Software User Guide for Windows*
Page 10
...; Server Board S2600CO Intel® Server Board S2400SC Intel® Server Board S2400EP Intel® Server Board S2600WP Intel® Server Board S2400LP Intel® Server Board S1600JP Intel® Server Board S2400BB Intel® Server Board S2400GP Intel® Server Board S2600CP Intel® Server Board S2600GZ/GL Intel® Server Board S2600IP Intel® Server Board S2600JF Intel® Workstation Board W2600CR 1.2 Supported Operating Systems Intel® provides drivers for...
...; Server Board S2600CO Intel® Server Board S2400SC Intel® Server Board S2400EP Intel® Server Board S2600WP Intel® Server Board S2400LP Intel® Server Board S1600JP Intel® Server Board S2400BB Intel® Server Board S2400GP Intel® Server Board S2600CP Intel® Server Board S2600GZ/GL Intel® Server Board S2600IP Intel® Server Board S2600JF Intel® Workstation Board W2600CR 1.2 Supported Operating Systems Intel® provides drivers for...
Software User Guide for Windows*
Page 36
...; C600 series chipset based server boards, and driver update after the operating system is installed. 4.1 Installing Microsoft Windows* The following is assumed: Intel® RSTe is enabled in the Intel® Server Board BIOS SETUP. The optical disk drive is discussed in Intel® RSTe RAID mode is attached to the Intel® Server Board. For this example, the...
...; C600 series chipset based server boards, and driver update after the operating system is installed. 4.1 Installing Microsoft Windows* The following is assumed: Intel® RSTe is enabled in the Intel® Server Board BIOS SETUP. The optical disk drive is discussed in Intel® RSTe RAID mode is attached to the Intel® Server Board. For this example, the...
Technical Product Specification
Page 49
...RAID C600 Upgrade key. AHCI requires appropriate software support (for example, an AHCI driver) and for some elements). 3.3.4 Serial Attached SCSI (SAS)/SATA (SCU) Controller The Intel® C600-A Chipset supports up to support 4 of performance features. Please ...4-7 is provided to allow multiple RAID levels to 3.0 Gb/s. Matrix RAID support is disabled. Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture The Intel® C600-A Chipset chipset supports the Serial ATA Specification, Revision 3.0. Table 7. Other RAID features...
...RAID C600 Upgrade key. AHCI requires appropriate software support (for example, an AHCI driver) and for some elements). 3.3.4 Serial Attached SCSI (SAS)/SATA (SCU) Controller The Intel® C600-A Chipset supports up to support 4 of performance features. Please ...4-7 is provided to allow multiple RAID levels to 3.0 Gb/s. Matrix RAID support is disabled. Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture The Intel® C600-A Chipset chipset supports the Serial ATA Specification, Revision 3.0. Table 7. Other RAID features...
Technical Product Specification
Page 53
..., DOS CLI, and EFI CLI Uses Matrix Storage Manager for the Intel® Server Board S2600IP and Intel® Workstation Board W2600CR are PCI Express* Gen3 with appropriate Intel® RAID C600 Upgrade Key Maximum drive support = 8 Open Source Compliance = Binary Driver (includes Partial Source files) or Open Source using MDRAID layer in Linux* (does...
..., DOS CLI, and EFI CLI Uses Matrix Storage Manager for the Intel® Server Board S2600IP and Intel® Workstation Board W2600CR are PCI Express* Gen3 with appropriate Intel® RAID C600 Upgrade Key Maximum drive support = 8 Open Source Compliance = Binary Driver (includes Partial Source files) or Open Source using MDRAID layer in Linux* (does...
Technical Product Specification
Page 94
... drive or else an ISO image file; The actual algorithm that is used is negotiated with the client based on a bare metal server (no OS present) using the remotely mounted device. USB storage devices will require the session to be either a local Floppy drive,...61607; The mounted device shows up in standby mode). Platform Management OverviewIntel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Media redirection supports redirection for the installation of device drivers during system boot, both the virtual IDE and virtual floppy are presented as floppy...
