Savvio 15K.1 FC User Guide
Page 4
... Channel Process Login Accept 47 9.1.8 Fibre Channel fabric login 47 9.1.9 Fibre Channel fabric accept login 48 9.1.10 Fibre Channel Arbitrated Loop options 49 9.2 Dual port support 49 9.3 SCSI commands supported 50 9.3.1 Inquiry data 55 9.4 Miscellaneous operating features and conditions 56 ii Savvio 15K.1 FC Product Manual, Rev.
... Channel Process Login Accept 47 9.1.8 Fibre Channel fabric login 47 9.1.9 Fibre Channel fabric accept login 48 9.1.10 Fibre Channel Arbitrated Loop options 49 9.2 Dual port support 49 9.3 SCSI commands supported 50 9.3.1 Inquiry data 55 9.4 Miscellaneous operating features and conditions 56 ii Savvio 15K.1 FC Product Manual, Rev.
Savvio 15K.1 FC User Guide
Page 5
... SEL_0 ID lines 62 9.5.12 Device control codes 64 9.6 Signal characteristics 64 9.6.1 TTL input characteristics 64 9.6.2 Differential PECL output 65 9.6.3 Differential PECL input 65 10.0 Seagate Technology support services 67 Savvio 15K.1 FC Product Manual, Rev.
... SEL_0 ID lines 62 9.5.12 Device control codes 64 9.6 Signal characteristics 64 9.6.1 TTL input characteristics 64 9.6.2 Differential PECL output 65 9.6.3 Differential PECL input 65 10.0 Seagate Technology support services 67 Savvio 15K.1 FC Product Manual, Rev.
Savvio 15K.1 FC User Guide
Page 9
Figure 1. Savvio drives support the Fibre Channel Arbitrated Loop and SCSI Fibre Channel Protocol specifications to the extent described in this and other Seagate Fibre Channel drives. Savvio 15K.1 family disc drive Savvio 15K.1 FC Product Manual, Rev. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® 15K.1 FC (Fibre Channel) disc drives. B 1 The Fibre Channel Interface Manual (part number 77767496) describes the general Fibre Channel Arbitrated Loop characteristics of this manual.
Figure 1. Savvio drives support the Fibre Channel Arbitrated Loop and SCSI Fibre Channel Protocol specifications to the extent described in this and other Seagate Fibre Channel drives. Savvio 15K.1 family disc drive Savvio 15K.1 FC Product Manual, Rev. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® 15K.1 FC (Fibre Channel) disc drives. B 1 The Fibre Channel Interface Manual (part number 77767496) describes the general Fibre Channel Arbitrated Loop characteristics of this manual.
Savvio 15K.1 FC User Guide
Page 15
... removed from movement during shipping and handling. The drives also use a dedicated landing zone at up to the drive. Savvio drives support the Fibre Channel Arbitrated Loop (FC-AL) and SCSI Fibre Channel Protocol as described in the ANSI specifications, this document, the ...HDA and do not attempt to the heads and discs that provides excellent performance with the ANSI SCSI-1 standard. Savvio drives also support 4-Gbit Fibre Channel which describes the general interface characteristics of this requires special facilities. An automatic shipping lock prevents potential damage to...
... removed from movement during shipping and handling. The drives also use a dedicated landing zone at up to the drive. Savvio drives support the Fibre Channel Arbitrated Loop (FC-AL) and SCSI Fibre Channel Protocol as described in the ANSI specifications, this document, the ...HDA and do not attempt to the heads and discs that provides excellent performance with the ANSI SCSI-1 standard. Savvio drives also support 4-Gbit Fibre Channel which describes the general interface characteristics of this requires special facilities. An automatic shipping lock prevents potential damage to...
Savvio 15K.1 FC User Guide
Page 16
...the block size must be divisable by 8 • Integrated dual port FC-AL controller • Concurrent dual port transfers • Support for FC arbitrated loop, private and public attachment • Differential copper FC drivers and receivers • Downloadable firmware using the FC-AL ...interface • Supports SCSI enclosure services via interface connector • 128-deep task set (queue) • Supports up to the drive • Zone bit recording (ZBR) • Vertical, horizontal, or top...
...the block size must be divisable by 8 • Integrated dual port FC-AL controller • Concurrent dual port transfers • Support for FC arbitrated loop, private and public attachment • Differential copper FC drivers and receivers • Downloadable firmware using the FC-AL ...interface • Supports SCSI enclosure services via interface connector • 128-deep task set (queue) • Supports up to the drive • Zone bit recording (ZBR) • Vertical, horizontal, or top...
