Installation Instructions
Page 1
...installation or servicing. • This device contains a moving fan blade; IMPORTANT Mount the humidifier at least 3 in the instructions and on the upper ...4. Remove the template and carefully cut or drill into any Honeywell humidity control, and can occur. • Do not install humidifier where freezing temperatures could damage the product or cause a hazardous.... 9. Template (entire sheet) Top of Humidifier HE365 Powered Flow-Through Humidifier READ AND SAVE THESE INSTRUCTIONS APPLICATION The HE365 Powered Flow-Through Humidifier works with the warm air furnace blower to...
...installation or servicing. • This device contains a moving fan blade; IMPORTANT Mount the humidifier at least 3 in the instructions and on the upper ...4. Remove the template and carefully cut or drill into any Honeywell humidity control, and can occur. • Do not install humidifier where freezing temperatures could damage the product or cause a hazardous.... 9. Template (entire sheet) Top of Humidifier HE365 Powered Flow-Through Humidifier READ AND SAVE THESE INSTRUCTIONS APPLICATION The HE365 Powered Flow-Through Humidifier works with the warm air furnace blower to...
Installation Instructions
Page 2
... supply line at an appropriate location. hose to the humidifier drain fitting and run it to the inlet side of Humidifier 2 MECHANICAL HUMIDISTAT HUMIDIFIER TO BLOWER 1 MOTOR IGNITION BOX 120 VAC YELLOW WIRES 1 POWER SUPPLY. CHECKOUT 1. Check for frost and HVAC fan operation. M30128 Fig. 9. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive...
... supply line at an appropriate location. hose to the humidifier drain fitting and run it to the inlet side of Humidifier 2 MECHANICAL HUMIDISTAT HUMIDIFIER TO BLOWER 1 MOTOR IGNITION BOX 120 VAC YELLOW WIRES 1 POWER SUPPLY. CHECKOUT 1. Check for frost and HVAC fan operation. M30128 Fig. 9. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive...
Owners Manual
Page 7
... or junction. • Locate the switch on the opposite side of the duct from the humidifier in the return air duct. (See Fig 2.) 7 69-1176-04 Sail switch detects when furnace fan is operating. • Select a location where the air duct is in the direct path ... vertical (up or down) or horizontal. Airflow at least 3 in the humidifier and either hard or soft water in . (78 mm) above the humidifier so you install the Honeywell Whole House Drum or Disk Humidifier. HE360A,B POWERED FLOW-THROUGH HUMIDIFIER • Select a location that cannot damage the air conditioner A-coil during ...
... or junction. • Locate the switch on the opposite side of the duct from the humidifier in the return air duct. (See Fig 2.) 7 69-1176-04 Sail switch detects when furnace fan is operating. • Select a location where the air duct is in the direct path ... vertical (up or down) or horizontal. Airflow at least 3 in the humidifier and either hard or soft water in . (78 mm) above the humidifier so you install the Honeywell Whole House Drum or Disk Humidifier. HE360A,B POWERED FLOW-THROUGH HUMIDIFIER • Select a location that cannot damage the air conditioner A-coil during ...
Owners Manual
Page 21
...and listen for faint click. turn on furnace fan, turn on furnace fan and listen for contact to click. check sail switch instructions to do Leaking joints. Plumbing Verify plumbing connections. TROUBLESHOOTING YOUR HUMIDIFIER Problem Water leakage No water to click. Table...to drain. Tighten connections. Shut off water. Verify rubber gasket is open. Brass tubing inserts Verify that outlet has power. Humidifier power Verify that brass tubing inserts are used. Sail switch Remove sail cover; Saddle valve Verify that Saddle Valve needle ...
...and listen for faint click. turn on furnace fan, turn on furnace fan and listen for contact to click. check sail switch instructions to do Leaking joints. Plumbing Verify plumbing connections. TROUBLESHOOTING YOUR HUMIDIFIER Problem Water leakage No water to click. Table...to drain. Tighten connections. Shut off water. Verify rubber gasket is open. Brass tubing inserts Verify that outlet has power. Humidifier power Verify that brass tubing inserts are used. Sail switch Remove sail cover; Saddle valve Verify that Saddle Valve needle ...
Owners Manual
Page 22
... exhaust fan running time to eliminate condensation caused by moisture from bathing, mopping, cooking, etc. Check that the furnace power is needed. 69-1176-04 22 Check all external wiring connections. Turn off humidity control and water until condensation is an added load to • the humidifier). HE360A,B POWERED FLOW-THROUGH HUMIDIFIER Table 3. Troubleshooting Humidifier (Continued...
... exhaust fan running time to eliminate condensation caused by moisture from bathing, mopping, cooking, etc. Check that the furnace power is needed. 69-1176-04 22 Check all external wiring connections. Turn off humidity control and water until condensation is an added load to • the humidifier). HE360A,B POWERED FLOW-THROUGH HUMIDIFIER Table 3. Troubleshooting Humidifier (Continued...