NP115 : RS232 codes- Projectors
Page 1
... connection with a personal computer or another device. Connection Method 3. List of Commands 5. Control Commands for NEC Projector (Basic) Rev 02.03.11a Copyright (C) NEC Display Solutions, Ltd. 2002-2010 Updated on February 3, 2011 This file contains information about NEC projector control commands. Model Name GT60 : GT5000/GT6000 Series GT50 : GT1150/GT2150 Series HT : HT1000/HT1100...
... connection with a personal computer or another device. Connection Method 3. List of Commands 5. Control Commands for NEC Projector (Basic) Rev 02.03.11a Copyright (C) NEC Display Solutions, Ltd. 2002-2010 Updated on February 3, 2011 This file contains information about NEC projector control commands. Model Name GT60 : GT5000/GT6000 Series GT50 : GT1150/GT2150 Series HT : HT1000/HT1100...
NP115 : RS232 codes- Projectors
Page 2
LAN connection using the LAN port on the projector A LAN cable is required Status of connection methods are required. 3-2. LAN connection using a wired LAN card A wired LAN card and LAN cable are available for ... card A wireless LAN card is required. 3-3.LAN connection using a wireless LAN unit A wireless LAN unit is required. 3-4. Serial connection using the USB port on the projector A serial cable is required. 3. LAN connection 3-1. USB connection using the serial port on the...
LAN connection using the LAN port on the projector A LAN cable is required Status of connection methods are required. 3-2. LAN connection using a wired LAN card A wired LAN card and LAN cable are available for ... card A wireless LAN card is required. 3-3.LAN connection using a wireless LAN unit A wireless LAN unit is required. 3-4. Serial connection using the USB port on the projector A serial cable is required. 3. LAN connection 3-1. USB connection using the serial port on the...
NP115 : RS232 codes- Projectors
Page 4
...: (!1) Only the NP600/NP610/NP3200 series is compatible. (!2) Only the M300 series is a D-SUB 9-pin connector. The projector cannot use the control commands in the standby mode. Setting method: Under projector [Projector Options] --> [Setup], enter a check for [Idle Mode] on Page 4. ( CAUTION ) (!1) Before making connections, be...PC CONTROL connector is a mini DIN 8-pin connector. 1 To TxD of PC 2 3 4 To GND of PC 5 6 7 To RxD of the projector and set the "idle mode". (CAUTION) Before making connections, be sure to invalidate the standby mode of PC 8 * 2, 3, 5, 6, and 8 are used...
...: (!1) Only the NP600/NP610/NP3200 series is compatible. (!2) Only the M300 series is a D-SUB 9-pin connector. The projector cannot use the control commands in the standby mode. Setting method: Under projector [Projector Options] --> [Setup], enter a check for [Idle Mode] on Page 4. ( CAUTION ) (!1) Before making connections, be...PC CONTROL connector is a mini DIN 8-pin connector. 1 To TxD of PC 2 3 4 To GND of PC 5 6 7 To RxD of the projector and set the "idle mode". (CAUTION) Before making connections, be sure to invalidate the standby mode of PC 8 * 2, 3, 5, 6, and 8 are used...
NP115 : RS232 codes- Projectors
Page 5
... |5|6| ~ | n | m | | 8 | 8 | 8 | 4 | 12 | 8 | ~ | 8 | 8 | | Bit | Bit | Bit |Bit| Bit | Bit | ~ | Bit | Bit | | | || | Data length Model code Projector ID ID2 ID1 * ID1: (8 Bit) This is done in a frame composed of PC 9 4. Frame Format One frame comprises a header, a data portion, and a checksum. Command : This... sets an identification data assigned to each command to each command description.) Command | | | Controller | | Projector | | | Response (ACK or NAK) 4-1. 1 2 To TxD of PC 3 To RxD of PC 4 5 To GND of ...
