HP ROM-Based Setup Utility User Guide
Page 1
This document is embedded in the system ROM of all HP ProLiant Generation 2 through 8 servers (except the HP ProLiant DL580 Gen8 server). HP ROM-Based Setup Utility User Guide Abstract This document details how to access and use the HP ROM-Based Setup Utility that is for the person who installs, administers, and troubleshoots servers and storage systems. HP Part Number: 761393-001 Published: February 2014 Edition: 1 All options and available responses are defined.
This document is embedded in the system ROM of all HP ProLiant Generation 2 through 8 servers (except the HP ProLiant DL580 Gen8 server). HP ROM-Based Setup Utility User Guide Abstract This document details how to access and use the HP ROM-Based Setup Utility that is for the person who installs, administers, and troubleshoots servers and storage systems. HP Part Number: 761393-001 Published: February 2014 Edition: 1 All options and available responses are defined.
HP ROM-Based Setup Utility User Guide
Page 3
... Remote Console Mode...39 NUMLOCK Power-On State 41 SATA Controller Options (Gen8 servers with SATA controllers 42 Embedded SATA Configuration 42 Drive Write Cache...43 HP Smart Array B320i RAID Configuration 44 Power Management Options menu 45 HP Power Profile...45 HP Power Regulator...46 Redundant Power Supply Mode 47 Advanced Power Management Options...
... Remote Console Mode...39 NUMLOCK Power-On State 41 SATA Controller Options (Gen8 servers with SATA controllers 42 Embedded SATA Configuration 42 Drive Write Cache...43 HP Smart Array B320i RAID Configuration 44 Power Management Options menu 45 HP Power Profile...45 HP Power Regulator...46 Redundant Power Supply Mode 47 Advanced Power Management Options...
HP ROM-Based Setup Utility User Guide
Page 4
...Date and Time menu...77 Server Availability menu...78 ASR Status...78 ASR Timeout...79 Thermal Shutdown...80 Wake-On LAN...81 POST F1 Prompt...82 Power Button...83 Automatic Power-On (G7 servers 84 Automatic Power-On (Gen8 servers 85 Power-On Delay...86 Server Security menu...87 Set Power...-On Password...87 Set Admin Password...88 Network Server Mode...89 Intelligent Provisioning (F10 Prompt 90 Trusted Platform Module...91 TPM...
...Date and Time menu...77 Server Availability menu...78 ASR Status...78 ASR Timeout...79 Thermal Shutdown...80 Wake-On LAN...81 POST F1 Prompt...82 Power Button...83 Automatic Power-On (G7 servers 84 Automatic Power-On (Gen8 servers 85 Power-On Delay...86 Server Security menu...87 Set Power...-On Password...87 Set Admin Password...88 Network Server Mode...89 Intelligent Provisioning (F10 Prompt 90 Trusted Platform Module...91 TPM...
HP ROM-Based Setup Utility User Guide
Page 6
User Default Options...155 Utility Language menu (G5 through G7 servers 156 Utility Language menu (Gen8 servers 157 3 RBSU menu-driven interface, version 2.xx (G5 and earlier servers 158 RBSU main menu...158 System Options menu...158 Embedded Serial Port A...159 Embedded Serial Port B...160 Virtual Serial...Diskette Write Control...162 Diskette Boot Control...162 Advanced Memory Protection 163 USB Control...164 USB 2.0 EHCI Controller 164 Power Regulator for ProLiant 165 USB External Port Capability 166 Ultra Low Power State...167 PCI Devices menu...168 Standard Boot Order (IPL) menu 169 ...
User Default Options...155 Utility Language menu (G5 through G7 servers 156 Utility Language menu (Gen8 servers 157 3 RBSU menu-driven interface, version 2.xx (G5 and earlier servers 158 RBSU main menu...158 System Options menu...158 Embedded Serial Port A...159 Embedded Serial Port B...160 Virtual Serial...Diskette Write Control...162 Diskette Boot Control...162 Advanced Memory Protection 163 USB Control...164 USB 2.0 EHCI Controller 164 Power Regulator for ProLiant 165 USB External Port Capability 166 Ultra Low Power State...167 PCI Devices menu...168 Standard Boot Order (IPL) menu 169 ...
