HP USB Floppy Drive Key Installation Instructions
Page 1
... the drive key The device switch on the drive key determines how the device is subject to a USB port on the server. To connect the drive key, insert the key into the port. © Copyright 2007 Hewlett-Packard Development Company, L.P. ...both USB drive key and USB floppy drive functionality. HP USB Floppy Drive Key Installation Instructions Overview The USB Floppy Drive Key provides HP ProLiant server users with HP ProLiant servers running Microsoft® Windows® Server™ 2000, Microsoft® Windows Server™ 2003, and Linux distributions, including RedHat ...
... the drive key The device switch on the drive key determines how the device is subject to a USB port on the server. To connect the drive key, insert the key into the port. © Copyright 2007 Hewlett-Packard Development Company, L.P. ...both USB drive key and USB floppy drive functionality. HP USB Floppy Drive Key Installation Instructions Overview The USB Floppy Drive Key provides HP ProLiant server users with HP ProLiant servers running Microsoft® Windows® Server™ 2000, Microsoft® Windows Server™ 2003, and Linux distributions, including RedHat ...
ProLiant Essentials Foundation Pack Installation Guide
Page 1
... all system health and configuration information and simplifies access to the Foundation Pack The ProLiant Essentials Foundation Pack contains the SmartStart and Management CDs - This pack supports HP ProLiant ML and DL 300, 500, and 700 servers, HP ProLiant server blades, and the HP BladeSystem c-Class. • SmartStart - Seventeenth edition (September 2008) Part number 392580-408 Welcome to...
... all system health and configuration information and simplifies access to the Foundation Pack The ProLiant Essentials Foundation Pack contains the SmartStart and Management CDs - This pack supports HP ProLiant ML and DL 300, 500, and 700 servers, HP ProLiant server blades, and the HP BladeSystem c-Class. • SmartStart - Seventeenth edition (September 2008) Part number 392580-408 Welcome to...
HP BladeSystem Management Pack version 1.0 for Microsoft System Center Essentials Troubleshooting Assistant
Page 6
...-operation or if you are refreshing the environment, then from the System Center Essentials operator console. The HP BladeSystem Management Pack for System Center Essentials 2007 kits require prior installation and configuration of the HP ProLiant Server Management Pack for System Center Essentials 2007 kits from the system, then remove the kits using the...
...-operation or if you are refreshing the environment, then from the System Center Essentials operator console. The HP BladeSystem Management Pack for System Center Essentials 2007 kits require prior installation and configuration of the HP ProLiant Server Management Pack for System Center Essentials 2007 kits from the system, then remove the kits using the...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 9
... steps of firmware are installed on systems running Microsoft® System Center Operations Manager 2007. • The HP ProLiant Server Management Pack 1.0 for System Center Essentials 2007 (x64) File name Description HPBladeSystemMPforSCE1_0x Used to install HP BladeSystem Enclosure 86.msi management capability where System Center Essentials is operating in the Microsoft® System Center...
... steps of firmware are installed on systems running Microsoft® System Center Operations Manager 2007. • The HP ProLiant Server Management Pack 1.0 for System Center Essentials 2007 (x64) File name Description HPBladeSystemMPforSCE1_0x Used to install HP BladeSystem Enclosure 86.msi management capability where System Center Essentials is operating in the Microsoft® System Center...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 18
... - Serial Number (empty) - Product Name BladeSystem c-Class fan - Server Name N/A HP BladeSystem Device Bay Name Device Bay 2-ProLiant Server - Bay Number 2 - BIOS Server Name BL480c-VS13 - BIOS Asset Tag Xxxxxxx - Enclosure Serial Number USE6321FJC - Fan Speed (% of Present 2 Interconnect Bays - ROM Version I14 05/17/2006 - Server Name N/A HP BladeSystem Fan Name Fan-Bay1 - Number of max...
... - Serial Number (empty) - Product Name BladeSystem c-Class fan - Server Name N/A HP BladeSystem Device Bay Name Device Bay 2-ProLiant Server - Bay Number 2 - BIOS Server Name BL480c-VS13 - BIOS Asset Tag Xxxxxxx - Enclosure Serial Number USE6321FJC - Fan Speed (% of Present 2 Interconnect Bays - ROM Version I14 05/17/2006 - Server Name N/A HP BladeSystem Fan Name Fan-Bay1 - Number of max...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 20
... view displays the state view of folders and windows for viewing information stored in the HP Servers/Active Alerts view. • HP BladeSystem Enclosures/Device Bay State-This view displays all generated by HP ProLiant Server Management Pack for System Center Essentials 2007: • HP BladeSystem Enclosures-This is the root folder that present information about each...