... drive or else an ISO image file; The actual algorithm that is used is negotiated with the client based on a bare metal server (no OS present) using the remotely mounted device. USB storage devices will require the session to be either a local Floppy drive,...61607; The mounted device shows up in standby mode). Platform Management OverviewIntel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Media redirection supports redirection for the installation of device drivers during system boot, both the virtual IDE and virtual floppy are presented as floppy...
Technical Product Specification
Page 172
Appendix D: POST Code Diagnostic LED Decoder Intel® Server Board S2600IP and Intel® Workstation Board W Diagnostic LED Decoder 1 = LED On, 0 = LED Off Checkpoint Upper Nibble Lower Nibble MSB LSB LED # 8h ...1 0 0 1 0 DXE SB devices Init 78h 0 1 1 1 1 0 0 0 DXE ACPI Init 79h 0 1 1 1 1 0 0 1 DXE CSM Init 90h 1 0 0 1 0 0 0 0 DXE BDS Started 91h 1 0 0 1 0 0 0 1 DXE BDS connect drivers 92h 1 0 0 1 0 0 1 0 DXE PCI Bus begin 93h 1 0 0 1 0 0 1 1 DXE PCI Bus HPC Init 94h 1 0 0 1 0 1 0 0 DXE PCI Bus enumeration 95h 1 0 0 1 0 1 0 1 DXE PCI Bus resource requested 96h 1 ...
Appendix D: POST Code Diagnostic LED Decoder Intel® Server Board S2600IP and Intel® Workstation Board W Diagnostic LED Decoder 1 = LED On, 0 = LED Off Checkpoint Upper Nibble Lower Nibble MSB LSB LED # 8h ...1 0 0 1 0 DXE SB devices Init 78h 0 1 1 1 1 0 0 0 DXE ACPI Init 79h 0 1 1 1 1 0 0 1 DXE CSM Init 90h 1 0 0 1 0 0 0 0 DXE BDS Started 91h 1 0 0 1 0 0 0 1 DXE BDS connect drivers 92h 1 0 0 1 0 0 1 0 DXE PCI Bus begin 93h 1 0 0 1 0 0 1 1 DXE PCI Bus HPC Init 94h 1 0 0 1 0 1 0 0 DXE PCI Bus enumeration 95h 1 0 0 1 0 1 0 1 DXE PCI Bus resource requested 96h 1 ...
Technical Product Specification
Page 181
... driver: Not enough memory available to inform users on the POST Progress LEDs Table 86. Recovery boot has been initiated BIOS recovery has failed. The Integrated BMC may generate beep codes upon detection of system security. Codes that are common across all Intel server boards ...resource conflict error TPM device not detected. TPM device failure. System halted because a fatal error related to the digit. Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix E: POST Error Messages and Han Error Code 85ED 85EE 85EF 8604 8605 8606 92A3 92A9 A000 A001 ...
... driver: Not enough memory available to inform users on the POST Progress LEDs Table 86. Recovery boot has been initiated BIOS recovery has failed. The Integrated BMC may generate beep codes upon detection of system security. Codes that are common across all Intel server boards ...resource conflict error TPM device not detected. TPM device failure. System halted because a fatal error related to the digit. Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix E: POST Error Messages and Han Error Code 85ED 85EE 85EF 8604 8605 8606 92A3 92A9 A000 A001 ...
Technical Product Specification
Page 15
...shield, 5.25'' bay filler Pre-routing cables Two heat sinks Your Intel® Server System P4308IP4LHKC ships with the following items: One Intel® Server Board S2600IP Two CRPS 1600W power supply, installed in the chassis Five hot-... power supply Revision 1.0 Intel order number G38159-001 3 Intel® Server System P4000IP Hot-Swap 3.5 HDDs and Non-HDD configuration base feature Feature Dimensions Hard Drives P4308IP4LHGC 438mm high 173mm wide 697mm deep 8*3.5 hot-swap driver cage P4308IP4LHJC (L) P4308IP4LHKC...