HP ROM-Based Setup Utility User Guide
Page 9
If the RBSU does not recognize a device, it assigns a generic label to display the proper marketing name for the HP ProLiant DL580 Gen8 server) include a configuration utility that may include: • Configuring system devices and installed options • Displaying system information ...screen. • To modify settings in the menu-driven interface vary slightly. The server automatically restarts. • To exit the CLI interface, enter the exit command. 1 Introduction Overview HP ProLiant Generation 2 through and modify settings in the menu-driven interface, use the keystrokes...
If the RBSU does not recognize a device, it assigns a generic label to display the proper marketing name for the HP ProLiant DL580 Gen8 server) include a configuration utility that may include: • Configuring system devices and installed options • Displaying system information ...screen. • To modify settings in the menu-driven interface vary slightly. The server automatically restarts. • To exit the CLI interface, enter the exit command. 1 Introduction Overview HP ProLiant Generation 2 through and modify settings in the menu-driven interface, use the keystrokes...
HP ROM-Based Setup Utility User Guide
Page 10
Using this guide RBSU is described as follows in this guide: • Chapter 1: "Introduction" (page 9) • Chapter 2: "RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers)" (page 11) • Chapter 3: "RBSU menu-driven interface, version 2.xx (G5 and earlier servers)" (page 158) • Chapter 4: "RBSU BIOS Serial Console (CLI)" (page 189) • Chapter 5: "RBSU configuration flows (manual and scripted)" (page 200) • Chapter 6: "ROM-based utilities" (page 205) 10 Introduction
Using this guide RBSU is described as follows in this guide: • Chapter 1: "Introduction" (page 9) • Chapter 2: "RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers)" (page 11) • Chapter 3: "RBSU menu-driven interface, version 2.xx (G5 and earlier servers)" (page 158) • Chapter 4: "RBSU BIOS Serial Console (CLI)" (page 189) • Chapter 5: "RBSU configuration flows (manual and scripted)" (page 200) • Chapter 6: "ROM-based utilities" (page 205) 10 Introduction
HP ROM-Based Setup Utility User Guide
Page 11
...main menu 11 2 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) NOTE: The RBSU for these G6 servers, see "RBSU menu-driven interface, version 2.xx (G5 and earlier servers)" (page 158). RBSU main menu In the RBSU main menu, the left-hand side of the... the feature. The following G6 servers do not use RBSU version 3.xx: • DL580 Gen8 • DL385 G6 • DL785 G6 • DL585 G6 For RBSU information for G6, G7, and Gen8 servers contain many of the screen, a window displays basic server information, including the server model, serial number, BIOS version...
...main menu 11 2 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) NOTE: The RBSU for these G6 servers, see "RBSU menu-driven interface, version 2.xx (G5 and earlier servers)" (page 158). RBSU main menu In the RBSU main menu, the left-hand side of the... the feature. The following G6 servers do not use RBSU version 3.xx: • DL580 Gen8 • DL385 G6 • DL785 G6 • DL585 G6 For RBSU information for G6, G7, and Gen8 servers contain many of the screen, a window displays basic server information, including the server model, serial number, BIOS version...
HP ROM-Based Setup Utility User Guide
Page 12
...State" (page 41) • "SATA Controller Options (Gen8 servers with SATA controllers)" (page 42) • "HP Smart Array B320i RAID Configuration" (page 44) Serial Port options Depending on the server model. 12 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) This setting may include: • "Embedded Serial ... and associated default resources to the selected physical serial port. System Options menu The System Options menu options control basic I/O server configuration. Depending on your server model, options may be overwritten by the operating system.
...State" (page 41) • "SATA Controller Options (Gen8 servers with SATA controllers)" (page 42) • "HP Smart Array B320i RAID Configuration" (page 44) Serial Port options Depending on the server model. 12 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) This setting may include: • "Embedded Serial ... and associated default resources to the selected physical serial port. System Options menu The System Options menu options control basic I/O server configuration. Depending on your server model, options may be overwritten by the operating system.
