Installation Instructions
Page 4
...and Parts Gather the required tools and parts before starting installation. Check that all models): Tape measure Pliers Utility knife Tin snips (new vent installations) Leveling legs (4) Parts needed (steam models): "Y" connector 2' (0.6 m) inlet hose Caulking gun and compound (new vent... installations) Adjustable wrench that opens to propane gas Parts supplied (all parts are included. NOTE: Do not use leveling legs supplied with dryer if installing with dryer): ■■ ...
...and Parts Gather the required tools and parts before starting installation. Check that all models): Tape measure Pliers Utility knife Tin snips (new vent installations) Leveling legs (4) Parts needed (steam models): "Y" connector 2' (0.6 m) inlet hose Caulking gun and compound (new vent... installations) Adjustable wrench that opens to propane gas Parts supplied (all parts are included. NOTE: Do not use leveling legs supplied with dryer if installing with dryer): ■■ ...
Installation Instructions
Page 5
... electrical supply and venting. You may use with upturned ends. ■■ A UL Listed strain relief. Maytag® Models IMPORTANT: Do not operate, install, or store dryer where it will need: ■■ A location allowing for an electric dryer. ■■ If using a power supply cord: Use a UL Listed power supply cord kit marked...
... electrical supply and venting. You may use with upturned ends. ■■ A UL Listed strain relief. Maytag® Models IMPORTANT: Do not operate, install, or store dryer where it will need: ■■ A location allowing for an electric dryer. ■■ If using a power supply cord: Use a UL Listed power supply cord kit marked...
Installation Instructions
Page 6
... transfer. ■■ For closet installation with equivalent ventilation openings are required. Back view: Recommended installation clearances (dryer only): Water inlet (Steam Models Only) Vent Gas *Approx. measurement NOTE: Most installations require a minimum of the dryer to reduce noise transfer. Installation spacing for recessed area or closet installation All dimensions show recommended and...
... transfer. ■■ For closet installation with equivalent ventilation openings are required. Back view: Recommended installation clearances (dryer only): Water inlet (Steam Models Only) Vent Gas *Approx. measurement NOTE: Most installations require a minimum of the dryer to reduce noise transfer. Installation spacing for recessed area or closet installation All dimensions show recommended and...
Installation Instructions
Page 9
...CSA International) to do not use with the National Fuel Gas Code, ANSI Z223.1. Failure to connect your dryer. GAS TYPE Natural Gas: This dryer is located on the model/serial rating plate for opening and closing . It is certified by UL for test gauge connection, immediately ...upstream of the dryer. Option 2 (Alternate Method) Approved aluminum or copper tubing: ■■ Must include 1/8" NPT minimum plugged ...
...CSA International) to do not use with the National Fuel Gas Code, ANSI Z223.1. Failure to connect your dryer. GAS TYPE Natural Gas: This dryer is located on the model/serial rating plate for opening and closing . It is certified by UL for test gauge connection, immediately ...upstream of the dryer. Option 2 (Alternate Method) Approved aluminum or copper tubing: ■■ Must include 1/8" NPT minimum plugged ...
Installation Instructions
Page 10
...ft. (305 m) increase in leveling legs Diamond marking Examine leveling legs and locate the diamond marking. Firmly grasp dryer body (not console panel) and gently lay dryer down on the model/serial number plate is required for gas appliances, ANSI Z21.24 or CSA 6.10. use TEFLON® tape.... ■■ This dryer must be disconnected from the floor. Slide the dryer on the pedestal model. DRYER GAS PIPE ■■ The gas pipe that complies with a listed flexible gas connector that comes out ...
...ft. (305 m) increase in leveling legs Diamond marking Examine leveling legs and locate the diamond marking. Firmly grasp dryer body (not console panel) and gently lay dryer down on the model/serial number plate is required for gas appliances, ANSI Z21.24 or CSA 6.10. use TEFLON® tape.... ■■ This dryer must be disconnected from the floor. Slide the dryer on the pedestal model. DRYER GAS PIPE ■■ The gas pipe that complies with a listed flexible gas connector that comes out ...
Installation Instructions
Page 17
... and location. 3. Using a wrench to tighten, connect gas supply to gas pipe. A. MAKE GAS CONNECTION (Gas models only) WARNING 2. Install a shut-off valve 1. A. 3/8" flexible gas connector B. 3/8" dryer gas pipe C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare adapter fitting A combination of propane gas. Non...an approved noncorrosive leak-detection solution. If flexible metal tubing is shown. valve is open when handle is parallel to dryer. If connected to dryer A. Connect gas supply to propane, have a qualified person make sure gas pressure does not exceed 13" (33...
... and location. 3. Using a wrench to tighten, connect gas supply to gas pipe. A. MAKE GAS CONNECTION (Gas models only) WARNING 2. Install a shut-off valve 1. A. 3/8" flexible gas connector B. 3/8" dryer gas pipe C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare adapter fitting A combination of propane gas. Non...an approved noncorrosive leak-detection solution. If flexible metal tubing is shown. valve is open when handle is parallel to dryer. If connected to dryer A. Connect gas supply to propane, have a qualified person make sure gas pressure does not exceed 13" (33...
Installation Instructions
Page 19
... to use vent runs longer than those specified in "Vent System Charts." A. Failure to have the dryer converted. Standard Vent System Chart Number of 90° elbows Type of dryer. ■■ Reduce performance, resulting in death, fire, electrical shock, or serious injury. Exhaust hood...can be securely fastened to a noncombustible portion of mobile home and must be converted to exhaust out the right side, left side (all models except long vent), or through the bottom. A. Bottom exhaust installation Determine vent path: ■■ Select route that will : ■...
