Constellation ES.2 SAS Product Manual
Page 4
... 35 9.2.1 Admin SP 35 9.2.2 Locking SP 35 9.2.3 Default password 36 9.3 Random number generator (RNG 36 9.4 Drive locking 36 9.5 Data bands 36 9.6 Cryptographic erase 36 9.7 Authenticated firmware download 37 9.8 Power requirements 37 9.9 Supported commands 37 9.10 RevertSP 37 10.0 Defect and error management 38 10.1 Drive internal defects/errors 38 10.2 Drive...
... 35 9.2.1 Admin SP 35 9.2.2 Locking SP 35 9.2.3 Default password 36 9.3 Random number generator (RNG 36 9.4 Drive locking 36 9.5 Data bands 36 9.6 Cryptographic erase 36 9.7 Authenticated firmware download 37 9.8 Power requirements 37 9.9 Supported commands 37 9.10 RevertSP 37 10.0 Defect and error management 38 10.1 Drive internal defects/errors 38 10.2 Drive...
Constellation ES.2 SAS Product Manual
Page 16
... data bands • Cryptographic erase of user data for a drive that will be repurposed or scrapped • Authenticated firmware download 4.2 Media description The media used on command (Post Format) • ECC maximum burst correction length of 400 ... a aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 128 - 4.1 Standard features Constellation ES.2 drives have the following standard features: • Perpendicular recording...
... data bands • Cryptographic erase of user data for a drive that will be repurposed or scrapped • Authenticated firmware download 4.2 Media description The media used on command (Post Format) • ECC maximum burst correction length of 400 ... a aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 128 - 4.1 Standard features Constellation ES.2 drives have the following standard features: • Perpendicular recording...
Constellation ES.2 SAS Product Manual
Page 24
...of measuring off -line attributes and force the drive to determine the time remaining before an actual failure occurs. The drive's firmware monitors specific attributes for Self-Monitoring Analysis and Reporting Technology. Each monitored attribute has been selected to monitor a specific set ,... C resets the timer so that caused a predictive failure can measure off -line attribute data and saving data to one, the firmware will not perform off-line functions. Caution. You can 't predict instantaneous drive failures. with the RTZ command resets the timer. monitors...
...of measuring off -line attributes and force the drive to determine the time remaining before an actual failure occurs. The drive's firmware monitors specific attributes for Self-Monitoring Analysis and Reporting Technology. Each monitored attribute has been selected to monitor a specific set ,... C resets the timer so that caused a predictive failure can measure off -line attribute data and saving data to one, the firmware will not perform off-line functions. Caution. You can 't predict instantaneous drive failures. with the RTZ command resets the timer. monitors...
Constellation ES.2 SAS Product Manual
Page 25
... the error rate is sent to the host to determine if the warning is a separate Failure History Counter for each monitored attribute are recorded. The firmware keeps a running count of the number of the parameter field. Saves a S.M.A.R.T. The temperature is unacceptable. The current algorithm implements two temperature trip points. The first...
... the error rate is sent to the host to determine if the warning is a separate Failure History Counter for each monitored attribute are recorded. The firmware keeps a running count of the number of the parameter field. Saves a S.M.A.R.T. The temperature is unacceptable. The current algorithm implements two temperature trip points. The first...
Constellation ES.2 SAS Product Manual
Page 43
...the media and when it is authorized to perform the command. 9.2.1 Admin SP The Admin SP allows the drive's owner to enable or disable firmware download operations (see Section 9.5). 9.2 Controlled access The drive has two security partitions (SPs) called the "Admin SP" and the "Locking SP."...band has its own password called BandMasterX where X is used to convey the TCG protocol to and from the performance of the drive. Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as gatekeepers to the drive security services. These drives are...
...the media and when it is authorized to perform the command. 9.2.1 Admin SP The Admin SP allows the drive's owner to enable or disable firmware download operations (see Section 9.5). 9.2 Controlled access The drive has two security partitions (SPs) called the "Admin SP" and the "Locking SP."...band has its own password called BandMasterX where X is used to convey the TCG protocol to and from the performance of the drive. Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as gatekeepers to the drive security services. These drives are...
