HP Insight Management Agents architecture for Windows servers
Page 18
...-Based Enterprise Management (WBEM) Providers offer an alternative to the SNMP-based Insight Agents for ProLiant 100-series servers Beginning with G6 servers, this support now includes the HP ProLiant 100 - It is a defined standard for system management. series servers. 18 Previously, ProLiant 100 - WBEM is intended as an alternative client-side management solution, the Insight Management Agents...
...-Based Enterprise Management (WBEM) Providers offer an alternative to the SNMP-based Insight Agents for ProLiant 100-series servers Beginning with G6 servers, this support now includes the HP ProLiant 100 - It is a defined standard for system management. series servers. 18 Previously, ProLiant 100 - WBEM is intended as an alternative client-side management solution, the Insight Management Agents...
Implementing Microsoft Windows Server 2008 Foundation on HP ProLiant servers
Page 6
... ProLiant server platforms that support Windows Server 2008 Foundation Server platform ProLiant DL servers: ProLiant DL120 G5 ROM family ROM date (minimum) 022 02/26/08 ProLiant DL320 G5p* W05 07/02/08 ProLiant DL320 G6 W07 04/01/09 ProLiant ML servers: ProLiant ML110 G5 015 07/22/08 ProLiant ML115 G5 018 06/03/08 ProLiant ML310 G5* W05 07/02/08 ProLiant ML310 G6* *HP...
... ProLiant server platforms that support Windows Server 2008 Foundation Server platform ProLiant DL servers: ProLiant DL120 G5 ROM family ROM date (minimum) 022 02/26/08 ProLiant DL320 G5p* W05 07/02/08 ProLiant DL320 G6 W07 04/01/09 ProLiant ML servers: ProLiant ML110 G5 015 07/22/08 ProLiant ML115 G5 018 06/03/08 ProLiant ML310 G5* W05 07/02/08 ProLiant ML310 G6* *HP...
Implementing Microsoft Windows Server 2008 Foundation on HP ProLiant servers
Page 7
..., utilities, and management agents optimized for ProLiant systems. The PSP is supported with Windows Server 2008 Foundation on the following ProLiant series servers: • ProLiant DL300 series servers • ProLiant ML300 series servers The HP ProLiant Easy Set-up CD is a predefined and tested bundle that the following ProLiant servers: • ProLiant DL100 G6 series servers • ProLiant ML100 G6 series servers To see information about supported configurations...
..., utilities, and management agents optimized for ProLiant systems. The PSP is supported with Windows Server 2008 Foundation on the following ProLiant series servers: • ProLiant DL300 series servers • ProLiant ML300 series servers The HP ProLiant Easy Set-up CD is a predefined and tested bundle that the following ProLiant servers: • ProLiant DL100 G6 series servers • ProLiant ML100 G6 series servers To see information about supported configurations...
ISS Technology Update Index
Page 1
...to access the appropriate section. ISS Technology Update Index of Articles This alphabetical Index lists the titles of articles published in Intel®-based HP ProLiant G6 2 servers Volume 8, Number 7 Volume 8, Number 5 November 2009 August 2009 E Effective data rate of SAS Technology 4 Volume 8, Number 6... firmware and software updates 7 Volume 7, Number 5 Volume 7, Number 5 May 2008 May 2008 Deploying VMware ESXi on HP ProLiant BL400 Series 5 Server Blades Disabling processor cores in the ISS Technology Update newsletter. If you find the desired article. If you know the ...
...to access the appropriate section. ISS Technology Update Index of Articles This alphabetical Index lists the titles of articles published in Intel®-based HP ProLiant G6 2 servers Volume 8, Number 7 Volume 8, Number 5 November 2009 August 2009 E Effective data rate of SAS Technology 4 Volume 8, Number 6... firmware and software updates 7 Volume 7, Number 5 Volume 7, Number 5 May 2008 May 2008 Deploying VMware ESXi on HP ProLiant BL400 Series 5 Server Blades Disabling processor cores in the ISS Technology Update newsletter. If you find the desired article. If you know the ...