...shield, 5.25'' bay filler Pre-routing cables Two heat sinks Your Intel® Server System P4308IP4LHKC ships with the following items: One Intel® Server Board S2600IP Two CRPS 1600W power supply, installed in the chassis Five hot-... power supply Revision 1.0 Intel order number G38159-001 3 Intel® Server System P4000IP Hot-Swap 3.5 HDDs and Non-HDD configuration base feature Feature Dimensions Hard Drives P4308IP4LHGC 438mm high 173mm wide 697mm deep 8*3.5 hot-swap driver cage P4308IP4LHJC (L) P4308IP4LHKC...
Technical Product Specification
Page 32
... access cover can be used to prevent access to the server board and System Service Guide for each specific supported platform. Intel® Server System P4000IP and Intel® Workstation System P4000CR Family TPS Intel® Server System P4000IP and Intel® Workstation System Overview 1.5 Hot swap Hard Drivers and front panel options Figure 13. A variety of lock sizes...
... access cover can be used to prevent access to the server board and System Service Guide for each specific supported platform. Intel® Server System P4000IP and Intel® Workstation System P4000CR Family TPS Intel® Server System P4000IP and Intel® Workstation System Overview 1.5 Hot swap Hard Drivers and front panel options Figure 13. A variety of lock sizes...
Technical Product Specification
Page 6
...Hard Drive Bay - 8 Drive Configuration 45 Figure 32. 3.5" Hard Drive Bay - 12 Drive Configuration 45 Figure 33. 3.5" Hard driver installation 45 Figure 34. 3.5" Drive Hot-Swap Backplane Overview 46 Figure 35. 3.5" Hard Drive Backplane backside 47 Figure 36. DIMM...Bay - 16 Drive Configuration 7 Figure 7. 2.5" Hard Drive Bay - 24 Drive Configuration 7 Figure 8. Intel® Server Board S2600IP 9 Figure 11. Power Distribution Board Interface Connector Pin-out on Interface Board 15 Figure 18. Turn On/Off Timing Diagram (Power Supply Signals 27 Figure 22. System Fan Assembly ...
...Hard Drive Bay - 8 Drive Configuration 45 Figure 32. 3.5" Hard Drive Bay - 12 Drive Configuration 45 Figure 33. 3.5" Hard driver installation 45 Figure 34. 3.5" Drive Hot-Swap Backplane Overview 46 Figure 35. 3.5" Hard Drive Backplane backside 47 Figure 36. DIMM...Bay - 16 Drive Configuration 7 Figure 7. 2.5" Hard Drive Bay - 24 Drive Configuration 7 Figure 8. Intel® Server Board S2600IP 9 Figure 11. Power Distribution Board Interface Connector Pin-out on Interface Board 15 Figure 18. Turn On/Off Timing Diagram (Power Supply Signals 27 Figure 22. System Fan Assembly ...
Technical Product Specification
Page 58
...connector labeled "eUSB SSD" near the rear I/O section of the server board is designed to support SAS Expander cards for storage configurations that utilize a drive bay supporting twelve 3.5" hard disk drives, a 24-Port PCIe Intel® RAID Expander Card RES2SV240 may be installed into . Table...slot. Technical Specifications are as follows: 48 Revision 1.0 Opitcal driver support 5.4 eUSB SSD Suport The system provides support for given hard disk drive configurations. The following table outlines the different Intel SAS Expander options available and which one to plug this small...
...connector labeled "eUSB SSD" near the rear I/O section of the server board is designed to support SAS Expander cards for storage configurations that utilize a drive bay supporting twelve 3.5" hard disk drives, a 24-Port PCIe Intel® RAID Expander Card RES2SV240 may be installed into . Table...slot. Technical Specifications are as follows: 48 Revision 1.0 Opitcal driver support 5.4 eUSB SSD Suport The system provides support for given hard disk drive configurations. The following table outlines the different Intel SAS Expander options available and which one to plug this small...
Specification update
Page 3
...mode 4 2. Hard drives connected through SAS expander can 't be seen in UEFI OS on -board video although install add-in RSTe mode of the SCU controller 9 17. Microsoft Windows 2003* ...assert/deassert log when having blank HDD carriers or un-configured HDDs 7 12. Intel® LAN driver installation failure on SCU ports may fail if there are not supported using OFU utility...in video card 11 Documentation Changes ...13 III System may occur when installing or running Microsoft Windows Server 2008* R2 or Microsoft Windows 7* with SP2 9 16. The BIOS and ME Firmware can...
