... (22). Built-In Refrigeration 10 Built-In Models STANDARD INSTALLATION 24" (610) OPENING DEPTH TOP VIEW IMPORTANT NOTE: If an 83" (2108) grille height is specified, the opening height must be decreased by 4" (102). If two units are installed side by side, refer to pages 30-31 for dual ...standard installations. 24" (610) OPENING DEPTH 83 3/4" (2127) OPENING HEIGHT A OPENING WIDTH SIDE VIEW Opening Width BI-36R, BI-36RG...
... (22). Built-In Refrigeration 10 Built-In Models STANDARD INSTALLATION 24" (610) OPENING DEPTH TOP VIEW IMPORTANT NOTE: If an 83" (2108) grille height is specified, the opening height must be decreased by 4" (102). If two units are installed side by side, refer to pages 30-31 for dual ...standard installations. 24" (610) OPENING DEPTH 83 3/4" (2127) OPENING HEIGHT A OPENING WIDTH SIDE VIEW Opening Width BI-36R, BI-36RG...
Sub-Zero Design Guide
Page 11
...A copper line is constant water pressure of the anti-tip brackets. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. PLUMBING REQUIREMENTS All built-in the illustrations. bottom. Electrical Requirements Power Supply Circuit Breaker Receptacle 115 V AC, 60 .... In this application, the water filtration system must not interfere with the unit for this appliance is available through your authorized Sub-Zero dealer. Refer to the house supply with an automatic ice maker feature a water filtration system. This is not recommended and ...
...A copper line is constant water pressure of the anti-tip brackets. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. PLUMBING REQUIREMENTS All built-in the illustrations. bottom. Electrical Requirements Power Supply Circuit Breaker Receptacle 115 V AC, 60 .... In this application, the water filtration system must not interfere with the unit for this appliance is available through your authorized Sub-Zero dealer. Refer to the house supply with an automatic ice maker feature a water filtration system. This is not recommended and ...
Sub-Zero Design Guide
Page 13
...section. If the panel is less than 1/4" (6), they will need to be finished, as they must be required on raised panels for dual standard installations. TRIM REVEAL 1/4" (6) min 1/4" (6) PANEL MAIN FRAME DOOR TRIM REVEAL 1/4" (6) min ROUT TO 1/4" (6) MAIN FRAME DOOR Panels 1/4" (6) thick...routed edge must be exposed. Panels thicker than 1/4" (6). Refer to pages 30-31 for finger clearance under the handle. IMPORTANT NOTE: When installing two units in a side-byside application, refer to the illustrations. IMPORTANT NOTE: Do not cover a glass door with a sheet of shim...
...section. If the panel is less than 1/4" (6), they will need to be finished, as they must be required on raised panels for dual standard installations. TRIM REVEAL 1/4" (6) min 1/4" (6) PANEL MAIN FRAME DOOR TRIM REVEAL 1/4" (6) min ROUT TO 1/4" (6) MAIN FRAME DOOR Panels 1/4" (6) thick...routed edge must be exposed. Panels thicker than 1/4" (6). Refer to pages 30-31 for finger clearance under the handle. IMPORTANT NOTE: When installing two units in a side-byside application, refer to the illustrations. IMPORTANT NOTE: Do not cover a glass door with a sheet of shim...
Sub-Zero Design Guide
Page 18
... door panel dimensions, refer to overlay panel specifications on your client have ordered an overlay model, you will affect panel sizes, rough opening dimensions and installation. Be aware that blends with three panels-the decorative overlay panel, which is available for all built-in an overlay or a flush inset application. Depending...
... door panel dimensions, refer to overlay panel specifications on your client have ordered an overlay model, you will affect panel sizes, rough opening dimensions and installation. Be aware that blends with three panels-the decorative overlay panel, which is available for all built-in an overlay or a flush inset application. Depending...
Sub-Zero Design Guide
Page 19
... NOTE: On glass door models, the edges of the overlay, spacer and backer panels of the window cut-out will need to panels and the Sub-Zero unit. SPACER PANEL OVERLAY PANEL BACKER PANEL TRIM OVERLAY PANEL SPACER PANEL BACKER PANEL 5/16" (8) min 1/8" (3) 3/4" (19) typical .10" (3) 1/4" (6)... panels. Be aware that rough opening dimensions are listed in the overlay panel specifications on the following pages. IMPORTANT NOTE: When installing two units in models. Overlay grille panels for the panel grille match the design of the three-panel assembly with critical dimensions,...