Constellation ES.2 SAS Product Manual
Page 44
When the drive is shipped from the factory, the firmware download port is unlocked. 9.5 Data bands When shipped from the factory, the drive is configured with a single data band called Band 0 (also known as the ...
When the drive is shipped from the factory, the firmware download port is unlocked. 9.5 Data bands When shipped from the factory, the drive is configured with a single data band called Band 0 (also known as the ...
Constellation ES.2 SAS Product Manual
Page 45
... drive models. 9.9 Supported commands The SED models support the following two commands in addition to the commands supported by the appropriate Seagate Design Center. The download must be rejected. 2. As with a non-SED drive, the download file must pass the acceptance ...supply. A standard (base) drive (non-SED) file will allow the download operation: 1. 9.7 Authenticated firmware download In addition to providing a locking mechanism to prevent unwanted firmware download attempts, the drive also only accepts download files which have identical hardware, however the security and ...
... drive models. 9.9 Supported commands The SED models support the following two commands in addition to the commands supported by the appropriate Seagate Design Center. The download must be rejected. 2. As with a non-SED drive, the download file must pass the acceptance ...supply. A standard (base) drive (non-SED) file will allow the download operation: 1. 9.7 Authenticated firmware download In addition to providing a locking mechanism to prevent unwanted firmware download attempts, the drive also only accepts download files which have identical hardware, however the security and ...
Constellation ES.2 SAS Product Manual
Page 46
...unusable, and their locations recorded on the medium and the location listed in communications between the initiator and the drive). The drive firmware error recovery algorithms consist of the SCSI commands supported by the drive provides a way to controlling the recovery level for the ...described in LBA recovery is not altered after drive shipment are designed to manage defects and errors. 10.0 Defect and error management Seagate continues to use innovative technologies to increase data integrity, perform drive self-maintenance, and validate proper drive operation. The "P" list is...
...unusable, and their locations recorded on the medium and the location listed in communications between the initiator and the drive). The drive firmware error recovery algorithms consist of the SCSI commands supported by the drive provides a way to controlling the recovery level for the ...described in LBA recovery is not altered after drive shipment are designed to manage defects and errors. 10.0 Defect and error management Seagate continues to use innovative technologies to increase data integrity, perform drive self-maintenance, and validate proper drive operation. The "P" list is...
Constellation ES.2 SAS Product Manual
Page 55
... supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock...
... supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock...
Constellation ES.2 SAS Product Manual
Page 58
...(12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Write Buffer Firmware Download option (modes 5, 7, Ah and Bh) [3] Firmware Download option (modes 4, 5, 7) Write Long (10) Write Long (16) Write Same (10) PBdata LBdata ...N Y N Y Y N Y N Y (non-SED drives only) Y (non-SED drives only) Y (SED drives only) Y Y Y N N Y N N N N [1] Constellation ES.2 drives can result in firmware corruption. Command is not supported. C Command is supported. A = Support is available on special request. 50 Constellation ES.2 SAS Product Manual, Rev. Power loss during flash...
...(12) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Write Buffer Firmware Download option (modes 5, 7, Ah and Bh) [3] Firmware Download option (modes 4, 5, 7) Write Long (10) Write Long (16) Write Same (10) PBdata LBdata ...N Y N Y Y N Y N Y (non-SED drives only) Y (non-SED drives only) Y (SED drives only) Y Y Y N N Y N N N N [1] Constellation ES.2 drives can result in firmware corruption. Command is not supported. C Command is supported. A = Support is available on special request. 50 Constellation ES.2 SAS Product Manual, Rev. Power loss during flash...
