Savvio 10K.1 SAS Product Manual
Page 4
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev. D
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev. D
Savvio 10K.1 SAS Product Manual
Page 7
Figure 1. The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. Savvio family disc drive Savvio SAS Product Manual, Rev. D 1 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives. Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives.
Figure 1. The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. Savvio family disc drive Savvio SAS Product Manual, Rev. D 1 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives. Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives.
Savvio 10K.1 SAS Product Manual
Page 13
... a variety of the media to leverage your warranty. The head and disc assembly (HDA) is removed from the servo data embedded on each surface to support the Serial Attached SCSI Protocol as described in the sealed enclosure (heads, media, actuator, etc.) as intelligent peripherals and provide level 2 conformance (highest level) with...
... a variety of the media to leverage your warranty. The head and disc assembly (HDA) is removed from the servo data embedded on each surface to support the Serial Attached SCSI Protocol as described in the sealed enclosure (heads, media, actuator, etc.) as intelligent peripherals and provide level 2 conformance (highest level) with...
Savvio 10K.1 SAS Product Manual
Page 14
... standard features: • 1.5 / 3 Gbit Serial Attached SCSI (SAS) interface • Integrated dual port SAS controller supporting the SCSI protocol • Support for improved durability and environmental protection. 3.3 Performance • Programmable multi-segmentable cache buffer • 300 Mbytes/sec maximum...SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 64 - deep task set (queue) • Supports up to 32 initiators • Jumperless configuration. • User-selectable logical block size (512 to the drive • Zone ...
... standard features: • 1.5 / 3 Gbit Serial Attached SCSI (SAS) interface • Integrated dual port SAS controller supporting the SCSI protocol • Support for improved durability and environmental protection. 3.3 Performance • Programmable multi-segmentable cache buffer • 300 Mbytes/sec maximum...SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 64 - deep task set (queue) • Supports up to 32 initiators • Jumperless configuration. • User-selectable logical block size (512 to the drive • Zone ...
Savvio 10K.1 SAS Product Manual
Page 20
.... Each cache segment is actually a self-contained circular buffer whose length is set up for the drive. 14 Savvio SAS Product Manual, Rev. The drive supports operation of any remaining requested logical block addresses from the disc and puts them into the cache, but before the data has been written to...
.... Each cache segment is actually a self-contained circular buffer whose length is set up for the drive. 14 Savvio SAS Product Manual, Rev. The drive supports operation of any remaining requested logical block addresses from the disc and puts them into the cache, but before the data has been written to...
Savvio 10K.1 SAS Product Manual
Page 45
...reads) or AWRE bit (for writes) is one, the RC bit is zero, and the recovery time limit for a single LBA. The error recovery scheme supported by the drive provides a way to control the total error recovery time for the entire command in the "G" list (defects growth list). Each level may... be limited using the Read Retry Count or Write Retry Count bytes in the Error Recovery mode page. Tools for use of the SCSI commands supported by the host (initiator). The times given do so, performs error recovery procedures to attempt to as the "P' list and also as delivered, complies ...
...reads) or AWRE bit (for writes) is one, the RC bit is zero, and the recovery time limit for a single LBA. The error recovery scheme supported by the drive provides a way to control the total error recovery time for the entire command in the "G" list (defects growth list). Each level may... be limited using the Read Retry Count or Write Retry Count bytes in the Error Recovery mode page. Tools for use of the SCSI commands supported by the host (initiator). The times given do so, performs error recovery procedures to attempt to as the "P' list and also as delivered, complies ...
Savvio 10K.1 SAS Product Manual
Page 51
...08 Invalid logical unit 09 Savvio SAS Product Manual, Rev. D 45 Table 15: SAS task management functions supported Task name Abort Task Clear ACA Supported Yes Yes Clear task set Yes Abort task set Yes Logical Unit Reset Yes Query Task Yes 9.1.2 task ...management responses Table 16 lists the SAS response codes returned for task management functions supported. 9.0 Interface requirements This section partially describes the interface requirements as implemented on Savvio drives. Additional information is provided in the SAS...
...08 Invalid logical unit 09 Savvio SAS Product Manual, Rev. D 45 Table 15: SAS task management functions supported Task name Abort Task Clear ACA Supported Yes Yes Clear task set Yes Abort task set Yes Logical Unit Reset Yes Query Task Yes 9.1.2 task ...management responses Table 16 lists the SAS response codes returned for task management functions supported. 9.0 Interface requirements This section partially describes the interface requirements as implemented on Savvio drives. Additional information is provided in the SAS...
Savvio 10K.1 SAS Product Manual
Page 52
... speed negotiation looses sync before the second port completes speed negotiation, both ports. Subject to buffer availability, the Savvio drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on condition of allowing either link rate (1.5 or 3.0 Gbits/sec). D When the second... participates in the same or different SCSI domains. These ports may be connected in speed negotiation, it indicates the only supported speed is the speed selected by both ports revert back to successfully complete speed negotiation sets the link rate...
... speed negotiation looses sync before the second port completes speed negotiation, both ports. Subject to buffer availability, the Savvio drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on condition of allowing either link rate (1.5 or 3.0 Gbits/sec). D When the second... participates in the same or different SCSI domains. These ports may be connected in speed negotiation, it indicates the only supported speed is the speed selected by both ports revert back to successfully complete speed negotiation sets the link rate...
Savvio 10K.1 SAS Product Manual
Page 53
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
Savvio 10K.1 SAS Product Manual
Page 54
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
Savvio 10K.1 SAS Product Manual
Page 55
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
Savvio 10K.1 SAS Product Manual
Page 56
...can format to 528 bytes. [2] Warning. Command is available on special request. 50 Savvio SAS Product Manual, Rev. A = Support is supported. Command is not supported. Table 17: Commands supported by Savvio SAS family drive (continued) Command name Verify (12) Verify (16) Verify (32) Write (6) Write (10) DPO...(10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Firmware Download option (modes 5, 7, Ah and Bh supported) [3] Write Long (10) Write Long (16) Write Same (10) PBdata LBdata Write Same (16) Write Same (32) XDRead ...
