Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 10
HP ProLiant Support Pack for the HP ProLiant and HP BladeSystem infrastructure deploys, monitors, and manages Windows Server 2008 servers. Also the HP Rapid Deployment Pack (RDP) can be managed by HP Systems Insight Manager (HP SIM) if the ...management agents are not supported. Supported in the Fibre Channel configuration only. MSA500 G2 packaged clusters are installed on the Windows Server 2008 operating system. Users should review the quickspecs for each management software product to add support for installation and operation on the server. For example, ProLiant...
HP ProLiant Support Pack for the HP ProLiant and HP BladeSystem infrastructure deploys, monitors, and manages Windows Server 2008 servers. Also the HP Rapid Deployment Pack (RDP) can be managed by HP Systems Insight Manager (HP SIM) if the ...management agents are not supported. Supported in the Fibre Channel configuration only. MSA500 G2 packaged clusters are installed on the Windows Server 2008 operating system. Users should review the quickspecs for each management software product to add support for installation and operation on the server. For example, ProLiant...
Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 8
... larger • A compatible battery pack or capacitor pack To obtain these tasks, see the SAAP QuickSpecs on demand To access SAAP features, you must purchase a license key from HP. When activated with ACU (on page 41) Some SAAP features are required for advanced configuration tasks... in offline mode • Drive Erase • Performance optimization for advanced configuration tasks (on the HP website (http://www.hp.com/go/SAAP). HP Smart Array Advanced Pack 8 To obtain a license key, see the SAAP product page on page 6)." For a list ...
... larger • A compatible battery pack or capacitor pack To obtain these tasks, see the SAAP QuickSpecs on demand To access SAAP features, you must purchase a license key from HP. When activated with ACU (on page 41) Some SAAP features are required for advanced configuration tasks... in offline mode • Drive Erase • Performance optimization for advanced configuration tasks (on the HP website (http://www.hp.com/go/SAAP). HP Smart Array Advanced Pack 8 To obtain a license key, see the SAAP product page on page 6)." For a list ...
HP ROM-Based Setup Utility User Guide
Page 57
... feature controls PCIe Generation 1 or PCIe Generation 2 support and can be used to work around issues with AMD processors. In addition, this option, see the QuickSpecs and user documentation for all expansion cards. Power Management Options menu 57 PCI Express Generation 2.0 Support NOTE: This option is forced to PCIe Generation 2. Options...
... feature controls PCIe Generation 1 or PCIe Generation 2 support and can be used to work around issues with AMD processors. In addition, this option, see the QuickSpecs and user documentation for all expansion cards. Power Management Options menu 57 PCI Express Generation 2.0 Support NOTE: This option is forced to PCIe Generation 2. Options...
HP ROM-Based Setup Utility User Guide
Page 130
For more information, see the user guide or QuickSpecs for the server. 130 RBSU menu-driven interface (G7 and later servers) Memory Channel Mode NOTE: This option is available on Gen8 servers with Intel ...
For more information, see the user guide or QuickSpecs for the server. 130 RBSU menu-driven interface (G7 and later servers) Memory Channel Mode NOTE: This option is available on Gen8 servers with Intel ...
HP Intelligent Provisioning 1.30 Release Notes
Page 3
... including support information, enhancements, and known issues and their potential workarounds. supported on Single Socket Servers, check server QuickSpecs • Microsoft Windows Server 2008 Standard, Enterprise, Small Business Server 2008 • Microsoft Windows Server 2008 Standard ...20 Product models Intelligent Provisioning supports HP ProLiant Gen8 servers. Operating systems and devices NOTE: Intelligent Provisioning does not support all HP ProLiant Gen8 servers. HP ProLiant SL and SE servers do not ship with previous generation HP ProLiant servers. Version: 1.30 Description ...
... including support information, enhancements, and known issues and their potential workarounds. supported on Single Socket Servers, check server QuickSpecs • Microsoft Windows Server 2008 Standard, Enterprise, Small Business Server 2008 • Microsoft Windows Server 2008 Standard ...20 Product models Intelligent Provisioning supports HP ProLiant Gen8 servers. Operating systems and devices NOTE: Intelligent Provisioning does not support all HP ProLiant Gen8 servers. HP ProLiant SL and SE servers do not ship with previous generation HP ProLiant servers. Version: 1.30 Description ...
