HP ROM-Based Setup Utility User Guide
Page 1
HP ROM-Based Setup Utility User Guide Abstract This document details how to access and use the HP ROM-Based Setup Utility that is for the person who installs, administers, and troubleshoots servers and storage systems. HP Part Number: 761393-001 Published: February 2014 Edition: 1 This document is embedded in the system ROM of all HP ProLiant Generation 2 through 8 servers (except the HP ProLiant DL580 Gen8 server). All options and available responses are defined.
HP ROM-Based Setup Utility User Guide Abstract This document details how to access and use the HP ROM-Based Setup Utility that is for the person who installs, administers, and troubleshoots servers and storage systems. HP Part Number: 761393-001 Published: February 2014 Edition: 1 This document is embedded in the system ROM of all HP ProLiant Generation 2 through 8 servers (except the HP ProLiant DL580 Gen8 server). All options and available responses are defined.
HP ROM-Based Setup Utility User Guide
Page 3
... 9 Overview...9 Running RBSU...9 Using this guide...10 2 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers)...11 RBSU main menu...11 System Options menu...12 Serial Port options...12 Embedded Serial Port...12 Virtual Serial Port...14 Embedded Serial......39 NUMLOCK Power-On State 41 SATA Controller Options (Gen8 servers with SATA controllers 42 Embedded SATA Configuration 42 Drive Write Cache...43 HP Smart Array B320i RAID Configuration 44 Power Management Options menu 45 HP Power Profile...45 HP Power Regulator...46 Redundant Power Supply Mode 47 Advanced Power...
... 9 Overview...9 Running RBSU...9 Using this guide...10 2 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers)...11 RBSU main menu...11 System Options menu...12 Serial Port options...12 Embedded Serial Port...12 Virtual Serial Port...14 Embedded Serial......39 NUMLOCK Power-On State 41 SATA Controller Options (Gen8 servers with SATA controllers 42 Embedded SATA Configuration 42 Drive Write Cache...43 HP Smart Array B320i RAID Configuration 44 Power Management Options menu 45 HP Power Profile...45 HP Power Regulator...46 Redundant Power Supply Mode 47 Advanced Power...
HP ROM-Based Setup Utility User Guide
Page 4
... Timeout...79 Thermal Shutdown...80 Wake-On LAN...81 POST F1 Prompt...82 Power Button...83 Automatic Power-On (G7 servers 84 Automatic Power-On (Gen8 servers 85 Power-On Delay...86 Server Security menu...87 Set Power-On Password...87 Set Admin Password...88 Network Server Mode...89 Intelligent Provisioning...
... Timeout...79 Thermal Shutdown...80 Wake-On LAN...81 POST F1 Prompt...82 Power Button...83 Automatic Power-On (G7 servers 84 Automatic Power-On (Gen8 servers 85 Power-On Delay...86 Server Security menu...87 Set Power-On Password...87 Set Admin Password...88 Network Server Mode...89 Intelligent Provisioning...
HP ROM-Based Setup Utility User Guide
Page 6
User Default Options...155 Utility Language menu (G5 through G7 servers 156 Utility Language menu (Gen8 servers 157 3 RBSU menu-driven interface, version 2.xx (G5 and earlier servers 158 RBSU main menu...158 System Options menu...158 Embedded Serial Port A......Embedded NICs...162 Diskette Write Control...162 Diskette Boot Control...162 Advanced Memory Protection 163 USB Control...164 USB 2.0 EHCI Controller 164 Power Regulator for ProLiant 165 USB External Port Capability 166 Ultra Low Power State...167 PCI Devices menu...168 Standard Boot Order (IPL) menu 169 Boot Controller Order menu...
User Default Options...155 Utility Language menu (G5 through G7 servers 156 Utility Language menu (Gen8 servers 157 3 RBSU menu-driven interface, version 2.xx (G5 and earlier servers 158 RBSU main menu...158 System Options menu...158 Embedded Serial Port A......Embedded NICs...162 Diskette Write Control...162 Diskette Boot Control...162 Advanced Memory Protection 163 USB Control...164 USB 2.0 EHCI Controller 164 Power Regulator for ProLiant 165 USB External Port Capability 166 Ultra Low Power State...167 PCI Devices menu...168 Standard Boot Order (IPL) menu 169 Boot Controller Order menu...
