Hardware Maintenance Manual
Page 173
... 2. System Board. 1. System Board 1. System Board. 1. System Board 1. System Board 1. Error Code/Symptom 001-XXX-000 (Failed core tests) 001-XXX-001 (Failed core tests) 001-250-000 (Failed System Board ECC) 001-250-001 (Failed System Board ECC) 005-XXX-000 (Failed Video test) 011-XXX-000 (Failed COM1 Serial Port...XXX-015 (Failed USB External Loopback test) 015-XXX-198 (USB device connected during USB test) 020-XXX-000 (Failed PCI Interface test) 020-XXX-001 (Failed Hot-Swap Slot 1 PCI Latch test) 020-XXX-002 (Failed Hot-Swap Slot 2 PCI Latch test) FRU/Action 1. System Board 1. ...
... 2. System Board. 1. System Board 1. System Board. 1. System Board 1. System Board 1. Error Code/Symptom 001-XXX-000 (Failed core tests) 001-XXX-001 (Failed core tests) 001-250-000 (Failed System Board ECC) 001-250-001 (Failed System Board ECC) 005-XXX-000 (Failed Video test) 011-XXX-000 (Failed COM1 Serial Port...XXX-015 (Failed USB External Loopback test) 015-XXX-198 (USB device connected during USB test) 020-XXX-000 (Failed PCI Interface test) 020-XXX-001 (Failed Hot-Swap Slot 1 PCI Latch test) 020-XXX-002 (Failed Hot-Swap Slot 2 PCI Latch test) FRU/Action 1. System Board 1. ...
Hardware Maintenance Manual
Page 175
Error Code/Symptom 035-253-S99 (RAID adapter initialization failure) 075-XXX-000 (Failed Power Supply test) 089-XXX-001 (Failed Microprocessor test) 089-XXX-002 (Failed Optional Microprocessor test) 089-XXX-003 (Failed Optional Microprocessor test) 089-XXX-004 (Failed Optional... Microprocessor test) 165-XXX-000 (Failed Service Processor test) 180-XXX-000 (Diagnostics LED failure) 180-XXX-001 (Failed information LED panel test) 180-XXX-002 (Failed Diagnostics LED Panel test) 180-XXX-003 (Failed System Board LED test) FRU/Action 1. Microprocessor...
Error Code/Symptom 035-253-S99 (RAID adapter initialization failure) 075-XXX-000 (Failed Power Supply test) 089-XXX-001 (Failed Microprocessor test) 089-XXX-002 (Failed Optional Microprocessor test) 089-XXX-003 (Failed Optional Microprocessor test) 089-XXX-004 (Failed Optional... Microprocessor test) 165-XXX-000 (Failed Service Processor test) 180-XXX-000 (Diagnostics LED failure) 180-XXX-001 (Failed information LED panel test) 180-XXX-002 (Failed Diagnostics LED Panel test) 180-XXX-003 (Failed System Board LED test) FRU/Action 1. Microprocessor...
Hardware Maintenance Manual
Page 176
... card 1. System Board 1. Microprocessor CPU 2 1. Cable 2. System Board 1. System Board 1. Microprocessor CPU 4 1. SCSI Backplane 2. CD-ROM Drive 3. Fixed Disk 1 164 Netfinity 6000R Type 8682 Models 1RY, 2RY Error Code/Symptom 180-XXX-004 (Failed Processor LED test) 180-XXX-005 (Failed SCSI Backplane LED test) 180-XXX-006 (Memory...test, see "Memory Settings" on page 47.) NN = DIMM location. 201-XXX-999 (Multiple DIMM failure, see error text.) 202-XXX-001 (Failed System Cache test) 202-XXX-002 (Failed System Cache test) 202-XXX-003 (Failed System Cache test) 202-XXX-004 (Failed ...
... card 1. System Board 1. Microprocessor CPU 2 1. Cable 2. System Board 1. System Board 1. Microprocessor CPU 4 1. SCSI Backplane 2. CD-ROM Drive 3. Fixed Disk 1 164 Netfinity 6000R Type 8682 Models 1RY, 2RY Error Code/Symptom 180-XXX-004 (Failed Processor LED test) 180-XXX-005 (Failed SCSI Backplane LED test) 180-XXX-006 (Memory...test, see "Memory Settings" on page 47.) NN = DIMM location. 201-XXX-999 (Multiple DIMM failure, see error text.) 202-XXX-001 (Failed System Cache test) 202-XXX-002 (Failed System Cache test) 202-XXX-003 (Failed System Cache test) 202-XXX-004 (Failed ...
Hardware Maintenance Manual
Page 177
Fixed Disk 3 1. Fixed Disk 4 1. Fixed Disk 2 1. Fixed Disk 5 1. Fixed Disk 6 Symptom-to the RAID logical array. FRU/Action 1. Error Code/Symptom 217-XXX-001 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-002 (Failed BIOS ...
Fixed Disk 3 1. Fixed Disk 4 1. Fixed Disk 2 1. Fixed Disk 5 1. Fixed Disk 6 Symptom-to the RAID logical array. FRU/Action 1. Error Code/Symptom 217-XXX-001 (Failed BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 217-XXX-002 (Failed BIOS ...