... view displays the state view of folders and windows for viewing information stored in the HP Servers/Active Alerts view. • HP BladeSystem Enclosures/Device Bay State-This view displays all generated by HP ProLiant Server Management Pack for System Center Essentials 2007: • HP BladeSystem Enclosures-This is the root folder that present information about each...
Booting HP ProLiant servers from a storage area network
Page 1
Booting HP ProLiant servers from a storage area network HOWTO, 2nd edition Abstract...2 Required hardware ...2 Supported firmware versions ...2 Supported Fibre Channel switches ...2 Setting up LUN on HP StorageWorks arrays and zoning on Fibre Channel switches 3 Deploying the OS by CD overview ...3 Deploying the OS by Rapid Deployment Pack overview 4 Before you start...4 Instructions ...4 Scripted installs...6 Image deployment ...6 For more information...7 Call to action ...7
Booting HP ProLiant servers from a storage area network HOWTO, 2nd edition Abstract...2 Required hardware ...2 Supported firmware versions ...2 Supported Fibre Channel switches ...2 Setting up LUN on HP StorageWorks arrays and zoning on Fibre Channel switches 3 Deploying the OS by CD overview ...3 Deploying the OS by Rapid Deployment Pack overview 4 Before you start...4 Instructions ...4 Scripted installs...6 Image deployment ...6 For more information...7 Call to action ...7
Booting HP ProLiant servers from a storage area network
Page 2
...from SAN, points customers to vital information, and contains procedures for optimal system performance and system stability. Now, certain HP ProLiant server, StorageWorks Fibre Channel host bus adapter (HBA), and RAID array combinations support external OS booting. Booting from SAN. ...can choose to verify that your hardware configuration supports booting from internal SCSI and IDE storage devices. Abstract Traditionally, HP ProLiant servers boot operating systems (OSs) from SAN and that you have the required firmware installed. Supported firmware versions Outdated firmware...
...from SAN, points customers to vital information, and contains procedures for optimal system performance and system stability. Now, certain HP ProLiant server, StorageWorks Fibre Channel host bus adapter (HBA), and RAID array combinations support external OS booting. Booting from SAN. ...can choose to verify that your hardware configuration supports booting from internal SCSI and IDE storage devices. Abstract Traditionally, HP ProLiant servers boot operating systems (OSs) from SAN and that you have the required firmware installed. Supported firmware versions Outdated firmware...
Booting HP ProLiant servers from a storage area network
Page 4
... use Windows Edition 3.00 (or greater) to determine which ProLiant servers and OSs are using Windows Edition 1.00, you must upgrade to the three support manuals listed in the "Setting up LUN on HP StorageWorks arrays and zoning on Fibre Channel switches" section for important...the following steps to execute the Read ProLiant ML/DL/BL QLogic HBA Configuration [server specific] job from the Server Deployment Toolbox\1 - Provision the SAN storage for boot from an HP StorageWorks Storage Area Network (SAN). If you start Consult the HP ProLiant Essentials Rapid Deployment Pack - Refer to ...
... use Windows Edition 3.00 (or greater) to determine which ProLiant servers and OSs are using Windows Edition 1.00, you must upgrade to the three support manuals listed in the "Setting up LUN on HP StorageWorks arrays and zoning on Fibre Channel switches" section for important...the following steps to execute the Read ProLiant ML/DL/BL QLogic HBA Configuration [server specific] job from the Server Deployment Toolbox\1 - Provision the SAN storage for boot from an HP StorageWorks Storage Area Network (SAN). If you start Consult the HP ProLiant Essentials Rapid Deployment Pack - Refer to ...
Booting HP ProLiant servers from a storage area network
Page 7
.... TC070303HT, 3/2007 The only warranties for Optimal Performance and Functionality of HP ProLiant Servers http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00403562/c00403562.pdf http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00264524/c00264524.pdf Call to action Send... for technical or editorial errors or omissions contained herein. HP shall not be construed as constituting an additional warranty. Source Hyperlink HP StorageWorks SAN Design Reference Guide Regular Firmware Updates Essential for HP products and services are set forth in the express warranty...
.... TC070303HT, 3/2007 The only warranties for Optimal Performance and Functionality of HP ProLiant Servers http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00403562/c00403562.pdf http://h20000.www2.hp.com/bc/docs/support/SupportM anual/c00264524/c00264524.pdf Call to action Send... for technical or editorial errors or omissions contained herein. HP shall not be construed as constituting an additional warranty. Source Hyperlink HP StorageWorks SAN Design Reference Guide Regular Firmware Updates Essential for HP products and services are set forth in the express warranty...