Savvio 15K.1 FC User Guide
Page 17
...The current guaranteed operating points for enhanced system performance. • 400 Mbytes/sec maximum instantaneous data transfers per block. Seagate drives also may modify the data block size before issuing a format command and obtain different formatted capacities than those listed...performance 3.4 Reliability • Annualized Failure Rate (AFR) of 0.55% • Mean Time Between Failures (MTBF) of queue • Supports start and stop commands (spindle stops spinning) • Adaptive seek velocity; We recommend customers use this product are formatted to 1.3 percent ...
...The current guaranteed operating points for enhanced system performance. • 400 Mbytes/sec maximum instantaneous data transfers per block. Seagate drives also may modify the data block size before issuing a format command and obtain different formatted capacities than those listed...performance 3.4 Reliability • Annualized Failure Rate (AFR) of 0.55% • Mean Time Between Failures (MTBF) of queue • Supports start and stop commands (spindle stops spinning) • Adaptive seek velocity; We recommend customers use this product are formatted to 1.3 percent ...
Savvio 15K.1 FC User Guide
Page 45
... defect and error management involves drive internal defect/error management and SAS system error considerations (errors in video applications. In addition, Seagate provides the following technologies used depend on the medium and the location listed in the Error Recovery Parameters mode page. The "P" ... is , reassigned to increase data integrity, perform drive self-maintenance, and validate proper drive operation. Locations of the SCSI commands supported by the drive are identified, tagged as the ETF defect list). Details of defects found and reallocated during drive operation, the ...
... defect and error management involves drive internal defect/error management and SAS system error considerations (errors in video applications. In addition, Seagate provides the following technologies used depend on the medium and the location listed in the Error Recovery Parameters mode page. The "P" ... is , reassigned to increase data integrity, perform drive self-maintenance, and validate proper drive operation. Locations of the SCSI commands supported by the drive are identified, tagged as the ETF defect list). Details of defects found and reallocated during drive operation, the ...
Savvio 15K.1 FC User Guide
Page 51
... number 100293070). 9.1 FC-AL features This section lists the Fibre Channel-specific features supported by Savvio drives. 9.1.1 Fibre Channel link service frames Table 5 lists the link services supported by Savvio drives. B 43 9.0 Interface requirements This section partially describes the interface ...requirements as implemented on Savvio drives. Table 5: Link services supported Type of frame Link service Basic link service frames Abort Sequence (ABTS) Basic link service reply frames Basic_Accept (BA_ACC...
... number 100293070). 9.1 FC-AL features This section lists the Fibre Channel-specific features supported by Savvio drives. 9.1.1 Fibre Channel link service frames Table 5 lists the link services supported by Savvio drives. B 43 9.0 Interface requirements This section partially describes the interface ...requirements as implemented on Savvio drives. Table 5: Link services supported Type of frame Link service Basic link service frames Abort Sequence (ABTS) Basic link service reply frames Basic_Accept (BA_ACC...
Savvio 15K.1 FC User Guide
Page 52
... task set Yes Abort task set Yes 9.1.3 Fibre Channel task management responses Table 7 lists the FC SCSI FCP response codes returned for task management functions supported. B 9.1.2 Fibre Channel task management functions Table 6 lists the Fibre Channel SCSI Fibre Channel Protocol (FC SCSI FCP) task management functions...
... task set Yes Abort task set Yes 9.1.3 Fibre Channel task management responses Table 7 lists the FC SCSI FCP response codes returned for task management functions supported. B 9.1.2 Fibre Channel task management functions Table 6 lists the Fibre Channel SCSI Fibre Channel Protocol (FC SCSI FCP) task management functions...
Savvio 15K.1 FC User Guide
Page 53
... XX XX XX XX XX Vendor XX XX XX XX Version X Indicates a four-bit (hex) field is not checked. Port Login Accept will return a 0-not supported. Only the receive buffer field size in the common and Class 3 parameters is checked for the range 128 < FS < 2,112 and a multiple of four bytes...
... XX XX XX XX XX Vendor XX XX XX XX Version X Indicates a four-bit (hex) field is not checked. Port Login Accept will return a 0-not supported. Only the receive buffer field size in the common and Class 3 parameters is checked for the range 128 < FS < 2,112 and a multiple of four bytes...
Savvio 15K.1 FC User Guide
Page 57
... ports are connected in any order or combination. • If both ports are on independent loops. • Full duplex-The drive supports sending FCP_Data, FCP_RSP, FCP_XFR_RDY and ELS transfers while receiving frames on both ports. If no conflict, both ports will have two independent ...will attempt taking a soft address to open another device. Savvio 15K.1 FC Product Manual, Rev. Table 14: FC-AL options supported Option Supported OPEN Half Duplex Accepted from another device. These ports may be connected on independent loops or on independent loops and hard addressing is ...