HP ProLiant Gen8 Troubleshooting Guide Volume I: Troubleshooting
Page 4
...system boot problems flowchart 34 Fault indications flowchart...35 Hardware problems ...38 Procedures for all ProLiant servers ...38 Power problems ...38 Power source problems ...38 Power supply problems ...39 ...43 Storage problems ...46 SD and MicroSD card problems ...46 USB drive key problems ...46 Fan problems...47 HP Trusted Platform Module problems 48 Memory problems ...48 Processor problems ...50 Tape drive problems...51 Graphics and video ...Boot problems...63 Software tools and solutions ...65 Server mode ...65 Product QuickSpecs...65 HP iLO Management Engine ...65 HP iLO ...65 Contents 4
...system boot problems flowchart 34 Fault indications flowchart...35 Hardware problems ...38 Procedures for all ProLiant servers ...38 Power problems ...38 Power source problems ...38 Power supply problems ...39 ...43 Storage problems ...46 SD and MicroSD card problems ...46 USB drive key problems ...46 Fan problems...47 HP Trusted Platform Module problems 48 Memory problems ...48 Processor problems ...50 Tape drive problems...51 Graphics and video ...Boot problems...63 Software tools and solutions ...65 Server mode ...65 Product QuickSpecs...65 HP iLO Management Engine ...65 HP iLO ...65 Contents 4
HP ProLiant Gen8 Troubleshooting Guide Volume I: Troubleshooting
Page 5
... control and proactive notification 77 HP Insight Management Agents ...77 HP resources for troubleshooting 78 Online resources ...78 HP Support Center website...78 HP Guided Troubleshooting website 78 Troubleshooting resources for previous HP ProLiant server models 78 Server blade enclosure troubleshooting resources 78 Error message resources ...78 Server documentation ...79 HP product QuickSpecs ...79 White papers ...79 Service...
... control and proactive notification 77 HP Insight Management Agents ...77 HP resources for troubleshooting 78 Online resources ...78 HP Support Center website...78 HP Guided Troubleshooting website 78 Troubleshooting resources for previous HP ProLiant server models 78 Server blade enclosure troubleshooting resources 78 Error message resources ...78 Server documentation ...79 HP product QuickSpecs ...79 White papers ...79 Service...
HP ProLiant Gen8 Troubleshooting Guide Volume I: Troubleshooting
Page 42
... or similar design If the board works in the server documentation. CAUTION: Before removing or replacing any of the problem. For more information, see the HP product QuickSpecs (on page 79). CAUTION: Clearing NVRAM deletes the configuration information. For more information on which PCIe technology is the only device on a bus, be...
... or similar design If the board works in the server documentation. CAUTION: Before removing or replacing any of the problem. For more information, see the HP product QuickSpecs (on page 79). CAUTION: Clearing NVRAM deletes the configuration information. For more information on which PCIe technology is the only device on a bus, be...
HP ProLiant Gen8 Troubleshooting Guide Volume I: Troubleshooting
Page 44
...4. Run ACU ("Array Configuration Utility" on page 68). For more information, see the server documentation or the HP website (http://www.hp.com). 6. Run Insight Diagnostics ("HP Insight Diagnostics" on page 68) and replace failed components as indicated. 11. Be sure no loose connections (on...failed drive. 8. Power cycle the server. For information on drive LEDs, see the server QuickSpecs on page 18)." To determine drive support, see "Drive LED definitions (on the HP website (http://www.hp.com/go /SAAP). Hardware problems 44 o Expander backplane SEP firmware o System ROM 3....
...4. Run ACU ("Array Configuration Utility" on page 68). For more information, see the server documentation or the HP website (http://www.hp.com). 6. Run Insight Diagnostics ("HP Insight Diagnostics" on page 68) and replace failed components as indicated. 11. Be sure no loose connections (on...failed drive. 8. Power cycle the server. For information on drive LEDs, see the server QuickSpecs on page 18)." To determine drive support, see "Drive LED definitions (on the HP website (http://www.hp.com/go /SAAP). Hardware problems 44 o Expander backplane SEP firmware o System ROM 3....
HP ProLiant Gen8 Troubleshooting Guide Volume I: Troubleshooting
Page 65
... deployment through ongoing management. This design makes HP iLO independent of selected HP ProLiant servers that simplifies initial server setup, server health monitoring, power and thermal optimization, and remote server administration. The HP iLO subsystem includes an intelligent microprocessor, secure ...Offline Online and Offline Offline Offline Product QuickSpecs For more information about product features, specifications, options, configurations, and compatibility, see the product QuickSpecs on the HP Product Bulletin website (http://www.hp.com/go/productbulletin). Software tools and ...
... deployment through ongoing management. This design makes HP iLO independent of selected HP ProLiant servers that simplifies initial server setup, server health monitoring, power and thermal optimization, and remote server administration. The HP iLO subsystem includes an intelligent microprocessor, secure ...Offline Online and Offline Offline Offline Product QuickSpecs For more information about product features, specifications, options, configurations, and compatibility, see the product QuickSpecs on the HP Product Bulletin website (http://www.hp.com/go/productbulletin). Software tools and ...