Citrix XenDesktop architecture and implementation on ProLiant servers
Page 1
Citrix XenDesktop Architecture and Implementation on ProLiant Servers integration note Abstract...2 What is Citrix XenDesktop?...2 Virtual Desktops ...2 Why use the HP integrated XenServer 4 HP ProLiant Virtual Console ...4 Faster provisioning ...6 Versions of XenDesktop available from HP 6 The HP XenDesktop solution ...8 Hardware requirements for XenDesktop 2.1 8 Setup and deployment ...8 HP thin clients...10 Why use HP thin clients?...11 Why not reutilize existing devices 11 For more information...13 Call to action ...13
Citrix XenDesktop Architecture and Implementation on ProLiant Servers integration note Abstract...2 What is Citrix XenDesktop?...2 Virtual Desktops ...2 Why use the HP integrated XenServer 4 HP ProLiant Virtual Console ...4 Faster provisioning ...6 Versions of XenDesktop available from HP 6 The HP XenDesktop solution ...8 Hardware requirements for XenDesktop 2.1 8 Setup and deployment ...8 HP thin clients...10 Why use HP thin clients?...11 Why not reutilize existing devices 11 For more information...13 Call to action ...13
Citrix XenDesktop architecture and implementation on ProLiant servers
Page 2
... to describe Citrix XenDesktop technology, architecture, and implementation on ProLiant servers. HP provides an integrated version of virtual machines between servers. On the server side, XenServer provides server virtualization, enabling one hardware device to host multiple server operating systems (such as Windows XP or Vista) to provide better server utilization and data center consolidation. When a user logs out...
... to describe Citrix XenDesktop technology, architecture, and implementation on ProLiant servers. HP provides an integrated version of virtual machines between servers. On the server side, XenServer provides server virtualization, enabling one hardware device to host multiple server operating systems (such as Windows XP or Vista) to provide better server utilization and data center consolidation. When a user logs out...
Citrix XenDesktop architecture and implementation on ProLiant servers
Page 5
...and Mouse). ProLiant Virtual Console HP PVC greatly simplifies single-server virtual machine management, either remotely using HP iLO, or using one of HP ProLiant server management. 5 HP has worked closely with the ability to allow management of HP-integrated Citrix XenServer on HP ProLiant hardware. The HP PVC management...other in the management of virtual machines and a single physical ProLiant server. Using the server's local KVM, HP PVC provides the same graphical interface to manage individual servers, Citrix XenCenter is only available in this manner combines seamless ...
...and Mouse). ProLiant Virtual Console HP PVC greatly simplifies single-server virtual machine management, either remotely using HP iLO, or using one of HP ProLiant server management. 5 HP has worked closely with the ability to allow management of HP-integrated Citrix XenServer on HP ProLiant hardware. The HP PVC management...other in the management of virtual machines and a single physical ProLiant server. Using the server's local KVM, HP PVC provides the same graphical interface to manage individual servers, Citrix XenCenter is only available in this manner combines seamless ...
Citrix XenDesktop architecture and implementation on ProLiant servers
Page 6
...desktop running in HP BladeSystem ProLiant server blades and ProLiant servers": http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01518167/c01518167.pdf. The shared desktop image is available from HP HP offers Citrix XenDesktop in the VDI environment Additional information about the HP ProLiant Virtual Console is ... to deliver a single, standard desktop image on-demand to the pool, XenDesktop manages the number of HP ProLiant servers in three integrated packages on preset rules. Versions of XenDesktop available from the technology brief "Integrated hypervisor virtualization technologies ...
...desktop running in HP BladeSystem ProLiant server blades and ProLiant servers": http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01518167/c01518167.pdf. The shared desktop image is available from HP HP offers Citrix XenDesktop in the VDI environment Additional information about the HP ProLiant Virtual Console is ... to deliver a single, standard desktop image on-demand to the pool, XenDesktop manages the number of HP ProLiant servers in three integrated packages on preset rules. Versions of XenDesktop available from the technology brief "Integrated hypervisor virtualization technologies ...
Citrix XenDesktop architecture and implementation on ProLiant servers
Page 7
... XenServer, which occupies an adjacent slot in -one solution with computing availability. Table 1. Citrix XenServer HP Standard Edition leverages an HP ProLiant server's direct-attached storage (DAS). The Standard Edition includes the HP Select version of virtual machines per server, with up to 32 GB memory per virtual machine. the Advanced and Enterprise Editions include the...
... XenServer, which occupies an adjacent slot in -one solution with computing availability. Table 1. Citrix XenServer HP Standard Edition leverages an HP ProLiant server's direct-attached storage (DAS). The Standard Edition includes the HP Select version of virtual machines per server, with up to 32 GB memory per virtual machine. the Advanced and Enterprise Editions include the...
