English CONTENTS Page FEATURES... 4 DISPLAY AND BUTTON OPERATION... 5 CROWN WITH DRIVING WHEEL... 7 HOW TO CHARGE AND START THE WATCH 8 HOW TO READ THE DIRECT DRIVE INDICATOR 10 TIME/CALENDAR SETTING...17 IMPROPER FUNCTION...19 AUTOMATIC HAND ALIGNMENT...20 POWER SOURCE (KINETIC E.S.U.)...21 SPECIFICATIONS...22 IFor the care of your watch, see "TO PRESERVE THE QUALITY OF YOUR WATCH" in the attached Worldwide Guarantee and Instruction Booklet.
English CONTENTS Page FEATURES... 4 DISPLAY AND BUTTON OPERATION... 5 CROWN WITH DRIVING WHEEL... 7 HOW TO CHARGE AND START THE WATCH 8 HOW TO READ THE DIRECT DRIVE INDICATOR 10 TIME/CALENDAR SETTING...17 IMPROPER FUNCTION...19 AUTOMATIC HAND ALIGNMENT...20 POWER SOURCE (KINETIC E.S.U.)...21 SPECIFICATIONS...22 IFor the care of your watch, see "TO PRESERVE THE QUALITY OF YOUR WATCH" in the attached Worldwide Guarantee and Instruction Booklet.
Manual
Page 4
... operating time that it displays, charge the watch as necessary so as not to stop operation of the watch until the next time you do not wear the watch for KINETIC ELECTRICITY STORAGE UNIT, which generates electrical energy to power the watch by SEIKO, which is the name of the power ...source employed in motion. ● It is recommended that the watch be worn on your arm, it in the KINETIC ELECTRICITY STORAGE UNIT (KINETIC E.S.U.) The watch is equipped with a direct drive indicator that...
... operating time that it displays, charge the watch as necessary so as not to stop operation of the watch until the next time you do not wear the watch for KINETIC ELECTRICITY STORAGE UNIT, which generates electrical energy to power the watch by SEIKO, which is the name of the power ...source employed in motion. ● It is recommended that the watch be worn on your arm, it in the KINETIC ELECTRICITY STORAGE UNIT (KINETIC E.S.U.) The watch is equipped with a direct drive indicator that...
Manual
Page 8
...marking 0 and the second hand starts moving in 2-second intervals after the crown is not a malfunction. Turn the crown clockwise repeatedly to charge the watch is turned clockwise. Make sure to stop turning the crown to point at scale marking 1 under the 0 position (standby position). 2. It may ...take approximately 5 to the 0 position. Charge the watch has been left untouched for a certain period, the direct drive indicator hand moves to check it. ✽ If the second hand does not move ...
...marking 0 and the second hand starts moving in 2-second intervals after the crown is not a malfunction. Turn the crown clockwise repeatedly to charge the watch is turned clockwise. Make sure to stop turning the crown to point at scale marking 1 under the 0 position (standby position). 2. It may ...take approximately 5 to the 0 position. Charge the watch has been left untouched for a certain period, the direct drive indicator hand moves to check it. ✽ If the second hand does not move ...
Manual
Page 9
... total amount of power generated by the current manual winding for further details. English 3. However, it is not necessary to charge the watch will keep on your wrist. ✽ Refer to "How to read the direct drive indicator" for approximately 4 seconds, and then...Power generation status display Generated power amount display Power reserve display Charge the watch until the indicator hand points at the second marking above "0"(approximately 6 hours of power reserve). ✽ This watch fully, as it is charged automatically while it is worn on operating for approximately...
... total amount of power generated by the current manual winding for further details. English 3. However, it is not necessary to charge the watch will keep on your wrist. ✽ Refer to "How to read the direct drive indicator" for approximately 4 seconds, and then...Power generation status display Generated power amount display Power reserve display Charge the watch until the indicator hand points at the second marking above "0"(approximately 6 hours of power reserve). ✽ This watch fully, as it is charged automatically while it is worn on operating for approximately...
Manual
Page 10
English How to read the direct drive indicator The direct drive indicator can be used to check the following: (1) Power reserve amount (continuous operating time) (2) Real-time power generation status and newly generated amount of power while charging the watch "M+1" position Power reserve/ generated power scale Scale marking 10 Standby position
English How to read the direct drive indicator The direct drive indicator can be used to check the following: (1) Power reserve amount (continuous operating time) (2) Real-time power generation status and newly generated amount of power while charging the watch "M+1" position Power reserve/ generated power scale Scale marking 10 Standby position
Manual
Page 11
... can be displayed. ✽ The power reserve indicator provides an approximate time that the watch stops operating due to a power shortage. ✽ If the crown is turned after the watch is completed, the indicator hand will display the amount of newly generated power for approximately ... charged, the indicator points at the "M+1" position. ■ Real-time power indicator ● While turning the crown to the 0 position, the watch will keep operating in 18 steps (0 - M scale marking). ● The continuous operating time until approximately one month (30 days) can be charged...
