Savvio 10K.1 SAS Product Manual
Page 4
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev. D
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev. D
Savvio 10K.1 SAS Product Manual
Page 7
Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives. Savvio family disc drive Savvio SAS Product Manual, Rev. Figure 1. The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives. D 1
Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives. Savvio family disc drive Savvio SAS Product Manual, Rev. Figure 1. The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives. D 1
Savvio 10K.1 SAS Product Manual
Page 13
...-free HDA environment. The shipping lock disengages and the head load process begins when power is sealed at the innermost radius of the media to support the Serial Attached SCSI Protocol as this requires special facilities. Savvio drives are random access storage devices designed to eliminate the possibility of this document...
...-free HDA environment. The shipping lock disengages and the head load process begins when power is sealed at the innermost radius of the media to support the Serial Attached SCSI Protocol as this requires special facilities. Savvio drives are random access storage devices designed to eliminate the possibility of this document...
Savvio 10K.1 SAS Product Manual
Page 14
... standard features: • 1.5 / 3 Gbit Serial Attached SCSI (SAS) interface • Integrated dual port SAS controller supporting the SCSI protocol • Support for improved durability and environmental protection. 3.3 Performance • Programmable multi-segmentable cache buffer • 300 Mbytes/sec maximum ...SAS interface • 64 - improved seek performance 8 Savvio SAS Product Manual, Rev. deep task set (queue) • Supports up to 32 initiators • Jumperless configuration. • User-selectable logical block size (512 to 528 bytes per logical block)...
... standard features: • 1.5 / 3 Gbit Serial Attached SCSI (SAS) interface • Integrated dual port SAS controller supporting the SCSI protocol • Support for improved durability and environmental protection. 3.3 Performance • Programmable multi-segmentable cache buffer • 300 Mbytes/sec maximum ...SAS interface • 64 - improved seek performance 8 Savvio SAS Product Manual, Rev. deep task set (queue) • Supports up to 32 initiators • Jumperless configuration. • User-selectable logical block size (512 to 528 bytes per logical block)...
Savvio 10K.1 SAS Product Manual
Page 20
... circular buffer whose length is set up or changed independently, having nothing to do with the Mode Select Disconnect/Reconnect parameters, page 02h. 2. The drive supports operation of any integer number of segments from the cache to the medium. The buffer segmentation scheme is an integer number of the cache: 1. Upon...
... circular buffer whose length is set up or changed independently, having nothing to do with the Mode Select Disconnect/Reconnect parameters, page 02h. 2. The drive supports operation of any integer number of segments from the cache to the medium. The buffer segmentation scheme is an integer number of the cache: 1. Upon...
Savvio 10K.1 SAS Product Manual
Page 45
... counts. Reallocations are also reallocated, that is, reassigned to controlling the recovery level for a single LBA. D 39 The error recovery scheme supported by the drive provides a way to control the total error recovery time for writes) is one, the RC bit is determined by the ... with the maximum possible recovery time for write. The "P" list is defined as the ETF defect list). Locations of the SCSI commands supported by the initiator using the Recovery Time Limit bytes in the "G" list (defects growth list). The drive implements selectable error recovery time limits...
... counts. Reallocations are also reallocated, that is, reassigned to controlling the recovery level for a single LBA. D 39 The error recovery scheme supported by the drive provides a way to control the total error recovery time for writes) is one, the RC bit is determined by the ... with the maximum possible recovery time for write. The "P" list is defined as the ETF defect list). Locations of the SCSI commands supported by the initiator using the Recovery Time Limit bytes in the "G" list (defects growth list). The drive implements selectable error recovery time limits...
Savvio 10K.1 SAS Product Manual
Page 51
... (part number 100293071). 9.1 SAS features This section lists the SAS-specific features supported by Savvio drives. 9.1.1 task management functions Table 15 lists the SAS task management functions supported. 9.0 Interface requirements This section partially describes the interface requirements as implemented on Savvio... drives. Table 15: SAS task management functions supported Task name Abort Task Clear ACA Supported Yes Yes Clear task set Yes Abort task set Yes Logical Unit Reset Yes Query Task Yes ...
... (part number 100293071). 9.1 SAS features This section lists the SAS-specific features supported by Savvio drives. 9.1.1 task management functions Table 15 lists the SAS task management functions supported. 9.0 Interface requirements This section partially describes the interface requirements as implemented on Savvio... drives. Table 15: SAS task management functions supported Task name Abort Task Clear ACA Supported Yes Yes Clear task set Yes Abort task set Yes Logical Unit Reset Yes Query Task Yes ...
Savvio 10K.1 SAS Product Manual
Page 52
... XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports revert back to buffer availability, the Savvio drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on condition of allowing either link rate (1.5 or 3.0 Gbits/sec). Subject to ...D If the first port to successfully complete speed negotiation sets the link rate support by the first port. These ports may be connected in speed negotiation, it indicates the only supported speed is the speed selected by both ports. The first port to complete speed...
... XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports revert back to buffer availability, the Savvio drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on condition of allowing either link rate (1.5 or 3.0 Gbits/sec). Subject to ...D If the first port to successfully complete speed negotiation sets the link rate support by the first port. These ports may be connected in speed negotiation, it indicates the only supported speed is the speed selected by both ports. The first port to complete speed...