...can format to 528 bytes. [2] Warning. Command is available on special request. 50 Savvio SAS Product Manual, Rev. A = Support is supported. Command is not supported. Table 17: Commands supported by Savvio SAS family drive (continued) Command name Verify (12) Verify (16) Verify (32) Write (6) Write (10) DPO...(10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Firmware Download option (modes 5, 7, Ah and Bh supported) [3] Write Long (10) Write Long (16) Write Same (10) PBdata LBdata Write Same (16) Write Same (32) XDRead ...
Savvio 10K.1 SAS Product Manual
Page 61
... Synchronized (locked) spindle operation Segmented caching Zero latency read Queue tagging (up to save RPL and rotational offset bytes Table 22: Miscellaneous status Supported Y Y Y Y Y Y Y Y N N Status Good Check condition Condition met/good Busy Intermediate/good Intermediate/condition met/good Reservation ... active, faulted initiator Savvio SAS Product Manual, Rev. D 55 A "Y" in Mode Select command needed to 64 queue tags supported) Deferred error handling Parameter rounding (controlled by Round bit in Mode Select page 0) Reporting actual retry count in Extended Sense bytes...
... Synchronized (locked) spindle operation Segmented caching Zero latency read Queue tagging (up to save RPL and rotational offset bytes Table 22: Miscellaneous status Supported Y Y Y Y Y Y Y Y N N Status Good Check condition Condition met/good Busy Intermediate/good Intermediate/condition met/good Reservation ... active, faulted initiator Savvio SAS Product Manual, Rev. D 55 A "Y" in Mode Select command needed to 64 queue tags supported) Deferred error handling Parameter rounding (controlled by Round bit in Mode Select page 0) Reporting actual retry count in Extended Sense bytes...
Savvio 10K.1 SAS Product Manual
Page 66
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC -
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC -
Savvio 10K.1 SAS Product Manual
Page 71
... is unpowered or transmitting D.C. A.C. The same stable trigger, coherent to 80 % of an OOB signal). voltage measured at signal voltage levels corresponding to the lowest supported transfer rate. f The maximum difference in this table shall be used for both the Tx+ and Tx- A.C. D 65 offset) component between the V+ and V- Table 27...
... is unpowered or transmitting D.C. A.C. The same stable trigger, coherent to 80 % of an OOB signal). voltage measured at signal voltage levels corresponding to the lowest supported transfer rate. f The maximum difference in this table shall be used for both the Tx+ and Tx- A.C. D 65 offset) component between the V+ and V- Table 27...
Savvio 10K.1 SAS Product Manual
Page 79
...center in the world. You can help you online at support.seagate.com or through a single, password-protected Web interface-anytime, anywhere in the world. Technical Support Seagate technical support is available 24 hours daily by email for customized communications...available. Savvio SAS Product Manual, Rev. D 73 spp.seagate.com spp.seagate.com supports Seagate resellers with a technical support specialist during normal business hours for your questions. Seagate Service Centers Presales Support Our Presales Support staff can send questions or comments 24 hours daily and...
...center in the world. You can help you online at support.seagate.com or through a single, password-protected Web interface-anytime, anywhere in the world. Technical Support Seagate technical support is available 24 hours daily by email for customized communications...available. Savvio SAS Product Manual, Rev. D 73 spp.seagate.com spp.seagate.com supports Seagate resellers with a technical support specialist during normal business hours for your questions. Seagate Service Centers Presales Support Our Presales Support staff can send questions or comments 24 hours daily and...
Savvio 10K.1 SAS Product Manual
Page 80
... nearest you. Contact your serial number and model or part number available. Data Recovery Services Seagate offers data recovery services for the return of telephone numbers to technical support, presales and warranty service in Europe, the Middle East and Africa, go to the "Contact... Us" page on www.seagate.com. Global Customer Support Presales, Technical, and Warranty Support Call Center Toll-free USA, Canada, and Mexico 1-800-SEAGATE Data Recovery Services Call Center USA, Canada, and Mexico Toll-free 1-800-475-01435...
... nearest you. Contact your serial number and model or part number available. Data Recovery Services Seagate offers data recovery services for the return of telephone numbers to technical support, presales and warranty service in Europe, the Middle East and Africa, go to the "Contact... Us" page on www.seagate.com. Global Customer Support Presales, Technical, and Warranty Support Call Center Toll-free USA, Canada, and Mexico 1-800-SEAGATE Data Recovery Services Call Center USA, Canada, and Mexico Toll-free 1-800-475-01435...
Savvio 10K.1 SAS Product Manual
Page 81
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
Savvio 10K.1 SAS Product Manual
Page 82
...43 head and disc assembly (HDA) 7 head and disc assembly. See MTBF media description 8 minimum sector interleave 12 miscellaneous feature support Adaptive caching 55 Asynchronous event notification 55 Automatic contingent allegiance 55 Deferred error handling 55 Parameter rounding 55 Queue tagging 55 Reporting actual ...equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 ...
...43 head and disc assembly (HDA) 7 head and disc assembly. See MTBF media description 8 minimum sector interleave 12 miscellaneous feature support Adaptive caching 55 Asynchronous event notification 55 Automatic contingent allegiance 55 Deferred error handling 55 Parameter rounding 55 Queue tagging 55 Reporting actual ...equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 ...
Savvio 10K.1 SAS Product Manual
Page 83
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...