... can be displayed. ✽ The power reserve indicator provides an approximate time that the watch stops operating due to a power shortage. ✽ If the crown is turned after the watch is completed, the indicator hand will display the amount of newly generated power for approximately ... charged, the indicator points at the "M+1" position. ■ Real-time power indicator ● While turning the crown to the 0 position, the watch will keep operating in 18 steps (0 - M scale marking). ● The continuous operating time until approximately one month (30 days) can be charged...
Manual
Page 12
... 18 W (Week) 12 M (Month) 6 D 1 W 2 W 3 W 30 D 4H 4H 5H 5H 5H 6 H 20 40 20 40 Min. Scale 12 marking Indication on 0 dial Power reserve amount The watch 0 stops operating. English ■ Scale table of 0 generated power 1 2 3 4 5 6 7 8 9 10 11 12 (12 h) D. (Day) 3 H 6 H 9 H 12 H 15 H 18 H 21 H 1 D 2 D 3 D 4 D 20 40 1 H Min. Amount of power reserve...
... 18 W (Week) 12 M (Month) 6 D 1 W 2 W 3 W 30 D 4H 4H 5H 5H 5H 6 H 20 40 20 40 Min. Scale 12 marking Indication on 0 dial Power reserve amount The watch 0 stops operating. English ■ Scale table of 0 generated power 1 2 3 4 5 6 7 8 9 10 11 12 (12 h) D. (Day) 3 H 6 H 9 H 12 H 15 H 18 H 21 H 1 D 2 D 3 D 4 D 20 40 1 H Min. Amount of power reserve...
Manual
Page 14
...turning the crown, and after the indicator hand stops at the maximum scale value ("M+1" position). If you temporarily stop at the "M+1" position, the watch 1. If the crown is turned repeatedly, the indicator hand will stop turning the crown, the indicator hand goes down to display the accumulated power ...returns to display the total amount of generated power increases. English ■ How to read the direct drive indicator while charging the watch continues to accumulate power reserve, but stops displaying the power generation status. When further continuing to turn the crown.
...turning the crown, and after the indicator hand stops at the maximum scale value ("M+1" position). If you temporarily stop at the "M+1" position, the watch 1. If the crown is turned repeatedly, the indicator hand will stop turning the crown, the indicator hand goes down to display the accumulated power ...returns to display the total amount of generated power increases. English ■ How to read the direct drive indicator while charging the watch continues to accumulate power reserve, but stops displaying the power generation status. When further continuing to turn the crown.
Manual
Page 15
... may take time until it displays the power generation status. ✽ Even if the watch is worn on the wrist after it is charged fully (power reserve of 30 days), and then it is left untouched, the watch will not operate for more than 30 days after it is worn again. ✽...; When you take off the watch and leave it untouched, look at the indicator to check if the watch continues to operate until you wear the watch the next time, and turn the crown to charge the watch as necessary (make sure to store extra power so as not...
... may take time until it displays the power generation status. ✽ Even if the watch is worn on the wrist after it is charged fully (power reserve of 30 days), and then it is left untouched, the watch will not operate for more than 30 days after it is worn again. ✽...; When you take off the watch and leave it untouched, look at the indicator to check if the watch continues to operate until you wear the watch the next time, and turn the crown to charge the watch as necessary (make sure to store extra power so as not...
Manual
Page 16
When temporarily A B crown stopping turning the crown After approximately 4 seconds since starting to power generation status. ✽ The point where the indicator hand starts moving goes up as generated power increases. 16 While turning the B. English Power reserve display Power generation status and generated power display Initial status In-progress After approximately 1 second since stopping turning the crown Power reserve display ✽ The power reserve indicator hand points at a scale marking between 0 and "M+1" according to turn the crown A.
When temporarily A B crown stopping turning the crown After approximately 4 seconds since starting to power generation status. ✽ The point where the indicator hand starts moving goes up as generated power increases. 16 While turning the B. English Power reserve display Power generation status and generated power display Initial status In-progress After approximately 1 second since stopping turning the crown Power reserve display ✽ The power reserve indicator hand points at a scale marking between 0 and "M+1" according to turn the crown A.
