Pulsar.2 SAS Product Manual
Page 3
B i Contents 1.0 2.0 3.0 Seagate Technology support services ...1 Scope...2 Applicable standards and reference documentation ...3.1 Standards ...3.1.1 Electromagnetic compatibility...3.1.2 Electromagnetic compliance ...3.1.3 European Union Restriction of Hazardous Substances (RoHS) ...3.1.4 China Restriction of Hazardous Substances (RoHS) ...
B i Contents 1.0 2.0 3.0 Seagate Technology support services ...1 Scope...2 Applicable standards and reference documentation ...3.1 Standards ...3.1.1 Electromagnetic compatibility...3.1.2 Electromagnetic compliance ...3.1.3 European Union Restriction of Hazardous Substances (RoHS) ...3.1.4 China Restriction of Hazardous Substances (RoHS) ...
Pulsar.2 SAS Product Manual
Page 4
... ...9.1 Data encryption ...9.2 Controlled access...9.2.1 Admin SP ...9.2.2 Locking SP ...9.2.3 Default password ...9.3 Random number generator (RNG)...9.4 Drive locking...9.5 Data bands...9.6 Cryptographic erase...9.7 Authenticated firmware download ...9.8 Power requirements ...9.9 Supported commands ...9.10 Sanitize -
... ...9.1 Data encryption ...9.2 Controlled access...9.2.1 Admin SP ...9.2.2 Locking SP ...9.2.3 Default password ...9.3 Random number generator (RNG)...9.4 Drive locking...9.5 Data bands...9.6 Cryptographic erase...9.7 Authenticated firmware download ...9.8 Power requirements ...9.9 Supported commands ...9.10 Sanitize -
Pulsar.2 SAS Product Manual
Page 9
... Pulsar.2 SAS Product Manual, Rev. For information regarding products and services, visit http://www.seagate.com/www/en-us/about/contact_us/ Available services include: Presales & Technical support Global Support Services telephone numbers & business hours Authorized Service Centers Warranty terms will vary based on type of warranty chosen: "Managed Life" or "Usage Based". B 1 Consult...
... Pulsar.2 SAS Product Manual, Rev. For information regarding products and services, visit http://www.seagate.com/www/en-us/about/contact_us/ Available services include: Presales & Technical support Global Support Services telephone numbers & business hours Authorized Service Centers Warranty terms will vary based on type of warranty chosen: "Managed Life" or "Usage Based". B 1 Consult...
Pulsar.2 SAS Product Manual
Page 10
... Disk Encryption (FDE) models before a differentiation between drive-based encryption and other Seagate SAS drives. 2.0 Scope This manual describes Seagate Technology® LLC, Pulsar®.2 SAS (Serial Attached SCSI) drives. Pulsar.2 drives support the SAS Protocol specifications to standard and Self-Encrypting Drive models. The data listed... listed or future generation products and need further assistance, please contact your Field Applications Engineer (FAE) or our global support services group as shown in this manual. Unless otherwise stated, the information in this manual.
... Disk Encryption (FDE) models before a differentiation between drive-based encryption and other Seagate SAS drives. 2.0 Scope This manual describes Seagate Technology® LLC, Pulsar®.2 SAS (Serial Attached SCSI) drives. Pulsar.2 drives support the SAS Protocol specifications to standard and Self-Encrypting Drive models. The data listed... listed or future generation products and need further assistance, please contact your Field Applications Engineer (FAE) or our global support services group as shown in this manual. Unless otherwise stated, the information in this manual.
Pulsar.2 SAS Product Manual
Page 14
...the following standard features: 1.5 / 3.0 / 6.0 Gb Serial Attached SCSI (SAS) interface Integrated dual port SAS controller supporting the SCSI protocol Support for SAS expanders and fanout adapters Firmware downloadable using the SAS interface 128 - Note. The Self-Encrypting Drive models ...4.0 General description Pulsar.2 drives provide high performance, high capacity data storage for a variety of systems with Block Unmap Support Silent operation Lifetime Endurance Management (available on the standards defined by the Trusted Computing Group (see www.trustedcomputinggroup.org). The...
