Intel Server Board S1400FP Technical Product Specification
Page 38
...Intel® Server Board S1400FP TPS system remains running for a certain amount of time, the correctable error count will "leak out" of PCI Express*. This prevents correctable error counts from building up to 24 lanes of the counting registers. However, before returning control to the OS drivers...Handling All multi-bit "detectable but not correctable" memory errors are classified as a standard x4 PCI Express* 2.0 interface. 26 Revision 1.0 Intel order number G64246-001 Once a correctable memory error threshold is reached, the event is logged to the System Event Log (SEL) and ...
...Intel® Server Board S1400FP TPS system remains running for a certain amount of time, the correctable error count will "leak out" of PCI Express*. This prevents correctable error counts from building up to 24 lanes of the counting registers. However, before returning control to the OS drivers...Handling All multi-bit "detectable but not correctable" memory errors are classified as a standard x4 PCI Express* 2.0 interface. 26 Revision 1.0 Intel order number G64246-001 Once a correctable memory error threshold is reached, the event is logged to the System Event Log (SEL) and ...
Intel Server Board S1400FP Technical Product Specification
Page 42
...the Serial ATA II: Extensions to 6 SATA ports of the C600 chipset. AHCI requires appropriate software support (for example, an AHCI driver) and for some elements). 3.3.4 AHCI The C600 chipset provides hardware support for Advanced Host Controller Interface (AHCI), a standardized programming interface...chipset implements an SPI Interface as an alternative interface for the FWH, and is treated as Hot-Plug. Functional Architecture Intel® Server Board S1400FP TPS 3.3.3 Serial ATA (SATA) Controller The C600 chipset has two integrated SATA host controllers that support independent DMA ...
...the Serial ATA II: Extensions to 6 SATA ports of the C600 chipset. AHCI requires appropriate software support (for example, an AHCI driver) and for some elements). 3.3.4 AHCI The C600 chipset provides hardware support for Advanced Host Controller Interface (AHCI), a standardized programming interface...chipset implements an SPI Interface as an alternative interface for the FWH, and is treated as Hot-Plug. Functional Architecture Intel® Server Board S1400FP TPS 3.3.3 Serial ATA (SATA) Controller The C600 chipset has two integrated SATA host controllers that support independent DMA ...
Intel Server Board S1400FP Technical Product Specification
Page 47
... o 4 and 8 Port SAS RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key Maximum drive support = Eight (with or without SAS expander option installed) Open Source Compliance = Binary Driver (includes Partial Source files) or Open Source using partial source builds.... Utilities = Microsoft Windows* GUI and CLI, Linux* GUI and CLI, DOS CLI, and EFI CLI Revision 1.0 35 Intel order number G64246-001 Intel® Server Board S1400FP TPS Functional ...
... o 4 and 8 Port SAS RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key Maximum drive support = Eight (with or without SAS expander option installed) Open Source Compliance = Binary Driver (includes Partial Source files) or Open Source using partial source builds.... Utilities = Microsoft Windows* GUI and CLI, Linux* GUI and CLI, DOS CLI, and EFI CLI Revision 1.0 35 Intel order number G64246-001 Intel® Server Board S1400FP TPS Functional ...
Intel Server Board S1400FP Technical Product Specification
Page 48
...and EFI CLI Uses Matrix Storage Manager for Microsoft Windows* MDRAID supported in Linux* (Does not require a driver) Note: No boot drive support to targets attached through SAS expander card 3.4 Integrated Baseboard Management Controller (BMC) Overview The server ... Controller (BMC) Overview 36 Revision 1.0 Intel order number G64246-001 Figure 17. Functional Architecture Intel® Server Board S1400FP TPS 3.3.23.2 Intel® Rapid Storage Technology (RSTe) Features of the embedded software RAID option Intel® Rapid Storage Technology (RSTe) include...
