HP ProLiant Intel-based 100-series G6 server technology
Page 3
...G6 servers. The Xeon 5500 Series microarchitecture is built on hafnium-based, 45 nanometer high-k metal gate silicon technology to reduce electrical leakage. Exceptions are listed in all ProLiant 100-series servers, see the HP technology brief titled "The Intel processor roadmap for industry-standard servers": http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00164255/c00164255.pdf... components • "Right Size" Common Slot power supplies in Intel-based HP ProLiant 100-series G6 servers. These small, energy-efficient, high-performance processors support distributed shared memory, ...
...G6 servers. The Xeon 5500 Series microarchitecture is built on hafnium-based, 45 nanometer high-k metal gate silicon technology to reduce electrical leakage. Exceptions are listed in all ProLiant 100-series servers, see the HP technology brief titled "The Intel processor roadmap for industry-standard servers": http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00164255/c00164255.pdf... components • "Right Size" Common Slot power supplies in Intel-based HP ProLiant 100-series G6 servers. These small, energy-efficient, high-performance processors support distributed shared memory, ...
HP ProLiant Intel-based 100-series G6 server technology
Page 10
...The OS does not revert to provide an even higher level of system memory technologies" at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00256987/c00256987.pdf. 10 This alternate routing decreases memory access latency and increases performance. Memory Mirroring with DDR-3, the two memory... to obtain the correct data. The third memory channel must be enabled in 64-byte chunks. To implement mirroring with DDR-3 ProLiant 100-series G6 servers using the Xeon 5500 Series processor. In three-channel memory systems, the third channel is still protected by means of a single...
...The OS does not revert to provide an even higher level of system memory technologies" at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00256987/c00256987.pdf. 10 This alternate routing decreases memory access latency and increases performance. Memory Mirroring with DDR-3, the two memory... to obtain the correct data. The third memory channel must be enabled in 64-byte chunks. To implement mirroring with DDR-3 ProLiant 100-series G6 servers using the Xeon 5500 Series processor. In three-channel memory systems, the third channel is still protected by means of a single...
HP ProLiant Intel-based 100-series G6 server technology
Page 11
... fix disk failures. PCIe 2.0 has a per -lane signaling rate of clock skew and signal degradation at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01613420/c01613420.pdf . 11 A PCIe 2.0 device can be used in a PCIe 1.0 slot and a PCIe 1.0 device can be used ... rates Lane 1 Send Lane 1 Receive Source Lane n Send Lane n Receive Target Link size x1 x4 x8 x16 Max. PCI Express technology All ProLiant G6 servers support the PCIe 2.0 specification. More importantly, SAS architecture solves the parallel SCSI problems of PCIe 1.0 (Figure 4). Table 3. Table 3 shows the level...
... fix disk failures. PCIe 2.0 has a per -lane signaling rate of clock skew and signal degradation at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01613420/c01613420.pdf . 11 A PCIe 2.0 device can be used in a PCIe 1.0 slot and a PCIe 1.0 device can be used ... rates Lane 1 Send Lane 1 Receive Source Lane n Send Lane n Receive Target Link size x1 x4 x8 x16 Max. PCI Express technology All ProLiant G6 servers support the PCIe 2.0 specification. More importantly, SAS architecture solves the parallel SCSI problems of PCIe 1.0 (Figure 4). Table 3. Table 3 shows the level...
HP ProLiant Intel-based 100-series G6 server technology
Page 13
... protects against failure of up to 48 hours before recharging is not available on the ProLiant DL160, DL170h, DL180, and ML150 G6 servers, the B110i features an OS-specific driver from HP that can significantly increase performance. During the expansion, the BBWC preserves data and logical... key for the B110i SATA Software RAID, download the B110i user guide at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01706551/c01706551.pdf Smart Array Advanced Pack HP Smart Array Advanced Pack (SAAP) firmware provides advanced functionality within Smart Array controllers. Battery backed ...