ISS Technology Update Index
Page 3
... 8, Number 6 3 Volume 8, Number 7 3 Volume 7, Number 8 Publication date October 2009 November 2009 September 2008 Optimizing memory performance in ProLiant G6 Intel- 2 based servers Overview of Microsoft® Windows® Essential Server 7 Solutions P Performance, throughput and compatibility of HP 6 Gb/s 6 SAS drives PUE and DCE-useful metrics for overall data center 6 efficiency Q Quick tip: Configuring a redundant domain...
... 8, Number 6 3 Volume 8, Number 7 3 Volume 7, Number 8 Publication date October 2009 November 2009 September 2008 Optimizing memory performance in ProLiant G6 Intel- 2 based servers Overview of Microsoft® Windows® Essential Server 7 Solutions P Performance, throughput and compatibility of HP 6 Gb/s 6 SAS drives PUE and DCE-useful metrics for overall data center 6 efficiency Q Quick tip: Configuring a redundant domain...
ISS Technology Update Index
Page 4
... to Gigatransfers 6 Volume 8, Number 4 Three--phase power distribution in c7000 Enclosures 3 Volume 8, Number 3 U Unbuffered DDR-3 DIMMs are a cost-effective solution for 5 ProLiant G6 servers Volume 8, Number 4 Understanding and implementing Accelerated iSCSI on 3 HP ProLiant servers Volume 8, Number 5 Understanding and interpreting the SPECpower_ssj2008 2 benchmark Volume 8, Number 6 Understanding and interpreting the VMmark benchmark 1 Volume 8, Number 2 Use iLO Advanced...
... to Gigatransfers 6 Volume 8, Number 4 Three--phase power distribution in c7000 Enclosures 3 Volume 8, Number 3 U Unbuffered DDR-3 DIMMs are a cost-effective solution for 5 ProLiant G6 servers Volume 8, Number 4 Understanding and implementing Accelerated iSCSI on 3 HP ProLiant servers Volume 8, Number 5 Understanding and interpreting the SPECpower_ssj2008 2 benchmark Volume 8, Number 6 Understanding and interpreting the VMmark benchmark 1 Volume 8, Number 2 Use iLO Advanced...
ISS Technology Update Volume 8, Number 5
Page 1
... cores in Intel®-based HP ProLiant G6 servers 2 Understanding and implementing Accelerated iSCSI on HP ProLiant servers 3 Performance, throughput and compatibility of HP 6-Gb/s SAS drives 6 Meet the Expert-Eric Pope ...8 Contact us ...9 Recently published industry standard server technology papers Title URL Implementing Microsoft® Windows Server® 2008 Foundation on HP ProLiant servers http://h20000.www2.hp.com/bc/docs/support/SupportManual...
... cores in Intel®-based HP ProLiant G6 servers 2 Understanding and implementing Accelerated iSCSI on HP ProLiant servers 3 Performance, throughput and compatibility of HP 6-Gb/s SAS drives 6 Meet the Expert-Eric Pope ...8 Contact us ...9 Recently published industry standard server technology papers Title URL Implementing Microsoft® Windows Server® 2008 Foundation on HP ProLiant servers http://h20000.www2.hp.com/bc/docs/support/SupportManual...
ISS Technology Update Volume 8, Number 5
Page 2
... chosen and the configuration saved, it is slightly different. Processor Core Disable sub-menu from the RBSU on HP ProLiant 300 series G6 servers Note In entry level HP ProLiant servers, the RBSU interface is applied to disable individual cores within these features are configurable, letting system administrators tune ...all of the cores enabled. ISS Technology Update Volume 8, Number 5 Disabling processor cores in Intel®-based HP ProLiant G6 servers HP ProLiant G6 servers with only one core enabled, half of the cores enabled, or all of the processors installed in the system.