HP ROM-Based Setup Utility User Guide
Page 9
1 Introduction Overview HP ProLiant Generation 2 through and modify settings in the menu-driven interface, use the keystrokes defined in the following table. Key Up or down arrow Enter F1 ... RBSU, press Esc until the main menu is displayed. 2. NOTE: Throughout the RBSU menus, the RBSU attempts to display the proper marketing name for the HP ProLiant DL580 Gen8 server) include a configuration utility that may include: • Configuring system devices and installed options • Displaying system information • Selecting the primary boot controller...
1 Introduction Overview HP ProLiant Generation 2 through and modify settings in the menu-driven interface, use the keystrokes defined in the following table. Key Up or down arrow Enter F1 ... RBSU, press Esc until the main menu is displayed. 2. NOTE: Throughout the RBSU menus, the RBSU attempts to display the proper marketing name for the HP ProLiant DL580 Gen8 server) include a configuration utility that may include: • Configuring system devices and installed options • Displaying system information • Selecting the primary boot controller...
HP ROM-Based Setup Utility User Guide
Page 10
Using this guide RBSU is described as follows in this guide: • Chapter 1: "Introduction" (page 9) • Chapter 2: "RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers)" (page 11) • Chapter 3: "RBSU menu-driven interface, version 2.xx (G5 and earlier servers)" (page 158) • Chapter 4: "RBSU BIOS Serial Console (CLI)" (page 189) • Chapter 5: "RBSU configuration flows (manual and scripted)" (page 200) • Chapter 6: "ROM-based utilities" (page 205) 10 Introduction
Using this guide RBSU is described as follows in this guide: • Chapter 1: "Introduction" (page 9) • Chapter 2: "RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers)" (page 11) • Chapter 3: "RBSU menu-driven interface, version 2.xx (G5 and earlier servers)" (page 158) • Chapter 4: "RBSU BIOS Serial Console (CLI)" (page 189) • Chapter 5: "RBSU configuration flows (manual and scripted)" (page 200) • Chapter 6: "ROM-based utilities" (page 205) 10 Introduction
HP ROM-Based Setup Utility User Guide
Page 11
...; DL385 G6 • DL785 G6 • DL585 G6 For RBSU information for G6, G7, and Gen8 servers contain many of the screen, a window displays basic server information, including the server model, serial number, BIOS version, backup BIOS version, memory installed, and ... on the server model. In this document, if a feature is included in this chapter. 2 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) NOTE: The RBSU for these G6 servers, see "RBSU menu-driven interface, version 2.xx (G5 and earlier servers)" (page 158).
...; DL385 G6 • DL785 G6 • DL585 G6 For RBSU information for G6, G7, and Gen8 servers contain many of the screen, a window displays basic server information, including the server model, serial number, BIOS version, backup BIOS version, memory installed, and ... on the server model. In this document, if a feature is included in this chapter. 2 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) NOTE: The RBSU for these G6 servers, see "RBSU menu-driven interface, version 2.xx (G5 and earlier servers)" (page 158).
HP ROM-Based Setup Utility User Guide
Page 12
... "Remote Console Mode" (page 39) • "NUMLOCK Power-On State" (page 41) • "SATA Controller Options (Gen8 servers with SATA controllers)" (page 42) • "HP Smart Array B320i RAID Configuration" (page 44) Serial Port options Depending on the server model. 12 RBSU menu-driven interface, version ...3.xx or later (G6, G7, and Gen8 servers) Depending on your server model, options may include: • "...
... "Remote Console Mode" (page 39) • "NUMLOCK Power-On State" (page 41) • "SATA Controller Options (Gen8 servers with SATA controllers)" (page 42) • "HP Smart Array B320i RAID Configuration" (page 44) Serial Port options Depending on the server model. 12 RBSU menu-driven interface, version ...3.xx or later (G6, G7, and Gen8 servers) Depending on your server model, options may include: • "...