... protects against failure of up to 48 hours before recharging is not available on the ProLiant DL160, DL170h, DL180, and ML150 G6 servers, the B110i features an OS-specific driver from HP that can significantly increase performance. During the expansion, the BBWC preserves data and logical... key for the B110i SATA Software RAID, download the B110i user guide at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01706551/c01706551.pdf Smart Array Advanced Pack HP Smart Array Advanced Pack (SAAP) firmware provides advanced functionality within Smart Array controllers. Battery backed ...
HP ProLiant Intel-based 100-series G6 server technology
Page 28
...-3 Memory Configuration Tool SAS and SATA technology Smart Array Advance Pack Smart Array controllers HP Network Adapters for ProLiant DL and ML Servers HP ProLiant 100-series Easy Set-up CDs HP ProLiant DL120 G6 Server HP ProLiant DL160 G6 Server HP ProLiant DL180 G6 Server HP ProLiant ML110 G6 Server HP ProLiant ML150 G6 Server HP ProLiant DL170h G6 Server overview HP ProLiant DL1000 G6 Multi Node Server HP ProLiant Onboard Administrator Powered by LO100 (remote management) ISS Technology Communications briefs: Memory technology evolution...
...-3 Memory Configuration Tool SAS and SATA technology Smart Array Advance Pack Smart Array controllers HP Network Adapters for ProLiant DL and ML Servers HP ProLiant 100-series Easy Set-up CDs HP ProLiant DL120 G6 Server HP ProLiant DL160 G6 Server HP ProLiant DL180 G6 Server HP ProLiant ML110 G6 Server HP ProLiant ML150 G6 Server HP ProLiant DL170h G6 Server overview HP ProLiant DL1000 G6 Multi Node Server HP ProLiant Onboard Administrator Powered by LO100 (remote management) ISS Technology Communications briefs: Memory technology evolution...
HP Power Advisor utility: a tool for estimating power requirements for HP ProLiant server systems
Page 15
... Figure 13. 42U rack configuration of HP ProLiant DL380 G6 servers with redundant power buses Physical Configuration 40A PDU DL380 G6 servers 1 thru 10 Functional Block Diagram PS A PS B DL380 G6 servers 1 thru 10 PS A PS B 40A PDU 27.6 A DL380 G6 servers 11 thru 20 13.8 A DL380 G6 servers 11 thru 20 13.8 A Bus A... Figure 13, the 40-amp PDUs are required and provide headroom for IT Professionals" at http://h20000.www2.hp.com/bc/docs/support/SupportManual/ c01234421/c01234421.pdf 15 For this reason, a PDU on a redundant power bus should fail. Figure 13 shows a rack ...
... Figure 13. 42U rack configuration of HP ProLiant DL380 G6 servers with redundant power buses Physical Configuration 40A PDU DL380 G6 servers 1 thru 10 Functional Block Diagram PS A PS B DL380 G6 servers 1 thru 10 PS A PS B 40A PDU 27.6 A DL380 G6 servers 11 thru 20 13.8 A DL380 G6 servers 11 thru 20 13.8 A Bus A... Figure 13, the 40-amp PDUs are required and provide headroom for IT Professionals" at http://h20000.www2.hp.com/bc/docs/support/SupportManual/ c01234421/c01234421.pdf 15 For this reason, a PDU on a redundant power bus should fail. Figure 13 shows a rack ...
Drive technology overview
Page 8
... serial communication interface that supports one -third the capacity of the routing tables supported in each direction. SATA 1.5 Gb/s with HP ProLiant G6 servers in a SAS fabric, although the practical limit is targeted to be built into the mother board or provided as entry level ...is only achieved using new SAS-2 compliant disk drives. Drive throughputs, the maximum rates at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00301688/c00301688.pdf Interconnect bandwidths and drive throughput Both SATA and SAS channel bandwidths are fairly straightforward. The 6 Gb/s SAS...
... serial communication interface that supports one -third the capacity of the routing tables supported in each direction. SATA 1.5 Gb/s with HP ProLiant G6 servers in a SAS fabric, although the practical limit is targeted to be built into the mother board or provided as entry level ...is only achieved using new SAS-2 compliant disk drives. Drive throughputs, the maximum rates at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00301688/c00301688.pdf Interconnect bandwidths and drive throughput Both SATA and SAS channel bandwidths are fairly straightforward. The 6 Gb/s SAS...