...and EFI CLI Uses Matrix Storage Manager for Microsoft Windows* MDRAID supported in Linux* (Does not require a driver) Note: No boot drive support to targets attached through SAS expander card 3.4 Integrated Baseboard Management Controller (BMC) Overview The server ... Controller (BMC) Overview 36 Revision 1.0 Intel order number G64246-001 Figure 17. Functional Architecture Intel® Server Board S1400FP TPS 3.3.23.2 Intel® Rapid Storage Technology (RSTe) Features of the embedded software RAID option Intel® Rapid Storage Technology (RSTe) include...
Intel Server Board S1400FP Technical Product Specification
Page 94
Advanced Management Feature Support (RMM4) Intel® Server Board S1400FP TPS The media redirection feature supports multiple encryption ...appear as bootable devices. FD Redirection (Secure) 7578 - Video Redirection (Secure) 82 Revision 1.0 Intel order number G64246-001 USB storage devices will require the session to be re-established The mounted ...loss or BMC reset. 7.2.2 Network Port Usage The KVM and media redirection features use of device drivers during system boot, both pre-boot and post-boot states. The mounted device shows ...
Advanced Management Feature Support (RMM4) Intel® Server Board S1400FP TPS The media redirection feature supports multiple encryption ...appear as bootable devices. FD Redirection (Secure) 7578 - Video Redirection (Secure) 82 Revision 1.0 Intel order number G64246-001 USB storage devices will require the session to be re-established The mounted ...loss or BMC reset. 7.2.2 Network Port Usage The KVM and media redirection features use of device drivers during system boot, both pre-boot and post-boot states. The mounted device shows ...
Intel Server Board S1400FP Technical Product Specification
Page 148
... Intel® Server Board S1400FP TPS Diagnostic LED Decoder 1 = LED On, 0 = LED Off Checkpoint Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED # #7 #6 #5 #4 #3 #2 #1 #0 Description 78h 0 1 1 1 1 0 0 0 DXE ACPI Init 79h 0 1 1 1 1 0 0 1 DXE CSM Init 90h 1 0 0 1 0 0 0 0 DXE BDS Started 91h 1 0 0 1 0 0 0 1 DXE BDS connect drivers ...User Recovery condition F2h 1 1 1 1 0 0 1 0 Recovery PEIM (Recovery started) F3h 1 1 1 1 0 0 1 1 Recovery PEIM (Capsule found) F4h 1 1 1 1 0 1 0 0 Recovery PEIM (Capsule loaded) 136 Revision 1.0 Intel order number G64246-001
... Intel® Server Board S1400FP TPS Diagnostic LED Decoder 1 = LED On, 0 = LED Off Checkpoint Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED # #7 #6 #5 #4 #3 #2 #1 #0 Description 78h 0 1 1 1 1 0 0 0 DXE ACPI Init 79h 0 1 1 1 1 0 0 1 DXE CSM Init 90h 1 0 0 1 0 0 0 0 DXE BDS Started 91h 1 0 0 1 0 0 0 1 DXE BDS connect drivers ...User Recovery condition F2h 1 1 1 1 0 0 1 0 Recovery PEIM (Recovery started) F3h 1 1 1 1 0 0 1 1 Recovery PEIM (Capsule found) F4h 1 1 1 1 0 1 0 0 Recovery PEIM (Capsule loaded) 136 Revision 1.0 Intel order number G64246-001
Intel Server Board S1400FP Technical Product Specification
Page 155
...ACM Error PCI component encountered a SERR error PCI Express component encountered a PERR error PCI Express component encountered an SERR error DXE Boot Service driver: Not enough memory available to shadow a Legacy Option ROM Response Major Major Major Major Major Major Major Major Major Major Major Major Major... Minor Fatal Minor POST Error Beep Codes The following table lists the POST error beep codes. Recovery boot has been initiated. Intel® Server Board S1400FP TPS Appendix D: POST Code Errors Error Code 85DB 85DC 85DD 85DE 85DF 85E0 85E1 85E2 85E3 85E4 85E5 85E6 85E7 85E8...