... chosen and the configuration saved, it is slightly different. Processor Core Disable sub-menu from the RBSU on HP ProLiant 300 series G6 servers Note In entry level HP ProLiant servers, the RBSU interface is applied to disable individual cores within these features are configurable, letting system administrators tune ...all of the cores enabled. ISS Technology Update Volume 8, Number 5 Disabling processor cores in Intel®-based HP ProLiant G6 servers HP ProLiant G6 servers with only one core enabled, half of the cores enabled, or all of the processors installed in the system.
ISS Technology Update Volume 8, Number 5
Page 3
... specific application environments, this article, visit: HP ROM-Based Setup Utility User Guide HP Virtual IT Center Technology and architecture of HP ProLiant 300-series G6 servers Technology and architecture of HP ProLiant 100-series G6 servers http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00191707/c00191707.pdf www.hp.com/go/g6 http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00502616...
... specific application environments, this article, visit: HP ROM-Based Setup Utility User Guide HP Virtual IT Center Technology and architecture of HP ProLiant 300-series G6 servers Technology and architecture of HP ProLiant 100-series G6 servers http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00191707/c00191707.pdf www.hp.com/go/g6 http://h20000.www2.hp.com/bc/docs/support/SupportManual/c 00502616...
ISS Technology Update Volume 8, Number 5
Page 5
... Documents‖ and enter the product name/number. HP Accelerated iSCSI Licensing Pack for Accelerated iSCSI is no longer required on the topics discussed in this article, the DL385 G5p, DL385 G6, DL360 G6, and DL380 G6 ProLiant servers are required to download Softpaqs for all compatible multifunction server adapters. As of the publication of this article...
... Documents‖ and enter the product name/number. HP Accelerated iSCSI Licensing Pack for Accelerated iSCSI is no longer required on the topics discussed in this article, the DL385 G5p, DL385 G6, DL360 G6, and DL380 G6 ProLiant servers are required to download Softpaqs for all compatible multifunction server adapters. As of the publication of this article...
ISS Technology Update Volume 8, Number 5
Page 7
...are introduced. Therefore, for these resources: Resource URL HP StorageWorks Modular Smart Arrays HP ProLiant Smart Array RAID controllers http://h18006.www1.hp.com/storage/disk_storage/msa_diskarrays/ index.html http://h18004.www1.hp.com/products/servers/proliantstorage/array controllers/index.html 7 MSAs then use SAS...better able to communicate with each drive is configured with 3-Gb/s drives on the topics discussed in the HP ProLiant G6 servers prepares the way for the next several generations of the existing 3-Gb/s SAS interface. ISS Technology Update Volume 8, Number 5...
...are introduced. Therefore, for these resources: Resource URL HP StorageWorks Modular Smart Arrays HP ProLiant Smart Array RAID controllers http://h18006.www1.hp.com/storage/disk_storage/msa_diskarrays/ index.html http://h18004.www1.hp.com/products/servers/proliantstorage/array controllers/index.html 7 MSAs then use SAS...better able to communicate with each drive is configured with 3-Gb/s drives on the topics discussed in the HP ProLiant G6 servers prepares the way for the next several generations of the existing 3-Gb/s SAS interface. ISS Technology Update Volume 8, Number 5...
ISS Technology Update Volume 8, Number 6
Page 1
.../c002573 45/c00257345.pdf Selecting power cords and jumper cables for use with HP http://h20000.www2.hp.com/bc/docs/support/SupportManual/c001307 ProLiant and BladeSystem servers, 3rd edition 29/c00130729.pdf Technologies in HP ProLiant G6 c-Class server blades with http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018745 AMD Opteron™ processors 75/c01874575.pdf...
