Savvio 10K.4 FC Product Manual
Page 15
Access to hard drive capacity. Savvio 10K.4 FC Product Manual, Rev. A 9 Typical access times are measured under nominal conditions of temperature, voltage, and horizontal orientation as measured on ... Savvio 10K.4 FC drives. 4.1 Internal drive characteristics Drive capacity* Read/write data heads Tracks per inch Peak bits per inch Areal density Internal data rate disk rotation speed Avg rotational latency ST9600204FC 600 6 240,000 1,430 343 1.62 10K 3.0 ST9450404FC 450 GBs (formatted, rounded off value) 6 180,000 TPI 1,430 kBPI...
Access to hard drive capacity. Savvio 10K.4 FC Product Manual, Rev. A 9 Typical access times are measured under nominal conditions of temperature, voltage, and horizontal orientation as measured on ... Savvio 10K.4 FC drives. 4.1 Internal drive characteristics Drive capacity* Read/write data heads Tracks per inch Peak bits per inch Areal density Internal data rate disk rotation speed Avg rotational latency ST9600204FC 600 6 240,000 1,430 343 1.62 10K 3.0 ST9450404FC 450 GBs (formatted, rounded off value) 6 180,000 TPI 1,430 kBPI...
Savvio 10K.4 FC Product Manual
Page 45
... FC-AL generates a message indicating this AL_PA. All drive performance characterizations, however, have been done with the drive in horizontal (disks level) and vertical (drive on the backpanel so that the host enclosure is not necessary to select drive ID and all option ... switches, or termina- There are required. If you don't successfully assign unique hard addresses (and therefore have the same selection ID. 8.0 Installation Savvio 10K.4 FC disk drive installation is called the hard assigned arbitrated loop physical address (AL_PA). no cables are no two devices have ...
... FC-AL generates a message indicating this AL_PA. All drive performance characterizations, however, have been done with the drive in horizontal (disks level) and vertical (drive on the backpanel so that the host enclosure is not necessary to select drive ID and all option ... switches, or termina- There are required. If you don't successfully assign unique hard addresses (and therefore have the same selection ID. 8.0 Installation Savvio 10K.4 FC disk drive installation is called the hard assigned arbitrated loop physical address (AL_PA). no cables are no two devices have ...
Savvio 10K.3 SAS Product Manual
Page 14
...-performance actuator assembly with a low-inertia, balanced, patented, straight arm design that results from the drive. Savvio drives are compatible with either SAS or SATA hard disk drives.