Refer to the solar cycle chart for more details. Manual
Page 1
... is determined by whether the application is not supported in an open area clear of cold weather on batteries in the given regions. LA412 Solar Gate Access System Daily Cycle Chart The LA412 Solar Gate Access System utilizes the innovative EverCharge® Power Management System to deliver power when needed most for more than 2 consecutive weeks during the winter...
... is determined by whether the application is not supported in an open area clear of cold weather on batteries in the given regions. LA412 Solar Gate Access System Daily Cycle Chart The LA412 Solar Gate Access System utilizes the innovative EverCharge® Power Management System to deliver power when needed most for more than 2 consecutive weeks during the winter...
LA412 Manual
Page 7
... LA412 (1) Model LA412-S (2) Gate Bracket Model LA412 (1) Model LA412-S (2) Post Bracket Model LA412 (1) Model LA412-S (2) 12V 10W Solar Panel Model SOLPNL10W12V (1) Cable Ties (4) Standard Control Box (1) with the hardware to install on a gate that pulls-to-open , accessory kit 50-19503 is for vehicles only Pedestrians must use separate entrance Warning Signs (2) Wire Nuts (6) Model LA412 ONLY Watertight Connector Model LA412-S ONLY (2) Gate...
... LA412 (1) Model LA412-S (2) Gate Bracket Model LA412 (1) Model LA412-S (2) Post Bracket Model LA412 (1) Model LA412-S (2) 12V 10W Solar Panel Model SOLPNL10W12V (1) Cable Ties (4) Standard Control Box (1) with the hardware to install on a gate that pulls-to-open , accessory kit 50-19503 is for vehicles only Pedestrians must use separate entrance Warning Signs (2) Wire Nuts (6) Model LA412 ONLY Watertight Connector Model LA412-S ONLY (2) Gate...
LA412 Manual
Page 9
... Hinge Post Bracket Operator Operator Cable Antenna Solar Panel (Facing South) Control Box with Batteries Solar Panel (Facing South) Hinge Post Bracket Gate Bracket PVC Conduit (not provided) to protect the power cable for solar and low voltage wire from lawn mowers and... Operator Cable Earth Ground Installation (Optional) 11gw22aiWrGueiargeuege (8(282.f4f.te4.metm) ) Photoelectric Sensors RIGHT-HAND GATE NOTE: One or more non-contact sensors shall be exercised to reduce the risk of entrapment or obstruction exists at either the opening or closing direction.
... Hinge Post Bracket Operator Operator Cable Antenna Solar Panel (Facing South) Control Box with Batteries Solar Panel (Facing South) Hinge Post Bracket Gate Bracket PVC Conduit (not provided) to protect the power cable for solar and low voltage wire from lawn mowers and... Operator Cable Earth Ground Installation (Optional) 11gw22aiWrGueiargeuege (8(282.f4f.te4.metm) ) Photoelectric Sensors RIGHT-HAND GATE NOTE: One or more non-contact sensors shall be exercised to reduce the risk of entrapment or obstruction exists at either the opening or closing direction.
LA412 Manual
Page 10
....metm) ) Earth Ground Installation (Optional) NOTE: One or more non-contact sensors shall be exercised to protect the power cable for solar and low voltage wire from lawn mowers and string trimmers. Care shall be located where the risk of nuisance tripping, ... DUAL GATE Solar Panel (Facing South) Antenna Warning Sign Hinge Post Bracket Gate Bracket Gate 1 Control Box with Batteries Operator Cable Gate 2 Junction Box Extension Cable Photoelectric Sensors PVC Conduit (not provided) to reduce the risk of entrapment or obstruction exists at either the opening or closing...
....metm) ) Earth Ground Installation (Optional) NOTE: One or more non-contact sensors shall be exercised to protect the power cable for solar and low voltage wire from lawn mowers and string trimmers. Care shall be located where the risk of nuisance tripping, ... DUAL GATE Solar Panel (Facing South) Antenna Warning Sign Hinge Post Bracket Gate Bracket Gate 1 Control Box with Batteries Operator Cable Gate 2 Junction Box Extension Cable Photoelectric Sensors PVC Conduit (not provided) to reduce the risk of entrapment or obstruction exists at either the opening or closing...
