Error Prevention Guide
Page 7
...surface of tape cartridge label placement. it cannot fall off or get lodged inside the tape drive. • Consider keeping certain spare parts available onsite. A visual check can prevent many problems. • Be sure that adequate space exists around them . When problems...Processor Power Modules (PPMs), and perhaps even complete I/O, media, processor, and memory modules, if the server is modular. • Restock spare parts as magnetized screwdrivers and telephones with the resolution notebook. This could help in troubleshooting networking problems. • If you have a tape ...
...surface of tape cartridge label placement. it cannot fall off or get lodged inside the tape drive. • Consider keeping certain spare parts available onsite. A visual check can prevent many problems. • Be sure that adequate space exists around them . When problems...Processor Power Modules (PPMs), and perhaps even complete I/O, media, processor, and memory modules, if the server is modular. • Restock spare parts as magnetized screwdrivers and telephones with the resolution notebook. This could help in troubleshooting networking problems. • If you have a tape ...
Compaq ProLiant CL1850 Software User Guide
Page 43
... that is a group member. Table 3-5 Physical Drive States Drive State Icon State Good Reconstructing Spare Failed Description Physical drive is being written to this physical drive. Icons representing the Shared Storage RAID...part of the disks in Table 3-5. Physical drive is not available but is available for use in Table 3-6. Available Physical drive is installed. Reconstruction data is operating normally as shown in a logical drive or as a spare. The physical drive states and corresponding icons are arranged just below the physical drives. 3-12 Compaq ProLiant CL1850...
... that is a group member. Table 3-5 Physical Drive States Drive State Icon State Good Reconstructing Spare Failed Description Physical drive is being written to this physical drive. Icons representing the Shared Storage RAID...part of the disks in Table 3-5. Physical drive is not available but is available for use in Table 3-6. Available Physical drive is installed. Reconstruction data is operating normally as shown in a logical drive or as a spare. The physical drive states and corresponding icons are arranged just below the physical drives. 3-12 Compaq ProLiant CL1850...
Compaq ProLiant CL1850 Software User Guide
Page 57
...Compaq ProLiant CL1850 Software User Guide Setting a Physical Drive as a Spare NOTE: Spare drives serve as spares to a nonfailed state, from the main screen because the failed icon will appear. How a Spare Works s If a physical drive fails in a RAID 1, RAID 0+1, RAID 4, or RAID 5 logical drive, the spare ...physical drive fail, the logical drive will protect the integrity of . s Once the controller writes data to a spare, the spare becomes part of the spare changes to a spare, the status of the same device group in the Available state. 2. In the main window, click the physical...
...Compaq ProLiant CL1850 Software User Guide Setting a Physical Drive as a Spare NOTE: Spare drives serve as spares to a nonfailed state, from the main screen because the failed icon will appear. How a Spare Works s If a physical drive fails in a RAID 1, RAID 0+1, RAID 4, or RAID 5 logical drive, the spare ...physical drive fail, the logical drive will protect the integrity of . s Once the controller writes data to a spare, the spare becomes part of the spare changes to a spare, the status of the same device group in the Available state. 2. In the main window, click the physical...