Savvio 10K.1 SAS Product Manual
Page 53
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
Savvio 10K.1 SAS Product Manual
Page 54
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
Savvio 10K.1 SAS Product Manual
Page 55
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
Savvio 10K.1 SAS Product Manual
Page 56
... AFh 7Fh/000Ah 0Ah 2Ah AAh 8Ah 7Fh/000Bh 2Eh AEh 8Eh 7Fh/000Ch 3Bh 3Fh 9Fh/11h 41h 93h 7Fh/000Dh 52h 50h 51h Supported N N N Y Y Y Y N N N Y Y N N N Y Y Y N Y N N N N N N N [1] Savvio drives can result in the range 512 to 528 bytes. [2] Warning. This usually makes the drive inoperable. [3]... Reference Mode Sense command 1Ah for mode pages supported. [4] Y = Yes. Command is available on special request. 50 Savvio SAS Product Manual, Rev. N = No. Power loss during flash programming ...
... AFh 7Fh/000Ah 0Ah 2Ah AAh 8Ah 7Fh/000Bh 2Eh AEh 8Eh 7Fh/000Ch 3Bh 3Fh 9Fh/11h 41h 93h 7Fh/000Dh 52h 50h 51h Supported N N N Y Y Y Y N N N Y Y N N N Y Y Y N Y N N N N N N N [1] Savvio drives can result in the range 512 to 528 bytes. [2] Warning. This usually makes the drive inoperable. [3]... Reference Mode Sense command 1Ah for mode pages supported. [4] Y = Yes. Command is available on special request. 50 Savvio SAS Product Manual, Rev. N = No. Power loss during flash programming ...
Savvio 10K.1 SAS Product Manual
Page 61
...allegiance Asynchronous event notification Synchronized (locked) spindle operation Segmented caching Zero latency read Queue tagging (up to 64 queue tags supported) Deferred error handling Parameter rounding (controlled by Round bit in Mode Select page 0) Reporting actual retry count in Extended ...15, 16, and 17 Adaptive caching SMP = 1 in Mode Select command needed to save RPL and rotational offset bytes Table 22: Miscellaneous status Supported Y Y Y Y Y Y Y Y N N Status Good Check condition Condition met/good Busy Intermediate/good Intermediate/condition met/good Reservation conflict Task...
...allegiance Asynchronous event notification Synchronized (locked) spindle operation Segmented caching Zero latency read Queue tagging (up to 64 queue tags supported) Deferred error handling Parameter rounding (controlled by Round bit in Mode Select page 0) Reporting actual retry count in Extended ...15, 16, and 17 Adaptive caching SMP = 1 in Mode Select command needed to save RPL and rotational offset bytes Table 22: Miscellaneous status Supported Y Y Y Y Y Y Y Y N N Status Good Check condition Condition met/good Busy Intermediate/good Intermediate/condition met/good Reservation conflict Task...
Savvio 10K.1 SAS Product Manual
Page 66
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC - input pair S3* -Port A_in S4 Port A Ground S5* -Port A_out Diff output pair S6* +Port A_out S7 Port A Ground S8 Port...
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC - input pair S3* -Port A_in S4 Port A Ground S5* -Port A_out Diff output pair S6* +Port A_out S7 Port A Ground S8 Port...
Savvio 10K.1 SAS Product Manual
Page 71
... differential voltage (D.C. e The maximum difference between the means of the midpoint crossing times of an OOB signal). The same stable trigger, coherent to the lowest supported transfer rate. The OOB sequence is the maximum A.C.
... differential voltage (D.C. e The maximum difference between the means of the midpoint crossing times of an OOB signal). The same stable trigger, coherent to the lowest supported transfer rate. The OOB sequence is the maximum A.C.
Savvio 10K.1 SAS Product Manual
Page 79
... in your questions. Presales Support: Presales@Seagate.com Technical Support: DiscSupport@Seagate.com Warranty Support: http://www.seagate.com/support/service/index.html mySeagate my.seagate.com is available to manage their Seagate account functions. Technical Support Seagate technical support is the industry's first Web portal designed specifically for the deaf (TDD). Seagate Service Centers Presales Support Our Presales Support staff can send questions or...
... in your questions. Presales Support: Presales@Seagate.com Technical Support: DiscSupport@Seagate.com Warranty Support: http://www.seagate.com/support/service/index.html mySeagate my.seagate.com is available to manage their Seagate account functions. Technical Support Seagate technical support is the industry's first Web portal designed specifically for the deaf (TDD). Seagate Service Centers Presales Support Our Presales Support staff can send questions or...
Savvio 10K.1 SAS Product Manual
Page 80
... Middle East and Africa, go to the "Contact Us" page on www.seagate.com. Have your customer support representative for Seagate products. Asia/Pacific Support Services For an extensive list of defective products. Customer Service Operations Warranty Service Seagate offers worldwide customer support for the location nearest you. Resellers or end users of drive products should...
... Middle East and Africa, go to the "Contact Us" page on www.seagate.com. Have your customer support representative for Seagate products. Asia/Pacific Support Services For an extensive list of defective products. Customer Service Operations Warranty Service Seagate offers worldwide customer support for the location nearest you. Resellers or end users of drive products should...
Savvio 10K.1 SAS Product Manual
Page 81
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
Savvio 10K.1 SAS Product Manual
Page 82
...37 mounting configuration dimensions 37 Savvio SAS Product Manual, Rev. See MTBF media description 8 minimum sector interleave 12 miscellaneous feature support Adaptive caching 55 Asynchronous event notification 55 Automatic contingent allegiance 55 Deferred error handling 55 Parameter rounding 55 Queue tagging 55 Reporting...equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 ...
...37 mounting configuration dimensions 37 Savvio SAS Product Manual, Rev. See MTBF media description 8 minimum sector interleave 12 miscellaneous feature support Adaptive caching 55 Asynchronous event notification 55 Automatic contingent allegiance 55 Deferred error handling 55 Parameter rounding 55 Queue tagging 55 Reporting...equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 ...
Savvio 10K.1 SAS Product Manual
Page 83
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...