Citrix XenDesktop architecture and implementation on ProLiant servers
Page 8
... support the XenDesktop solution. Memory - A device running Windows XP with Service Pack 2 or Windows Vista with HP System Insight Manager (HP SIM) agents and ProLiant Essentials Virtual Machine Management (VMM) for HP ProLiant servers and storage. XenCenter can perform all components function properly, and the proper configuration and optimizations have been made. 8 Hardware requirements for VMware...
... support the XenDesktop solution. Memory - A device running Windows XP with Service Pack 2 or Windows Vista with HP System Insight Manager (HP SIM) agents and ProLiant Essentials Virtual Machine Management (VMM) for HP ProLiant servers and storage. XenCenter can perform all components function properly, and the proper configuration and optimizations have been made. 8 Hardware requirements for VMware...
Citrix XenDesktop architecture and implementation on ProLiant servers
Page 13
... warranty statements accompanying such products and services. Citrix Solutions HP Virtual Desktop Infrastructure HP Integrated Citrix XenServer HP ActiveAnswers paper "Virtualization with Citrix XenServer Enterprise Edition v4 on HP ProLiant servers" HP ActiveAnswers for Citrix HP BladeSystem platforms HP ProLiant servers HP integrated Citrix XenServer for HP ProLiant servers white paper Getting Started with Citrix XenDesktop HP Virtual Desktop Infrastructure with Citrix XenDesktop Getting Started Guide...
... warranty statements accompanying such products and services. Citrix Solutions HP Virtual Desktop Infrastructure HP Integrated Citrix XenServer HP ActiveAnswers paper "Virtualization with Citrix XenServer Enterprise Edition v4 on HP ProLiant servers" HP ActiveAnswers for Citrix HP BladeSystem platforms HP ProLiant servers HP integrated Citrix XenServer for HP ProLiant servers white paper Getting Started with Citrix XenDesktop HP Virtual Desktop Infrastructure with Citrix XenDesktop Getting Started Guide...
Drive technology overview
Page 3
... continue to fit mechanically and electrically with HP ProLiant servers or storage products. HP Enterprise drives provide maximum reliability, highest performance, scalability, and error management under the most SAS-based StorageWorks and HP Integrity server products as half the power and generate ... basic characteristics of the art design - Mission critical - High I /O workloads and are intended for servers are the only class of HP server disk drives General description Use environments Entry drives (ETY) Performance and reliability intended for implementations that affect ...
... continue to fit mechanically and electrically with HP ProLiant servers or storage products. HP Enterprise drives provide maximum reliability, highest performance, scalability, and error management under the most SAS-based StorageWorks and HP Integrity server products as half the power and generate ... basic characteristics of the art design - Mission critical - High I /O workloads and are intended for servers are the only class of HP server disk drives General description Use environments Entry drives (ETY) Performance and reliability intended for implementations that affect ...
Drive technology overview
Page 13
....pdf Technology brief Solid state drive technology for ProLiant servers http://h20000.www2.hp.com/bc/docs/support/SupportManu al/c01580706/c01580706.pdf HP Serial ATA Drives overview http://h18004.www1.hp.com/products/servers/proliants torage/serial/sata/index.html HP Disk Drives for ProLiant Servers http://h18004.www1.hp.com/products/servers/proliants torage/drives-enclosures/index.html Call to action...
....pdf Technology brief Solid state drive technology for ProLiant servers http://h20000.www2.hp.com/bc/docs/support/SupportManu al/c01580706/c01580706.pdf HP Serial ATA Drives overview http://h18004.www1.hp.com/products/servers/proliants torage/serial/sata/index.html HP Disk Drives for ProLiant Servers http://h18004.www1.hp.com/products/servers/proliants torage/drives-enclosures/index.html Call to action...
Fully-Buffered DIMM technology in HP ProLiant servers
Page 1
Fully-Buffered DIMM technology in HP ProLiant servers technology brief Abstract...2 Introduction...2 Performance barriers for traditional DIMM 2 Fully-Buffered DIMM architecture ...4 Benefits...6 Simplified board design ...6 Higher memory capacity ...6 Higher performance...7 Improved reliability...7 Challenges ...8 Latency ...8 Power and thermal loads...8 Performance tuning, achieving maximum performance 9 Conclusion...9 For more information...10 Call to action ...10
Fully-Buffered DIMM technology in HP ProLiant servers technology brief Abstract...2 Introduction...2 Performance barriers for traditional DIMM 2 Fully-Buffered DIMM architecture ...4 Benefits...6 Simplified board design ...6 Higher memory capacity ...6 Higher performance...7 Improved reliability...7 Challenges ...8 Latency ...8 Power and thermal loads...8 Performance tuning, achieving maximum performance 9 Conclusion...9 For more information...10 Call to action ...10