Service Manual
Page 23
..., contact the metal plug of measured resistance is below 9 ~ 11Ω? Check if the value of Power cord with earth line.) Trouble Symptom While operating, Heating will not work. NO • Replace Heater. NO YES • Replace TH3 (HI-Limit Thermostat). Is resistance between Heater terminal and below 1Ω between terminal...
..., contact the metal plug of measured resistance is below 9 ~ 11Ω? Check if the value of Power cord with earth line.) Trouble Symptom While operating, Heating will not work. NO • Replace Heater. NO YES • Replace TH3 (HI-Limit Thermostat). Is resistance between Heater terminal and below 1Ω between terminal...
Service Manual
Page 24
..., Igniter becomes reddish) YES NO • Check Igniter & Frame detect When measuring Valve 2 voltage, Value is more than AC 90V? Trouble Symptom While operating, Heating will not work. Drying time takes longer. YES NO • Check thermostat Hi limit Safety Igniter operates? (after Off ) YES • Change Valve NO • Harness check...
..., Igniter becomes reddish) YES NO • Check Igniter & Frame detect When measuring Valve 2 voltage, Value is more than AC 90V? Trouble Symptom While operating, Heating will not work. Drying time takes longer. YES NO • Check thermostat Hi limit Safety Igniter operates? (after Off ) YES • Change Valve NO • Harness check...