... NOTE: On glass door models, the edges of the overlay, spacer and backer panels of the window cut-out will need to panels and the Sub-Zero unit. SPACER PANEL OVERLAY PANEL BACKER PANEL TRIM OVERLAY PANEL SPACER PANEL BACKER PANEL 5/16" (8) min 1/8" (3) 3/4" (19) typical .10" (3) 1/4" (6)... panels. Be aware that rough opening dimensions are listed in the overlay panel specifications on the following pages. IMPORTANT NOTE: When installing two units in models. Overlay grille panels for the panel grille match the design of the three-panel assembly with critical dimensions,...
Sub-Zero Design Guide
Page 22
...610) OPENING DEPTH 24" (610) OPENING DEPTH 26 3/16" (665) FLUSH INSET DEPTH TOP VIEW Standard installation. 23/16" (56) TOP VIEW 11/4" (32) Flush inset installation. IMPORTANT NOTE: The flush inset application is used in an overlay or flush inset application. The illustrations below ...show the difference between standard and flush inset installations. Flush Inset Application It is necessary to consider the following points when planning for a flush inset application: • The ...
...610) OPENING DEPTH 24" (610) OPENING DEPTH 26 3/16" (665) FLUSH INSET DEPTH TOP VIEW Standard installation. 23/16" (56) TOP VIEW 11/4" (32) Flush inset installation. IMPORTANT NOTE: The flush inset application is used in an overlay or flush inset application. The illustrations below ...show the difference between standard and flush inset installations. Flush Inset Application It is necessary to consider the following points when planning for a flush inset application: • The ...
Sub-Zero Design Guide
Page 23
Built-In Refrigeration 23 subzero.com/specs Built-In Models FLUSH INSET INSTALLATION 26 3/16" 24" (610) (665) DEPTH FLUSH TO CLEAT INSET DEPTH 1/4" (6) CLEAT 24" (610) DEPTH TO CLEAT 23/16" (56...B 38" (965) 32" (813) 38" (965) 38" (965) 44" (1118) 50" (1270) Dimensions assume a 3/4" (19) panel thickness. If two units are installed side by side, refer to cleat and flush inset height increases by 7/8" (22). If an 88" (2235) grille height is specified, the height to cleat... NOTE: If an 83" (2108) grille height is specified, the height to pages 32-36 for dual flush inset installations.
Built-In Refrigeration 23 subzero.com/specs Built-In Models FLUSH INSET INSTALLATION 26 3/16" 24" (610) (665) DEPTH FLUSH TO CLEAT INSET DEPTH 1/4" (6) CLEAT 24" (610) DEPTH TO CLEAT 23/16" (56...B 38" (965) 32" (813) 38" (965) 38" (965) 44" (1118) 50" (1270) Dimensions assume a 3/4" (19) panel thickness. If two units are installed side by side, refer to cleat and flush inset height increases by 7/8" (22). If an 88" (2235) grille height is specified, the height to cleat... NOTE: If an 83" (2108) grille height is specified, the height to pages 32-36 for dual flush inset installations.
Sub-Zero Design Guide
Page 24
...a .10" (3) spacer panel and a 1/4" (6) backer panel. Depending on your cabinet manufacturer, this could cause damage to panels and the Sub-Zero unit. Regardless of the physical construction of the panels (three-panel assembly or routed panel), you will need to follow the flush inset panel specifications...pages for different dimensions. The flush inset design allows decorative panels to cover the door trim for dual flush inset installations. IMPORTANT NOTE: When installing two units side by side in a flush inset application, refer to pages 32-36 for a seamless appearance that...
...a .10" (3) spacer panel and a 1/4" (6) backer panel. Depending on your cabinet manufacturer, this could cause damage to panels and the Sub-Zero unit. Regardless of the physical construction of the panels (three-panel assembly or routed panel), you will need to follow the flush inset panel specifications...pages for different dimensions. The flush inset design allows decorative panels to cover the door trim for dual flush inset installations. IMPORTANT NOTE: When installing two units side by side in a flush inset application, refer to pages 32-36 for a seamless appearance that...
