Cheetah 15K.5 SAS Product Manual
Page 53
... supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD...
... supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD...
Cheetah 15K.5 SAS Product Manual
Page 82
...45 intermediate/condition met/good status 56 intermediate/good status 56 internal data rate 11 internal defects/errors 37 internal drive characteristics 11 IRAW 40 J jumpers 41 L latency average rotational 11, 12 logical block address 13 logical block reallocation scheme 8 logical block size 8, 12 logical segments 13 M ...Busy 56 Check condition 56 Condition met/good 56 Good 56 Intermediate/condition met/good 56 Intermediate/good 56 Reservation conflict 56 Task set full 56 miscorrected media data 15 Mode sense data, table 51, 53 mounting 43 holes 43 orientations 41 Cheetah 15K.5 SAS Product Manual,...
...45 intermediate/condition met/good status 56 intermediate/good status 56 internal data rate 11 internal defects/errors 37 internal drive characteristics 11 IRAW 40 J jumpers 41 L latency average rotational 11, 12 logical block address 13 logical block reallocation scheme 8 logical block size 8, 12 logical segments 13 M ...Busy 56 Check condition 56 Condition met/good 56 Good 56 Intermediate/condition met/good 56 Intermediate/good 56 Reservation conflict 56 Task set full 56 miscorrected media data 15 Mode sense data, table 51, 53 mounting 43 holes 43 orientations 41 Cheetah 15K.5 SAS Product Manual,...
Cheetah 15K.5 FC Product Manual
Page 16
mands. Jumpers are set on the FC-AL backpanel or through the interface connector • Fibre Channel worldwide name uniquely identifies the drive and each port • User-selectable ... copper FC drivers and receivers • Downloadable firmware using the FC-AL interface • Supports SCSI enclosure services via interface connector • 128-deep task set (queue) • Supports up to 32 initiators • Drive selection ID and configuration options are not used on the drive. • Supports SCSI Enclosure Services...
mands. Jumpers are set on the FC-AL backpanel or through the interface connector • Fibre Channel worldwide name uniquely identifies the drive and each port • User-selectable ... copper FC drivers and receivers • Downloadable firmware using the FC-AL interface • Supports SCSI enclosure services via interface connector • 128-deep task set (queue) • Supports up to 32 initiators • Drive selection ID and configuration options are not used on the drive. • Supports SCSI Enclosure Services...
Cheetah 15K.5 FC Product Manual
Page 51
There are no jumpers, switches, or terminators on the backpanel so that no cables are used to two or more ...than 0, the device plugged into the host's 40-pin Fibre Channel backpanel connector (FC- Loop initialization is the process used , set the device selection IDs (SEL IDs) on the drive. Cheetah 15K.5 FC Product Manual, Rev. Simply plug the drive into... assigned to verify or obtain an address. The drive is not necessary to any orientation. If you set the AL_PA on the loop. If you change options after applying power to the drive, recycle the drive power to ...
There are no jumpers, switches, or terminators on the backpanel so that no cables are used to two or more ...than 0, the device plugged into the host's 40-pin Fibre Channel backpanel connector (FC- Loop initialization is the process used , set the device selection IDs (SEL IDs) on the drive. Cheetah 15K.5 FC Product Manual, Rev. Simply plug the drive into... assigned to verify or obtain an address. The drive is not necessary to any orientation. If you set the AL_PA on the loop. If you change options after applying power to the drive, recycle the drive power to ...
Cheetah 15K.5 FC Product Manual
Page 62
... data page (00h) Y Unit serial number page (80h) Y Implemented operating def. page (81h) Y Device Identification page (83h) Y Firmware numbers page (C0h) Y Date code page (C1h) Y Jumper settings page (C2h) Y Device Behavior page (C3h) Y Mode select (same pages as Mode Sense command shown below) [3] Y Reserve N 3rd party reserved N Extent reservation Y Release N Copy Y Mode...
... data page (00h) Y Unit serial number page (80h) Y Implemented operating def. page (81h) Y Device Identification page (83h) Y Firmware numbers page (C0h) Y Date code page (C1h) Y Jumper settings page (C2h) Y Device Behavior page (C3h) Y Mode select (same pages as Mode Sense command shown below) [3] Y Reserve N 3rd party reserved N Extent reservation Y Release N Copy Y Mode...
