Design Guide - Electric Cooktops
Page 4
... the bottom of Masterpiece® Electric Cooktops to verify the cutout dimensions and electrical connections. Before installing a Thermador Masterpiece Electric Cooktop, be connected to the ventilation section for complete details before installing. eLeCTrICAL SPeCIFICATIONS Be sure your.... Solid surface countertops require a special cutout size and installation. COOKTOPS - Thermador Masterpiece Electric Cooktops may be located within 3 feet (~900 mm) of the oven. mODeL CEM304FS CES304FS CET304FS CEM365FS CES365FS CES366FS CET366FS reQuIreD CIrCuIT breAKer 240V, 3 Wire, 60...
... the bottom of Masterpiece® Electric Cooktops to verify the cutout dimensions and electrical connections. Before installing a Thermador Masterpiece Electric Cooktop, be connected to the ventilation section for complete details before installing. eLeCTrICAL SPeCIFICATIONS Be sure your.... Solid surface countertops require a special cutout size and installation. COOKTOPS - Thermador Masterpiece Electric Cooktops may be located within 3 feet (~900 mm) of the oven. mODeL CEM304FS CES304FS CET304FS CEM365FS CES365FS CES366FS CET366FS reQuIreD CIrCuIT breAKer 240V, 3 Wire, 60...
Design Guide - Electric Cooktops
Page 5
...when elements are still hot CeT304FS PerFOrmANCe - COOKTOPS 30-INCh eLeCTrIC models: Cem304FS, CeT304FS mASTerPIeCe CEM304FS Mechanical Controls mASTerPIeCe CET304FS Touch Controls SPeCIFICATIONS Total Number of Cooktop Elements Product... Rear Wall Left Front Element Right Front Element Left Rear Element Right Rear Element Center Element Electrical Supply Required Circuit Breaker Conduit Shipping Weight (lbs.) CEM304FS CET304FS 4 31" 21 1/4" 28 3/4" - 28 7/8" 3 15/16" 1/4" 19 7/8" - 20" 2 1/4" 2 3/4" 6" @ 1,200W 7" @ 1,800W 5" / 7" @ 700 / 1,700 W 6" / 9" @ 1,100 / 2,500 W 5" /...
...when elements are still hot CeT304FS PerFOrmANCe - COOKTOPS 30-INCh eLeCTrIC models: Cem304FS, CeT304FS mASTerPIeCe CEM304FS Mechanical Controls mASTerPIeCe CET304FS Touch Controls SPeCIFICATIONS Total Number of Cooktop Elements Product... Rear Wall Left Front Element Right Front Element Left Rear Element Right Rear Element Center Element Electrical Supply Required Circuit Breaker Conduit Shipping Weight (lbs.) CEM304FS CET304FS 4 31" 21 1/4" 28 3/4" - 28 7/8" 3 15/16" 1/4" 19 7/8" - 20" 2 1/4" 2 3/4" 6" @ 1,200W 7" @ 1,800W 5" / 7" @ 700 / 1,700 W 6" / 9" @ 1,100 / 2,500 W 5" /...
Design Guide - Electric Cooktops
Page 6
...the top of the cutout to create a convenient cooking center. ImPOrTANT We strongly recommend the installation of the oven. 1.800.735.4328 | THERMADOR.COM 125 INSTALLATION ABOVE A THERMADOR BUILT-IN OVEN 415/16" (125 mm) 3 15/16" 4 3/16" (100mm) (106 mm) 6 3/4" (172 mm) ...Fitting / Conduit 36" (914 mm) COOKTOP SUMP 1/4" 113/16" (7mm) (47mm) OVEN 281/4" (718mm) 24 7/16" (621mm) 271/16" (687 mm) COUNTERTOP 3 "(76mm) 29 1/16" (738 mm) COOKTOPS 30-INCh eLeCTrIC models: Cem304FS...
...the top of the cutout to create a convenient cooking center. ImPOrTANT We strongly recommend the installation of the oven. 1.800.735.4328 | THERMADOR.COM 125 INSTALLATION ABOVE A THERMADOR BUILT-IN OVEN 415/16" (125 mm) 3 15/16" 4 3/16" (100mm) (106 mm) 6 3/4" (172 mm) ...Fitting / Conduit 36" (914 mm) COOKTOP SUMP 1/4" 113/16" (7mm) (47mm) OVEN 281/4" (718mm) 24 7/16" (621mm) 271/16" (687 mm) COUNTERTOP 3 "(76mm) 29 1/16" (738 mm) COOKTOPS 30-INCh eLeCTrIC models: Cem304FS...
Installation Instructions
Page 5
... countertop manufacturer for instructions specific to make them heatĆresistant. Seal the cutout surfaces to your countertop. 5 Preparation Countertop requirements Note 30" Model: CES304FS CET304FS CEM304FS ř WARNING:ĄTo reduce the risk of ignition of moisture. For example, heat reflective tape and rounded corners may be guaranteed after the cutout...
... countertop manufacturer for instructions specific to make them heatĆresistant. Seal the cutout surfaces to your countertop. 5 Preparation Countertop requirements Note 30" Model: CES304FS CET304FS CEM304FS ř WARNING:ĄTo reduce the risk of ignition of moisture. For example, heat reflective tape and rounded corners may be guaranteed after the cutout...
Installation Instructions
Page 10
... Electrical connection 10 You can find the identification plate with the electrical specifications on accidently. The junctionbox must be easily accessible for service purposes. Model CEM304FS CET304FS CES304FS CEM365FS CET366FS CES366FS CES365FS 240 V AC, 60 Hz system: circuit breaker 40 Amp 40 Amp 40 Amp 40 Amp 50 Amp 50 Amp 50...
... Electrical connection 10 You can find the identification plate with the electrical specifications on accidently. The junctionbox must be easily accessible for service purposes. Model CEM304FS CET304FS CES304FS CEM365FS CET366FS CES366FS CES365FS 240 V AC, 60 Hz system: circuit breaker 40 Amp 40 Amp 40 Amp 40 Amp 50 Amp 50 Amp 50...
User Manual
Page 33
... our Customer Service department if your registration card; D New at all times remained within the country of Limited Product Warranty applies only to the Thermador CEM304FS, CEM365FS, CET304FS, CET366FS, CES304FS, CES365FS, CES366FS ("Product") sold to return your appliance needs repair. while not necessary to effectuate warranty coverage, it Applies to The limited warranty...
... our Customer Service department if your registration card; D New at all times remained within the country of Limited Product Warranty applies only to the Thermador CEM304FS, CEM365FS, CET304FS, CET366FS, CES304FS, CES365FS, CES366FS ("Product") sold to return your appliance needs repair. while not necessary to effectuate warranty coverage, it Applies to The limited warranty...