HP ProLiant Gen8 Troubleshooting Guide Volume I: Troubleshooting
Page 79
... the latest product information, driver updates, software changes, and other notifications. Subscriber's choice for business HP's Subscriber's Choice is the set of upcoming hardware and software changes on the HP Product Bulletin website (http://www.hp.com/go/productbulletin). HP product QuickSpecs For more information about product features, specifications, options, configurations, and compatibility, see the...
... the latest product information, driver updates, software changes, and other notifications. Subscriber's choice for business HP's Subscriber's Choice is the set of upcoming hardware and software changes on the HP Product Bulletin website (http://www.hp.com/go/productbulletin). HP product QuickSpecs For more information about product features, specifications, options, configurations, and compatibility, see the...
HP ProLiant Gen8 Troubleshooting Guide Volume I: Troubleshooting
Page 80
... features, see the HP website (http://www.hp.com/services/proliant) or the HP website for fast problem identification and resolution. Provides 24x7 secure remote monitoring, diagnosis and problem resolution. HP resources for your behalf. For more information, see the Product QuickSpecs on the HP website (http://www.hp.com/go/productbulletin). HP Technology Service Portfolio HP Technology Services offers...
... features, see the HP website (http://www.hp.com/services/proliant) or the HP website for fast problem identification and resolution. Provides 24x7 secure remote monitoring, diagnosis and problem resolution. HP resources for your behalf. For more information, see the Product QuickSpecs on the HP website (http://www.hp.com/go/productbulletin). HP Technology Service Portfolio HP Technology Services offers...
HP ProLiant Gen8 Troubleshooting Guide Volume I: Troubleshooting
Page 81
...QuickSpecs on the HP website (http://www.hp.com/go/hpsc). Printed notices are electronic documentation on the HP website (http://www.hp.com/go /hpsc) Teardown or removal and replacement procedure videos For more information about removal and replacement procedures for HP BladeSystem documentation) • HP...: • Documentation CD that ships with the server • Documentation CD that ships with the enclosure (for HP ProLiant servers, see the HP Power Advisor on complex technical topics. See one of the following locations: • Documentation CD that ships with ...
...QuickSpecs on the HP website (http://www.hp.com/go/hpsc). Printed notices are electronic documentation on the HP website (http://www.hp.com/go /hpsc) Teardown or removal and replacement procedure videos For more information about removal and replacement procedures for HP BladeSystem documentation) • HP...: • Documentation CD that ships with the server • Documentation CD that ships with the enclosure (for HP ProLiant servers, see the HP Power Advisor on complex technical topics. See one of the following locations: • Documentation CD that ships with ...
HP ProLiant Gen8 Troubleshooting Guide Volume I: Troubleshooting
Page 100
... 14, 50, 51 processor tool 14 product configuration resources 80 product features 65 Product ID 72 product information resources 79, 80 product installation resources 80 Q QuickSpecs 65, 79, 80, 81 R rack stability 11 rack warnings 11 RBSU (ROM-Based Setup Utility) 43, 65, 71, 72 RBSU configuration 71 read/write issue...
... 14, 50, 51 processor tool 14 product configuration resources 80 product features 65 Product ID 72 product information resources 79, 80 product installation resources 80 Q QuickSpecs 65, 79, 80, 81 R rack stability 11 rack warnings 11 RBSU (ROM-Based Setup Utility) 43, 65, 71, 72 RBSU configuration 71 read/write issue...
HP ProLiant DL320e Gen8 Server User Guide
Page 4
...38 Installing a storage controller ...38 Installing the FBWC module and capacitor pack 39 Optical drive option ...41 Memory options ...44 HP SmartMemory ...45 DIMM identification ...45 Single-rank and dual-rank DIMMs ...46 Memory subsystem architecture ...46 General DIMM slot population guidelines... utilities 62 Server mode ...62 Server QuickSpecs ...62 HP iLO Management Engine ...62 HP iLO ...62 Intelligent Provisioning...64 HP Insight Remote Support software 66 Scripting Toolkit ...66 HP Service Pack for ProLiant ...67 HP Smart Update Manager...67 HP ROM-Based Setup Utility ...67 Using RBSU...
