Installation Instructions
Page 1
... happen if the instructions are very important. Table of Contents MICROWAVE HOOD COMBINATION SAFETY 1 INSTALLATION REQUIREMENTS 2 Tools and Parts 2 Remove Cardboard Template 2 Location Requirements 2 Product Dimensions 3 Electrical Requirements 3 INSTALLATION INSTRUCTIONS 4 Remove Mounting Plate 4 Rotate Blower Motor 4 Locate Wall Stud(s 6 Mark Rear Wall 7 Drill Holes in this manual and on your particular...
... happen if the instructions are very important. Table of Contents MICROWAVE HOOD COMBINATION SAFETY 1 INSTALLATION REQUIREMENTS 2 Tools and Parts 2 Remove Cardboard Template 2 Location Requirements 2 Product Dimensions 3 Electrical Requirements 3 INSTALLATION INSTRUCTIONS 4 Remove Mounting Plate 4 Rotate Blower Motor 4 Locate Wall Stud(s 6 Mark Rear Wall 7 Drill Holes in this manual and on your particular...
Installation Instructions
Page 2
... Requirements Check the opening . ■ Support for cooking. Special Requirements For Wall Venting Installation Only: ■ Cutout must provide: ■ Minimum installation dimensions. Toggle nuts (2) E. 1/4" x 2" lag screws (2) F. See "Installation Dimensions" illustration. ■ Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and minimum 3/8" (10 mm) thickness drywall or plaster/lath within cabinet opening...
... Requirements Check the opening . ■ Support for cooking. Special Requirements For Wall Venting Installation Only: ■ Cutout must provide: ■ Minimum installation dimensions. Toggle nuts (2) E. 1/4" x 2" lag screws (2) F. See "Installation Dimensions" illustration. ■ Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and minimum 3/8" (10 mm) thickness drywall or plaster/lath within cabinet opening...
Installation Instructions
Page 3
...not use an extension cord. SAVE THESE INSTRUCTIONS 3 See "Electrical Requirements" section. Required: ■ A 120 Volt, 60 Hz, AC only, 15- Product Dimensions 17¹⁄₄" (43.8 cm) 16¹⁄₄" (41.3 cm) (411.06¹c⁄₈m") 29⁷⁄₈" (76.0 ...supply cord is typical for the electric current. or 20-amp electrical supply with a grounding plug. Exact dimensions may vary depending on type of range/cooktop below. Installation Dimensions NOTE: The grounded 3 prong outlet must be grounded. Recommended: ■ A time-delay fuse or ...
...not use an extension cord. SAVE THESE INSTRUCTIONS 3 See "Electrical Requirements" section. Required: ■ A 120 Volt, 60 Hz, AC only, 15- Product Dimensions 17¹⁄₄" (43.8 cm) 16¹⁄₄" (41.3 cm) (411.06¹c⁄₈m") 29⁷⁄₈" (76.0 ...supply cord is typical for the electric current. or 20-amp electrical supply with a grounding plug. Exact dimensions may vary depending on type of range/cooktop below. Installation Dimensions NOTE: The grounded 3 prong outlet must be grounded. Recommended: ■ A time-delay fuse or ...
Installation Instructions
Page 7
... made in Step 4. Installation for No Wall Studs at both end holes are not over wall studs, use two 1/4-20 x 3" round-head bolts with the dimensions described in Step 9 to the wall at End Holes (Figures 1 & 2) 1. Mark Rear Wall The microwave oven must be 14¹⁄₈" (35.9 cm) from...
... made in Step 4. Installation for No Wall Studs at both end holes are not over wall studs, use two 1/4-20 x 3" round-head bolts with the dimensions described in Step 9 to the wall at End Holes (Figures 1 & 2) 1. Mark Rear Wall The microwave oven must be 14¹⁄₈" (35.9 cm) from...
Installation Instructions
Page 8
... into the wall stud at the other hole marked in Step 2 of mounting plate, making sure it is maintained. Make sure the 10" (25.4 cm) dimension from the back of the tiles rather than the drywall). 4. Drill 3/16" (5 mm) holes into the studs at the end holes marked in Step 3 of...
... into the wall stud at the other hole marked in Step 2 of mounting plate, making sure it is maintained. Make sure the 10" (25.4 cm) dimension from the back of the tiles rather than the drywall). 4. Drill 3/16" (5 mm) holes into the studs at the end holes marked in Step 3 of...
Dimension Guide
Page 1
...m) straight = 8 ft (2.4 m) B C 3" (7.6 cm) D A. Roof cap B. 6" (15.2 cm) min. Microwave Hood Combination PRODUCT MODEL NUMBERS MMV1164W MMV4203W MMV5208W MMV6180W MMV6186W Electrical: A 120-Volt, 60-Hz, AC-only, 15- It is recommended that the damper can open freely and fully. 2 ft A (0.6 m) C A. To ... continuous commitment to change without notice. For complete details, see Installation our products, we reserve the right to improve Dimensions are for Roof Venting NOTE: The minimum 3" (7.6 cm) clearance must be provided. Rectangular to round transition piece: ...
...m) straight = 8 ft (2.4 m) B C 3" (7.6 cm) D A. Roof cap B. 6" (15.2 cm) min. Microwave Hood Combination PRODUCT MODEL NUMBERS MMV1164W MMV4203W MMV5208W MMV6180W MMV6186W Electrical: A 120-Volt, 60-Hz, AC-only, 15- It is recommended that the damper can open freely and fully. 2 ft A (0.6 m) C A. To ... continuous commitment to change without notice. For complete details, see Installation our products, we reserve the right to improve Dimensions are for Roof Venting NOTE: The minimum 3" (7.6 cm) clearance must be provided. Rectangular to round transition piece: ...