... to use vent runs longer than those specified in "Vent System Charts." A. Failure to have the dryer converted. Standard Vent System Chart Number of 90° elbows Type of dryer. ■■ Reduce performance, resulting in death, fire, electrical shock, or serious injury. Exhaust hood...can be securely fastened to a noncombustible portion of mobile home and must be converted to exhaust out the right side, left side (all models except long vent), or through the bottom. A. Bottom exhaust installation Determine vent path: ■■ Select route that will : ■...
Installation Instructions
Page 20
... 150 ft. (45.7 m) 2 Rigid metal 140 ft. (42.7 m) 3 Rigid metal 130 ft. (39.6 m) 4 Rigid metal 120 ft. (36.6 m) To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. Install Vent System 1. A gas... long vent systems, use caulking compound to seal exterior wall opening around exhaust hood. 20 Connect vent to dryer location using straightest path possible. Example: An electric model would be DJAV - Install exhaust hood Install exhaust hood and use of box/louvered hoods will improve venting ...
... 150 ft. (45.7 m) 2 Rigid metal 140 ft. (42.7 m) 3 Rigid metal 130 ft. (39.6 m) 4 Rigid metal 120 ft. (36.6 m) To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. Install Vent System 1. A gas... long vent systems, use caulking compound to seal exterior wall opening around exhaust hood. 20 Connect vent to dryer location using straightest path possible. Example: An electric model would be DJAV - Install exhaust hood Install exhaust hood and use of box/louvered hoods will improve venting ...
Installation Instructions
Page 21
... Damage to cold water faucet. NOTE: Do not overtighten. Damage to "Connect Vent." CONNECT INLET HOSE (STEAM MODEL ONLY) For non-steam models, skip to the coupling can result. 4. Screw on coupling by hand until it is seated on connector. Do ...not use to reduce the risk of the 5 ft. (1.5 m) inlet hose ends to the "Y" connector. Remove old rubber washer from inlet hose and replace with additional 2/3 turn . Tighten couplings 1. The dryer...
... Damage to cold water faucet. NOTE: Do not overtighten. Damage to "Connect Vent." CONNECT INLET HOSE (STEAM MODEL ONLY) For non-steam models, skip to the coupling can result. 4. Screw on coupling by hand until it is seated on connector. Do ...not use to reduce the risk of the 5 ft. (1.5 m) inlet hose ends to the "Y" connector. Remove old rubber washer from inlet hose and replace with additional 2/3 turn . Tighten couplings 1. The dryer...
Installation Instructions
Page 23
... level, make sure all packaging materials. Be sure the water faucets are set in the dryer. All Models: Select a Timed Dry heated cycle and start of its first cycle. If dryer will not start, check the following: • Controls are on. Check for leaks around ... parts of a water softener is not crushed or kinked. Check that all parts are snug against the floor and the dryer does not rock. Electric Models: Plug into an outlet and/or electrical supply is connected. • Household fuse is intact and tight, or circuit...
... level, make sure all packaging materials. Be sure the water faucets are set in the dryer. All Models: Select a Timed Dry heated cycle and start of its first cycle. If dryer will not start, check the following: • Controls are on. Check for leaks around ... parts of a water softener is not crushed or kinked. Check that all parts are snug against the floor and the dryer does not rock. Electric Models: Plug into an outlet and/or electrical supply is connected. • Household fuse is intact and tight, or circuit...
Installation Instructions
Page 24
...) The following instructions are registered trademarks of Acument Intellectual Properties, LLC. 24 Disconnect wiring from the dryer door before proceeding. Tuck wiring into opening. †®TORX, T20, and T25 are for models with the two screws removed earlier, as shown. Using a T25® screwdriver, remove the four... screws securing the door hinge to the dryer and lift the door up and out to the opposite side of dryer door frame with round and square-...
...) The following instructions are registered trademarks of Acument Intellectual Properties, LLC. 24 Disconnect wiring from the dryer door before proceeding. Tuck wiring into opening. †®TORX, T20, and T25 are for models with the two screws removed earlier, as shown. Using a T25® screwdriver, remove the four... screws securing the door hinge to the dryer and lift the door up and out to the opposite side of dryer door frame with round and square-...
Instruction Sheet
Page 1
... Hose Your installation may require additional parts. NOTE: Do not overtighten. Screw on coupling by hand until it is seated on model). C heck that the water faucets are in place. 3. Attach 2' (0.6 m) inlet hose to the cold water faucet using the new ... overtighten. Tools needed: Parts Supplied: Pliers "Y" connector Rubber washer Parts needed: (Not supplied with new rubber washer provided. C heck for Steam Dryers Instrucciones para la conexión de la manguera de entrada para secadoras con vapor Instructions de raccordement du tuyau d'arrivée d'eau pour les ...
... Hose Your installation may require additional parts. NOTE: Do not overtighten. Screw on coupling by hand until it is seated on model). C heck that the water faucets are in place. 3. Attach 2' (0.6 m) inlet hose to the cold water faucet using the new ... overtighten. Tools needed: Parts Supplied: Pliers "Y" connector Rubber washer Parts needed: (Not supplied with new rubber washer provided. C heck for Steam Dryers Instrucciones para la conexión de la manguera de entrada para secadoras con vapor Instructions de raccordement du tuyau d'arrivée d'eau pour les ...