... ports are connected in any order or combination. • If both ports are on independent loops. • Full duplex-The drive supports sending FCP_Data, FCP_RSP, FCP_XFR_RDY and ELS transfers while receiving frames on both ports. If no conflict, both ports will have two independent ...will attempt taking a soft address to open another device. Savvio 15K.1 FC Product Manual, Rev. Table 14: FC-AL options supported Option Supported OPEN Half Duplex Accepted from another device. These ports may be connected on independent loops or on independent loops and hard addressing is ...
Savvio 15K.1 FC User Guide
Page 58
... 18h N Copy 1Ah Y Mode sense Y Unit attention page (00h) Y Error recovery page (01h) 50 Savvio 15K.1 FC Product Manual, Rev. B Table 15: Supported commands Command code Supported [4] Command name 00h Y Test unit ready 01h Y Rezero unit 03h Y Request sense Y Extended sense Y Field pointer bytes Y Actual retry count bytes 04h Y Format ... 08h Y Read 0Ah Y Write 0Bh Y Seek 12h Y Inquiry Y Vital product data page (00h) Y Unit serial number page (80h) Y Implemented operating def. 9.3 SCSI commands supported Table 15 lists the SCSI commands...
... 18h N Copy 1Ah Y Mode sense Y Unit attention page (00h) Y Error recovery page (01h) 50 Savvio 15K.1 FC Product Manual, Rev. B Table 15: Supported commands Command code Supported [4] Command name 00h Y Test unit ready 01h Y Rezero unit 03h Y Request sense Y Extended sense Y Field pointer bytes Y Actual retry count bytes 04h Y Format ... 08h Y Read 0Ah Y Write 0Bh Y Seek 12h Y Inquiry Y Vital product data page (00h) Y Unit serial number page (80h) Y Implemented operating def. 9.3 SCSI commands supported Table 15 lists the SCSI commands...
Savvio 15K.1 FC User Guide
Page 59
B 51 Table 15: Supported commands (continued) Command code Supported [4] Command name Y Disconnect/reconnect control (page 02h) Y Format page (03h) Y Rigid disc drive geometry page (04h) Y Verify error recovery ... page (1Ah) Y Information exceptions control page (1Ch) 1Bh Y Start unit/stop unit 1Ch Y Receive diagnostic results Y Supported diagnostics pages Y Translate page Y Enclosure services page 1Dh Y Send diagnostics page Y Supported diagnostics pages Y Translate page 25h Y Read capacity 28h Y Read extended Y Disable page out Y Force unit access N ...
B 51 Table 15: Supported commands (continued) Command code Supported [4] Command name Y Disconnect/reconnect control (page 02h) Y Format page (03h) Y Rigid disc drive geometry page (04h) Y Verify error recovery ... page (1Ah) Y Information exceptions control page (1Ch) 1Bh Y Start unit/stop unit 1Ch Y Receive diagnostic results Y Supported diagnostics pages Y Translate page Y Enclosure services page 1Dh Y Send diagnostics page Y Supported diagnostics pages Y Translate page 25h Y Read capacity 28h Y Read extended Y Disable page out Y Force unit access N ...
Savvio 15K.1 FC User Guide
Page 60
B Table 15: Supported commands (continued) Command code Supported [4] Command name 2Fh Y Verify Y Disable page out Y Byte check N Relative address 30h N Search data high 31h N Search data equal 32h N Search data low 33h N Set ...
B Table 15: Supported commands (continued) Command code Supported [4] Command name 2Fh Y Verify Y Disable page out Y Byte check N Relative address 30h N Search data high 31h N Search data equal 32h N Search data low 33h N Set ...
Savvio 15K.1 FC User Guide
Page 61
... name N LBdata 42-4Bh N Not used 4Ch Y Log Select 4Dh Y Log Sense Y Support Log page (00h) Y Write Error Counter page (02h) Y Read Error Counter page (03h) N Read Reverse Error Counter page (04h) Y Verify Error Counter page (05h) Y Non-...
... name N LBdata 42-4Bh N Not used 4Ch Y Log Select 4Dh Y Log Sense Y Support Log page (00h) Y Write Error Counter page (02h) Y Read Error Counter page (03h) N Read Reverse Error Counter page (04h) Y Verify Error Counter page (05h) Y Non-...