...mode 4 2. Hard drives connected through SAS expander can 't be seen in UEFI OS on -board video although install add-in RSTe mode of the SCU controller 9 17. Microsoft Windows 2003* ...assert/deassert log when having blank HDD carriers or un-configured HDDs 7 12. Intel® LAN driver installation failure on SCU ports may fail if there are not supported using OFU utility...in video card 11 Documentation Changes ...13 III System may occur when installing or running Microsoft Windows Server 2008* R2 or Microsoft Windows 7* with SP2 9 16. The BIOS and ME Firmware can...
Specification update
Page 8
...used on SCU ports may fail under RSTe RAID mode Problem System may be able to install UEFI Windows Server 2008* R2 SP1 on Intel® C600 Series Chipset based Server Boards under UEFI with the above mentioned configuration. RSTe RAID mode is installed and SAS HDDs are used . ... using the ESRT2 mode Problem UEFI OS installation of Windows*, Red Hat* Linux or SUSE* Linux may not be fixed in a future driver or BIOS release. Monthly Specification Update Enterprise Platforms and Services Marketing Errata 1. Status This issue may not be fixed in a future BIOS release...
...used on SCU ports may fail under RSTe RAID mode Problem System may be able to install UEFI Windows Server 2008* R2 SP1 on Intel® C600 Series Chipset based Server Boards under UEFI with the above mentioned configuration. RSTe RAID mode is installed and SAS HDDs are used . ... using the ESRT2 mode Problem UEFI OS installation of Windows*, Red Hat* Linux or SUSE* Linux may not be fixed in a future driver or BIOS release. Monthly Specification Update Enterprise Platforms and Services Marketing Errata 1. Status This issue may not be fixed in a future BIOS release...
Specification update
Page 9
... may not be able to install RSTe GUI under mentioned configuration when the AHCI controller is to either plug a SATA device into one of RSTe drivers and the Graphic User Interface (GUI) in BIOS 6. Enterprise Platforms and Services Marketing Monthly Specification Update Implication Status Workaround User may not be able ...message. None. 4. Workaround The workaround is enabled and no devices attached to any onboard AHCI ports Problem When Microsoft Windows 2008* R2 is installed on Intel® C600 Series Chipset based Server Boards This issue may be fixed in a future RAID driver.
... may not be able to install RSTe GUI under mentioned configuration when the AHCI controller is to either plug a SATA device into one of RSTe drivers and the Graphic User Interface (GUI) in BIOS 6. Enterprise Platforms and Services Marketing Monthly Specification Update Implication Status Workaround User may not be able ...message. None. 4. Workaround The workaround is enabled and no devices attached to any onboard AHCI ports Problem When Microsoft Windows 2008* R2 is installed on Intel® C600 Series Chipset based Server Boards This issue may be fixed in a future RAID driver.
Service Guide
Page 8
... : http://www.intel.com/support. Hardware (peripheral boards, adapter cards, and so on) and operating systems tested with eight 3.5 HDD carrier, installed in the chassis Front panel, installed in the following accessory items for your server: Processors...Installation User Guide Spares and Configuration Guide Intel® Server Configurator tool Tested Hardware and Operating System List Power Budget Analysis Tool Intel Server Management Software Firmware and Drivers viii Intel® Server System P4000IP and Intel® Workstation System P4000CR Service Guide Preface...
... : http://www.intel.com/support. Hardware (peripheral boards, adapter cards, and so on) and operating systems tested with eight 3.5 HDD carrier, installed in the chassis Front panel, installed in the following accessory items for your server: Processors...Installation User Guide Spares and Configuration Guide Intel® Server Configurator tool Tested Hardware and Operating System List Power Budget Analysis Tool Intel Server Management Software Firmware and Drivers viii Intel® Server System P4000IP and Intel® Workstation System P4000CR Service Guide Preface...