... |5|6| ~ | n | m | | 8 | 8 | 8 | 4 | 12 | 8 | ~ | 8 | 8 | | Bit | Bit | Bit |Bit| Bit | Bit | ~ | Bit | Bit | | | || | Data length Model code Projector ID ID2 ID1 * ID1: (8 Bit) This is done in a frame composed of PC 9 4. Frame Format One frame comprises a header, a data portion, and a checksum. Command : This... sets an identification data assigned to each command to each command description.) Command | | | Controller | | Projector | | | Response (ACK or NAK) 4-1. 1 2 To TxD of PC 3 To RxD of PC 4 5 To GND of ...
NP115 : RS232 codes- Projectors
Page 6
... following model codes is required. * Model code: (4 Bit) This is connected with multiple projectors To control a certain projector, use "individual notification". Command : This specifies a projector ID for the projector that sends and receives commands. (individual notification) Entering 00H or FFH becomes a common command for...it . ( See each command. Response : This returns the 6th bit of received ID1 as is. * Projector ID : (8 Bit) This is a projector ID for the projector that sends and receives frames. Command : This sets an identification data assigned to each command to send it...
... following model codes is required. * Model code: (4 Bit) This is connected with multiple projectors To control a certain projector, use "individual notification". Command : This specifies a projector ID for the projector that sends and receives commands. (individual notification) Entering 00H or FFH becomes a common command for...it . ( See each command. Response : This returns the 6th bit of received ID1 as is. * Projector ID : (8 Bit) This is a projector ID for the projector that sends and receives frames. Command : This sets an identification data assigned to each command to send it...
NP115 : RS232 codes- Projectors
Page 7
... description.) Response : This sets data length of data added to a response to "broadcast notification", the command becomes broadcast notification command, regardless of values of the projector ID. * Model code is data length of data portion (unit:: byte). Data portion of individual notification or broadcast notification. For all others "broadcast notification" is... data length of data added to a command to send it. ( See each command description.) * Checksum This is recommended. Response : This returns the model code for a projector received regardless of response
... description.) Response : This sets data length of data added to a response to "broadcast notification", the command becomes broadcast notification command, regardless of values of the projector ID. * Model code is data length of data portion (unit:: byte). Data portion of individual notification or broadcast notification. For all others "broadcast notification" is... data length of data added to a command to send it. ( See each command description.) * Checksum This is recommended. Response : This returns the model code for a projector received regardless of response
NP115 : RS232 codes- Projectors
Page 10
... ON 023. POWER OFF 018. LAMP MODE REQUEST 039. REMOTE KEY CODE 060. INPUT SW CHANGE 020. ONSCREEN MUTE OFF 030. GAIN PARAMETER REQUEST 2 077. PROJECTOR INFORMATION REQUEST 00H 81H 00H 00H 00H 81H 00H C0H 00H 00H 00H C0H 00H 88H 00H 00H 00H 88H 02H 00H 00H 00H 00H...
... ON 023. POWER OFF 018. LAMP MODE REQUEST 039. REMOTE KEY CODE 060. INPUT SW CHANGE 020. ONSCREEN MUTE OFF 030. GAIN PARAMETER REQUEST 2 077. PROJECTOR INFORMATION REQUEST 00H 81H 00H 00H 00H 81H 00H C0H 00H 00H 00H C0H 00H 88H 00H 00H 00H 88H 02H 00H 00H 00H 00H...
NP115 : RS232 codes- Projectors
Page 12
...NP62/NP43/NP64 and P350X/350W/420X, the term "RGB connector" has been changed to the immediately preceding data. Command Descriptions Precautions with Inscriptions: (*1) Projector ID It is the value of the error number at the time of "6-2. This reflects the... "Projector ID" that has been set to the projector. (*2) Model code: "xxH" inscription This will differ depending on the projector. LT30 : NP4000: NP4001: NP62 : firmware version 1.03 or later firmware version 1.04 or later firmware version 1.01...
...NP62/NP43/NP64 and P350X/350W/420X, the term "RGB connector" has been changed to the immediately preceding data. Command Descriptions Precautions with Inscriptions: (*1) Projector ID It is the value of the error number at the time of "6-2. This reflects the... "Projector ID" that has been set to the projector. (*2) Model code: "xxH" inscription This will differ depending on the projector. LT30 : NP4000: NP4001: NP62 : firmware version 1.03 or later firmware version 1.04 or later firmware version 1.01...
