Savvio 10K.1 SAS Product Manual
Page 4
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev.
... 43 8.4 Grounding 43 9.0 Interface requirements 45 9.1 SAS features 45 9.1.1 task management functions 45 9.1.2 task management responses 45 9.2 Dual port support 46 9.3 SCSI commands supported 47 9.3.1 Inquiry data 51 9.3.2 Mode Sense data 51 9.4 Miscellaneous operating features and conditions 55 9.4.1 SAS physical interface 56 9.4.2 Physical characteristics ... SAS transmitters and receivers 60 9.4.7 Power 61 9.5 Signal characteristics 61 9.5.1 Ready LED Out 61 9.5.2 Differential signals 61 10.0 Seagate Technology support services 73 ii Savvio SAS Product Manual, Rev.
Savvio 10K.1 SAS Product Manual
Page 7
Savvio family disc drive Savvio SAS Product Manual, Rev. The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. D 1 Figure 1. Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives.
Savvio family disc drive Savvio SAS Product Manual, Rev. The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of this manual. D 1 Figure 1. Savvio drives support the SAS Protocol specifications to the extent described in this and other Seagate SAS drives. 1.0 Scope This manual describes Seagate Technology® LLC, Savvio® SAS (Serial Attached SCSI) disc drives.
Savvio 10K.1 SAS Product Manual
Page 13
... recirculates within the HDA through a nonreplaceable filter to the drive. Note. The SAS connectors, cables and electrical interface are random access storage devices designed to support the Serial Attached SCSI Protocol as this drive. The shipping lock disengages and the head load process begins when power is removed from the servo...
... recirculates within the HDA through a nonreplaceable filter to the drive. Note. The SAS connectors, cables and electrical interface are random access storage devices designed to support the Serial Attached SCSI Protocol as this drive. The shipping lock disengages and the head load process begins when power is removed from the servo...
Savvio 10K.1 SAS Product Manual
Page 14
... standard features: • 1.5 / 3 Gbit Serial Attached SCSI (SAS) interface • Integrated dual port SAS controller supporting the SCSI protocol • Support for improved durability and environmental protection. 3.3 Performance • Programmable multi-segmentable cache buffer • 300 Mbytes/sec maximum ...instantaneous data transfers. • 10k RPM spindle. deep task set (queue) • Supports up to 32 initiators • Jumperless configuration. • User-selectable logical block size (512 to the drive • Zone ...
... standard features: • 1.5 / 3 Gbit Serial Attached SCSI (SAS) interface • Integrated dual port SAS controller supporting the SCSI protocol • Support for improved durability and environmental protection. 3.3 Performance • Programmable multi-segmentable cache buffer • 300 Mbytes/sec maximum ...instantaneous data transfers. • 10k RPM spindle. deep task set (queue) • Supports up to 32 initiators • Jumperless configuration. • User-selectable logical block size (512 to the drive • Zone ...
Savvio 10K.1 SAS Product Manual
Page 20
... written there at the beginning of the cache. Divide the 6,900 Kbytes in accordance with the Mode Select Disconnect/Reconnect parameters, page 02h. 2. The drive supports operation of a drive buffer storage area where the data to be generated. The size of the Mode Select parameters page 08h. If an error occurs...
... written there at the beginning of the cache. Divide the 6,900 Kbytes in accordance with the Mode Select Disconnect/Reconnect parameters, page 02h. 2. The drive supports operation of a drive buffer storage area where the data to be generated. The size of the Mode Select parameters page 08h. If an error occurs...
Savvio 10K.1 SAS Product Manual
Page 45
The "P" list is not counted against the recovery time limit. Details of the SCSI commands supported by the drive in LBA recovery is zero, and the recovery time limit for the command has not yet been met. The total amount of ... Limit bytes in the Error Recovery mode page. Also, more information on the drive primary defects list (referred to perform reallocations. The error recovery scheme supported by the initiator using several SCSI commands described in error recovery for read and write retry count with this section. The drive firmware error recovery...
The "P" list is not counted against the recovery time limit. Details of the SCSI commands supported by the drive in LBA recovery is zero, and the recovery time limit for the command has not yet been met. The total amount of ... Limit bytes in the Error Recovery mode page. Also, more information on the drive primary defects list (referred to perform reallocations. The error recovery scheme supported by the initiator using several SCSI commands described in error recovery for read and write retry count with this section. The drive firmware error recovery...
Savvio 10K.1 SAS Product Manual
Page 51
... This section partially describes the interface requirements as implemented on Savvio drives. Table 15: SAS task management functions supported Task name Abort Task Clear ACA Supported Yes Yes Clear task set Yes Abort task set Yes Logical Unit Reset Yes Query Task Yes 9.1.2 task ... 16 lists the SAS response codes returned for task management functions supported. Table 16: Task management response codes Function name Function complete Response code 00 Invalid frame 02 Function not supported 04 Function failed 05 Function succeeded 08 Invalid logical unit 09 Savvio...