LA412 Manual
Page 20
... CHGR OVLD CTRL PWR AC PWR /SOLAR LOOP INPUTS ALARM LOCK SOL GND MAGR GATE 1 BR GR WH YL BL RD ACCESSORY POWER 12 V BR GR WH YL BL RD GATE 2 LEARN XMITTER ON OFF LOCK / BIPA RT DELAY CLOSE EDGE OPEN EDGE/ PHOTO OPEN PHOTO SET OPEN LIMIT GATE 1 CLOSE PHOTO SET CLOSE LIMIT LEARN...INPUTS INTERRUPT CHGR OVLD CTRL PWR AC PWR /SOLAR ALARM LOCK SOL GND MAGR GATE 1 BR GR WH YL BL RD ACCESSORY POWER 12 V BR GR WH YL BL RD GATE 2 LEARN XMITTER ON OFF LOCK / BIPA RT DELAY CLOSE EDGE OPEN EDGE/ PHOTO OPEN PHOTO SET OPEN LIMIT GATE 1 CLOSE PHOTO SET CLOSE LIMIT LEARN LIMITS...
... CHGR OVLD CTRL PWR AC PWR /SOLAR LOOP INPUTS ALARM LOCK SOL GND MAGR GATE 1 BR GR WH YL BL RD ACCESSORY POWER 12 V BR GR WH YL BL RD GATE 2 LEARN XMITTER ON OFF LOCK / BIPA RT DELAY CLOSE EDGE OPEN EDGE/ PHOTO OPEN PHOTO SET OPEN LIMIT GATE 1 CLOSE PHOTO SET CLOSE LIMIT LEARN...INPUTS INTERRUPT CHGR OVLD CTRL PWR AC PWR /SOLAR ALARM LOCK SOL GND MAGR GATE 1 BR GR WH YL BL RD ACCESSORY POWER 12 V BR GR WH YL BL RD GATE 2 LEARN XMITTER ON OFF LOCK / BIPA RT DELAY CLOSE EDGE OPEN EDGE/ PHOTO OPEN PHOTO SET OPEN LIMIT GATE 1 CLOSE PHOTO SET CLOSE LIMIT LEARN LIMITS...
LA412 Manual
Page 26
... solar chart for using a single 10W solar panel in the given regions. Solar panels cannot be installed in areas that reach below -4° F. SOLAR PANEL INSTALLATION » SELECT SITE FOR SOLAR PANEL(S) SELECT SITE FOR SOLAR PANEL(S) The solar panel(s) must be located in an open...increase the number of obstructions and shading for installed accessories that draw additional battery power. NOTE: The solar panel(s) recommendation is based upon the average solar radiation and the temperature effects on gate construction and installation. If required, up to three 10W panels (30W total...
... solar chart for using a single 10W solar panel in the given regions. Solar panels cannot be installed in areas that reach below -4° F. SOLAR PANEL INSTALLATION » SELECT SITE FOR SOLAR PANEL(S) SELECT SITE FOR SOLAR PANEL(S) The solar panel(s) must be located in an open...increase the number of obstructions and shading for installed accessories that draw additional battery power. NOTE: The solar panel(s) recommendation is based upon the average solar radiation and the temperature effects on gate construction and installation. If required, up to three 10W panels (30W total...
LA412 Manual
Page 29
...LOCK / R2 XMITTER BIPART DELAY D1Ø C7Ø C71 C72 C73 18 GATE 1 K1 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS Control Board GATE 2 TIMER RUNNING Q9 24V R9Ø J2Ø F9 GATE 2 BR R1ØØ GR WH YL BL RD R1Ø1 Q22 ...of the control box. SOLAR PANEL INSTALLATION » CONNECT SOLAR PANEL(S) TO OPERATOR CONTROL BOX + CONNECT BATTERIES CONNECT SOLAR PANEL(S) TO OPERATOR CONTROL BOX 1 Open the control box cover. 2 Disconnect all power and batteries from the control board. 3 Run the solar panel cable to secure the solar panel cable away from ...
