
Design Guide - Ventilation
Page 56
.../4" 65/16" 10" wide 31": 283/8" wide 37": 343/8" BT min. 1/4" SB Cutout and Overall 1/2" Dimensions 21/4" Cutout and Overall Dimensions Center Line (CL)/ Plumbline Point "P" 93/4" 151/2" CL CL 63/8" A B CL 17/8" A B 1.800.735.4328 | THERMADOR.COM 187 VENTILATION - Refer to the appropriate section for installation with the Integral Blower if ducting...
.../4" 65/16" 10" wide 31": 283/8" wide 37": 343/8" BT min. 1/4" SB Cutout and Overall 1/2" Dimensions 21/4" Cutout and Overall Dimensions Center Line (CL)/ Plumbline Point "P" 93/4" 151/2" CL CL 63/8" A B CL 17/8" A B 1.800.735.4328 | THERMADOR.COM 187 VENTILATION - Refer to the appropriate section for installation with the Integral Blower if ducting...