Technical Product Specification
Page 5
...94 6.3.6 Internal Type- Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Table of Contents 4.5.2 User Model...65 4.5.3 LAN Interface ...66 4.6 BMC Firmware Update 76 4.6.1 The BMC firmware release Number 76 4.6.2 Boot Recovery Mode 76 4.6.3 Force...4.9 EU Lot 6 Mode ...82 5. System Security...84 5.1 BIOS Password Protection 84 5.2 Trusted Platform Module (TPM) Support 85 5.2.1 TPM security BIOS 85 5.2.2 Physical Presence 86 5.2.3 TPM Security Setup Options 86 5.3 Intel® Trusted Execution Technology 88 6. A USB Connector 94 6.3.7...
...94 6.3.6 Internal Type- Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Table of Contents 4.5.2 User Model...65 4.5.3 LAN Interface ...66 4.6 BMC Firmware Update 76 4.6.1 The BMC firmware release Number 76 4.6.2 Boot Recovery Mode 76 4.6.3 Force...4.9 EU Lot 6 Mode ...82 5. System Security...84 5.1 BIOS Password Protection 84 5.2 Trusted Platform Module (TPM) Support 85 5.2.1 TPM security BIOS 85 5.2.2 Physical Presence 86 5.2.3 TPM Security Setup Options 86 5.3 Intel® Trusted Execution Technology 88 6. A USB Connector 94 6.3.7...
Technical Product Specification
Page 6
... B Connector 98 Video Connector (For Intel® Server Board S2600IP only 98 Internal Video header (For Intel® Workstation Board W2600CR only 99 7. Jumper Blocks...100 7.1 BIOS Default and Password Reset Usage Procedure 101 7.1.1 Set BIOS to default (Clearing the CMOS 101 7.1.2 Clearing the Password 101 7.2 Force BMC Update Procedure 102 7.3 BIOS Recovery Jumper 102 7.4 ME Force...
... B Connector 98 Video Connector (For Intel® Server Board S2600IP only 98 Internal Video header (For Intel® Workstation Board W2600CR only 99 7. Jumper Blocks...100 7.1 BIOS Default and Password Reset Usage Procedure 101 7.1.1 Set BIOS to default (Clearing the CMOS 101 7.1.2 Clearing the Password 101 7.2 Force BMC Update Procedure 102 7.3 BIOS Recovery Jumper 102 7.4 ME Force...
Technical Product Specification
Page 95
... a single operational image with a limited-functionality recovery image. The recovery image only provides the basic functionality that the system is only supported by a complementary architecture utilizing the ME, BMC, BIOS, and an ACPI-compliant OS. Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSPlatform Management Overview 4.8 Intel® Intelligent Power Node Manager (NM) 4.8.1 Overview...
... a single operational image with a limited-functionality recovery image. The recovery image only provides the basic functionality that the system is only supported by a complementary architecture utilizing the ME, BMC, BIOS, and an ACPI-compliant OS. Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSPlatform Management Overview 4.8 Intel® Intelligent Power Node Manager (NM) 4.8.1 Overview...
Technical Product Specification
Page 114
...Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS 7. The following symbol identifies Pin 1 on each jumper block on the silkscreen: ▼ Figure 28. These pins should not be connected for normal system operation. (Default) The main system BIOS does not boot with a recovery BIOS... features of the server boards. Disabled (Default) 100 Revision 1.1 Intel order number G34153-003 Server Board Jumpers (J1C3, J1F1, J1F2, J2F3, J2F2) Jumper Name J1F2: BIOS Recovery Pins 1-2 2-3 1-2 J1F1: Bios Default (CMOS Clear) 2-3 J2F2: ME Force 1-2 System Results ...
...Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS 7. The following symbol identifies Pin 1 on each jumper block on the silkscreen: ▼ Figure 28. These pins should not be connected for normal system operation. (Default) The main system BIOS does not boot with a recovery BIOS... features of the server boards. Disabled (Default) 100 Revision 1.1 Intel order number G34153-003 Server Board Jumpers (J1C3, J1F1, J1F2, J2F3, J2F2) Jumper Name J1F2: BIOS Recovery Pins 1-2 2-3 1-2 J1F1: Bios Default (CMOS Clear) 2-3 J2F2: ME Force 1-2 System Results ...
Technical Product Specification
Page 115
... and user passwords, power on . The following procedure outlines the new usage model. 7.1.1 Set BIOS to the password clear position (covering pins 2 and 3). 4. Move the jumper from previous generation Intel® boards. Wait five seconds. 5. The CMOS is cleared. Close the server chassis. 5....operation. 7.1 BIOS Default and Password Reset Usage Procedure The BIOS Default (CMOS Clear) and Password Reset recovery features are designed to check if the password is now cleared and you can reset it by going into the BIOS setup. Intel® Server Board S2600IP and Intel® ...
... and user passwords, power on . The following procedure outlines the new usage model. 7.1.1 Set BIOS to the password clear position (covering pins 2 and 3). 4. Move the jumper from previous generation Intel® boards. Wait five seconds. 5. The CMOS is cleared. Close the server chassis. 5....operation. 7.1 BIOS Default and Password Reset Usage Procedure The BIOS Default (CMOS Clear) and Password Reset recovery features are designed to check if the password is now cleared and you can reset it by going into the BIOS setup. Intel® Server Board S2600IP and Intel® ...
