Owner's Manual
Page 2
... particular application, but replace the filter at www.honeywell.com/yourhome/ Ultraviolet Air Treatment System Zap airborne germs and prevent mold growth on our web site for your unit from your heating and cooling system. 69-1866-01 2 Replacement Filter Chart Media Air Cleaner Replacement Model Filter Cartridge RMAC1625 CF200A1008 RMAC2025 CF200A1016 Replacement Filter Size 16" X 25" 20...
... particular application, but replace the filter at www.honeywell.com/yourhome/ Ultraviolet Air Treatment System Zap airborne germs and prevent mold growth on our web site for your unit from your heating and cooling system. 69-1866-01 2 Replacement Filter Chart Media Air Cleaner Replacement Model Filter Cartridge RMAC1625 CF200A1008 RMAC2025 CF200A1016 Replacement Filter Size 16" X 25" 20...
Owner's Manual
Page 3
... HVAC installer to follow them could damage the media air filter or cause a hazardous condition. 3. Depending on the media air cleaner to HVAC components. Read these instructions carefully before installing or servicing media air cleaner. WARNING Can cause personal injury or equipment damage.... Included in the instructions and on the application this device professionally installed. 2. CF200 Media Air Filter - Sheet-metal Screws, Rivets, or Slip-joints - Installation of the following to complete the installation: Tin snips...
... HVAC installer to follow them could damage the media air filter or cause a hazardous condition. 3. Depending on the media air cleaner to HVAC components. Read these instructions carefully before installing or servicing media air cleaner. WARNING Can cause personal injury or equipment damage.... Included in the instructions and on the application this device professionally installed. 2. CF200 Media Air Filter - Sheet-metal Screws, Rivets, or Slip-joints - Installation of the following to complete the installation: Tin snips...
Owner's Manual
Page 4
... ensuring that all local building codes and standards. Highboy furnace with installation beneath furnace. MEDIA AIR CLEANER HOW TO INSTALL YOUR MEDIA AIR CLEANER IMPORTANT: Due to differences in how furnaces are given in Fig. 11. • Make...the filter. NOTE: Every installation is impossible to provide detailed instructions that the get fciloteldrecratrhtraidng-e4.0° F • Make sure filter pressure drop will reach the filter cartridge. • The media air cleaner can be mounted in any ultraviolet air treatment system, such as the Honeywell RUVLAMP1...
... ensuring that all local building codes and standards. Highboy furnace with installation beneath furnace. MEDIA AIR CLEANER HOW TO INSTALL YOUR MEDIA AIR CLEANER IMPORTANT: Due to differences in how furnaces are given in Fig. 11. • Make...the filter. NOTE: Every installation is impossible to provide detailed instructions that the get fciloteldrecratrhtraidng-e4.0° F • Make sure filter pressure drop will reach the filter cartridge. • The media air cleaner can be mounted in any ultraviolet air treatment system, such as the Honeywell RUVLAMP1...
Owner's Manual
Page 6
M13644 Fig. 10. Horizontal furnace with media air cleaner mounted horizontally in return duct near furnace. 0.300 1 0.250 FILTER SIZE 20 X 25 16 X 25 PRESSURE DROP (IN. Pressure drop versus airflow of CF200A media filter. 69-1866-01 6 REPLACE FILTER WHEN PRESSURE DROP REACHES 0.5 IN. WC. (0.1 kPa). MEDIA AIR CLEANER M944A Fig. 8. WC) 0.200 0.150 0.100...
M13644 Fig. 10. Horizontal furnace with media air cleaner mounted horizontally in return duct near furnace. 0.300 1 0.250 FILTER SIZE 20 X 25 16 X 25 PRESSURE DROP (IN. Pressure drop versus airflow of CF200A media filter. 69-1866-01 6 REPLACE FILTER WHEN PRESSURE DROP REACHES 0.5 IN. WC. (0.1 kPa). MEDIA AIR CLEANER M944A Fig. 8. WC) 0.200 0.150 0.100...
