b) This dryer must be connected to the equipment-grounding terminal or lead on nameplate. or an equipment-grounding conductor must be run with the circuit conductors and connected to a grounded metal, permanent wiring system; ...to disconnection when servicing the dryer, because wiring errors can be moved from its own terminal block that must conform to examples on the following pages. ! e) The power cord (pigtail) connection between wall receptacle and dryer terminal block IS NOT supplied with instructions mentioned on next page. Type of pigtail and gauge of...
b) This dryer must be connected to the equipment-grounding terminal or lead on nameplate. or an equipment-grounding conductor must be run with the circuit conductors and connected to a grounded metal, permanent wiring system; ...to disconnection when servicing the dryer, because wiring errors can be moved from its own terminal block that must conform to examples on the following pages. ! e) The power cord (pigtail) connection between wall receptacle and dryer terminal block IS NOT supplied with instructions mentioned on next page. Type of pigtail and gauge of...
Owners Manual
Page 15
...leaving b(1a2r.7ecgm)round wire at your home. External ground connector b. Peel 5 in (12.7cm) of external covering from end 5" 31/2" of the terminal block(hooked end facing rightward) and pinch the hook together and screw tightly. (12.75c" m) 5" (12.7 cm) 3V2" (8.9 cm) 4 wire direct...wires like a hook. 1" (2.5 cm) (12.75c" m) (8 Then, put the hooked shape end of the wire under center, silver colored terminal block screw. 3.Connect ground wire(green) of power supply cable to determine the appropriate electrical connection for your home: 3-wire receptacle (NEMA type10-30R) ...
...leaving b(1a2r.7ecgm)round wire at your home. External ground connector b. Peel 5 in (12.7cm) of external covering from end 5" 31/2" of the terminal block(hooked end facing rightward) and pinch the hook together and screw tightly. (12.75c" m) 5" (12.7 cm) 3V2" (8.9 cm) 4 wire direct...wires like a hook. 1" (2.5 cm) (12.75c" m) (8 Then, put the hooked shape end of the wire under center, silver colored terminal block screw. 3.Connect ground wire(green) of power supply cable to determine the appropriate electrical connection for your home: 3-wire receptacle (NEMA type10-30R) ...
Owners Manual
Page 16
... dryer rear panel. External ground connector b. Part 4 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS 4. Tighten strain relief screws. 7. Place the tab of terminal block cover into slot of terminal block. 4. Shape ends of wires into a hook shape. 1" (2.5 cm) 1" (2.5 cm) (12.75c" m) 3V2" (8.9 cm) ...Then, put the hooked shape end of the wire under the center screw of 3-wire connections. Center silver-colored terminal block screw d. Squeeze the hooked end together 3. Make sure cover with screw. At least, 5ft(1.52m) of extra length is needed are mobile ...
... dryer rear panel. External ground connector b. Part 4 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS 4. Tighten strain relief screws. 7. Place the tab of terminal block cover into slot of terminal block. 4. Shape ends of wires into a hook shape. 1" (2.5 cm) 1" (2.5 cm) (12.75c" m) 3V2" (8.9 cm) ...Then, put the hooked shape end of the wire under the center screw of 3-wire connections. Center silver-colored terminal block screw d. Squeeze the hooked end together 3. Make sure cover with screw. At least, 5ft(1.52m) of extra length is needed are mobile ...
Owners Manual
Page 17
... to the neutral wire, use the instructions under Section 3: Optional 3-wire connection. Center silver-colored terminal block screw d. Tighten strain relief screws. 5. Tighten screw. Neutral grounding wire (white) c. Tighten screws. 4. Insert tab of terminal block cover into slot of the terminal block. a d gf a. 3-wire receptacle (NEMA type 10-30R) b. 3-wire plug c. Neutral wire (white or center...
... to the neutral wire, use the instructions under Section 3: Optional 3-wire connection. Center silver-colored terminal block screw d. Tighten strain relief screws. 5. Tighten screw. Neutral grounding wire (white) c. Tighten screws. 4. Insert tab of terminal block cover into slot of the terminal block. a d gf a. 3-wire receptacle (NEMA type 10-30R) b. 3-wire plug c. Neutral wire (white or center...
Owners Manual
Page 18
... b. Tighten strain relief screws. 7. Neutral Prong e. Dotted line shows position of NEUTRAL ground wire before being moved to the center, silver colored terminal screw of power supply cable to outer terminal block screws. White wire of a 3 wire connection, or you are installing e your dryer in a mobile home, you must use a 4wire connection. Center...
... b. Tighten strain relief screws. 7. Neutral Prong e. Dotted line shows position of NEUTRAL ground wire before being moved to the center, silver colored terminal screw of power supply cable to outer terminal block screws. White wire of a 3 wire connection, or you are installing e your dryer in a mobile home, you must use a 4wire connection. Center...
Owners Manual
Page 19
...wire (white or center wire) d. Connect a separate copper ground wire from external ground connector screw. Tighten screws. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. 6. Tighten screw. 3. Grounding path determined by a ...qualified electrician 4. Tighten strain relief screws. 5. Neutral grounding wire (white) c. Connect the other wires to outer terminal block screws. External ground connector b. Remove appliance neutral ground wire (white) from the external ground connector screw to an adequate ground...
...wire (white or center wire) d. Connect a separate copper ground wire from external ground connector screw. Tighten screws. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. 6. Tighten screw. 3. Grounding path determined by a ...qualified electrician 4. Tighten strain relief screws. 5. Neutral grounding wire (white) c. Connect the other wires to outer terminal block screws. External ground connector b. Remove appliance neutral ground wire (white) from the external ground connector screw to an adequate ground...