...ACM Error PCI component encountered a SERR error PCI Express component encountered a PERR error PCI Express component encountered an SERR error DXE Boot Service driver: Not enough memory available to shadow a Legacy Option ROM Response Major Major Major Major Major Major Major Major Major Major Major Major Major... Minor Fatal Minor POST Error Beep Codes The following table lists the POST error beep codes. Recovery boot has been initiated. Intel® Server Board S1400FP TPS Appendix D: POST Code Errors Error Code 85DB 85DC 85DD 85DE 85DF 85E0 85E1 85E2 85E3 85E4 85E5 85E6 85E7 85E8...
Specification update
Page 3
...4. Sensor Readings Page - UEFI Operating System installation is connected through SAS expander to shut down Microsoft Windows 2008* R2 64bit 9 20. Intel® LAN driver installation failure on RSTe mode 4 2. Hard drives connected through mode of SCU controller ...5 8. RSTe GUI installation may fail if there are...may not function normally during HDD RAID rebuild under SuSE* Linux Enterprise Server 11 (64-bit) with default NIC driver for Intel® Gigabit ET Dual Port Server Adapter E1G42ET and Intel® Gigabit ET Quad Port Server Adapter E1G44ET.....8 15.
...4. Sensor Readings Page - UEFI Operating System installation is connected through SAS expander to shut down Microsoft Windows 2008* R2 64bit 9 20. Intel® LAN driver installation failure on RSTe mode 4 2. Hard drives connected through mode of SCU controller ...5 8. RSTe GUI installation may fail if there are...may not function normally during HDD RAID rebuild under SuSE* Linux Enterprise Server 11 (64-bit) with default NIC driver for Intel® Gigabit ET Dual Port Server Adapter E1G42ET and Intel® Gigabit ET Quad Port Server Adapter E1G44ET.....8 15.
Specification update
Page 6
... failure under specific configuration 5. Power Statistics page - Fix High CPU utilization may halt under ESRT2 mode of the SCU controller 14. Fixed Intel® LAN driver installation failure on RSTe mode 2. Fix Fault LED on ESRT2 mode 4. Fixed: This erratum has been previously fixed. Fix HDD status LEDs...on Microsoft Windows* 7 16. Fix RSTe GUI installation may fail under SuSE* Linux Enterprise Server 11 (64-bit) with default NIC driver for Intel® Gigabit ET Dual Port Server Adapter E1G42ET and Intel® Gigabit ET Quad Port Server Adapter E1G44ET 15.
... failure under specific configuration 5. Power Statistics page - Fix High CPU utilization may halt under ESRT2 mode of the SCU controller 14. Fixed Intel® LAN driver installation failure on RSTe mode 2. Fix Fault LED on ESRT2 mode 4. Fixed: This erratum has been previously fixed. Fix HDD status LEDs...on Microsoft Windows* 7 16. Fix RSTe GUI installation may fail under SuSE* Linux Enterprise Server 11 (64-bit) with default NIC driver for Intel® Gigabit ET Dual Port Server Adapter E1G42ET and Intel® Gigabit ET Quad Port Server Adapter E1G44ET 15.
Specification update
Page 8
... install UEFI OS under UEFI with mentioned configuration. Status This issue may be fixed in future driver or BIOS releases. BIOS options "EFI Optimized Boot" and "Use Legacy Video for EFI OS" are used on Intel® C600 Series Chipset based Server Boards with below configurations: 1. Workaround None. 4 Status This issue may...
... install UEFI OS under UEFI with mentioned configuration. Status This issue may be fixed in future driver or BIOS releases. BIOS options "EFI Optimized Boot" and "Use Legacy Video for EFI OS" are used on Intel® C600 Series Chipset based Server Boards with below configurations: 1. Workaround None. 4 Status This issue may...
Specification update
Page 9
... is attached to SCU ports and configured under mentioned configuration when the AHCI controller is selcted, system may be fixed in a future RAID driver. Implication User may not show the HDD locate, HDD fault or RAID rebuild message. System may not function properly. Microsoft Windows 2003*... plug a SATA device into one of SCU controller Problem Microsoft Windows Server 2003* x86 installations on SCU ports, the installation of RSTe drivers and the Graphic User Interface (GUI) in Microsoft Windows 2008* R2 will fail, if the AHCI controller is enabled while no devices ...