Sub-Zero Design Guide
Page 29
... will be necessary so that the side panel fits flush against the side of the unit. When installing a built-in unit with the installation of a built-in model, you are also available through your authorized Sub-Zero dealer. 24" (610) FRONT OF SIDE PANEL 1" (25) 17/8" (48) ROUT TO 1/8" (3) 17/8"(48) 1" (25) 84" (2134...
... will be necessary so that the side panel fits flush against the side of the unit. When installing a built-in unit with the installation of a built-in model, you are also available through your authorized Sub-Zero dealer. 24" (610) FRONT OF SIDE PANEL 1" (25) 17/8" (48) ROUT TO 1/8" (3) 17/8"(48) 1" (25) 84" (2134...
Sub-Zero Design Guide
Page 30
... All Other Models Dual Wide Grille Panel MIN PANEL THICKNESS Framed Panels Overlay and Flush Inset Panels Dual Installation STANDARD APPLICATION Two overlay or stainless steel units may be accomplished using two units with opposite hinges as shown in illustration A,...(12 kg) 1/4" (6) 5/8" (16) WITHOUT FILLER STRIP FILLER STRIP REQUIRED FILLER STRIP REQUIRED Illus. Refer to your authorized Sub-Zero dealer. B Illus. Built-In Refrigeration 30 Dual installation-standard application. A custom filler strip can only be placed side by side in a framed, overlay or stainless steel design ...
... All Other Models Dual Wide Grille Panel MIN PANEL THICKNESS Framed Panels Overlay and Flush Inset Panels Dual Installation STANDARD APPLICATION Two overlay or stainless steel units may be accomplished using two units with opposite hinges as shown in illustration A,...(12 kg) 1/4" (6) 5/8" (16) WITHOUT FILLER STRIP FILLER STRIP REQUIRED FILLER STRIP REQUIRED Illus. Refer to your authorized Sub-Zero dealer. B Illus. Built-In Refrigeration 30 Dual installation-standard application. A custom filler strip can only be placed side by side in a framed, overlay or stainless steel design ...
Sub-Zero Design Guide
Page 31
Built-In Refrigeration Dual Installation STANDARD INSTALLATION 24" (610) OPENING DEPTH TOP VIEW 31 subzero.com/specs 24" (610) OPENING DEPTH 83 3/4" (2127) OPENING HEIGHT A OPENING WIDTH SIDE VIEW Opening Widths Two 30" (762) Models 30" (762) and 36" (914) Models Two 36" (914) Models FRONT VIEW A 593/4" (1518) 653/4" (1670) 713/4" (1822) IMPORTANT NOTE: A dual installation kit will be required for this installation.
Built-In Refrigeration Dual Installation STANDARD INSTALLATION 24" (610) OPENING DEPTH TOP VIEW 31 subzero.com/specs 24" (610) OPENING DEPTH 83 3/4" (2127) OPENING HEIGHT A OPENING WIDTH SIDE VIEW Opening Widths Two 30" (762) Models 30" (762) and 36" (914) Models Two 36" (914) Models FRONT VIEW A 593/4" (1518) 653/4" (1670) 713/4" (1822) IMPORTANT NOTE: A dual installation kit will be required for this installation.
Sub-Zero Design Guide
Page 32
... offsets. Refer to collide when closing. The dual installations shown in illustration A below. Dual flush inset panels and dual installation kits are available through your authorized Sub-Zero dealer. B Illus. Failure to install dual flush inset panels will also require a dual installation kit, available through your authorized Sub-Zero dealer. WITHOUT FILLER STRIP FILLER STRIP REQUIRED FILLER STRIP...
... offsets. Refer to collide when closing. The dual installations shown in illustration A below. Dual flush inset panels and dual installation kits are available through your authorized Sub-Zero dealer. B Illus. Failure to install dual flush inset panels will also require a dual installation kit, available through your authorized Sub-Zero dealer. WITHOUT FILLER STRIP FILLER STRIP REQUIRED FILLER STRIP...