.../c002573 45/c00257345.pdf Selecting power cords and jumper cables for use with HP http://h20000.www2.hp.com/bc/docs/support/SupportManual/c001307 ProLiant and BladeSystem servers, 3rd edition 29/c00130729.pdf Technologies in HP ProLiant G6 c-Class server blades with http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018745 AMD Opteron™ processors 75/c01874575.pdf...
ISS Technology Update Volume 8, Number 6
Page 2
... have become important. The benchmark harness is supported by its power consumption. SPECpower_ssj2008 workload SPECpower_ssj2008 uses a server side Java (ssj) workload to generate work for the HP ProLiant DL385 G6 are measured at eleven different levels of server utilization for a fixed period of operating conditions. SPEC is a program that receives power data electronically without human...
... have become important. The benchmark harness is supported by its power consumption. SPECpower_ssj2008 workload SPECpower_ssj2008 uses a server side Java (ssj) workload to generate work for the HP ProLiant DL385 G6 are measured at eleven different levels of server utilization for a fixed period of operating conditions. SPEC is a program that receives power data electronically without human...
ISS Technology Update, Volume 8, Number 3
Page 7
... to focus on other platform teams through HP iLO (Onboard Administrator) is well protected by the other design activities. According to his manager, Jeoff Krontz, "Wayne's involvement with TAC yielded excellent customer feedback that the ability of ProLiant G6 servers to dynamically balance power efficiency with Industry Standard Servers (ISS) for getting the Common Design...
... to focus on other platform teams through HP iLO (Onboard Administrator) is well protected by the other design activities. According to his manager, Jeoff Krontz, "Wayne's involvement with TAC yielded excellent customer feedback that the ability of ProLiant G6 servers to dynamically balance power efficiency with Industry Standard Servers (ISS) for getting the Common Design...
ISS Technology Update, Volume 8, Number 4
Page 1
.../docs/support/SupportManual/c016395 94/c01639594.pdf Implementing Microsoft Windows Server 2008 Hyper-V™ http://h20000.www2.hp.com/bc/docs/support/SupportManual/c015161 on HP ProLiant servers integration note 56/c01516156.pdf Technology and architecture of HP ProLiant 100-series G6 (Generation 6) servers technology brief http://h20000.www2.hp.com/bc/docs/support/SupportManual/c017517 18/c01751718.pdf Implementing...
.../docs/support/SupportManual/c016395 94/c01639594.pdf Implementing Microsoft Windows Server 2008 Hyper-V™ http://h20000.www2.hp.com/bc/docs/support/SupportManual/c015161 on HP ProLiant servers integration note 56/c01516156.pdf Technology and architecture of HP ProLiant 100-series G6 (Generation 6) servers technology brief http://h20000.www2.hp.com/bc/docs/support/SupportManual/c017517 18/c01751718.pdf Implementing...
ISS Technology Update, Volume 8, Number 4
Page 2
ISS Technology Update Volume 8, Number 4 Optimizing memory performance in ProLiant G6 Intel-based servers To achieve higher performance and better efficiency, the new HP ProLiant G6 servers featuring the Intel® Nehalem architecture use of fully buffered DIMMs. This solved the ...is significantly different than previous generations of memory costs and power consumption. Comparing traditional and non-uniform memory architecture In traditional server memory architecture, memory controllers are part of the front-side bus. Overall bandwidth between processors as well as a Uniform...
ISS Technology Update Volume 8, Number 4 Optimizing memory performance in ProLiant G6 Intel-based servers To achieve higher performance and better efficiency, the new HP ProLiant G6 servers featuring the Intel® Nehalem architecture use of fully buffered DIMMs. This solved the ...is significantly different than previous generations of memory costs and power consumption. Comparing traditional and non-uniform memory architecture In traditional server memory architecture, memory controllers are part of the front-side bus. Overall bandwidth between processors as well as a Uniform...