...38 Installing a storage controller ...38 Installing the FBWC module and capacitor pack 39 Optical drive option ...41 Memory options ...44 HP SmartMemory ...45 DIMM identification ...45 Single-rank and dual-rank DIMMs ...46 Memory subsystem architecture ...46 General DIMM slot population guidelines... utilities 62 Server mode ...62 Server QuickSpecs ...62 HP iLO Management Engine ...62 HP iLO ...62 Intelligent Provisioning...64 HP Insight Remote Support software 66 Scripting Toolkit ...66 HP Service Pack for ProLiant ...67 HP Smart Update Manager...67 HP ROM-Based Setup Utility ...67 Using RBSU...
HP ProLiant DL320e Gen8 Server User Guide
Page 38
...preserved data to 4 hours. For more information about the controller and its features, see the HP Dynamic Smart Array RAID Controller User Guide on the HP website (http://www.hp.com/support/CASAC_RG_en). Also, do not remove the cable from the cache module. If the amber...on HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support/DSA_RAID_UG_en). IMPORTANT: The capacitor pack might take up the server (on the HP website (http://www.hp.com/support). 16. To configure arrays, see the QuickSpecs on page 17). Installing a storage controller HP recommends...
...preserved data to 4 hours. For more information about the controller and its features, see the HP Dynamic Smart Array RAID Controller User Guide on the HP website (http://www.hp.com/support/CASAC_RG_en). Also, do not remove the cable from the cache module. If the amber...on HP Smart Array Controllers Reference Guide on the HP website (http://www.hp.com/support/DSA_RAID_UG_en). IMPORTANT: The capacitor pack might take up the server (on the HP website (http://www.hp.com/support). 16. To configure arrays, see the QuickSpecs on page 17). Installing a storage controller HP recommends...
HP ProLiant DL320e Gen8 Server User Guide
Page 39
... rack (on page 55)." 7. Connect each power cord from the server. 3. For more information on page 32). Upgrade options exist for HP ProLiant Servers User Guide on page 17). To install the component: 1. b. Disconnect each power cord to the server. 11. Connect each power ...page 18). 4. Taking this precaution ensures that the server is powered up . For internal cable routing information in different drive configuration, see the QuickSpecs on page 20). 8. Disconnect each power cord from the power source. o Remove the server from the rack (on page 28). 9. ...
... rack (on page 55)." 7. Connect each power cord from the server. 3. For more information on page 32). Upgrade options exist for HP ProLiant Servers User Guide on page 17). To install the component: 1. b. Disconnect each power cord to the server. 11. Connect each power ...page 18). 4. Taking this precaution ensures that the server is powered up . For internal cable routing information in different drive configuration, see the QuickSpecs on page 20). 8. Disconnect each power cord from the power source. o Remove the server from the rack (on page 28). 9. ...
HP ProLiant DL320e Gen8 Server User Guide
Page 46
For the DIMM slot locations, see the QuickSpecs on page 11)." Hardware options installation 46 The server memory control subsystem selects the proper rank within the DIMM when writing to or reading from... DIMMs provide the greatest capacity with ECC) L = LRDIMM (load reduced) For the latest supported memory information, see "DIMM slot locations (on the HP website (http://h18000.www1.hp.com/products/quickspecs/ProductBulletin.html). Letters identify the population order. Item Description 3 Data width 4 Voltage rating 5 Memory speed 6 DIMM type Definition x4 = 4-bit x8 = 8-bit...
For the DIMM slot locations, see the QuickSpecs on page 11)." Hardware options installation 46 The server memory control subsystem selects the proper rank within the DIMM when writing to or reading from... DIMMs provide the greatest capacity with ECC) L = LRDIMM (load reduced) For the latest supported memory information, see "DIMM slot locations (on the HP website (http://h18000.www1.hp.com/products/quickspecs/ProductBulletin.html). Letters identify the population order. Item Description 3 Data width 4 Voltage rating 5 Memory speed 6 DIMM type Definition x4 = 4-bit x8 = 8-bit...
HP ProLiant DL320e Gen8 Server User Guide
Page 62
... iLO subsystem includes an intelligent microprocessor, secure memory, and a dedicated network interface. This design makes iLO independent of selected HP ProLiant servers that simplifies initial server setup, server health monitoring, power and thermal optimization, and remote server administration. Software and configuration utilities 62... and Offline Online Offline Online Online and Offline Online and Offline Offline Online and Offline Offline Offline Server QuickSpecs For more information about product features, specifications, options, configurations, and compatibility, see the...
... iLO subsystem includes an intelligent microprocessor, secure memory, and a dedicated network interface. This design makes iLO independent of selected HP ProLiant servers that simplifies initial server setup, server health monitoring, power and thermal optimization, and remote server administration. Software and configuration utilities 62... and Offline Online Offline Online Online and Offline Online and Offline Offline Online and Offline Offline Offline Server QuickSpecs For more information about product features, specifications, options, configurations, and compatibility, see the...