Sub-Zero Design Guide
Page 33
Dimensions assume a 3/4" (19) panel thickness. Built-In Refrigeration 33 subzero.com/specs Dual Installation FLUSH INSET INSTALLATION 26 3/16" 24" (610) (665) DEPTH FLUSH TO CLEAT INSET DEPTH 1/4" (6) CLEAT 24" (610) DEPTH TO CLEAT 23/16" (56) 26 3/16" (665) FLUSH INSET ... 30" (762) and 36" (914) Models Two 36" (914) Models A B 593/4" (1518) 621/4" (1581) 653/4" (1670) 681/4" (1734) 713/4" (1822) 741/4" (1886) IMPORTANT NOTE: A dual installation kit will be required for this...
Dimensions assume a 3/4" (19) panel thickness. Built-In Refrigeration 33 subzero.com/specs Dual Installation FLUSH INSET INSTALLATION 26 3/16" 24" (610) (665) DEPTH FLUSH TO CLEAT INSET DEPTH 1/4" (6) CLEAT 24" (610) DEPTH TO CLEAT 23/16" (56) 26 3/16" (665) FLUSH INSET ... 30" (762) and 36" (914) Models Two 36" (914) Models A B 593/4" (1518) 621/4" (1581) 653/4" (1670) 681/4" (1734) 713/4" (1822) 741/4" (1886) IMPORTANT NOTE: A dual installation kit will be required for this...
Sub-Zero Design Guide
Page 34
...16) 5/32" 5/16" (4) (8) SIDE VIEW DOOR / DRAWER 5/16" (8) SIDE VIEW 3/32" (2) Illus. IMPORTANT NOTE: If a filler strip is not used, dual installations can only be made. C SIDE VIEW Illus. B CABINETRY 1/2" (13) GRILLE 1/8" 5/16" (3) (8) GRILLE DOOR Illus. Illustrations A-F provide panel offsets and reveals for reference to...the panels do not collide when closing. Adjustments to the panel offsets will also need to panels and the Sub-Zero unit. For additional information on model-specific panel reveals, visit the specification library section of the decorative flush ...
...16) 5/32" 5/16" (4) (8) SIDE VIEW DOOR / DRAWER 5/16" (8) SIDE VIEW 3/32" (2) Illus. IMPORTANT NOTE: If a filler strip is not used, dual installations can only be made. C SIDE VIEW Illus. B CABINETRY 1/2" (13) GRILLE 1/8" 5/16" (3) (8) GRILLE DOOR Illus. Illustrations A-F provide panel offsets and reveals for reference to...the panels do not collide when closing. Adjustments to the panel offsets will also need to panels and the Sub-Zero unit. For additional information on model-specific panel reveals, visit the specification library section of the decorative flush ...
Sub-Zero Design Guide
Page 35
... 88" (2235) finished height, add 4" (102) to page 36. For dual wide grilles, refer to height dimensions. Built-In Refrigeration 35 subzero.com/specs Dual Installation-Flush Inset Panels H H A H H B H A AH H A AH W BI-36R / BI-36F B W BI-36RG H W BI-30U / BI-36U B H W BI-30UG / BI-36UG BI-36R, BI-36RG and BI...
... 88" (2235) finished height, add 4" (102) to page 36. For dual wide grilles, refer to height dimensions. Built-In Refrigeration 35 subzero.com/specs Dual Installation-Flush Inset Panels H H A H H B H A AH H A AH W BI-36R / BI-36F B W BI-36RG H W BI-30U / BI-36U B H W BI-30UG / BI-36UG BI-36R, BI-36RG and BI...
Sub-Zero Design Guide
Page 36
... to the panel specifications below for more information. Refer to utilize the individual grilles that ship with each unit. Dual wide grilles are for proper installation of 2" (51) wide. The kit includes a 1/4" (6) center trim strip (required for a standard 84" (2134) finished height. Grille panel dimensions ...211) 815/16" (227) H 91/4" (235) 85/16" (211) 815/16" (227) H 91/4" (235) 85/16" (211) 815/16" (227) This dual installation kit is not required if a custom filler strip is available for all built-in models and design applications. Built-In Refrigeration 36 Dual...