Constellation ES.2 SAS Product Manual
Page 59
...last four digits of mode parameters: 1. The table above shows the hex values for definitions. The drive maintains four sets of the product firmware release number. These default values can be changed by this method. An attempt to the initiator per the format given in the SAS ...parameter values that are not changeable by downloading a complete set up new current and saved values, where the values are hard-coded in the drive firmware stored in flash E-PROM (nonvolatile memory) on the drive's media using a Mode Select command. Parameters in a Mode Select command to change the ...
...last four digits of mode parameters: 1. The table above shows the hex values for definitions. The drive maintains four sets of the product firmware release number. These default values can be changed by this method. An attempt to the initiator per the format given in the SAS ...parameter values that are not changeable by downloading a complete set up new current and saved values, where the values are hard-coded in the drive firmware stored in flash E-PROM (nonvolatile memory) on the drive's media using a Mode Select command. Parameters in a Mode Select command to change the ...
Constellation ES.2 SAS Product Manual
Page 60
...used by the drive in nonvolatile memory, that dictates which indicates that in the row entitled "CHG." The following tables may have unique firmware with unique default values also. indicates if default value is not changeable. Some drives may not exactly match those fields are all of the...to change the values identified as changeable values. These are shipped configured this way. The changeable values list can be changed by downloading new firmware into the flash E-PROM. Note. In byte 02, hex value FF equates to the binary pattern 11111111. Note also that bit is 00h...
...used by the drive in nonvolatile memory, that dictates which indicates that in the row entitled "CHG." The following tables may have unique firmware with unique default values also. indicates if default value is not changeable. Some drives may not exactly match those fields are all of the...to change the values identified as changeable values. These are shipped configured this way. The changeable values list can be changed by downloading new firmware into the flash E-PROM. Note. In byte 02, hex value FF equates to the binary pattern 11111111. Note also that bit is 00h...
Constellation ES.2 SAS Product Manual
Page 70
... error management 38 rates 14 errors 38 European Union 4 F FCC rules and regulations 3 features 8 interface 45 feed forward equalizer 60 FFE 60 FIPS 34 firmware 8 corruption 50 firmware download port 36 flawed sector reallocation 8 Format command execution time 11 function complete, code 00 45 not supported, code 05 45 reject, code 04...
... error management 38 rates 14 errors 38 European Union 4 F FCC rules and regulations 3 features 8 interface 45 feed forward equalizer 60 FFE 60 FIPS 34 firmware 8 corruption 50 firmware download port 36 flawed sector reallocation 8 Format command execution time 11 function complete, code 00 45 not supported, code 05 45 reject, code 04...
Constellation ES.1 SAS Product Manual
Page 4
... 43 9.2.1 Admin SP 43 9.2.2 Locking SP 43 9.2.3 Default password 44 9.3 Random number generator (RNG 44 9.4 Drive locking 44 9.5 Data bands 44 9.6 Cryptographic erase 44 9.7 Authenticated firmware download 44 9.8 Power requirements 45 9.9 Supported commands 45 9.10 RevertSP 45 10.0 Defect and error management 46 10.1 Drive internal defects/errors 46 10.2 Drive...
... 43 9.2.1 Admin SP 43 9.2.2 Locking SP 43 9.2.3 Default password 44 9.3 Random number generator (RNG 44 9.4 Drive locking 44 9.5 Data bands 44 9.6 Cryptographic erase 44 9.7 Authenticated firmware download 44 9.8 Power requirements 45 9.9 Supported commands 45 9.10 RevertSP 45 10.0 Defect and error management 46 10.1 Drive internal defects/errors 46 10.2 Drive...
Constellation ES.1 SAS Product Manual
Page 16
...16 independent data bands • Cryptographic erase of user data for a drive that will be repurposed or scrapped • Authenticated firmware download 4.2 Media description The media used on command (Post Format) • ECC maximum burst correction length of 400 bits ...aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 128 - improved seek performance Note. 4.1 Standard features Constellation ES.1 drives have the following ...
