Savvio 10K.1 FC Product Manual
Page 2
...GB, equals one of their respective owners. Quantitative usage examples for various applications are the property of its affiliated companies in the United States and/or other countries. D, August May 2007 Seagate, Seagate Technology and the Wave logo are either trademarks or registered trademarks of Seagate...All rights reserved. Savvio, SeaTools and SeaTDD are registered trademarks of Seagate Technology LLC or one billion bytes when referring to change, without notice, product offerings or specifications. Seagate reserves the right to hard drive capacity. Publication number...
...GB, equals one of their respective owners. Quantitative usage examples for various applications are the property of its affiliated companies in the United States and/or other countries. D, August May 2007 Seagate, Seagate Technology and the Wave logo are either trademarks or registered trademarks of Seagate...All rights reserved. Savvio, SeaTools and SeaTDD are registered trademarks of Seagate Technology LLC or one billion bytes when referring to change, without notice, product offerings or specifications. Seagate reserves the right to hard drive capacity. Publication number...
Savvio 10K.1 FC Product Manual
Page 47
.... The air-flow patterns are acceptable as long as shown in Section 6.4.1. Savvio FC Product Manual, Rev. D 41 If you want to select a different logical block size. 8.1 Drive orientation The drive may be mounted in any value other forced airflow patterns are created by fans... or drawing air as the temperature measurement guidelines of 0, the system issues a unique soft-assigned physical address automatically. The drive is called the hard assigned arbitrated loop physical address (AL_PA). In some cases, forced airflow may be required to keep temperatures at or below ...
.... The air-flow patterns are acceptable as long as shown in Section 6.4.1. Savvio FC Product Manual, Rev. D 41 If you want to select a different logical block size. 8.1 Drive orientation The drive may be mounted in any value other forced airflow patterns are created by fans... or drawing air as the temperature measurement guidelines of 0, the system issues a unique soft-assigned physical address automatically. The drive is called the hard assigned arbitrated loop physical address (AL_PA). In some cases, forced airflow may be required to keep temperatures at or below ...
Savvio 10K.1 FC Product Manual
Page 55
... No Loop Position Yes Loop Position Report Yes 9.2 Dual port support Savvio drives have the same loop address. • If both ports. Subject to buffer availability, the Savvio drives support: • Concurrent port transfers-The drive supports receiving transfers on both ports at the same time when the ...will attempt taking a soft address to open another device. Port A and Port B may be connected in the same loop and hard addressing is used , the drive interface address is used , at least one port will seek the same loop address. D 49 Table 14: FC-AL options ...
... No Loop Position Yes Loop Position Report Yes 9.2 Dual port support Savvio drives have the same loop address. • If both ports. Subject to buffer availability, the Savvio drives support: • Concurrent port transfers-The drive supports receiving transfers on both ports at the same time when the ...will attempt taking a soft address to open another device. Port A and Port B may be connected in the same loop and hard addressing is used , the drive interface address is used , at least one port will seek the same loop address. D 49 Table 14: FC-AL options ...
Savvio 10K.1 FC Product Manual
Page 61
...downloading a complete set up new current and saved values, where the values are hard-coded in the drive firmware stored in the saved values list that are stored on the drive's PCB. When power is "ready." D 55 Savvio FC Product Manual, Rev. Refer to the values below for the values of ...possible to change the current values (or the saved values) with a Mode Select command before the drive achieves operating speed and is applied to set of you particular model: ST936701FC 53 54 39 33 36 37 30 31 46 43 9.3.2 Mode Sense data The Mode Sense command provides a way for ...
...downloading a complete set up new current and saved values, where the values are hard-coded in the drive firmware stored in the saved values list that are stored on the drive's PCB. When power is "ready." D 55 Savvio FC Product Manual, Rev. Refer to the values below for the values of ...possible to change the current values (or the saved values) with a Mode Select command before the drive achieves operating speed and is applied to set of you particular model: ST936701FC 53 54 39 33 36 37 30 31 46 43 9.3.2 Mode Sense data The Mode Sense command provides a way for ...
Savvio 10K.1 FC Product Manual
Page 62
...flash E-PROM. A one (1) indicates the value can be changed by downloading new firmware into the saved values storage location on reset, hard reset, or Bus Device Reset message. 4. These are all of the bits in bytes 04 and 05 none of these bits are changeable...following tables list the values of some drives. D The following tables may not exactly match those fields are hex numbers representing the changeable values for SCSI implementation (see the Fibre Channel Interface Manual). A zero (0) indicates the value is changeable. 56 Savvio FC Product Manual, Rev. For ...
...flash E-PROM. A one (1) indicates the value can be changed by downloading new firmware into the saved values storage location on reset, hard reset, or Bus Device Reset message. 4. These are all of the bits in bytes 04 and 05 none of these bits are changeable...following tables list the values of some drives. D The following tables may not exactly match those fields are hex numbers representing the changeable values for SCSI implementation (see the Fibre Channel Interface Manual). A zero (0) indicates the value is changeable. 56 Savvio FC Product Manual, Rev. For ...
Savvio 10K.1 FC Product Manual
Page 79
...59 intermediate/good status 59 Intermix 45, 48 internal data rate 11 internal defects/errors 39 internal drive characteristics 11 J Jumper settings page command 50 jumpers 41 L latency average rotational 11, 12 LBdata...Synchronized (locked) spindle operation 59 Zero latency read /write data 11 host equipment 42 hot plugging the drive 18 humidity 32 humidity limits 32 I IC 45 ID and configuration options 7 Implemented operating def. ... gradient 32 ground shift noise 63 grounding 42 H hard assigned arbitrated loop physical address (AL_PA) 41 HDA 42 heads read 59 miscellaneous status support ACA ...
...59 intermediate/good status 59 Intermix 45, 48 internal data rate 11 internal defects/errors 39 internal drive characteristics 11 J Jumper settings page command 50 jumpers 41 L latency average rotational 11, 12 LBdata...Synchronized (locked) spindle operation 59 Zero latency read /write data 11 host equipment 42 hot plugging the drive 18 humidity 32 humidity limits 32 I IC 45 ID and configuration options 7 Implemented operating def. ... gradient 32 ground shift noise 63 grounding 42 H hard assigned arbitrated loop physical address (AL_PA) 41 HDA 42 heads read 59 miscellaneous status support ACA ...