Service Guide
Page 13
...Processor - Latch the Locking Lever 29 Figure 33. Cable connections for 24 x 2.5 Hot Swap Hard drivers configuration 21 Figure 20. Cable connections for 8x 3.5 Hot Swap Hard drivers configuration 18 Figure 17. Installing the Airduct 26 Figure 26. Installing DVD or CD-ROM Drive 36 Figure... Figure 44. Removing the Fixed HDD EMI Shield 38 Figure 46. Front Closed Chassis View of Intel® Server System P4224IP4LHKC 8 Figure 7. Removing fixed system fan from the server board 32 Figure 36. Re-inserting Empty EMI Shield 37 Figure 45. Internal Chassis View of Hot-...
...Processor - Latch the Locking Lever 29 Figure 33. Cable connections for 24 x 2.5 Hot Swap Hard drivers configuration 21 Figure 20. Cable connections for 8x 3.5 Hot Swap Hard drivers configuration 18 Figure 17. Installing the Airduct 26 Figure 26. Installing DVD or CD-ROM Drive 36 Figure... Figure 44. Removing the Fixed HDD EMI Shield 38 Figure 46. Front Closed Chassis View of Intel® Server System P4224IP4LHKC 8 Figure 7. Removing fixed system fan from the server board 32 Figure 36. Re-inserting Empty EMI Shield 37 Figure 45. Internal Chassis View of Hot-...
Service Guide
Page 20
... Intel® Server System P4208IP4LHGC Intel® Server System P4308IP4LHJCL Intel® Server System P4308IP4LHJC Intel® Server System P4308IP4LHGC Intel® Server System P4224IP4LHKC Intel® Server System P4216IP4LHKC Intel® Server System P4308IP4LHKC Configuration Intel® Server Board Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Table 2. Server...
... Intel® Server System P4208IP4LHGC Intel® Server System P4308IP4LHJCL Intel® Server System P4308IP4LHJC Intel® Server System P4308IP4LHGC Intel® Server System P4224IP4LHKC Intel® Server System P4216IP4LHKC Intel® Server System P4308IP4LHKC Configuration Intel® Server Board Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Intel® Server board S2600IP Table 2. Server...
Service Guide
Page 225
..., drivers and utilities. Product documentation, installation and quick start guides. Full product specifications, technical advisories and errata. Compatibility documentation for product information throughout the su.pport site. 2. Intel also offers Channel Program members around-the-clock 24x7 technical phone support on Intel® server boards, server chassis, server RAID controller cards, and Intel® Server Management...
..., drivers and utilities. Product documentation, installation and quick start guides. Full product specifications, technical advisories and errata. Compatibility documentation for product information throughout the su.pport site. 2. Intel also offers Channel Program members around-the-clock 24x7 technical phone support on Intel® server boards, server chassis, server RAID controller cards, and Intel® Server Management...
Service Guide
Page 5
... of this Document or Software Intel® Server System R2000IP Product Family Technical Product Specification Intel® Server Board S2600IP Technical Product Specification Intel® Server System R2000IP Product Family Quick Installation User's Guide Spares and Accessories List and Configuration Guide Intel® Server Configurator tool http://serverconfigurator.intel.com Power Budget Tool Intel® Server Deployment & Management DVD Intel Server Products - The back of...
... of this Document or Software Intel® Server System R2000IP Product Family Technical Product Specification Intel® Server Board S2600IP Technical Product Specification Intel® Server System R2000IP Product Family Quick Installation User's Guide Spares and Accessories List and Configuration Guide Intel® Server Configurator tool http://serverconfigurator.intel.com Power Budget Tool Intel® Server Deployment & Management DVD Intel Server Products - The back of...
Service Guide
Page 187
... technical support information on Intel® server boards, server chassis, server RAID controller cards, and Intel® Server Management at http://www.intel.com/support/feedback.htm?group=server (charges may apply). Appendix C: Getting Help Appendix C: Getting Help If you need to log in cards, chassis support matrix and operating systems - Latest BIOS, firmware, drivers and utilities - Server and chassis accessory...
... technical support information on Intel® server boards, server chassis, server RAID controller cards, and Intel® Server Management at http://www.intel.com/support/feedback.htm?group=server (charges may apply). Appendix C: Getting Help Appendix C: Getting Help If you need to log in cards, chassis support matrix and operating systems - Latest BIOS, firmware, drivers and utilities - Server and chassis accessory...