...the following standard features: 1.5 / 3.0 / 6.0 Gb Serial Attached SCSI (SAS) interface Integrated dual port SAS controller supporting the SCSI protocol Support for SAS expanders and fanout adapters Firmware downloadable using the SAS interface 128 - Note. The Self-Encrypting Drive models ...4.0 General description Pulsar.2 drives provide high performance, high capacity data storage for a variety of systems with Block Unmap Support Silent operation Lifetime Endurance Management (available on the standards defined by the Trusted Computing Group (see www.trustedcomputinggroup.org). The...
Pulsar.2 SAS Product Manual
Page 17
...(9Eh) command is an increase in the products endurance. Thin Provisioning Product Configuration Table 2: Product Configuration Non-SED SED LBPME Supported Supported LBPRZ Supported Not Supported A logical block provisioning management enabled (LBPME) bit set to one indicates that the logical unit is indicated by a read...Provisioning The drive is designed with all bits set to zero to the data-in buffer. The result is defined in the Seagate SCSI Command Reference 100293068.. An unmapped block will respond to a READ command with all LBAs to become unmapped. 4.8.5 Protection Information...
...(9Eh) command is an increase in the products endurance. Thin Provisioning Product Configuration Table 2: Product Configuration Non-SED SED LBPME Supported Supported LBPRZ Supported Not Supported A logical block provisioning management enabled (LBPME) bit set to one indicates that the logical unit is indicated by a read...Provisioning The drive is designed with all bits set to zero to the data-in buffer. The result is defined in the Seagate SCSI Command Reference 100293068.. An unmapped block will respond to a READ command with all LBAs to become unmapped. 4.8.5 Protection Information...
Pulsar.2 SAS Product Manual
Page 21
...,000 48,000/15,000 [3] 23,000 22,000 Testing performed at Queue Depth = 32, Randomly Preconditioned drive, using IOMeter 2006.7.27. For models that support Lifetime Endurance Management, write values also take into account the worst case performance throttling that may occur to achieve when the product is licensed under...
...,000 48,000/15,000 [3] 23,000 22,000 Testing performed at Queue Depth = 32, Randomly Preconditioned drive, using IOMeter 2006.7.27. For models that support Lifetime Endurance Management, write values also take into account the worst case performance throttling that may occur to achieve when the product is licensed under...
Pulsar.2 SAS Product Manual
Page 31
... operation cycles is term based and includes the Lifetime Endurance Management feature stated in the original unopened Seagate shipping packaging when ever possible. Seagate recommends shipping by the Seagate Approved Package label. 6.3.7 Product warranty See Section 1.0, "Seagate Technology support services" for warranty information. Warranty terms will vary based on the shorter of term and endurance...
... operation cycles is term based and includes the Lifetime Endurance Management feature stated in the original unopened Seagate shipping packaging when ever possible. Seagate recommends shipping by the Seagate Approved Package label. 6.3.7 Product warranty See Section 1.0, "Seagate Technology support services" for warranty information. Warranty terms will vary based on the shorter of term and endurance...
Pulsar.2 SAS Product Manual
Page 52
... the RevertSP method the unique PSID (Physical Secure ID) printed on the drive label must be signed and authenticated. 3. OEM drives shall support the command. 44 Pulsar.2 SAS Product Manual, Rev. 9.7 Authenticated firmware download In addition to providing a locking mechanism to prevent unwanted firmware... exceptions and/or modifications described in this section. For example it with a new data encryption key randomly generated by the appropriate Seagate Design Center. PSID is not electronically accessible and can only be manually read from the drive label or scanned in via the 2D...
