Service Manual
Page 15
... do voltage discharge sufficiently. "NC" (1-3) Terminal: "COM" - Lamp holder Test Procedure Check result Remark Measure resistance of terminal If thermal fuse is opposite to terminal 80Ω ~ 100Ω • Heater case Hi limit • Electric type • Blow housing Safety...of terminal to terminal be sure to turn the power off • Check Top Marking: N130 2. "NC" (1-3) Terminal: "COM" - NC" 1. Thermal cut off. Outlet Thermostat ( Auto reset) • Check Top Marking: N85 4. lever open Resistance value < 1Ω 2. CAUTION When checking the Component...
... do voltage discharge sufficiently. "NC" (1-3) Terminal: "COM" - Lamp holder Test Procedure Check result Remark Measure resistance of terminal If thermal fuse is opposite to terminal 80Ω ~ 100Ω • Heater case Hi limit • Electric type • Blow housing Safety...of terminal to terminal be sure to turn the power off • Check Top Marking: N130 2. "NC" (1-3) Terminal: "COM" - NC" 1. Thermal cut off. Outlet Thermostat ( Auto reset) • Check Top Marking: N85 4. lever open Resistance value < 1Ω 2. CAUTION When checking the Component...
Service Manual
Page 17
... resistance of terminal to terminal Open at 203 ± 7°F (95 ± 5°C) Close at 212 ± 12°F (100 ± 7°C) Manual reset If thermal fuse is open must be replaced Resistance value ∞ Continuity < 1Ω • Gas type • Gas funnel 15. Component 13. Outlet Thermostat (Auto reset) Test Procedure...