Cheetah 15K.5 FC Product Manual
Page 87
... intermediate/good status 63 Intermix 49, 52 internal data rate 11 internal defects/errors 39 internal drive characteristics 11 IRAW 42 J J1 connector 43 Jumper settings page command 54 jumpers 43 L latency average rotational 11, 12 LBdata 56 LED driver signals 72 Link Service Reject (LS_RJT) 47 link services supported 47 Lock-unlock...
... intermediate/good status 63 Intermix 49, 52 internal data rate 11 internal defects/errors 39 internal drive characteristics 11 IRAW 42 J J1 connector 43 Jumper settings page command 54 jumpers 43 L latency average rotational 11, 12 LBdata 56 LED driver signals 72 Link Service Reject (LS_RJT) 47 link services supported 47 Lock-unlock...
Cheetah 15K.7 FC Product Manual
Page 13
C 7 mands. Jumpers are not used on the drive. • Supports SCSI Enclosure...shipping lock • Embedded Grey Code track address to 32 initiators • Drive selection ID and configuration options are set on command (Post Format) • Fibre Channel interface transports SCSI protocol Cheetah 15K.7 FC SED models have the ...; Downloadable firmware using the FC-AL interface • Supports SCSI enclosure services via interface connector • 128-deep task set (queue) • Supports up to eliminate seek errors • Self-diagnostics performed at power on • Zone bit...
C 7 mands. Jumpers are not used on the drive. • Supports SCSI Enclosure...shipping lock • Embedded Grey Code track address to 32 initiators • Drive selection ID and configuration options are set on command (Post Format) • Fibre Channel interface transports SCSI protocol Cheetah 15K.7 FC SED models have the ...; Downloadable firmware using the FC-AL interface • Supports SCSI enclosure services via interface connector • 128-deep task set (queue) • Supports up to eliminate seek errors • Self-diagnostics performed at power on • Zone bit...
Cheetah 15K.7 FC Product Manual
Page 51
... drive into the backpanel's SCA connector inherits this condition. See Section 12.5 for additional information about this drive. In the event you set the device selection IDs (SEL IDs) on the loop. Loop initialization is a plug-and-play process. Table 24 provides the pin ...performance characterizations, however, have duplicate selection IDs assigned to select drive ID and all option selections in 512-byte logical blocks. SCA)-no jumpers, switches, or terminators on its side) orientations, which are made through the interface connector (J1). Use the FC-AL interface to...
... drive into the backpanel's SCA connector inherits this condition. See Section 12.5 for additional information about this drive. In the event you set the device selection IDs (SEL IDs) on the loop. Loop initialization is a plug-and-play process. Table 24 provides the pin ...performance characterizations, however, have duplicate selection IDs assigned to select drive ID and all option selections in 512-byte logical blocks. SCA)-no jumpers, switches, or terminators on its side) orientations, which are made through the interface connector (J1). Use the FC-AL interface to...
Cheetah 15K.7 FC Product Manual
Page 61
... data page (00h) Unit serial number page (80h) Implemented operating def. page (81h) Device Identification page (83h) Firmware numbers page (C0h) Date code page (C1h) Jumper settings page (C2h) Device Behavior page (C3h) Mode select (same pages as Mode Sense command shown below) [3] Reserve 3rd party reserved Extent reservation Release Copy Mode...
... data page (00h) Unit serial number page (80h) Implemented operating def. page (81h) Device Identification page (83h) Firmware numbers page (C0h) Date code page (C1h) Jumper settings page (C2h) Device Behavior page (C3h) Mode select (same pages as Mode Sense command shown below) [3] Reserve 3rd party reserved Extent reservation Release Copy Mode...
Cheetah 15K.7 FC Product Manual
Page 83
... intermediate/good status 64 Intermix 50, 53 internal data rate 10 internal defects/errors 40 internal drive characteristics 10 IRAW 44 J J1 connector 45 Jumper settings page command 55 jumpers 45 L latency average rotational 10, 11 LBdata 57 LED driver signals 73 Link Service Reject (LS_RJT) 48 link services supported 48 Locking SP...