... the RevertSP method the unique PSID (Physical Secure ID) printed on the drive label must be signed and authenticated. 3. OEM drives shall support the command. 44 Pulsar.2 SAS Product Manual, Rev. 9.7 Authenticated firmware download In addition to providing a locking mechanism to prevent unwanted firmware... exceptions and/or modifications described in this section. For example it with a new data encryption key randomly generated by the appropriate Seagate Design Center. PSID is not electronically accessible and can only be manually read from the drive label or scanned in via the 2D...
Pulsar.2 SAS Product Manual
Page 53
... defined in the following technologies used to report defects via the READ DEFECT DATA command pending T10 standardization of the SCSI commands supported by the initiator using the READ DEFECT DATA command. The drive uses a vendor unique format to increase data integrity and drive...recorded on the drive Error Recovery philosophy is , marked as 110b in the SAS Interface Manual. 10.0 Defect and error management Seagate continues to use innovative technologies to increase data integrity, perform drive self-maintenance, and validate proper drive operation. The CHANNEL field ...
... defined in the following technologies used to report defects via the READ DEFECT DATA command pending T10 standardization of the SCSI commands supported by the initiator using the READ DEFECT DATA command. The drive uses a vendor unique format to increase data integrity and drive...recorded on the drive Error Recovery philosophy is , marked as 110b in the SAS Interface Manual. 10.0 Defect and error management Seagate continues to use innovative technologies to increase data integrity, perform drive self-maintenance, and validate proper drive operation. The CHANNEL field ...
Pulsar.2 SAS Product Manual
Page 55
... checking control through the CDB. Eight bytes of Protection Information appended to it is currently formatted to a single PI Type. Type 3 - Seagate products do not support Type 3. 10.6.2 Setting and determining the current Type Level A drive is initialized to a type of PI to a new Type but the...LBAs. PI formatted drives are nonzero values. The advantage of Protection Information. Type 0 - The RDPROTECT and WRTPROTECT bits allow for legacy support in the RDPROTECT and WRTPROTECT fields. Eight bytes of 32 byte commands. No other vehicle for changing the PI type is formatted to a...
... checking control through the CDB. Eight bytes of Protection Information appended to it is currently formatted to a single PI Type. Type 3 - Seagate products do not support Type 3. 10.6.2 Setting and determining the current Type Level A drive is initialized to a type of PI to a new Type but the...LBAs. PI formatted drives are nonzero values. The advantage of Protection Information. Type 0 - The RDPROTECT and WRTPROTECT bits allow for legacy support in the RDPROTECT and WRTPROTECT fields. Eight bytes of 32 byte commands. No other vehicle for changing the PI type is formatted to a...
Pulsar.2 SAS Product Manual
Page 59
....2 drives. Table 15: Task management response codes Response code 00 02 04 05 08 09 Function name Function complete Invalid frame Function not supported Function failed Function succeeded Invalid logical unit Pulsar.2 SAS Product Manual, Rev. Table 14: Task name Abort Task Abort task set Clear ACA... Clear task set I_T Nexus Reset Logical Unit Reset Query Task Query Task Set Query Asynchronous Event SAS task management functions supported Supported Yes Yes Yes Yes Yes Yes Yes Yes Yes 12.1.2 Task management responses Table 15 lists the SAS response codes returned for task...
....2 drives. Table 15: Task management response codes Response code 00 02 04 05 08 09 Function name Function complete Invalid frame Function not supported Function failed Function succeeded Invalid logical unit Pulsar.2 SAS Product Manual, Rev. Table 14: Task name Abort Task Abort task set Clear ACA... Clear task set I_T Nexus Reset Logical Unit Reset Query Task Query Task Set Query Asynchronous Event SAS task management functions supported Supported Yes Yes Yes Yes Yes Yes Yes Yes Yes 12.1.2 Task management responses Table 15 lists the SAS response codes returned for task...
Pulsar.2 SAS Product Manual
Page 60
... two independent ports. B Subject to buffer availability, the Pulsar.2 drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on both ports at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports ...can run at 6Gb/s or the first port can run at 6Gb/s while the second port runs at 3Gb/s.) The supported link rates are 1.5, 3.0, or 6.0 Gb/s. These ports may be connected in the same or different SCSI domains. Each drive port has a...