NP115 : RS232 codes- Projectors
Page 13
... = During execution Bit 4: External control mode 0 = OFF 1 = ON Bit 3: No Power-Off period 0 = Power-Off Possible (Normal condition) 1 = Power-Off Impossible Bit 2: Reserved Bit 1: Projector status 0 = Idling 1 = Power On Bit 0: Reserved Response: At the time of a success Command: 00H C0H 00H 00H 00H C0H Response: At the time of a failure... A0H 81H 01H xxH 02H DATA1H DATA02 CKS (*1) (*2) (*4) (*3) 007. COMMON DATA REQUEST Function: This command acquires all of the detailed conditions of the projector. RUNNING SENSE Function: This command acquires the operation mode of the...
... = During execution Bit 4: External control mode 0 = OFF 1 = ON Bit 3: No Power-Off period 0 = Power-Off Possible (Normal condition) 1 = Power-Off Impossible Bit 2: Reserved Bit 1: Projector status 0 = Idling 1 = Power On Bit 0: Reserved Response: At the time of a success Command: 00H C0H 00H 00H 00H C0H Response: At the time of a failure... A0H 81H 01H xxH 02H DATA1H DATA02 CKS (*1) (*2) (*4) (*3) 007. COMMON DATA REQUEST Function: This command acquires all of the detailed conditions of the projector. RUNNING SENSE Function: This command acquires the operation mode of the...
NP115 : RS232 codes- Projectors
Page 14
20H C0H 01H xxH 80H DATA01 .. DATA128 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Projector type See DATA70..71 08H : NP4000 Projector 11H : NP62 Projector DATA02 Projector ID DATA02 1 .. 64 NP4000 1 .. 254 NP62/NP64 1 .. 254 NP216 DATA03 Reserved DATA04 Projector status 00H: Idling 01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During execution DATA06...
20H C0H 01H xxH 80H DATA01 .. DATA128 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Projector type See DATA70..71 08H : NP4000 Projector 11H : NP62 Projector DATA02 Projector ID DATA02 1 .. 64 NP4000 1 .. 254 NP62/NP64 1 .. 254 NP216 DATA03 Reserved DATA04 Projector status 00H: Idling 01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During execution DATA06...
NP115 : RS232 codes- Projectors
Page 16
DATA66 Forced On-screen mute 00H : OFF 01H : ON DATA67 On-screen display 00H : No display 01H : Displaying DATA68 Selecting signal processing 00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling (Error occurrence) Other than above: (nondisclosure) Internal use of code during a state transition period DATA70 .. 71 Projector type
DATA66 Forced On-screen mute 00H : OFF 01H : ON DATA67 On-screen display 00H : No display 01H : Displaying DATA68 Selecting signal processing 00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling (Error occurrence) Other than above: (nondisclosure) Internal use of code during a state transition period DATA70 .. 71 Projector type
NP115 : RS232 codes- Projectors
Page 19
... the time of a failure A0H 88H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) ERROR STATUS REQUEST Function: This command acquires the error information occurring with the projector.
... the time of a failure A0H 88H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) ERROR STATUS REQUEST Function: This command acquires the error information occurring with the projector.
NP115 : RS232 codes- Projectors
Page 20
... the time of a failure A2H 00H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector does not accept the other command during power on the main power of the projector. Supplement: (!) LT/LT80/HT: "None" 015. Command: 02H 01H 00H 00H 00H 03H Response: At...the time of a failure A2H 01H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector doesn't accept the other command during power off the main power of the projector. Command: 02H 03H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 Switching object 00H : ...
... the time of a failure A2H 00H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector does not accept the other command during power on the main power of the projector. Supplement: (!) LT/LT80/HT: "None" 015. Command: 02H 01H 00H 00H 00H 03H Response: At...the time of a failure A2H 01H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector doesn't accept the other command during power off the main power of the projector. Command: 02H 03H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 Switching object 00H : ...