... intermediate/good status 64 Intermix 50, 53 internal data rate 10 internal defects/errors 40 internal drive characteristics 10 IRAW 44 J J1 connector 45 Jumper settings page command 55 jumpers 45 L latency average rotational 10, 11 LBdata 57 LED driver signals 73 Link Service Reject (LS_RJT) 48 link services supported 48 Locking SP...
Cheetah 15K.7 SAS Product Manual
Page 52
... supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit Command...
... supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit Command...
Cheetah 15K.6 FC Product Manual
Page 14
... 15K.6 FC drives have it's own ownership credential and encryption key • Authenticated firmware download 8 Cheetah 15K.6 FC Product Manual, Rev. D Jumpers are not used on the drive. • Supports SCSI Enclosure Services through the interface connector • Fibre Channel worldwide name uniquely identifies the drive ...receivers • Downloadable firmware using the FC-AL interface • Supports SCSI enclosure services via interface connector • 128-deep task set (queue) • Supports up to 32 initiators • Drive selection ID and configuration options are...
... 15K.6 FC drives have it's own ownership credential and encryption key • Authenticated firmware download 8 Cheetah 15K.6 FC Product Manual, Rev. D Jumpers are not used on the drive. • Supports SCSI Enclosure Services through the interface connector • Fibre Channel worldwide name uniquely identifies the drive ...receivers • Downloadable firmware using the FC-AL interface • Supports SCSI enclosure services via interface connector • 128-deep task set (queue) • Supports up to 32 initiators • Drive selection ID and configuration options are...
Cheetah 15K.6 FC Product Manual
Page 53
...the drive into the backpanel's SCA connector inherits this drive. Use the FC-AL interface to low-level format this AL_PA. If you set the AL_PA on its side) orientations, which are 125 AL_PAs available (see Table 30). All drive performance characterizations, however, have been ...address. The drive is designed to two or more devices), the FC-AL generates a message indicating this connector. You should confirm that no jumpers, switches, or terminators on the loop. See Section 9.5 for the 40-pin Fibre Channel single connector (J1). 8.2 Drive orientation The ...
...the drive into the backpanel's SCA connector inherits this drive. Use the FC-AL interface to low-level format this AL_PA. If you set the AL_PA on its side) orientations, which are 125 AL_PAs available (see Table 30). All drive performance characterizations, however, have been ...address. The drive is designed to two or more devices), the FC-AL generates a message indicating this connector. You should confirm that no jumpers, switches, or terminators on the loop. See Section 9.5 for the 40-pin Fibre Channel single connector (J1). 8.2 Drive orientation The ...
Cheetah 15K.6 FC Product Manual
Page 64
... data page (00h) Unit serial number page (80h) Implemented operating def. D page (81h) Device Identification page (83h) Firmware numbers page (C0h) Date code page (C1h) Jumper settings page (C2h) Device Behavior page (C3h) Mode select (same pages as Mode Sense command shown below) [3] Reserve 3rd party reserved Extent reservation Release Copy Mode...
... data page (00h) Unit serial number page (80h) Implemented operating def. D page (81h) Device Identification page (83h) Firmware numbers page (C0h) Date code page (C1h) Jumper settings page (C2h) Device Behavior page (C3h) Mode select (same pages as Mode Sense command shown below) [3] Reserve 3rd party reserved Extent reservation Release Copy Mode...
Cheetah 15K.6 FC Product Manual
Page 89
... intermediate/good status 67 Intermix 53, 56 internal data rate 11 internal defects/errors 43 internal drive characteristics 11 IRAW 46 J J1 connector 47 Jumper settings page command 58 jumpers 47 L latency average rotational 11, 12 LBdata 60 LED driver signals 76 Link Service Reject (LS_RJT) 51 link services supported 51 Lock-unlock...
... intermediate/good status 67 Intermix 53, 56 internal data rate 11 internal defects/errors 43 internal drive characteristics 11 IRAW 46 J J1 connector 47 Jumper settings page command 58 jumpers 47 L latency average rotational 11, 12 LBdata 60 LED driver signals 76 Link Service Reject (LS_RJT) 51 link services supported 51 Lock-unlock...
Cheetah 15K.6 SAS Product Manual
Page 57
... supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD...
... supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD...