HP ROM-Based Setup Utility User Guide
Page 14
... 3 • Disabled NOTE: The COM ports listed and the default setting vary depending on the HP website (http://www.hp.com/go/ilo/docs). 14 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Virtual Serial Port The Virtual Serial Port option assigns the logical COM port number and...
... 3 • Disabled NOTE: The COM ports listed and the default setting vary depending on the HP website (http://www.hp.com/go/ilo/docs). 14 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Virtual Serial Port The Virtual Serial Port option assigns the logical COM port number and...
HP ROM-Based Setup Utility User Guide
Page 15
Embedded Serial Port Connector NOTE: This option is attached. • Front Serial Port-Disables auto-switching and always have the embedded serial port function via the front serial port when the SUV cable is not attached, but automatically switches to SUV Cable (default)-Functions via the front serial port. System Options menu 15 Options include: • Automatically Switch to the SUV cable if it is available only on some Gen8 servers. This Embedded Serial Port Connector option controls how the system uses the embedded front serial port.
Embedded Serial Port Connector NOTE: This option is attached. • Front Serial Port-Disables auto-switching and always have the embedded serial port function via the front serial port when the SUV cable is not attached, but automatically switches to SUV Cable (default)-Functions via the front serial port. System Options menu 15 Options include: • Automatically Switch to the SUV cable if it is available only on some Gen8 servers. This Embedded Serial Port Connector option controls how the system uses the embedded front serial port.
HP ROM-Based Setup Utility User Guide
Page 16
... key to display the following settings: • Network Boot • Disabled 16 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) NOTE: • When enabling Network Boot support for embedded NICs. Embedded NICs These boot options enable or disable network boot for an embedded NIC..., the NIC will not show up in the Standard Boot Order (IPL) until the next reboot. • For Gen8 servers, this , the RBSU menu may offer a network boot option that does nothing. These settings provide no functionality if an embedded NIC is bootable...
... key to display the following settings: • Network Boot • Disabled 16 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) NOTE: • When enabling Network Boot support for embedded NICs. Embedded NICs These boot options enable or disable network boot for an embedded NIC..., the NIC will not show up in the Standard Boot Order (IPL) until the next reboot. • For Gen8 servers, this , the RBSU menu may offer a network boot option that does nothing. These settings provide no functionality if an embedded NIC is bootable...
HP ROM-Based Setup Utility User Guide
Page 18
... a spare group of memory that would otherwise result in Advanced ECC see the HP ProLiant Server Memory website (http://h18004.www1.hp.com/products/servers/technology/memoryprotection.html). 18 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) This memory is receiving excessive correctable memory errors. For be corrected in...
... a spare group of memory that would otherwise result in Advanced ECC see the HP ProLiant Server Memory website (http://h18004.www1.hp.com/products/servers/technology/memoryprotection.html). 18 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) This memory is receiving excessive correctable memory errors. For be corrected in...
HP ROM-Based Setup Utility User Guide
Page 20
... IMPORTANT: Disabling Legacy USB Support removes the ability to display the available settings. 20 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Depending on your server model, options may include the following: Option USB Enabled (default) USB Disabled Description Servers supported All USB ports and embedded...
... IMPORTANT: Disabling Legacy USB Support removes the ability to display the available settings. 20 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Depending on your server model, options may include the following: Option USB Enabled (default) USB Disabled Description Servers supported All USB ports and embedded...
HP ROM-Based Setup Utility User Guide
Page 22
USB Boot Support controls whether the system boots from USB devices connected to the server. When disabled, this option also disables booting of iLO virtual media. Options include: • Enabled (default) • Disabled 22 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) USB Boot Support NOTE: This option is available on Gen8 servers.
USB Boot Support controls whether the system boots from USB devices connected to the server. When disabled, this option also disables booting of iLO virtual media. Options include: • Enabled (default) • Disabled 22 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) USB Boot Support NOTE: This option is available on Gen8 servers.