...LOCK / R2 XMITTER BIPART DELAY D1Ø C7Ø C71 C72 C73 18 GATE 1 K1 SET OPEN LIMIT SET CLOSE LIMIT LEARN LIMITS Control Board GATE 2 TIMER RUNNING Q9 24V R9Ø J2Ø F9 GATE 2 BR R1ØØ GR WH YL BL RD R1Ø1 Q22 ...of the control box. SOLAR PANEL INSTALLATION » CONNECT SOLAR PANEL(S) TO OPERATOR CONTROL BOX + CONNECT BATTERIES CONNECT SOLAR PANEL(S) TO OPERATOR CONTROL BOX 1 Open the control box cover. 2 Disconnect all power and batteries from the control board. 3 Run the solar panel cable to secure the solar panel cable away from ...
LA412 Manual
Page 37
... NOTE: Batteries MUST 8 be connected to operate. Close Photo 6. Accessory Power 11. Gate 1 12. Lock (Solenoid/Maglock) Output 13. Primary Gate Jog 19. Timer To Close 23. Open Edge/Photo 4. Learn Xmitter 18. Force 22. Open Photo 5. Control Inputs 7. Loop Inputs 8. Alarm Output 14. OPTIONAL TRANSFORMER SOLAR PANEL NOTE: 14.5 V output on transformer. Antenna Input 2. Learn...
... NOTE: Batteries MUST 8 be connected to operate. Close Photo 6. Accessory Power 11. Gate 1 12. Lock (Solenoid/Maglock) Output 13. Primary Gate Jog 19. Timer To Close 23. Open Edge/Photo 4. Learn Xmitter 18. Force 22. Open Photo 5. Control Inputs 7. Loop Inputs 8. Alarm Output 14. OPTIONAL TRANSFORMER SOLAR PANEL NOTE: 14.5 V output on transformer. Antenna Input 2. Learn...
LA412 Manual
Page 39
... COMMAND IS GIVEN, BUT THE OPERATOR DOES NOT MOVE OR GATE DISCONNECTED. OPERATOR DOES NOT RESPOND TO REMOTE CONTROL COMMAND. • Power not connected. Press the RESET button and verify that all ...defective battery. Verify the wire connects between the motor housing and arm assembly. GATE DOES NOT FULLY OPEN OR CLOSE WHEN TRYING TO LEARN LIMITS. Press the RESET button and verify ... least one battery is intact. Verify battery fuse is connected with the gate mount bracket. Make sure the AC/Solar input is connected and that both 4-pin connectors. 38 Replace control board...
... COMMAND IS GIVEN, BUT THE OPERATOR DOES NOT MOVE OR GATE DISCONNECTED. OPERATOR DOES NOT RESPOND TO REMOTE CONTROL COMMAND. • Power not connected. Press the RESET button and verify that all ...defective battery. Verify the wire connects between the motor housing and arm assembly. GATE DOES NOT FULLY OPEN OR CLOSE WHEN TRYING TO LEARN LIMITS. Press the RESET button and verify ... least one battery is intact. Verify battery fuse is connected with the gate mount bracket. Make sure the AC/Solar input is connected and that both 4-pin connectors. 38 Replace control board...
LA412 Manual
Page 43
...open gate from outside by entering a 4-digit code on a specially designed keypad. CLOSE 7 AH/12 Vdc Gate Access System Battery: The gate access system battery is easy to the operator system. The model LA412 is for installation with operators utilizing the XLM control box. Up to three Solar...battery in case of reduced sunlight and colder weather. To order visit www.liftmaster.com 42 OPEN CLOSE Can be mounted onto gate or post. Gate Arm Pin Lock: The pin lock kit is closed. ACCESSORIES 373LM OPEN 3-Button SECUCLOSERITY✚® Remote Control: Includes visor clip.
...open gate from outside by entering a 4-digit code on a specially designed keypad. CLOSE 7 AH/12 Vdc Gate Access System Battery: The gate access system battery is easy to the operator system. The model LA412 is for installation with operators utilizing the XLM control box. Up to three Solar...battery in case of reduced sunlight and colder weather. To order visit www.liftmaster.com 42 OPEN CLOSE Can be mounted onto gate or post. Gate Arm Pin Lock: The pin lock kit is closed. ACCESSORIES 373LM OPEN 3-Button SECUCLOSERITY✚® Remote Control: Includes visor clip.