Owner's Manual
Page 8
.... you will need to make room for media air cleaner. Turning vanes help distribute airflow evenly over media. NOTE: Media Air Cleaner cannot remove dirt that is less than 7 in . (178 mm) Prepare Furnace for details. 4. FURNACE FILTER M13645 Fig. 15. Duct Offsets • If...Turning vanes may be properly secured to make room for media air cleaner 69-1866-01 8 Disconnect power to distribute airflow more evenly across the face of duct offsets to prevent movement. 3. Remove and discard existing furnace filter. Thoroughly clean the blower compartment using a power vacuum (Shop...
.... you will need to make room for media air cleaner. Turning vanes help distribute airflow evenly over media. NOTE: Media Air Cleaner cannot remove dirt that is less than 7 in . (178 mm) Prepare Furnace for details. 4. FURNACE FILTER M13645 Fig. 15. Duct Offsets • If...Turning vanes may be properly secured to make room for media air cleaner 69-1866-01 8 Disconnect power to distribute airflow more evenly across the face of duct offsets to prevent movement. 3. Remove and discard existing furnace filter. Thoroughly clean the blower compartment using a power vacuum (Shop...
Owner's Manual
Page 9
... joints. Seal Duct Joints 1. Disconnect Existing Ductwork NOTE: Skip this step if the media air cleaner is to be installed. See Fig. 16. 2. Remove door and filter cartridge from air cleaner cabinet. Review the installation location and verify that all duct joints in position, oriented ... position. Fasten Ductwork to Cabinet Fasten side of media air cleaner cabinet to change filter. Add support straps and bracing to match the air cleaner cabinet opening. 5. Seal all sheet-metal components, such as appropriate. MEDIA AIR CLEANER 26 IN. (637 MM) MINIMUM M13646 Fig....
... joints. Seal Duct Joints 1. Disconnect Existing Ductwork NOTE: Skip this step if the media air cleaner is to be installed. See Fig. 16. 2. Remove door and filter cartridge from air cleaner cabinet. Review the installation location and verify that all duct joints in position, oriented ... position. Fasten Ductwork to Cabinet Fasten side of media air cleaner cabinet to change filter. Add support straps and bracing to match the air cleaner cabinet opening. 5. Seal all sheet-metal components, such as appropriate. MEDIA AIR CLEANER 26 IN. (637 MM) MINIMUM M13646 Fig....
Owner's Manual
Page 10
... DATE INSTALLED: 1/1/2006 Sign up to 30% in your records. 69-1866-01 10 www.honeywell.com/yourhome/ NOTE DIRECTION OF AIR FLOW (TOWARDS FURNACE) FURNACE WRITE FILTER INSTALLATION DATE HERE *Aprilaire® and Space-Gard® are properly installed. All joints...4. See Fig. 17. CHECKOUT 1. Replace any ultraviolet air treatment system that you use thermostat that's accurate to within +/- 1 Replace filters every 12 months, or more information about Honeywell Indoor Air Quality products, visit: http://yourhome.honeywell.com or call:1-800-345-6770 x531 IMPORTANT Please read...
... DATE INSTALLED: 1/1/2006 Sign up to 30% in your records. 69-1866-01 10 www.honeywell.com/yourhome/ NOTE DIRECTION OF AIR FLOW (TOWARDS FURNACE) FURNACE WRITE FILTER INSTALLATION DATE HERE *Aprilaire® and Space-Gard® are properly installed. All joints...4. See Fig. 17. CHECKOUT 1. Replace any ultraviolet air treatment system that you use thermostat that's accurate to within +/- 1 Replace filters every 12 months, or more information about Honeywell Indoor Air Quality products, visit: http://yourhome.honeywell.com or call:1-800-345-6770 x531 IMPORTANT Please read...