... two independent ports. B Subject to buffer availability, the Pulsar.2 drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on both ports at the same time. • Full duplex-The drive supports sending XFER_RDY, DATA and RESPONSE transfers while receiving frames on both ports ...can run at 6Gb/s or the first port can run at 6Gb/s while the second port runs at 3Gb/s.) The supported link rates are 1.5, 3.0, or 6.0 Gb/s. These ports may be connected in the same or different SCSI domains. Each drive port has a...
Pulsar.2 SAS Product Manual
Page 61
... 16 lists the SCSI commands supported by Pulsar.2 drives. B 53 Table 16: Supported commands Command code Supported Command name CHANGE DEFINITION FORMAT UNIT [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) INQUIRY Block Limits page (... page (83h) Extended Inquiry Data page (86h) Firmware Numbers page (C0h) Jumper Settings page (C2h) Power Conditions page (8Ah) Supported Vital Product Data page (00h) Thin Provisioning page (B2h) Unit Serial Number page (80h) Vendor Unique page (D1h) Vendor Unique page...
... 16 lists the SCSI commands supported by Pulsar.2 drives. B 53 Table 16: Supported commands Command code Supported Command name CHANGE DEFINITION FORMAT UNIT [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) INQUIRY Block Limits page (... page (83h) Extended Inquiry Data page (86h) Firmware Numbers page (C0h) Jumper Settings page (C2h) Power Conditions page (8Ah) Supported Vital Product Data page (00h) Thin Provisioning page (B2h) Unit Serial Number page (80h) Vendor Unique page (D1h) Vendor Unique page...
Pulsar.2 SAS Product Manual
Page 62
... n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Protocol-Specific Port log pages (18h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) ... Control page (10h) MODE SENSE (10) (same pages as MODE SENSE (6)) PERSISTENT RESERVE IN PERSISTENT RESERVE OUT PRE-FETCH (10) READ (6) READ (10) DPO bit supported FUA bit supported READ (12) READ (16) 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h N N Y Y Y Y N Y Y Y Y Y Y Y Y [3] Y Y [3] Y Y Y Y N Y Y N Y Y Y N Y Y N Y Y Y N Y Y Y Y ...
... n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Protocol-Specific Port log pages (18h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) ... Control page (10h) MODE SENSE (10) (same pages as MODE SENSE (6)) PERSISTENT RESERVE IN PERSISTENT RESERVE OUT PRE-FETCH (10) READ (6) READ (10) DPO bit supported FUA bit supported READ (12) READ (16) 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h N N Y Y Y Y N Y Y Y Y Y Y Y Y [3] Y Y [3] Y Y Y Y N Y Y N Y Y Y N Y Y N Y Y Y N Y Y Y Y ...
Pulsar.2 SAS Product Manual
Page 63
... (16) READ DEFECT DATA (10) READ DEFECT DATA (12) READ LONG (10) READ LONG (16) REASSIGN BLOCKS RECEIVE DIAGNOSTIC RESULTS Supported Diagnostics pages (00h) Translate page (40h) RELEASE (6) RELEASE (10) REPORT LUNS REQUEST SENSE Actual Retry Count bytes Extended Sense Field Pointer bytes... Extent Reservation REZERO UNIT SANITIZE Overwrite Block Erase Cryptographic Erase SECURITY PROTOCOL IN SECURITY PROTOCOL OUT SEEK (6) SEEK (10) SEND DIAGNOSTICS Supported Diagnostics pages (00h) Translate page (40h) START UNIT/STOP UNIT SYNCHRONIZE CACHE SYNCHRONIZE CACHE (16) TEST UNIT READY UNMAP 7Fh/...