Technical Product Specification
Page 116
...remain in this jumper setting when the standard firmware update process fails. Open the server chassis. 9. Jumper Blocks Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS 6. Note: When the Force BMC Update jumper is disabled. You should only ...operating position (covering pins 1 and 2) to the recovery state. 102 Revision 1.1 Intel order number G34153-003 In the event the standard BMC firmware update process fails, complete the following procedure boots the recovery BIOS and flashes the normal BIOS: 1. Move the jumper from the enabled position ...
...remain in this jumper setting when the standard firmware update process fails. Open the server chassis. 9. Jumper Blocks Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS 6. Note: When the Force BMC Update jumper is disabled. You should only ...operating position (covering pins 1 and 2) to the recovery state. 102 Revision 1.1 Intel order number G34153-003 In the event the standard BMC firmware update process fails, complete the following procedure boots the recovery BIOS and flashes the normal BIOS: 1. Move the jumper from the enabled position ...
Technical Product Specification
Page 117
... position. 4. The user should now boot using the updated system BIOS. 7.4 ME Force Update Jumper When performing the standard ME force update procedure, the update utility places the ME into the proper update state. Remove the recovery media. 2. Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Jumper Blocks 3. When the flash...
... position. 4. The user should now boot using the updated system BIOS. 7.4 ME Force Update Jumper When performing the standard ME force update procedure, the update utility places the ME into the proper update state. Remove the recovery media. 2. Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Jumper Blocks 3. When the flash...
Technical Product Specification
Page 135
... the hang. This server board only supports registered DDR3 DIMMs (RDIMMs) and unbuffered DDR3 DIMMs (UDIMMs). Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSAppendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips When adding ...of RDIMMs and UDIMMs is running normally. When performing a normal BIOS update procedure, the BIOS recovery jumper must be balanced across both processor sockets and memory channels. Revision 1.1 121 Intel order number G34153-003 If the server board hangs during the boot process. ...
... the hang. This server board only supports registered DDR3 DIMMs (RDIMMs) and unbuffered DDR3 DIMMs (UDIMMs). Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSAppendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips When adding ...of RDIMMs and UDIMMs is running normally. When performing a normal BIOS update procedure, the BIOS recovery jumper must be balanced across both processor sockets and memory channels. Revision 1.1 121 Intel order number G34153-003 If the server board hangs during the boot process. ...
Technical Product Specification
Page 173
...1 0 1 0 1 Program registers on the channel level Revision 1.1 159 Intel order number G34153-003 Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSAppendix D: POST Code Diagnostic LED Dec Diagnostic LED Decoder... Resume PEIM (S3 OS wake) BIOS Recovery F0h 1 1 1 1 0 0 0 0 PEIM which detected forced Recovery condition F1h 1 1 1 1 0 0 0 1 PEIM which detected User Recovery condition F2h 1 1 1 1 0 0 1 0 Recovery PEIM (Recovery started) F3h 1 1 1 1 0 0 1 1 Recovery PEIM (Capsule found) F4h 1 1 1 1 0 1 0 0 Recovery PEIM (Capsule loaded) POST Memory ...
...1 0 1 0 1 Program registers on the channel level Revision 1.1 159 Intel order number G34153-003 Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSAppendix D: POST Code Diagnostic LED Dec Diagnostic LED Decoder... Resume PEIM (S3 OS wake) BIOS Recovery F0h 1 1 1 1 0 0 0 0 PEIM which detected forced Recovery condition F1h 1 1 1 1 0 0 0 1 PEIM which detected User Recovery condition F2h 1 1 1 1 0 0 1 0 Recovery PEIM (Recovery started) F3h 1 1 1 1 0 0 1 1 Recovery PEIM (Capsule found) F4h 1 1 1 1 0 1 0 0 Recovery PEIM (Capsule loaded) POST Memory ...
Technical Product Specification
Page 181
... Error Beep Codes Beeps Error Message 1 USB device action 1 long Intel® TXT security violation 3 Memory error 2 BIOS Recovery started 4 BIOS Recovery failure POST Progress Code NA 0xAE, 0xAF See Tables 28 and 29...BIOS recovery has failed. System halted because a fatal error related to shadow a Legacy Option ROM. Each digit in POST, or inserted or removed during runtime System halted because Intel® Trusted Execution Technology detected a potential violation of system security. Revision 1.1 167 Intel order number G34153-003 Intel® Server Board S2600IP and Intel...
... Error Beep Codes Beeps Error Message 1 USB device action 1 long Intel® TXT security violation 3 Memory error 2 BIOS Recovery started 4 BIOS Recovery failure POST Progress Code NA 0xAE, 0xAF See Tables 28 and 29...BIOS recovery has failed. System halted because a fatal error related to shadow a Legacy Option ROM. Each digit in POST, or inserted or removed during runtime System halted because Intel® Trusted Execution Technology detected a potential violation of system security. Revision 1.1 167 Intel order number G34153-003 Intel® Server Board S2600IP and Intel...