... is attached to SCU ports and configured under mentioned configuration when the AHCI controller is selcted, system may be fixed in a future RAID driver. Implication User may not show the HDD locate, HDD fault or RAID rebuild message. System may not function properly. Microsoft Windows 2003*... plug a SATA device into one of SCU controller Problem Microsoft Windows Server 2003* x86 installations on SCU ports, the installation of RSTe drivers and the Graphic User Interface (GUI) in Microsoft Windows 2008* R2 will fail, if the AHCI controller is enabled while no devices ...
Specification update
Page 10
... page may display the minimun wattage as zero. System may halt under ESRT2 mode while SAS drivers are used and ESRT2 enabled. Implication User may see a system halt with no Intel® C600 RAID upgrade key (any of RKSAS4, RKSAS4R5, RKSAS8, RKSAS8R5) is an incorrect...gets grayed out and cannot be fixed in the Integrated BMC Web Console and then return to request another page in a future RSTe driver release. Implication You cannot perform a power on mentined BIOS configuration. Perform Action button not functional. Power Control page - Workaround Select another...
... page may display the minimun wattage as zero. System may halt under ESRT2 mode while SAS drivers are used and ESRT2 enabled. Implication User may see a system halt with no Intel® C600 RAID upgrade key (any of RKSAS4, RKSAS4R5, RKSAS8, RKSAS8R5) is an incorrect...gets grayed out and cannot be fixed in the Integrated BMC Web Console and then return to request another page in a future RSTe driver release. Implication You cannot perform a power on mentined BIOS configuration. Perform Action button not functional. Power Control page - Workaround Select another...
Specification update
Page 12
...DPC rate steadily increases until the system slows to OS. Implication Users can be fixed in legacy mode (default BIOS setting). Intel® LAN driver installation failure on Microsoft Windows 7* with the .bat installation scripts in legacy mode Problem If hard drives are availalbe: 1. ...to SCU ports and configured under RSTe mode, the hard drives can 't be installed sucessfully on Microsoft Windows* 7 Problem The Intel® LAN driver version 16.8 and below may be manually installed. 2. Hard drives connected through expander to install OS. Status The issue is ...
...DPC rate steadily increases until the system slows to OS. Implication Users can be fixed in legacy mode (default BIOS setting). Intel® LAN driver installation failure on Microsoft Windows 7* with the .bat installation scripts in legacy mode Problem If hard drives are availalbe: 1. ...to SCU ports and configured under RSTe mode, the hard drives can 't be installed sucessfully on Microsoft Windows* 7 Problem The Intel® LAN driver version 16.8 and below may be manually installed. 2. Hard drives connected through expander to install OS. Status The issue is ...
Specification update
Page 14
... Problem If system is no throttling. Workaround None. 10 Status This issue may not function under Red Hat* Linux 6.2 64bit OS Problem With Intel® LAN driver version 17.1, WOL (Wake on 4x3.5" hot swap HDD cage may not be fixed in a future ME release. No functional impact to the.../or P2 MTT" status as "Critical" even when there is configured as AHCI ESRTII RAID, HDD Fault LED may be fixed in a future LAN driver release. Memory Throttling sensor status will stay "Critical" once triggered Problem When Memory Throttling is triggered, the Memory "P1 MTT and/or P2 MTT"...
... Problem If system is no throttling. Workaround None. 10 Status This issue may not function under Red Hat* Linux 6.2 64bit OS Problem With Intel® LAN driver version 17.1, WOL (Wake on 4x3.5" hot swap HDD cage may not be fixed in a future ME release. No functional impact to the.../or P2 MTT" status as "Critical" even when there is configured as AHCI ESRTII RAID, HDD Fault LED may be fixed in a future LAN driver release. Memory Throttling sensor status will stay "Critical" once triggered Problem When Memory Throttling is triggered, the Memory "P1 MTT and/or P2 MTT"...