... (16) READ DEFECT DATA (10) READ DEFECT DATA (12) READ LONG (10) READ LONG (16) REASSIGN BLOCKS RECEIVE DIAGNOSTIC RESULTS Supported Diagnostics pages (00h) Translate page (40h) RELEASE (6) RELEASE (10) REPORT LUNS REQUEST SENSE Actual Retry Count bytes Extended Sense Field Pointer bytes... Extent Reservation REZERO UNIT SANITIZE Overwrite Block Erase Cryptographic Erase SECURITY PROTOCOL IN SECURITY PROTOCOL OUT SEEK (6) SEEK (10) SEND DIAGNOSTICS Supported Diagnostics pages (00h) Translate page (40h) START UNIT/STOP UNIT SYNCHRONIZE CACHE SYNCHRONIZE CACHE (16) TEST UNIT READY UNMAP 7Fh/...
Pulsar.2 SAS Product Manual
Page 64
...Manual, Rev. Warning. This usually makes the drive inoperable. B A = Support is supported. Reference MODE SENSE command 1Ah for mode pages supported. Y = Yes. N = No. Command is not supported. Table 16: Supported commands Command code Supported Command name VERIFY (10) BYTCHK bit VERIFY (12) VERIFY (16) VERIFY...WRITE AND VERIFY (10) DPO bit WRITE AND VERIFY (12) WRITE AND VERIFY (16) WRITE AND VERIFY (32) WRITE BUFFER (modes 0, 2, supported) WRITE BUFFER Firmware Download option (modes 5, 7, Ah and Bh) [2] Firmware Download option (modes 4, 5, 7) WRITE LONG (10) WRITE LONG ...
...Manual, Rev. Warning. This usually makes the drive inoperable. B A = Support is supported. Reference MODE SENSE command 1Ah for mode pages supported. Y = Yes. N = No. Command is not supported. Table 16: Supported commands Command code Supported Command name VERIFY (10) BYTCHK bit VERIFY (12) VERIFY (16) VERIFY...WRITE AND VERIFY (10) DPO bit WRITE AND VERIFY (12) WRITE AND VERIFY (16) WRITE AND VERIFY (32) WRITE BUFFER (modes 0, 2, supported) WRITE BUFFER Firmware Download option (modes 5, 7, Ah and Bh) [2] Firmware Download option (modes 4, 5, 7) WRITE LONG (10) WRITE LONG ...
Pulsar.2 SAS Product Manual
Page 65
... the appropriate SPC release documentation for definitions. 10 = INQUIRY data for an INQUIRY command received on Port A. 30 = INQUIRY data for Model ST800FM0002. SCSI Revision support. The table above shows the hex values for an INQUIRY command received on Port B.
... the appropriate SPC release documentation for definitions. 10 = INQUIRY data for an INQUIRY command received on Port A. 30 = INQUIRY data for Model ST800FM0002. SCSI Revision support. The table above shows the hex values for an INQUIRY command received on Port B.
Pulsar.2 SAS Product Manual
Page 71
... in MODE SELECT page 0) Reporting actual retry count in the SAS Interface Manual. The operational aspects of Seagate's SAS drives are provided within this section. A "Y" in the support column indicates the feature or condition is supported. Figures 18 and 19 provide the dimensions of the physical, electrical, and logical characteristics are provided in...
... in MODE SELECT page 0) Reporting actual retry count in the SAS Interface Manual. The operational aspects of Seagate's SAS drives are provided within this section. A "Y" in the support column indicates the feature or condition is supported. Figures 18 and 19 provide the dimensions of the physical, electrical, and logical characteristics are provided in...
Pulsar.2 SAS Product Manual
Page 74
B The SAS device connector is designed to support hot plugging NC - Short pin to either plug directly into a backpanel or accept cables. 12.4.5 Pin descriptions This section provides a pin-out of the SAS ...
B The SAS device connector is designed to support hot plugging NC - Short pin to either plug directly into a backpanel or accept cables. 12.4.5 Pin descriptions This section provides a pin-out of the SAS ...