NP115 : RS232 codes- Projectors
Page 27
...DATA83 .. 86 : Lamp Hour Meter (second) (!) DATA87 .. 90 : Filter Usage (second) DATA91 .. 94 : Panel Usage (second) DATA95 .. 98 : Projector Usage (second) Response: At the time of a failure A3H 8AH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: (!) Lamp Hour Meter This ...is displayed in terms of Normal mode values. value will change to 5400000 seconds * The projector's hours of projector. LAMP INFORMATION REQUEST Function: This command acquires the lamp information (in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to...
...DATA83 .. 86 : Lamp Hour Meter (second) (!) DATA87 .. 90 : Filter Usage (second) DATA91 .. 94 : Panel Usage (second) DATA95 .. 98 : Projector Usage (second) Response: At the time of a failure A3H 8AH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: (!) Lamp Hour Meter This ...is displayed in terms of Normal mode values. value will change to 5400000 seconds * The projector's hours of projector. LAMP INFORMATION REQUEST Function: This command acquires the lamp information (in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to...
NP115 : RS232 codes- Projectors
Page 29
LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in terms of Eco mode values) Response: At the time of a success 23H 96H 01H xxH 06H DATA01 .. value will change to Decimal - Command: ...
LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in terms of Eco mode values) Response: At the time of a success 23H 96H 01H xxH 06H DATA01 .. value will change to Decimal - Command: ...
NP115 : RS232 codes- Projectors
Page 30
... values) 03H 96H 00H 00H 02H 00H 08H A3H Example of Eco mode values) LAMP INFORMATION REQUEST 4 Function: This command acquires the information on the projector lamp. It is the lamp total usage. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS (*3) Data Portion Contents DATA01 Target 00H : Lamp1 01H... (in terms of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is not supported. 037-7.
... values) 03H 96H 00H 00H 02H 00H 08H A3H Example of Eco mode values) LAMP INFORMATION REQUEST 4 Function: This command acquires the information on the projector lamp. It is the lamp total usage. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS (*3) Data Portion Contents DATA01 Target 00H : Lamp1 01H... (in terms of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is not supported. 037-7.
NP115 : RS232 codes- Projectors
Page 31
... acquires the setting of the lamp mode of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) It is displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time. (!5) NP4000/4001, NP4100/4100W : This function is the lamp total...B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Setting Value 00H : Normal 01H : Eco Response: At the time of projector. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) Lamp Hour Meter This is the timer for normal lamp mode conversion. (!3) Lamp usage time...
... acquires the setting of the lamp mode of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) It is displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time. (!5) NP4000/4001, NP4100/4100W : This function is the lamp total...B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Setting Value 00H : Normal 01H : Eco Response: At the time of projector. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) Lamp Hour Meter This is the timer for normal lamp mode conversion. (!3) Lamp usage time...
NP115 : RS232 codes- Projectors
Page 32
... B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 C3H fixed DATA02 Setting Value 00H : OFF 01H : ON Response: At the time of projector. WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) LAMP... 23H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Results 00H : Normal 01H : Error Response: At the time of projector. 039.
... B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 C3H fixed DATA02 Setting Value 00H : OFF 01H : ON Response: At the time of projector. WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) LAMP... 23H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Results 00H : Normal 01H : Error Response: At the time of projector. 039.
NP115 : RS232 codes- Projectors
Page 33
Table of projector. 049. WXGA MODE SETTING SET Function: This command sets the WXGA Mode of Response Error Codes Command: 03H B1H 00H 00H 02H DATA01 DATA02 CKS (*3) ...
Table of projector. 049. WXGA MODE SETTING SET Function: This command sets the WXGA Mode of Response Error Codes Command: 03H B1H 00H 00H 02H DATA01 DATA02 CKS (*3) ...
NP115 : RS232 codes- Projectors
Page 34
Specified terminal is unavailable or cannot be selected. Setting not possible. REMOTE KEY CODE Function: This command sends remote control key codes of projector. Command: 02H 0FH 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 .. 02 : Remote control key code (Word type) Key number DATA01 DATA02 Key ...
Specified terminal is unavailable or cannot be selected. Setting not possible. REMOTE KEY CODE Function: This command sends remote control key codes of projector. Command: 02H 0FH 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 .. 02 : Remote control key code (Word type) Key number DATA01 DATA02 Key ...