NP115 : RS232 codes- Projectors
Page 12
...60H 70H D0H D0H D0H D0H 80H 90H (*3) Checksum: "CKS" inscription This is the value of the lower 8 bits of the results calculated in byte units from all of an error. Example: 20H 81H 01H 60H 01H 00H 03H CKS (*4) Response error number This is the ... LT380, NP1000/NP2000, NP1150/NP2150/NP3150/NP3151W, NP1250/NP2250/NP3250/NP3250W, NP1200/NP2200, NP4000/NP4001, NP4100/NP4100W, NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S, This reflects the "Projector ID" that has been set to the immediately preceding data. LT30 : NP4000: NP4001: NP62 : firmware version 1.03 or later firmware version ...
...60H 70H D0H D0H D0H D0H 80H 90H (*3) Checksum: "CKS" inscription This is the value of the lower 8 bits of the results calculated in byte units from all of an error. Example: 20H 81H 01H 60H 01H 00H 03H CKS (*4) Response error number This is the ... LT380, NP1000/NP2000, NP1150/NP2150/NP3150/NP3151W, NP1250/NP2250/NP3250/NP3250W, NP1200/NP2200, NP4000/NP4001, NP4100/NP4100W, NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S, This reflects the "Projector ID" that has been set to the immediately preceding data. LT30 : NP4000: NP4001: NP62 : firmware version 1.03 or later firmware version ...
NP115 : RS232 codes- Projectors
Page 27
... C0H 65H 52H 00H : Total 5400000 seconds/3600 = 1500 hours 00H E4H 57H 00H : Total 5760000 seconds/3600 = 1600 hours Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to 5400000 seconds * The projector's hours of use is displayed in terms of Normal mode (values) of...
... C0H 65H 52H 00H : Total 5400000 seconds/3600 = 1500 hours 00H E4H 57H 00H : Total 5760000 seconds/3600 = 1600 hours Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to 5400000 seconds * The projector's hours of use is displayed in terms of Normal mode (values) of...
NP115 : RS232 codes- Projectors
Page 28
... At the time of Normal mode values) : Lamp Hour Meter (Normal mode) DATA01 DATA02 DATA03 DATA04 30H 2AH 00H 00H : 10800 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA12 DATA11 DATA10 DATA09 (006DDD00) 3) Change from HEX to Decimal - Command: 03H 94H 00H 00H 00H 97H ...Response: At the time of Normal mode values) DATA09 DATA10 DATA11 DATA12 00H DDH 6DH 00H : 7200000 second Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA04 DATA03 DATA02 DATA01 (00002A30) 3) Change from HEX to Decimal - value will change to 7200000 seconds ...
... At the time of Normal mode values) : Lamp Hour Meter (Normal mode) DATA01 DATA02 DATA03 DATA04 30H 2AH 00H 00H : 10800 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA12 DATA11 DATA10 DATA09 (006DDD00) 3) Change from HEX to Decimal - Command: 03H 94H 00H 00H 00H 97H ...Response: At the time of Normal mode values) DATA09 DATA10 DATA11 DATA12 00H DDH 6DH 00H : 7200000 second Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA04 DATA03 DATA02 DATA01 (00002A30) 3) Change from HEX to Decimal - value will change to 7200000 seconds ...
NP115 : RS232 codes- Projectors
Page 29
LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in terms of Eco mode values) Response: At the time of Normal mode values) 0AH : Remaining time until lamp warning message starts to Decimal - ... 96H 00H 00H 02H 00H 01H 9CH Example of acquisition DATA03 DATA04 DATA05 DATA06: lamp's use of hours 50H 46H 00H 00H: 18000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA06 DATA05 DATA04 DATA03 (00004650) 3) Change from HEX to appear (in terms of Eco mode values) 10H : Remaining time until...
LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in terms of Eco mode values) Response: At the time of Normal mode values) 0AH : Remaining time until lamp warning message starts to Decimal - ... 96H 00H 00H 02H 00H 01H 9CH Example of acquisition DATA03 DATA04 DATA05 DATA06: lamp's use of hours 50H 46H 00H 00H: 18000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA06 DATA05 DATA04 DATA03 (00004650) 3) Change from HEX to appear (in terms of Eco mode values) 10H : Remaining time until...
NP115 : RS232 codes- Projectors
Page 30
...values) 03H 96H 00H 00H 02H 00H 08H A3H Example of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA06 DATA05 DATA04 DATA03 (00057E40) 3) Change from HEX to appear (in terms of Eco mode values) 10H :...of lamp usage (in terms of Normal mode values) 0AH : Remaining time until lamp warning message starts to Decimal - It is displayed in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is the lamp total usage. value will change to 360000 seconds Remaining time until lamp ...
...values) 03H 96H 00H 00H 02H 00H 08H A3H Example of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA06 DATA05 DATA04 DATA03 (00057E40) 3) Change from HEX to appear (in terms of Eco mode values) 10H :...of lamp usage (in terms of Normal mode values) 0AH : Remaining time until lamp warning message starts to Decimal - It is displayed in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is the lamp total usage. value will change to 360000 seconds Remaining time until lamp ...
Installation Guide
Page 1
..., use the figures in the table. • All calculations are based on a 4:3 aspect ratio. • Distances are in inches, for the desired screen size. Use the Screen Formulas below . NP600S Installation Guide Ceiling Mounted and Desktop Contents Product Description, Lens...Pg 2 Pg 3-4 Pg 5 Pg 6 Pg 7 NEC Display Solutions of 7 For proper projection placement, determine the image width for millimeters multiply by 25.4. • Distances may vary ±5%. Plug in the Projection Formulas. Rev 1.5 Product Description Type: 3 panel LCD projector, 0.63" p-Si TFT w/MLA Resolution: 1024 x...
..., use the figures in the table. • All calculations are based on a 4:3 aspect ratio. • Distances are in inches, for the desired screen size. Use the Screen Formulas below . NP600S Installation Guide Ceiling Mounted and Desktop Contents Product Description, Lens...Pg 2 Pg 3-4 Pg 5 Pg 6 Pg 7 NEC Display Solutions of 7 For proper projection placement, determine the image width for millimeters multiply by 25.4. • Distances may vary ±5%. Plug in the Projection Formulas. Rev 1.5 Product Description Type: 3 panel LCD projector, 0.63" p-Si TFT w/MLA Resolution: 1024 x...