Cheetah 15K.6 SAS Product Manual
Page 86
.../condition met/good status 62 intermediate/good status 62 internal data rate 11 internal defects/errors 43 internal drive characteristics 11 82 IRAW 46 J jumpers 47 L latency average rotational 11, 12 logical block address 13 logical block reallocation scheme 8 logical block size 8, 12 logical segments 13 M... 62 Busy 62 Check condition 62 Condition met/good 62 Good 62 Intermediate/condition met/good 62 Intermediate/good 62 Reservation conflict 62 Task set full 62 miscorrected media data 15 Mode sense data, table 57 mounting 49 holes 49 orientations 47 N noise audible 3 noise immunity 27...
.../condition met/good status 62 intermediate/good status 62 internal data rate 11 internal defects/errors 43 internal drive characteristics 11 82 IRAW 46 J jumpers 47 L latency average rotational 11, 12 logical block address 13 logical block reallocation scheme 8 logical block size 8, 12 logical segments 13 M... 62 Busy 62 Check condition 62 Condition met/good 62 Good 62 Intermediate/condition met/good 62 Intermediate/good 62 Reservation conflict 62 Task set full 62 miscorrected media data 15 Mode sense data, table 57 mounting 49 holes 49 orientations 47 N noise audible 3 noise immunity 27...
Cheetah 15K.5 SCSI Product Manual
Page 45
... and do when installing a drive is Molex 52747-0211 (Seagate part number 77679052). If necessary see Figure 10), or via the drive to Sections 10.8 and 10.9. • Set all models. Figure 11 shows the drive's J6 jumper connector. Refer to Section 10.3.2 for installation. tor, or.... The first thing to do not cover with the standard OEM drives. Configure drive options For option jumper locations and definitions refer to set the drive SCSI ID and set -up certain operating options. These drives are needed for default mode parameters if they are designed to...
... and do when installing a drive is Molex 52747-0211 (Seagate part number 77679052). If necessary see Figure 10), or via the drive to Sections 10.8 and 10.9. • Set all models. Figure 11 shows the drive's J6 jumper connector. Refer to Section 10.3.2 for installation. tor, or.... The first thing to do not cover with the standard OEM drives. Configure drive options For option jumper locations and definitions refer to set the drive SCSI ID and set -up certain operating options. These drives are needed for default mode parameters if they are designed to...
Cheetah 15K.5 SCSI Product Manual
Page 48
...On Spindle starts immediately after 24 second delay, etc. Default setting. Default is SE jumper not installed. Default is no RES jumper installed. Drive spindle starts when Start Unit command received from host. RES Off Reserved jumper position. J6 does not exist on the LC model and... 42 Cheetah 15K.5 SCSI Product Manual, Rev. Note. Drive spindle does not start feature is overridden and does not apply when ME jumper is PD jumper not installed. Default is applied, i.e., drive 0 spindle starts immediately when DC power connected, drive 1 starts after 12 second delay, ...
...On Spindle starts immediately after 24 second delay, etc. Default setting. Default is SE jumper not installed. Default is no RES jumper installed. Drive spindle starts when Start Unit command received from host. RES Off Reserved jumper position. J6 does not exist on the LC model and... 42 Cheetah 15K.5 SCSI Product Manual, Rev. Note. Drive spindle does not start feature is overridden and does not apply when ME jumper is PD jumper not installed. Default is applied, i.e., drive 0 spindle starts immediately when DC power connected, drive 1 starts after 12 second delay, ...
Cheetah 15K.5 SCSI Product Manual
Page 52
... bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Command code 40h 39h 18h 3Ah 04h 12h Supported by Cheetah 15K...N N N Y N Y Y Y Y Y N Y Y Y Y Y Y Y Y 46 Cheetah 15K.5 SCSI Product Manual, Rev. Supported (Y = yes) (N = no) Y Y Y N Y Y Y N N Y 10.3 SCSI interface commands supported Table 8 following lists the SCSI interface commands that are shipped set to operate in Ultra320 mode.
... bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Command code 40h 39h 18h 3Ah 04h 12h Supported by Cheetah 15K...N N N Y N Y Y Y Y Y N Y Y Y Y Y Y Y Y 46 Cheetah 15K.5 SCSI Product Manual, Rev. Supported (Y = yes) (N = no) Y Y Y N Y Y Y N N Y 10.3 SCSI interface commands supported Table 8 following lists the SCSI interface commands that are shipped set to operate in Ultra320 mode.