...16 independent data bands • Cryptographic erase of user data for a drive that will be repurposed or scrapped • Authenticated firmware download 4.2 Media description The media used on command (Post Format) • ECC maximum burst correction length of 400 bits ...aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 128 - improved seek performance Note. 4.1 Standard features Constellation ES.1 drives have the following ...
Constellation ES.1 SAS Product Manual
Page 24
... technology is intended to recognize conditions that indicate imminent drive failure and is considered to an unacceptable level. The drive's firmware monitors specific attributes for degradation over which errors occur and signals a predictive failure if the rate of a failure to allow...Forcing S.M.A.R.T. attribute data is saved to the host an 01-5D00 sense code. The drive measures and saves parameters once every one , the firmware will not perform off-line functions. This time is an acronym for a given attribute. S.M.A.R.T. is required to an idle period on the Informational...
... technology is intended to recognize conditions that indicate imminent drive failure and is considered to an unacceptable level. The drive's firmware monitors specific attributes for degradation over which errors occur and signals a predictive failure if the rate of a failure to allow...Forcing S.M.A.R.T. attribute data is saved to the host an 01-5D00 sense code. The drive measures and saves parameters once every one , the firmware will not perform off-line functions. This time is an acronym for a given attribute. S.M.A.R.T. is required to an idle period on the Informational...
Constellation ES.1 SAS Product Manual
Page 25
... point is a separate Failure History Counter for each attribute is performing unacceptably for the current interval. signals predictive failures when the drive is unacceptable. The firmware keeps a running count of the number of errors for a period of 0 to as the Failure Counter. There is set this information to determine if the...
... point is a separate Failure History Counter for each attribute is performing unacceptably for the current interval. signals predictive failures when the drive is unacceptable. The firmware keeps a running count of the number of errors for a period of 0 to as the Failure Counter. There is set this information to determine if the...
Constellation ES.1 SAS Product Manual
Page 51
... is the number of the data band (0 through 15). The encryption engines are always in Section 3.2. Access to enable or disable firmware download operations (see Section 9.5). 9.2 Controlled access The drive has two security providers (SPs) called BandMasterX where X is inaccessible to ...the media and the cryptographic erase feature. Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as "protection of data at rest." The 32-byte ...
... is the number of the data band (0 through 15). The encryption engines are always in Section 3.2. Access to enable or disable firmware download operations (see Section 9.5). 9.2 Controlled access The drive has two security providers (SPs) called BandMasterX where X is inaccessible to ...the media and the cryptographic erase feature. Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as "protection of data at rest." The 32-byte ...
Constellation ES.1 SAS Product Manual
Page 52
... unwanted firmware download attempts, the drive also only accepts download files which comprises LBA 0 through Band15) but they must be set to use , including using these bands can only be read or write requests until the bands have been cryptographically signed by the appropriate Seagate Design ...additional 14 Data Bands may allocate Band1 by the host electronically over the interface. When the drive is shipped from the factory, the firmware download port is unlocked 9.5 Data bands When shipped from its own user-supplied password. This 32-byte random value can be allocated ...
... unwanted firmware download attempts, the drive also only accepts download files which comprises LBA 0 through Band15) but they must be set to use , including using these bands can only be read or write requests until the bands have been cryptographically signed by the appropriate Seagate Design ...additional 14 Data Bands may allocate Band1 by the host electronically over the interface. When the drive is shipped from the factory, the firmware download port is unlocked 9.5 Data bands When shipped from its own user-supplied password. This 32-byte random value can be allocated ...
Constellation ES.1 SAS Product Manual
Page 55
... management and its use in that respect is described in sections where the various commands are discussed. Constellation ES.1 SAS Product Manual, Rev. The drive firmware error recovery algorithms consist of 12 levels for read command can take up to 483.14ms recovery time for each block and a maximum of 450ms...
... management and its use in that respect is described in sections where the various commands are discussed. Constellation ES.1 SAS Product Manual, Rev. The drive firmware error recovery algorithms consist of 12 levels for read command can take up to 483.14ms recovery time for each block and a maximum of 450ms...