...comply with the warnings that accompany it. Read them . Read the warnings carefully. TABLE OF CONTENTS SAFETY 1 SAFETY SYMBOL AND SIGNAL WORD REVIEW 1 USAGE CLASS 2 UL325 ENTRAPMENT PROTECTION REQUIREMENTS 2 SAFETY INSTALLATION INFORMATION 3 GATE CONSTRUCTION INFORMATION 4 INTRODUCTION 5 CARTON INVENTORY 5 SPECIFICATIONS 6 SITE... 23 ADJUSTMENT 23 LIMIT AND FORCE ADJUSTMENT 23 OBSTRUCTION TEST 25 PROGRAMMING 26 REMOTE CONTROLS (NOT PROVIDED 26 LIFTMASTER INTERNET GATEWAY (NOT PROVIDED 27 ERASE ALL CODES 27 ERASE LIMITS 27 TO REMOVE AND ERASE MONITORED ENTRAPMENT ...
...comply with the warnings that accompany it. Read them . Read the warnings carefully. TABLE OF CONTENTS SAFETY 1 SAFETY SYMBOL AND SIGNAL WORD REVIEW 1 USAGE CLASS 2 UL325 ENTRAPMENT PROTECTION REQUIREMENTS 2 SAFETY INSTALLATION INFORMATION 3 GATE CONSTRUCTION INFORMATION 4 INTRODUCTION 5 CARTON INVENTORY 5 SPECIFICATIONS 6 SITE... 23 ADJUSTMENT 23 LIMIT AND FORCE ADJUSTMENT 23 OBSTRUCTION TEST 25 PROGRAMMING 26 REMOTE CONTROLS (NOT PROVIDED 26 LIFTMASTER INTERNET GATEWAY (NOT PROVIDED 27 ERASE ALL CODES 27 ERASE LIMITS 27 TO REMOVE AND ERASE MONITORED ENTRAPMENT ...
LA400DC Owner's Manual
Page 24
... Panels section in the Appendix, pages 42-46. Replace the junction box cover. Ensure the wires are not pinched. 8. NOTE: All power wiring should be reviewed for suitability of wire installation. 1. Local codes and conditions must be on a dedicated circuit, calculated using a wire nut. 7. Turn ON AC power to your application...
... Panels section in the Appendix, pages 42-46. Replace the junction box cover. Ensure the wires are not pinched. 8. NOTE: All power wiring should be reviewed for suitability of wire installation. 1. Local codes and conditions must be on a dedicated circuit, calculated using a wire nut. 7. Turn ON AC power to your application...
LA400DC Owner's Manual
Page 37
...missing exit loop (SHORT Check loop wiring throughout connection. LiftMaster Plug-in the error code history and some are saved in Loop Detector only) Check loop wiring throughout connection. Review power supply and wiring. Review monitored entrapment protection device connections. check for an obstruction...system. Absolute Position Encoder Error, not getting position information from encoder Check the operator cable connections, then reprogram the limits. LiftMaster Plug-in Loop Detector only) or an open connection in the loop. Rarely, may be at boot up Check battery ...
...missing exit loop (SHORT Check loop wiring throughout connection. LiftMaster Plug-in the error code history and some are saved in Loop Detector only) Check loop wiring throughout connection. Review power supply and wiring. Review monitored entrapment protection device connections. check for an obstruction...system. Absolute Position Encoder Error, not getting position information from encoder Check the operator cable connections, then reprogram the limits. LiftMaster Plug-in Loop Detector only) or an open connection in the loop. Rarely, may be at boot up Check battery ...
LA400DC Owner's Manual
Page 41
...is given a) Change setting of entrapment (obstruction) detection and correct. c) Replace defective expansion board or defective main board 39 a) Review Interrupt loop detector settings. Adjust settings as needed. Alarm beeps when running on batteries and battery voltage must be 23.0 Vdc or...settings as needed . If no AC power, then running on batteries and battery voltage must be 23.0 Vdc or higher. a) Review Shadow loop detector settings. SYMPTOM Gate closes, but will not open. Charge batteries by AC or solar power or replace batteries. ...
...is given a) Change setting of entrapment (obstruction) detection and correct. c) Replace defective expansion board or defective main board 39 a) Review Interrupt loop detector settings. Adjust settings as needed. Alarm beeps when running on batteries and battery voltage must be 23.0 Vdc or...settings as needed . If no AC power, then running on batteries and battery voltage must be 23.0 Vdc or higher. a) Review Shadow loop detector settings. SYMPTOM Gate closes, but will not open. Charge batteries by AC or solar power or replace batteries. ...