... This section partially describes the interface requirements as implemented on Savvio drives. Table 15: SAS task management functions supported Task name Abort Task Clear ACA Supported Yes Yes Clear task set Yes Abort task set Yes Logical Unit Reset Yes Query Task Yes 9.1.2 task ... 16 lists the SAS response codes returned for task management functions supported. Table 16: Task management response codes Function name Function complete Response code 00 Invalid frame 02 Function not supported 04 Function failed 05 Function succeeded 08 Invalid logical unit 09 Savvio...
Savvio 10K.1 SAS Product Manual
Page 52
...receiving frames on condition of allowing either link rate (1.5 or 3.0 Gbits/sec). Subject to buffer availability, the Savvio drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on both ports at the same link rate. D If the first port to complete ... negotiation looses sync before the second port completes speed negotiation, both ports revert back to successfully complete speed negotiation sets the link rate support by the first port. The first port to the power on both ports. Each drive port has a unique SAS address. When...
...receiving frames on condition of allowing either link rate (1.5 or 3.0 Gbits/sec). Subject to buffer availability, the Savvio drives support: • Concurrent port transfers-The drive supports receiving COMMAND, TASK management transfers on both ports at the same link rate. D If the first port to complete ... negotiation looses sync before the second port completes speed negotiation, both ports revert back to successfully complete speed negotiation sets the link rate support by the first port. The first port to the power on both ports. Each drive port has a unique SAS address. When...
Savvio 10K.1 SAS Product Manual
Page 53
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
... Savvio SAS family drive Command name Change Definition Compare Copy Copy and Verify Format Unit [1] DPRY bit supported DCRT bit supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented ...Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock cache Log Select PCR bit DU bit DS bit TSD bit ETC...
Savvio 10K.1 SAS Product Manual
Page 54
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
... drive (continued) Command name Last n Deferred Errors or Asynchronous Events page (0Bh) Last n Error Events page (07h) Non-medium Error page (06h) Pages Supported list (00h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Self-test Results page (10h) Start-stop Cycle Counter page (0Eh) ... (same pages as Mode Sense 1Ah) Persistent Reserve In Persistent Reserve Out Prefetch Read (6) Read (10) DPO bit supported FUA bit supported Read (12) Read (16) Read (32) Read Buffer (modes 0, 2, 3, Ah and Bh supported) Command code 15h 55h 1Ah 5Ah 5Eh 5Fh 34h 08h 28h A8h 88h 7Fh/0009h 3Ch...
Savvio 10K.1 SAS Product Manual
Page 55
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
... Read Capacity (16) Read Defect Data (10) Read Defect Data (12) Read Long Read Long (16) Reassign Blocks Receive Diagnostic Results Supported Diagnostics pages (00h) Translate page (40h) Release Release (10) Report LUNs Request Sense Actual Retry Count bytes Extended Sense Field Pointer bytes ... (10) 3rd Party Reserve Extent Reservation Rezero Unit Search Data Equal Search Data High Search Data Low Seek (6) Seek (10) Send Diagnostics Supported Diagnostics pages (00h) Translate page (40h) Set Limits Start Unit/Stop Unit (spindle ceases rotating) Synchronize Cache Synchronize Cache (16) Test ...
Savvio 10K.1 SAS Product Manual
Page 56
... loss during flash programming can format to any multiple of four bytes per logical block in firmware corruption. N = No. Table 17: Commands supported by Savvio SAS family drive (continued) Command name Verify (12) Verify (16) Verify (32) Write (6) Write (10) DPO bit FUA bit Write (12...and Verify (10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Firmware Download option (modes 5, 7, Ah and Bh supported) [3] Write Long (10) Write Long (16) Write Same (10) PBdata LBdata Write Same (16) Write Same (32) XDRead XDWrite XPWrite...
... loss during flash programming can format to any multiple of four bytes per logical block in firmware corruption. N = No. Table 17: Commands supported by Savvio SAS family drive (continued) Command name Verify (12) Verify (16) Verify (32) Write (6) Write (10) DPO bit FUA bit Write (12...and Verify (10) DPO bit Write and Verify (12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Firmware Download option (modes 5, 7, Ah and Bh supported) [3] Write Long (10) Write Long (16) Write Same (10) PBdata LBdata Write Same (16) Write Same (32) XDRead XDWrite XPWrite...
Savvio 10K.1 SAS Product Manual
Page 61
9.4 Miscellaneous operating features and conditions Table 21 lists various features and conditions. An "N" in the support column indicates the feature or condition is supported. Table 21: Miscellaneous features Supported N N N Y N Y Y Y Y N Y Feature or condition Automatic contingent allegiance Asynchronous event notification ...Synchronized (locked) spindle operation Segmented caching Zero latency read Queue tagging (up to 64 queue tags supported) Deferred error handling Parameter rounding (controlled by Round bit in Mode Select page 0) Reporting actual retry count...
9.4 Miscellaneous operating features and conditions Table 21 lists various features and conditions. An "N" in the support column indicates the feature or condition is supported. Table 21: Miscellaneous features Supported N N N Y N Y Y Y Y N Y Feature or condition Automatic contingent allegiance Asynchronous event notification ...Synchronized (locked) spindle operation Segmented caching Zero latency read Queue tagging (up to 64 queue tags supported) Deferred error handling Parameter rounding (controlled by Round bit in Mode Select page 0) Reporting actual retry count...