... to the panel specifications below for more information. Refer to utilize the individual grilles that ship with each unit. Dual wide grilles are for proper installation of 2" (51) wide. The kit includes a 1/4" (6) center trim strip (required for a standard 84" (2134) finished height. Grille panel dimensions ...211) 815/16" (227) H 91/4" (235) 85/16" (211) 815/16" (227) H 91/4" (235) 85/16" (211) 815/16" (227) This dual installation kit is not required if a custom filler strip is available for all built-in models and design applications. Built-In Refrigeration 36 Dual...
Sub-Zero Design Guide
Page 37
Built-In Refrigeration 37 subzero.com/specs Accessories These optional accessories are available through your authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. • Grilles for an 83" (2108) or 88" (...lengths and the stud spacing of Wolf ovens and ranges. • Full-length standard and extended framed handles. • Stainless steel kickplate. • Dual installation kit with or without dual wide grille. • Retrofit kits for use with 600 series panels. • Partial framed kit for dispenser models. •...
Built-In Refrigeration 37 subzero.com/specs Accessories These optional accessories are available through your authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. • Grilles for an 83" (2108) or 88" (...lengths and the stud spacing of Wolf ovens and ranges. • Full-length standard and extended framed handles. • Stainless steel kickplate. • Dual installation kit with or without dual wide grille. • Retrofit kits for use with 600 series panels. • Partial framed kit for dispenser models. •...
Sub-Zero Design Guide
Page 42
STANDARD TOP VIEW 0" 1" (25) SCALE DOOR OPEN 110° Built-In Refrigeration 42 APPROX PROFILE OF STAINLESS STEEL WRAPPED DOOR AND HANDLE FILLER STRIP 11/4" (32) DOOR CLOSED Dual Installation-Standard FULL-SCALE TEMPLATE Typical framed, overlay or stainless steel dual installation with filler strip at maximum 110° door opening. Depending on panel thickness, a 90° door stop may be required.
STANDARD TOP VIEW 0" 1" (25) SCALE DOOR OPEN 110° Built-In Refrigeration 42 APPROX PROFILE OF STAINLESS STEEL WRAPPED DOOR AND HANDLE FILLER STRIP 11/4" (32) DOOR CLOSED Dual Installation-Standard FULL-SCALE TEMPLATE Typical framed, overlay or stainless steel dual installation with filler strip at maximum 110° door opening. Depending on panel thickness, a 90° door stop may be required.
Sub-Zero Design Guide
Page 43
Depending on panel thickness, a 90° door stop may be required. Built-In Refrigeration 43 subzero.com/specs PROFILE OF 3/4" (19) FLUSH INSET PANEL AND TUBULAR HANDLE FILLER STRIP 11/2" (38) 1/2" (13) DOOR CLOSED Dual Installation-Flush Inset FULL-SCALE TEMPLATE Typical flush inset dual installation with filler strip at maximum 110° door opening. FLUSH INSET TOP VIEW 0" 1" (25) SCALE DOOR OPEN 110°
Depending on panel thickness, a 90° door stop may be required. Built-In Refrigeration 43 subzero.com/specs PROFILE OF 3/4" (19) FLUSH INSET PANEL AND TUBULAR HANDLE FILLER STRIP 11/2" (38) 1/2" (13) DOOR CLOSED Dual Installation-Flush Inset FULL-SCALE TEMPLATE Typical flush inset dual installation with filler strip at maximum 110° door opening. FLUSH INSET TOP VIEW 0" 1" (25) SCALE DOOR OPEN 110°
Sub-Zero Design Guide
Page 45
..." (2134) 648PRO 648PROG KEY FEATURES • Can be used freestanding or installed as exterior. • Handles coordinate with handles of Wolf ranges. • Dual refrigeration system enhanced with or without a glass door and may be either built in the Sub-Zero PRO 48. tors allow independent control of stainless steel. PRO 48 Refrigeration...
..." (2134) 648PRO 648PROG KEY FEATURES • Can be used freestanding or installed as exterior. • Handles coordinate with handles of Wolf ranges. • Dual refrigeration system enhanced with or without a glass door and may be either built in the Sub-Zero PRO 48. tors allow independent control of stainless steel. PRO 48 Refrigeration...