HP ROM-Based Setup Utility User Guide
Page 23
...Media Boot Sequence This option enables the user to the pre-OS BIOS control of USB. NOTE: This option is not enumerated for the HP ProLiant DL580 Gen8 server. Options include: • Internal SD Card First • Internal DriveKeys First • External DriveKeys First (default) USB Drive ...Key Enumeration By default the BIOS enumerates a USB drive key and treats it is available on HP ProLiant Gen8 servers, except for the device. This only applies to select which USB port or SD card slot the system searches first when enumerating boot...
...Media Boot Sequence This option enables the user to the pre-OS BIOS control of USB. NOTE: This option is not enumerated for the HP ProLiant DL580 Gen8 server. Options include: • Internal SD Card First • Internal DriveKeys First • External DriveKeys First (default) USB Drive ...Key Enumeration By default the BIOS enumerates a USB drive key and treats it is available on HP ProLiant Gen8 servers, except for the device. This only applies to select which USB port or SD card slot the system searches first when enumerating boot...
HP ROM-Based Setup Utility User Guide
Page 25
... 30) • "Enhanced Processor Core Disable (Intel Core Select)" (page 31) • "Processor Core Disable (AMD Core Select)" (page 33) • "Intel Turbo Boost Technology (Gen8 servers)" (page 34) • "Intel Turbo Boost Technology (G7 servers)" (page 35) • "AMD Core Performance Boost" (page 36) • "Intel VT-d" (page 37) •...
... 30) • "Enhanced Processor Core Disable (Intel Core Select)" (page 31) • "Processor Core Disable (AMD Core Select)" (page 33) • "Intel Turbo Boost Technology (Gen8 servers)" (page 34) • "Intel Turbo Boost Technology (G7 servers)" (page 35) • "AMD Core Performance Boost" (page 36) • "Intel VT-d" (page 37) •...
HP ROM-Based Setup Utility User Guide
Page 26
... as VMware ESX/ESXi and Windows Hyper-V, be sure to enable this option. 26 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Viruses that protects systems against malicious code and viruses. When used in combination with Intel processors. Options include: • Enabled (default) • Disabled NOTE...
... as VMware ESX/ESXi and Windows Hyper-V, be sure to enable this option. 26 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Viruses that protects systems against malicious code and viruses. When used in combination with Intel processors. Options include: • Enabled (default) • Disabled NOTE...
HP ROM-Based Setup Utility User Guide
Page 28
Options include: • Enabled (default) • Disabled 28 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Intel Virtualization Technology NOTE: This option is available on servers with Intel processors. When enabled, a hypervisor supporting this feature can use extra hardware capabilities provided by Intel.
Options include: • Enabled (default) • Disabled 28 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Intel Virtualization Technology NOTE: This option is available on servers with Intel processors. When enabled, a hypervisor supporting this feature can use extra hardware capabilities provided by Intel.
HP ROM-Based Setup Utility User Guide
Page 30
... the documentation for your processor model. Options include: • Enabled (default) • Disabled 30 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Intel Hyperthreading Options NOTE: This option is supported through the system BIOS. NOTE: Hyperthreading is a toggle setting that can execute multiple tasks simultaneously using...
... the documentation for your processor model. Options include: • Enabled (default) • Disabled 30 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Intel Hyperthreading Options NOTE: This option is supported through the system BIOS. NOTE: Hyperthreading is a toggle setting that can execute multiple tasks simultaneously using...
HP ROM-Based Setup Utility User Guide
Page 31
... performance for applications that benefit from higher performance cores rather than from additional processing cores • Addresses issues with software licensed on some G7 and Gen8 servers with enabling or disabling processor core count may exist. The Enhanced Processor Core Disable option allows you to specify the number of 2 System Options...
... performance for applications that benefit from higher performance cores rather than from additional processing cores • Addresses issues with software licensed on some G7 and Gen8 servers with enabling or disabling processor core count may exist. The Enhanced Processor Core Disable option allows you to specify the number of 2 System Options...