Savvio 10K.1 SAS Product Manual
Page 66
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC - SAS transmitters and receivers .01 RX Receiver 100 .01 RY 60 Savvio SAS Product Manual, Rev. The receiver is shown in the...
... 12 Volts charge P14 12 Volts * P15 12 Volts * 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is AC coupling to support hot plugging NC - SAS transmitters and receivers .01 RX Receiver 100 .01 RY 60 Savvio SAS Product Manual, Rev. The receiver is shown in the...
Savvio 10K.1 SAS Product Manual
Page 71
... difference between the burst times and the idle times of the Tx+ signal and the Tx- All specifications are measured from 20 % to the lowest supported transfer rate. d Rise/fall timed Maximum transmitter output imbalancee OOB offset deltaf OOB common mode deltag Units ps mV(P-P) ps ps % mV mV 1.5 Gbps 20...
... difference between the burst times and the idle times of the Tx+ signal and the Tx- All specifications are measured from 20 % to the lowest supported transfer rate. d Rise/fall timed Maximum transmitter output imbalancee OOB offset deltaf OOB common mode deltag Units ps mV(P-P) ps ps % mV mV 1.5 Gbps 20...
Savvio 10K.1 SAS Product Manual
Page 79
...-324-3655) is the industry's first Web portal designed specifically for the call centers. spp.seagate.com spp.seagate.com supports Seagate resellers with a technical support specialist during normal business hours for OEMs and distributors. You can help you online at support.seagate.com or through a single, password-protected Web interface-anytime, anywhere in the world. It...
...-324-3655) is the industry's first Web portal designed specifically for the call centers. spp.seagate.com spp.seagate.com supports Seagate resellers with a technical support specialist during normal business hours for OEMs and distributors. You can help you online at support.seagate.com or through a single, password-protected Web interface-anytime, anywhere in the world. It...
Savvio 10K.1 SAS Product Manual
Page 80
... go to the "Contact Us" page on www.seagate.com. Have your customer support representative for the return of defective products. Global Customer Support Presales, Technical, and Warranty Support Call Center Toll-free USA, Canada, and Mexico 1-800-SEAGATE Data Recovery Services Call Center USA, Canada, and.../ Canada/Latin America, including business hours, go to the "Contact Us" page on www.seagate.com. Asia/Pacific Support Services For an extensive list of telephone numbers to technical support, presales and warranty service in Asia/Pacific, go to the "Contact Us" page on a...
... go to the "Contact Us" page on www.seagate.com. Have your customer support representative for the return of defective products. Global Customer Support Presales, Technical, and Warranty Support Call Center Toll-free USA, Canada, and Mexico 1-800-SEAGATE Data Recovery Services Call Center USA, Canada, and.../ Canada/Latin America, including business hours, go to the "Contact Us" page on www.seagate.com. Asia/Pacific Support Services For an extensive list of telephone numbers to technical support, presales and warranty service in Asia/Pacific, go to the "Contact Us" page on a...
Savvio 10K.1 SAS Product Manual
Page 81
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
...11 case temperature 32 check condition status 55 class B limit 3 clear ACA function 45 clear task set function 45 commands supported 47 condensation 32 condition met/good status 55 connector illustrated 59 requirements 59 continuous vibration 35 cooling 42 CRC error 18 Current...speed 11 drive 35 drive characteristics 11 drive failure 18 drive malfunction 18 drive mounting 37, 43 drive select 59 dual port support 46 E electrical description of connector 59 signal characteristics 61 specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 36 EMI requirements 3 environment ...
Savvio 10K.1 SAS Product Manual
Page 82
...42 host equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 intermediate/good ...17 maximum delayed motor start 25, 26 maximum start current 25, 26 mean time between failure. D See HDA heads read 55 miscellaneous status support ACA active 55 ACA active, faulted initiator 55 Busy 55 Check condition 55 Condition met/good 55 Good 55 Intermediate/condition met/good 55 ...
...42 host equipment 43 hot plugging the drive 19 humidity 32 humidity limits 32 I inquiry data 51 installation 41 guide 5 interface commands supported 47 error rate 17 errors 18 illustrated 56 physical 56 requirements 45 interleave minimum 12 intermediate/condition met/good status 55 intermediate/good ...17 maximum delayed motor start 25, 26 maximum start current 25, 26 mean time between failure. D See HDA heads read 55 miscellaneous status support ACA active 55 ACA active, faulted initiator 55 Busy 55 Check condition 55 Condition met/good 55 Good 55 Intermediate/condition met/good 55 ...
Savvio 10K.1 SAS Product Manual
Page 83
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...
... return information 24 rotation speed 11 S safety 3 SAS interface 59 physical interface 56 task management functions 45 SAS documents 5 SAS Interface Manual 3, 5 SCSI interface commands supported 47 seek error defined 18 rate 17 seek performance characteristics 11 seek time average typical 11 full stroke typical 11 single track typical 11 segmented...