Savvio 15K.1 FC User Guide
Page 62
This usually makes the drive inoperable. [3] Reference Mode Sense command 1Ah for mode pages supported. [4] Y = Yes. A = Support is supported. B N = No. Table 15: Supported commands (continued) Command code Supported [4] Command name 80h N XD write extended 81h N Rebuild 82h N Regenerate 83-8Fh N Not used A0h Y Report LUNS C0-DFh N Not used EO-FFh N Not used [1] ... Product Manual, Rev. Power loss during flash programming can format to any multiple of four bytes per logical block in firmware corruption. Command is not supported.
This usually makes the drive inoperable. [3] Reference Mode Sense command 1Ah for mode pages supported. [4] Y = Yes. A = Support is supported. B N = No. Table 15: Supported commands (continued) Command code Supported [4] Command name 80h N XD write extended 81h N Rebuild 82h N Regenerate 83-8Fh N Not used A0h Y Report LUNS C0-DFh N Not used EO-FFh N Not used [1] ... Product Manual, Rev. Power loss during flash programming can format to any multiple of four bytes per logical block in firmware corruption. Command is not supported.
Savvio 15K.1 FC User Guide
Page 64
... and conditions. B A "Y" in Mode Select command needed to save RPL and rotational offset bytes Table 18: Miscellaneous status Supported Status Y Good Y Check condition Y Condition met/good Y Busy Y Intermediate/good Y Intermediate/condition met/good Y Reservation ... full N ACA active N ACA active, faulted initiator 56 Savvio 15K.1 FC Product Manual, Rev. Table 17: Miscellaneous features Supported Feature or condition Y FC-AL selective reset N Automatic contingent allegiance N Asynchronous event notification N Synchronized (locked) spindle operation Y...
... and conditions. B A "Y" in Mode Select command needed to save RPL and rotational offset bytes Table 18: Miscellaneous status Supported Status Y Good Y Check condition Y Condition met/good Y Busy Y Intermediate/good Y Intermediate/condition met/good Y Reservation ... full N ACA active N ACA active, faulted initiator 56 Savvio 15K.1 FC Product Manual, Rev. Table 17: Miscellaneous features Supported Feature or condition Y FC-AL selective reset N Automatic contingent allegiance N Asynchronous event notification N Synchronized (locked) spindle operation Y...
Savvio 15K.1 FC User Guide
Page 68
... as possible among the voltage and ground pins. B The receiver is through the common ground pins. Two of Seagate FC products used 150 ohm impedance for operation in which makes it compatible with support for the +5 volt power supply is starting. The anode is limited by the drive when: • the drive...
... as possible among the voltage and ground pins. B The receiver is through the common ground pins. Two of Seagate FC products used 150 ohm impedance for operation in which makes it compatible with support for the +5 volt power supply is starting. The anode is limited by the drive when: • the drive...
Savvio 15K.1 FC User Guide
Page 70
...enclosure with an indication of the present function of SEL to table 23 for a description of a backpanel logic plug. The enclosure may only support the address function. B The drives does not provide pull up . 9.5.11 SEL_6 through SEL_0 ID lines The SEL_6 through SEL_0 ID lines ...the Parallel ESI line is discovered by the drive. A high level, the default state, indicates the drive requires address information on these lines. Support of ESI operation. 9.5.11.1 Parallel Enclosure Services Interface (ESI) The parallel ESI line is SEL_ID 00. Table 22: Motor start control signals Case...
...enclosure with an indication of the present function of SEL to table 23 for a description of a backpanel logic plug. The enclosure may only support the address function. B The drives does not provide pull up . 9.5.11 SEL_6 through SEL_0 ID lines The SEL_6 through SEL_0 ID lines ...the Parallel ESI line is discovered by the drive. A high level, the default state, indicates the drive requires address information on these lines. Support of ESI operation. 9.5.11.1 Parallel Enclosure Services Interface (ESI) The parallel ESI line is SEL_ID 00. Table 22: Motor start control signals Case...
Savvio 15K.1 FC User Guide
Page 72
... Manual, Rev. Reserved. Reserved. 9.5.12 Device control codes The drive inputs a Device Control Code on the DEV_CTRL_CODE lines at the same rate. Table lists the supported codes. Reserved for auto negotiation of the drive's input and output signals. Reserved. Reserved. 2.125 GHz operation on both ports. 1.0625 GHz operation on both...
... Manual, Rev. Reserved. Reserved. 9.5.12 Device control codes The drive inputs a Device Control Code on the DEV_CTRL_CODE lines at the same rate. Table lists the supported codes. Reserved for auto negotiation of the drive's input and output signals. Reserved. Reserved. 2.125 GHz operation on both ports. 1.0625 GHz operation on both...