HP ROM-Based Setup Utility User Guide
Page 14
...the BIOS Serial Console and the OS serial console. For more information on iLO configurations, see the iLO user documentation on the server model. Virtual Serial Port The Virtual Serial Port option assigns the logical COM port number and associated default resources used by the ... 1 (default for blade servers) • COM 2 (default for all servers except blades) • COM 3 • Disabled NOTE: The COM ports listed and the default setting vary depending on the HP website (http://www.hp.com/go/ilo/docs). 14 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers)
...the BIOS Serial Console and the OS serial console. For more information on iLO configurations, see the iLO user documentation on the server model. Virtual Serial Port The Virtual Serial Port option assigns the logical COM port number and associated default resources used by the ... 1 (default for blade servers) • COM 2 (default for all servers except blades) • COM 3 • Disabled NOTE: The COM ports listed and the default setting vary depending on the HP website (http://www.hp.com/go/ilo/docs). 14 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers)
HP ROM-Based Setup Utility User Guide
Page 15
This Embedded Serial Port Connector option controls how the system uses the embedded front serial port. Embedded Serial Port Connector NOTE: This option is attached. • Front Serial Port-Disables auto-switching and always have the embedded serial port function via the front serial port when the SUV cable is not attached, but automatically switches to the SUV cable if it is available only on some Gen8 servers. System Options menu 15 Options include: • Automatically Switch to SUV Cable (default)-Functions via the front serial port.
This Embedded Serial Port Connector option controls how the system uses the embedded front serial port. Embedded Serial Port Connector NOTE: This option is attached. • Front Serial Port-Disables auto-switching and always have the embedded serial port function via the front serial port when the SUV cable is not attached, but automatically switches to the SUV cable if it is available only on some Gen8 servers. System Options menu 15 Options include: • Automatically Switch to SUV Cable (default)-Functions via the front serial port.
HP ROM-Based Setup Utility User Guide
Page 16
..., press any key to display the following settings: • Network Boot • Disabled 16 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) These settings provide no functionality if an embedded NIC is for embedded NICs. Embedded NICs These boot options enable or disable network boot for the... Network Boot support for an embedded NIC, the NIC will not show up in the Standard Boot Order (IPL) until the next reboot. • For Gen8 servers, this , the RBSU menu may offer a network boot option that does nothing.
..., press any key to display the following settings: • Network Boot • Disabled 16 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) These settings provide no functionality if an embedded NIC is for embedded NICs. Embedded NICs These boot options enable or disable network boot for the... Network Boot support for an embedded NIC, the NIC will not show up in the Standard Boot Order (IPL) until the next reboot. • For Gen8 servers, this , the RBSU menu may offer a network boot option that does nothing.
HP ROM-Based Setup Utility User Guide
Page 18
... Channel Mode" mode. (page 142). G7 servers: Some models Gen8 servers: Not an available option Lockstep Mode with Advanced ECC Support (Intel servers) Provides maximum data protection by a spare group of memory that would otherwise result in Advanced ECC see the HP ProLiant Server Memory website (http://h18004.www1.hp.com/products/servers/technology/memoryprotection.html). 18 RBSU menu...
... Channel Mode" mode. (page 142). G7 servers: Some models Gen8 servers: Not an available option Lockstep Mode with Advanced ECC Support (Intel servers) Provides maximum data protection by a spare group of memory that would otherwise result in Advanced ECC see the HP ProLiant Server Memory website (http://h18004.www1.hp.com/products/servers/technology/memoryprotection.html). 18 RBSU menu...
HP ROM-Based Setup Utility User Guide
Page 20
... USB Support removes the ability to display the available settings. 20 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Legacy USB Disabled also disables iLO3 virtual devices. After reading the warning message, press any key to use a USB keyboard and mouse in... a pre-boot environment. devices from mounting. G7 servers: AllGen8 servers: All All USB ports and embedded devices are disabled. External USB Port Disabled All external USB ports are disabled. RBSU cannot be used...
... USB Support removes the ability to display the available settings. 20 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Legacy USB Disabled also disables iLO3 virtual devices. After reading the warning message, press any key to use a USB keyboard and mouse in... a pre-boot environment. devices from mounting. G7 servers: AllGen8 servers: All All USB ports and embedded devices are disabled. External USB Port Disabled All external USB ports are disabled. RBSU cannot be used...
HP ROM-Based Setup Utility User Guide
Page 22
USB Boot Support controls whether the system boots from USB devices connected to the server. Options include: • Enabled (default) • Disabled 22 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) When disabled, this option also disables booting of iLO virtual media. USB Boot Support NOTE: This option is available on Gen8 servers.