Manual
Page 17
English TIME/CALENDAR SETTING TUEMON 1. The watch is set for the A.M. period. Turn the crown to deter- If the calendar changes, the time is set for the A.M. THU FRI signed so that ... position in 24 hours. Turn the hand past the 12 o'clock marker to set . Pull out the crown to the exact minute. 3. mine whether the watch is correctly set the time. ✽ When setting the hour hand, check that the calendar changes once SUSNAT in accordance with a time signal. 17 or...
English TIME/CALENDAR SETTING TUEMON 1. The watch is set for the A.M. period. Turn the crown to deter- If the calendar changes, the time is set for the A.M. THU FRI signed so that ... position in 24 hours. Turn the hand past the 12 o'clock marker to set . Pull out the crown to the exact minute. 3. mine whether the watch is correctly set the time. ✽ When setting the hour hand, check that the calendar changes once SUSNAT in accordance with a time signal. 17 or...
Manual
Page 19
Push the crown back into the normal position. ✽ The indicator hand will point at the 0 position, and the watch stops operating even though it displays the remainder of the power reserve, follow the instructions below to reset the built-in IC 1. ball point pen). 3. Pull out the crown to reset the built-in IC. ■ How to the second click. 2. Press the button for 2 seconds or more using a sharp-pointed tool (e.g. English IMPROPER FUNCTION When the watch resumes its normal operation. 19
Push the crown back into the normal position. ✽ The indicator hand will point at the 0 position, and the watch stops operating even though it displays the remainder of the power reserve, follow the instructions below to reset the built-in IC 1. ball point pen). 3. Pull out the crown to reset the built-in IC. ■ How to the second click. 2. Press the button for 2 seconds or more using a sharp-pointed tool (e.g. English IMPROPER FUNCTION When the watch resumes its normal operation. 19
Manual
Page 20
... even after resetting the built-in rare cases. After automatic hand alignment is performed, the indicator hand will return to charge the watch . Turn the crown to display power reserve amount. While correcting the hand position, the indicator hand moves abnormally, however, this ...is not a malfunction. however, this is not a malfunction. ✽ If the watch was remaining power reserve; English ✽ If the indicator hand points at under the 0 position and vibrates, and then points at the ...
... even after resetting the built-in rare cases. After automatic hand alignment is performed, the indicator hand will return to charge the watch . Turn the crown to display power reserve amount. While correcting the hand position, the indicator hand moves abnormally, however, this ...is not a malfunction. however, this is not a malfunction. ✽ If the watch was remaining power reserve; English ✽ If the indicator hand points at under the 0 position and vibrates, and then points at the ...
Manual
Page 21
English POWER SOURCE (KINETIC E.S.U.) This watch requires no periodic battery replacement as it is powered by the exclusive secondary battery, which can generate heat that can cause bursting or ignition. 21 CAUTION Never install a silver oxide battery for watches. This exclusive secondary battery is completely different from conventional batteries for conventional watches in place of the KINETIC E.S.U. , which is an environmentally friendly, clean energy storage device.
English POWER SOURCE (KINETIC E.S.U.) This watch requires no periodic battery replacement as it is powered by the exclusive secondary battery, which can generate heat that can cause bursting or ignition. 21 CAUTION Never install a silver oxide battery for watches. This exclusive secondary battery is completely different from conventional batteries for conventional watches in place of the KINETIC E.S.U. , which is an environmentally friendly, clean energy storage device.
Manual
Page 22
... 4 Driving system Step motor: 2 pieces 5 Display system Hour, minute, second, date, and day of charge Approximately 1 month (if the watch is fully charged) 8 Additional functions Overcharge prevention function 9 IC (Integrated Circuit C-MOS-IC, 1 piece 10 Generating system Miniature AC generator * ...The specifications are subject to change without prior notice for 5D44). Power reserve display, power generation status display, and generated power amount display 6 KINETIC electricity storage unit Button type, 1 ...
... 4 Driving system Step motor: 2 pieces 5 Display system Hour, minute, second, date, and day of charge Approximately 1 month (if the watch is fully charged) 8 Additional functions Overcharge prevention function 9 IC (Integrated Circuit C-MOS-IC, 1 piece 10 Generating system Miniature AC generator * ...The specifications are subject to change without prior notice for 5D44). Power reserve display, power generation status display, and generated power amount display 6 KINETIC electricity storage unit Button type, 1 ...