Page 11
... Measure resistance of terminal If thermal fuse is opposite to Open condition. Idler switch Measure resistance of the following terminal : "COM - Outlet Thermostat ( Auto reset) • Check Top Marking : N85 4. Measure resistance of terminal to turn the power off, and do voltage discharge ... Thermal cut off • Check Top Marking : N130 2. "NO" (1-2) 2) Door switch push : push Terminal : "COM" - Hi limit Thermostat (Auto reset) 3. Measure resistance of terminal to terminal 80Ω ~ 100Ω • Heater case Hi limit • Electric type •...
... Measure resistance of terminal If thermal fuse is opposite to Open condition. Idler switch Measure resistance of the following terminal : "COM - Outlet Thermostat ( Auto reset) • Check Top Marking : N85 4. Measure resistance of terminal to turn the power off, and do voltage discharge ... Thermal cut off • Check Top Marking : N130 2. "NO" (1-2) 2) Door switch push : push Terminal : "COM" - Hi limit Thermostat (Auto reset) 3. Measure resistance of terminal to terminal 80Ω ~ 100Ω • Heater case Hi limit • Electric type •...
Service Manual
Page 13
Component 13. Outlet Thermostat (Manual reset) • Check Top Marking : N100 Test Procedure Measure resistance of terminal to terminal Open at 203 ± 7°F (95 ± 5°C) Close at ... ± 7°C) Manual reset If thermal fuse is open must be replaced Resistance value ∞ Continuity < 1Ω • Gas type • Gas funnel 12 Outlet Thermostat (Auto reset) • Check Top Marking : N95 13.
Component 13. Outlet Thermostat (Manual reset) • Check Top Marking : N100 Test Procedure Measure resistance of terminal to terminal Open at 203 ± 7°F (95 ± 5°C) Close at ... ± 7°C) Manual reset If thermal fuse is open must be replaced Resistance value ∞ Continuity < 1Ω • Gas type • Gas funnel 12 Outlet Thermostat (Auto reset) • Check Top Marking : N95 13.
Service Manual
Page 17
... Off + Lamp On + Buzzer beeps five times Door switch Lamp See test 6 During check, Motor & Heater Off If the door is open may trip the Thermostat attached to the Heater, therefore do not activate it manually. (Do not press the door switch to operate the heater while the door is closed...
... Off + Lamp On + Buzzer beeps five times Door switch Lamp See test 6 During check, Motor & Heater Off If the door is open may trip the Thermostat attached to the Heater, therefore do not activate it manually. (Do not press the door switch to operate the heater while the door is closed...
Service Manual
Page 20
...YES (Not operating Lever is contacted. 19 NO YES • Replace Control. (Relay check) • Check Controller connector. • Replace Outlet • Thermostat. (Refer to 'Component') • Check Idler Assembly. • Drum Belt cuts off • Drum Belt takes off , and do voltage discharge. (When... discharging, contact the metal plug of Outlet Thermostat attached to blower housing? NO Is resistance below 3Ω between Connector "BL2- No fan will work. Measurement Condition Turn the Dryer's ...
...YES (Not operating Lever is contacted. 19 NO YES • Replace Control. (Relay check) • Check Controller connector. • Replace Outlet • Thermostat. (Refer to 'Component') • Check Idler Assembly. • Drum Belt cuts off • Drum Belt takes off , and do voltage discharge. (When... discharging, contact the metal plug of Outlet Thermostat attached to blower housing? NO Is resistance below 3Ω between Connector "BL2- No fan will work. Measurement Condition Turn the Dryer's ...
Service Manual
Page 23
...NO and at RUN condition. • Check Motor and replace it. Is resistance between terminal TH3 (HI-Limit Thermostat). YES Check if the value of measured resistance is below 1Ω between Heater terminal and below 1Ω between terminal TH2 (Safety... Thermostat). Check Motor. Test 6 Heater switch test - Check if the value of measured resistance is below 9 ~ 11Ω? NO YES • Replace TH3 (HI-Limit Thermostat). NO YES • Replace TH2 (Safety Thermostat). YES Check Controller. Check Harness-linking ...
...NO and at RUN condition. • Check Motor and replace it. Is resistance between terminal TH3 (HI-Limit Thermostat). YES Check if the value of measured resistance is below 1Ω between Heater terminal and below 1Ω between terminal TH2 (Safety... Thermostat). Check Motor. Test 6 Heater switch test - Check if the value of measured resistance is below 9 ~ 11Ω? NO YES • Replace TH3 (HI-Limit Thermostat). NO YES • Replace TH2 (Safety Thermostat). YES Check Controller. Check Harness-linking ...
Service Manual
Page 24
Gas Type Caution When measuring power, be sure to wear insulated gloves, to avoid electric shock. YES NO • Check thermostat Hi limit Safety Igniter operates? (after 1 min, Igniter becomes reddish) YES NO • Check Igniter & Frame detect When measuring Valve 2 voltage, Value is more than1.5 ~ 2....
Gas Type Caution When measuring power, be sure to wear insulated gloves, to avoid electric shock. YES NO • Check thermostat Hi limit Safety Igniter operates? (after 1 min, Igniter becomes reddish) YES NO • Check Igniter & Frame detect When measuring Valve 2 voltage, Value is more than1.5 ~ 2....