USB Boot Support controls whether the system boots from USB devices connected to the server. Options include: • Enabled (default) • Disabled 22 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) When disabled, this option also disables booting of iLO virtual media. USB Boot Support NOTE: This option is available on Gen8 servers.
HP ROM-Based Setup Utility User Guide
Page 23
... DriveKeys First • External DriveKeys First (default) USB Drive Key Enumeration By default the BIOS enumerates a USB drive key and treats it is available on HP ProLiant Gen8 servers, except for the device. Removable Flash Media Boot Sequence This option enables the user to the pre-OS BIOS control of USB. Options include: •... to select which USB port or SD card slot the system searches first when enumerating boot devices. NOTE: This option is not enumerated for the HP ProLiant DL580 Gen8 server. When disabled it as a hard disk.
... DriveKeys First • External DriveKeys First (default) USB Drive Key Enumeration By default the BIOS enumerates a USB drive key and treats it is available on HP ProLiant Gen8 servers, except for the device. Removable Flash Media Boot Sequence This option enables the user to the pre-OS BIOS control of USB. Options include: •... to select which USB port or SD card slot the system searches first when enumerating boot devices. NOTE: This option is not enumerated for the HP ProLiant DL580 Gen8 server. When disabled it as a hard disk.
HP ROM-Based Setup Utility User Guide
Page 25
Processor Options Depending on your server model, options may include: • "No-Execute Memory Protection" (page 26) • "No-Execute Page Protection" (page 27) • "Intel Virtualization Technology" (page 28) • "... Core Disable (Intel Core Select)" (page 31) • "Processor Core Disable (AMD Core Select)" (page 33) • "Intel Turbo Boost Technology (Gen8 servers)" (page 34) • "Intel Turbo Boost Technology (G7 servers)" (page 35) • "AMD Core Performance Boost" (page 36) • "Intel VT-d" (page 37) • "AMD-Vi (IOMMU)" (page 38) System...
Processor Options Depending on your server model, options may include: • "No-Execute Memory Protection" (page 26) • "No-Execute Page Protection" (page 27) • "Intel Virtualization Technology" (page 28) • "... Core Disable (Intel Core Select)" (page 31) • "Processor Core Disable (AMD Core Select)" (page 33) • "Intel Turbo Boost Technology (Gen8 servers)" (page 34) • "Intel Turbo Boost Technology (G7 servers)" (page 35) • "AMD Core Performance Boost" (page 36) • "Intel VT-d" (page 37) • "AMD-Vi (IOMMU)" (page 38) System...
HP ROM-Based Setup Utility User Guide
Page 26
... Intel processors. When used in combination with an OS that supports this option. 26 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Viruses that protects systems against malicious code and viruses. No-Execute Memory Protection NOTE: This option is raised. Options include: • Enabled (default) • Disabled...
... Intel processors. When used in combination with an OS that supports this option. 26 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Viruses that protects systems against malicious code and viruses. No-Execute Memory Protection NOTE: This option is raised. Options include: • Enabled (default) • Disabled...
HP ROM-Based Setup Utility User Guide
Page 28
Intel Virtualization Technology NOTE: This option is available on servers with Intel processors. When enabled, a hypervisor supporting this feature can use extra hardware capabilities provided by Intel. Options include: • Enabled (default) • Disabled 28 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers)
Intel Virtualization Technology NOTE: This option is available on servers with Intel processors. When enabled, a hypervisor supporting this feature can use extra hardware capabilities provided by Intel. Options include: • Enabled (default) • Disabled 28 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers)
HP ROM-Based Setup Utility User Guide
Page 30
... Technology to be enabled or disabled. Options include: • Enabled (default) • Disabled 30 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Intel Hyperthreading Options NOTE: This option is available on all processors. The option is a toggle setting that can execute multiple tasks simultaneously using the shared...
... Technology to be enabled or disabled. Options include: • Enabled (default) • Disabled 30 RBSU menu-driven interface, version 3.xx or later (G6, G7, and Gen8 servers) Intel Hyperthreading Options NOTE: This option is available on all processors. The option is a toggle setting that can execute multiple tasks simultaneously using the shared...
HP ROM-Based Setup Utility User Guide
Page 31
... performance for applications that benefit from higher performance cores rather than from additional processing cores • Addresses issues with software licensed on some G7 and Gen8 servers with enabling or disabling processor core count may exist.