Savvio 10K.4 FC Product Manual
Page 9
... for the disk drives documented in place to confirm compliance with our chemical substance restrictions, and our suppliers document their product. Seagate also has internal systems in this Seagate model complies ...with . Our supplier contracts require compliance with the directives/standards for typical applications. These systems include standard operating procedures that ensure that restricted substances are not utilized in these parts and materials. A number of Australia's Spectrum Management...
... for the disk drives documented in place to confirm compliance with our chemical substance restrictions, and our suppliers document their product. Seagate also has internal systems in this Seagate model complies ...with . Our supplier contracts require compliance with the directives/standards for typical applications. These systems include standard operating procedures that ensure that restricted substances are not utilized in these parts and materials. A number of Australia's Spectrum Management...
Savvio 10K.4 FC Product Manual
Page 26
... the method by which the drive entered the PowerChoice state. Motor stopped (disks not spinning PowerChoice can be invoked using the load/unload architecture provide programmable power management to tailor systems for performance and greater energy efficiency. If both the Power...6.0 Physical/electrical specifications This section provides information relating to the physical and electrical characteristics of the drive. 6.1 PowerChoiceTM power management Drives using one of these two methods: • Power Condition mode page method-Enable and initialize the idle condition timers ...
... the method by which the drive entered the PowerChoice state. Motor stopped (disks not spinning PowerChoice can be invoked using the load/unload architecture provide programmable power management to tailor systems for performance and greater energy efficiency. If both the Power...6.0 Physical/electrical specifications This section provides information relating to the physical and electrical characteristics of the drive. 6.1 PowerChoiceTM power management Drives using one of these two methods: • Power Condition mode page method-Enable and initialize the idle condition timers ...
Savvio 10K.4 FC Product Manual
Page 43
...37 During Pre-Scan write verify commands, write performance may be performed after 500ms of idle time. Status reporting plays a role in systems error management and its use in that the data was properly written to system performance. In RAID arrays, BMS allows hot spare drives to certify that ...after Pre-Scan is described in sections where the various commands are only done during idle periods, BMS causes a negligible impact to the disk. 7.3 FC-AL system errors Information on the reporting of operational errors or faults across the entire pack of the media while the drive...
...37 During Pre-Scan write verify commands, write performance may be performed after 500ms of idle time. Status reporting plays a role in systems error management and its use in that the data was properly written to system performance. In RAID arrays, BMS allows hot spare drives to certify that ...after Pre-Scan is described in sections where the various commands are only done during idle periods, BMS causes a negligible impact to the disk. 7.3 FC-AL system errors Information on the reporting of operational errors or faults across the entire pack of the media while the drive...
Savvio 10K.4 FC Product Manual
Page 78
... command 49 device selection IDs 39 devices 39 dimensions 34 Disable page out command 50 Disconnect/reconnect control (page 02h) command 49 disk rotation speed 9 Download microcode and save modes (5) 51 Download microcode mode (4) 51 Download microcode with offsets and save mode (7) ...physical interface 58 SCA device connector, illustrated 59 selective reset 57 FCC rules and regulations 2 FCP for SCSI, document 4 response codes 43 task management functions 43 FC-PH document 4 features 6 interface 42 Fibre Channel documents 4 Fibre Channel Interface Control page (19h) 50 Fibre Channel Interface ...
... command 49 device selection IDs 39 devices 39 dimensions 34 Disable page out command 50 Disconnect/reconnect control (page 02h) command 49 disk rotation speed 9 Download microcode and save modes (5) 51 Download microcode mode (4) 51 Download microcode with offsets and save mode (7) ...physical interface 58 SCA device connector, illustrated 59 selective reset 57 FCC rules and regulations 2 FCP for SCSI, document 4 response codes 43 task management functions 43 FC-PH document 4 features 6 interface 42 Fibre Channel documents 4 Fibre Channel Interface Control page (19h) 50 Fibre Channel Interface ...
Savvio 10K.4 FC Product Manual
Page 81
...A 75 Power Condition mode page 20 Power control page (1Ah) command 50 power distribution 2 power failure warning 65 power management 20 PowerChoice 20 PowerChoice reports 21 Prefetch command 51 prefetch/multi-segmented cache control 10 preventive maintenance 13 private loop FC-AL ... sense command 49 reservation conflict status 57 Reserve command 49 Reserved (10) command 52 resonance 30 return information 19 Rezero unit command 49 Rigid disk drive geometry page command 49 RoHS 33 rotation speed 9 running disparity 14 S safety 2 SCSI interface commands supported 49 Search data equal command ...
...A 75 Power Condition mode page 20 Power control page (1Ah) command 50 power distribution 2 power failure warning 65 power management 20 PowerChoice 20 PowerChoice reports 21 Prefetch command 51 prefetch/multi-segmented cache control 10 preventive maintenance 13 private loop FC-AL ... sense command 49 reservation conflict status 57 Reserve command 49 Reserved (10) command 52 resonance 30 return information 19 Rezero unit command 49 Rigid disk drive geometry page command 49 RoHS 33 rotation speed 9 running disparity 14 S safety 2 SCSI interface commands supported 49 Search data equal command ...
Savvio 10K.4 SAS Product Manual
Page 28
... Physical/electrical specifications This section provides information relating to the physical and electrical characteristics of the drive. 6.1 PowerChoiceTM power management Drives using one of these two methods: • Power Condition mode page method-Enable and initialize the idle condition ...method-Use the START STOP UNIT command (OPERATION CODE 1Bh). C Motor stopped (disks not spinning) PowerChoiceTM can be invoked using the load/unload architecture provide programmable power management to any supported PowerChoice mode. When the drive receives a command, all outstanding ...
... Physical/electrical specifications This section provides information relating to the physical and electrical characteristics of the drive. 6.1 PowerChoiceTM power management Drives using one of these two methods: • Power Condition mode page method-Enable and initialize the idle condition ...method-Use the START STOP UNIT command (OPERATION CODE 1Bh). C Motor stopped (disks not spinning) PowerChoiceTM can be invoked using the load/unload architecture provide programmable power management to any supported PowerChoice mode. When the drive receives a command, all outstanding ...
Savvio 10K.3 SAS Product Manual
Page 74
H dimensions 35 disk rotation speed 10 drive 34 drive characteristics 10 drive failure 15 Drive Locking 39 drive mounting 35, 47 drive select 62 ...susceptibility 34 EMI requirements 3 encryption engine 38 encryption key 39 environment 46 environmental limits 30 requirements 14 environmental control 34 EraseMaster 39 error management 41 rates 14 errors 41 European Union Restriction of Hazardous Substanc- See HDA heads read/write data 10 heat removal 46 heat source 46...48 G Global Data Band 39 Good status 58 gradient 31 ground shift noise 63 grounding 47 H HDA 46, 47 head and disk assembly.
H dimensions 35 disk rotation speed 10 drive 34 drive characteristics 10 drive failure 15 Drive Locking 39 drive mounting 35, 47 drive select 62 ...susceptibility 34 EMI requirements 3 encryption engine 38 encryption key 39 environment 46 environmental limits 30 requirements 14 environmental control 34 EraseMaster 39 error management 41 rates 14 errors 41 European Union Restriction of Hazardous Substanc- See HDA heads read/write data 10 heat removal 46 heat source 46...48 G Global Data Band 39 Good status 58 gradient 31 ground shift noise 63 grounding 47 H HDA 46, 47 head and disk assembly.