Service Guide
Page 112
...Date Option Values: Help Text: System Date has configurable fields for critical POST errors. [Disabled] - System Time 94 Intel® Server System P4000IP and Intel® Workstation System P4000CR Service Guide POST Error Pause Option Values: Enabled Disabled Help Text: [Enabled] - Attempt to ... logo screen during POST. Go to modify the selected field. Minor and fatal error displays are not affected by the "BIOS Defaults" jumper, BIOS Recovery Flash Update, or other method, the date will initially display the current system day of week and date. Saturday 01/01/...
...Date Option Values: Help Text: System Date has configurable fields for critical POST errors. [Disabled] - System Time 94 Intel® Server System P4000IP and Intel® Workstation System P4000CR Service Guide POST Error Pause Option Values: Enabled Disabled Help Text: [Enabled] - Attempt to ... logo screen during POST. Go to modify the selected field. Minor and fatal error displays are not affected by the "BIOS Defaults" jumper, BIOS Recovery Flash Update, or other method, the date will initially display the current system day of week and date. Saturday 01/01/...
Service Guide
Page 177
... signal is held asserted, rather than just pulsed to generate an SMI. System returns to the same state before hanging. 4. Intel® Server System P4000IP and Intel® Workstation System P4000CR Service Guide 159 Resume on AC Power Loss Option Values: Stay Off Last State Power On Help Text...: System action to take on and the system was on AC power loss recovery. [Stay Off] - BIOS Setup Utilities Comments: This ...
... signal is held asserted, rather than just pulsed to generate an SMI. System returns to the same state before hanging. 4. Intel® Server System P4000IP and Intel® Workstation System P4000CR Service Guide 159 Resume on AC Power Loss Option Values: Stay Off Last State Power On Help Text...: System action to take on and the system was on AC power loss recovery. [Stay Off] - BIOS Setup Utilities Comments: This ...
Service Guide
Page 23
...Intel® Server System R2000IP Service Guide 11 If pins 2-3 are selected, the Integrated BMC Force Update Mode is enabled. These pins should be selected on the next reset. Figure 14. System Recovery Jumpers Server System Features Jumper Name BMC Force Update (J1C1) BIOS Default (J1F1) BIOS...Clear (J2F3) ME Force Update (J2F2) Jumper Purpose If pins 2-3 are selected, the system can only boot from EFIbootable recovery media with the recovery BIOS image. These pins should be selected on 1-2 for normal system operation. These pins should be selected on 1-2 for normal ...
...Intel® Server System R2000IP Service Guide 11 If pins 2-3 are selected, the Integrated BMC Force Update Mode is enabled. These pins should be selected on the next reset. Figure 14. System Recovery Jumpers Server System Features Jumper Name BMC Force Update (J1C1) BIOS Default (J1F1) BIOS...Clear (J2F3) ME Force Update (J2F2) Jumper Purpose If pins 2-3 are selected, the system can only boot from EFIbootable recovery media with the recovery BIOS image. These pins should be selected on 1-2 for normal system operation. These pins should be selected on 1-2 for normal ...
Service Guide
Page 79
...earliest date in the allowed range - Display the diagnostic screen during POST. Minor and fatal error displays are not affected by the "BIOS Defaults" jumper, BIOS Recovery Flash Update, or other method, the date will initially display the current system day of week and date. POST Error Pause Option... field. Use [+] or [-] key to the Error Manager for critical POST errors. Go to change the system date. System Time Intel® Server System R2000IP Service Guide 67 Comments: This field will be between 2005 and 2099. When the System Date is displayed unconditionally...
...earliest date in the allowed range - Display the diagnostic screen during POST. Minor and fatal error displays are not affected by the "BIOS Defaults" jumper, BIOS Recovery Flash Update, or other method, the date will initially display the current system day of week and date. POST Error Pause Option... field. Use [+] or [-] key to the Error Manager for critical POST errors. Go to change the system date. System Time Intel® Server System R2000IP Service Guide 67 Comments: This field will be between 2005 and 2099. When the System Date is displayed unconditionally...
Service Guide
Page 142
...State] - System returns to the BMC. When this can result in POST, and also for the Setup Server Management screen. 6. Power Restore Delay 130 Intel® Server System R2000IP Service Guide when disabled system does not get reset on AC Power Loss Option Values: Stay Off Last State Power On...Last State, depending on whether the power was on and the system was running before hanging. 4. BIOS gets this Power Restore Policy setting and it on to boot the system, depending on AC power loss recovery. [Stay Off] - Note: If "Reset on ERR2" is Disabled, this setting is restored ...
...State] - System returns to the BMC. When this can result in POST, and also for the Setup Server Management screen. 6. Power Restore Delay 130 Intel® Server System R2000IP Service Guide when disabled system does not get reset on AC Power Loss Option Values: Stay Off Last State Power On...Last State, depending on whether the power was on and the system was running before hanging. 4. BIOS gets this Power Restore Policy setting and it on to boot the system, depending on AC power loss recovery. [Stay Off] - Note: If "Reset on ERR2" is Disabled, this setting is restored ...