ISS Technology Update, Volume 8, Number 4
Page 3
... is actually where the 10600 in PC3-10600 comes from, representing the maximum throughput for the DIMM in G6 servers With Intel Nehalem architecture, each transfer consists of the Processor/Memory complex for a 2P ProLiant G6 system with NUMA Volume 8, Number 4 Understanding and optimizing memory performance in round numbers. Figure 1-3 shows both a physical and...
... is actually where the 10600 in PC3-10600 comes from, representing the maximum throughput for the DIMM in G6 servers With Intel Nehalem architecture, each transfer consists of the Processor/Memory complex for a 2P ProLiant G6 system with NUMA Volume 8, Number 4 Understanding and optimizing memory performance in round numbers. Figure 1-3 shows both a physical and...
ISS Technology Update, Volume 8, Number 4
Page 4
...bandwidth can be achieved. When configuring ProLiant G6 Intel-based servers, observing the following general rules should not adversely affect memory throughput. However, mixing DIMM SKUs across the memory channels of a processor (for example, three of HP ProLiant Intel-based G6 system with 2 processors and 12 ..., the processors' memory controllers can help maximize system throughput. Logical block diagram of the same DIMMs in an HP ProLiant Intel-based G6 system with one DIMM. When installing memory on a 2P system, keep memory balanced across memory channels in groups...
...bandwidth can be achieved. When configuring ProLiant G6 Intel-based servers, observing the following general rules should not adversely affect memory throughput. However, mixing DIMM SKUs across the memory channels of a processor (for example, three of HP ProLiant Intel-based G6 system with 2 processors and 12 ..., the processors' memory controllers can help maximize system throughput. Logical block diagram of the same DIMMs in an HP ProLiant Intel-based G6 system with one DIMM. When installing memory on a 2P system, keep memory balanced across memory channels in groups...
ISS Technology Update, Volume 8, Number 4
Page 5
...GB *Maximum speed for quad-rank RDIMMs is limited to reach the maximum capacity of latency. Comparison between UDIMMs and RDIMMs in HP ProLiant G6 servers Table head UDIMMs RDIMMs Maximum speed supported DDR3-1333 DDR3-1333* Ranks per DIMM 1 or 2 1, 2, or 4 Maximum... the topics discussed in a system. RDIMMs are a cost-effective solution for ProLiant G6 servers HP ProLiant G6 servers support Double Data Rate-3 (DDR-3) Synchronous Dynamic Random Access Memory (SDRAM) technology. Select ProLiant G6 servers support both RDIMMs and UDIMMs; UDIMMs use less power and cost less than ...
...GB *Maximum speed for quad-rank RDIMMs is limited to reach the maximum capacity of latency. Comparison between UDIMMs and RDIMMs in HP ProLiant G6 servers Table head UDIMMs RDIMMs Maximum speed supported DDR3-1333 DDR3-1333* Ranks per DIMM 1 or 2 1, 2, or 4 Maximum... the topics discussed in a system. RDIMMs are a cost-effective solution for ProLiant G6 servers HP ProLiant G6 servers support Double Data Rate-3 (DDR-3) Synchronous Dynamic Random Access Memory (SDRAM) technology. Select ProLiant G6 servers support both RDIMMs and UDIMMs; UDIMMs use less power and cost less than ...
ISS Technology Update, Volume 8, Number 4
Page 6
... per link to transfer data, and it currently supports data rates up to -Point link-based architectures AMD Opteron ™ based HP ProLiant servers and Intel® Microarchitecture Nehalem-based HP ProLiant Generation 6 (G6) servers have bi-directional links that are attached to it supports data rates up to Intel QuickPath Technology HyperTransport (HT) Consortium homepage URL...
... per link to transfer data, and it currently supports data rates up to -Point link-based architectures AMD Opteron ™ based HP ProLiant servers and Intel® Microarchitecture Nehalem-based HP ProLiant Generation 6 (G6) servers have bi-directional links that are attached to it supports data rates up to Intel QuickPath Technology HyperTransport (HT) Consortium homepage URL...