HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 7
... c-Class Enclosures represented in the Diagram View • Console Tasks to launch HP Onboard Administrator, HP Enclosure Monitor Manager, and HP Integrated Lights-Out Management Processors from the System Center Essentials Console • Access to HP BladeSystem c-Class Enclosure and other HP ProLiant Essentials value-added software for hardware performance management, vulnerability assessment, and advanced lifecycle administration...
... c-Class Enclosures represented in the Diagram View • Console Tasks to launch HP Onboard Administrator, HP Enclosure Monitor Manager, and HP Integrated Lights-Out Management Processors from the System Center Essentials Console • Access to HP BladeSystem c-Class Enclosure and other HP ProLiant Essentials value-added software for hardware performance management, vulnerability assessment, and advanced lifecycle administration...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 18
... Number 404704-B21 - BIOS Server Name BL480c-VS13 - Integrated Lights-Out Name ILOUSM62500TE - Spare Part Number 413996-001 - Product Name ProLiant BL685c G1 - ROM Version I14 05/17/2006 - Integrated Lights-Out Model iLO2 - Redundancy Redundant - Server Name N/A HP BladeSystem Device Bay Name Device Bay 2-ProLiant Server - Enclosure Serial Number USE6321FJC - Class Property name Sample...
... Number 404704-B21 - BIOS Server Name BL480c-VS13 - Integrated Lights-Out Name ILOUSM62500TE - Spare Part Number 413996-001 - Product Name ProLiant BL685c G1 - ROM Version I14 05/17/2006 - Integrated Lights-Out Model iLO2 - Redundancy Redundant - Server Name N/A HP BladeSystem Device Bay Name Device Bay 2-ProLiant Server - Enclosure Serial Number USE6321FJC - Class Property name Sample...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 35
To launch the HP Integrated Lights-Out task to HP Onboard Administrator. Click HP Onboard Administrator. 3. Log in HP BladeSystem Enclosures include an Integrated Lights-Out management processor, which enables you to remotely access the selected HP ProLiant Blade server. Click HP Integrated Lights-Out. HP Integrated Lights-Out task Blade Servers in to display information: 1. The HP BladeSystem Management Pack 1.0 for System Center...
To launch the HP Integrated Lights-Out task to HP Onboard Administrator. Click HP Onboard Administrator. 3. Log in HP BladeSystem Enclosures include an Integrated Lights-Out management processor, which enables you to remotely access the selected HP ProLiant Blade server. Click HP Integrated Lights-Out. HP Integrated Lights-Out task Blade Servers in to display information: 1. The HP BladeSystem Management Pack 1.0 for System Center...
Citrix XenDesktop architecture and implementation on ProLiant servers
Page 7
...to view multiple servers and their storage capacity by using HP PVC and either a directly connected keyboard, mouse and monitor, or use HP Integrated Lights-out 2 (iLO2). Citrix XenDesktop HP Advanced Edition The Advanced Edition includes all the capabilities of...editions of XenServer; Virtual Desktop Provisioning - The Standard Edition includes the HP Select version of XenDesktop. HP suggests that runs on almost any device. Citrix XenServer HP Standard Edition leverages an HP ProLiant server's direct-attached storage (DAS). Application delivery provides applications and ...
...to view multiple servers and their storage capacity by using HP PVC and either a directly connected keyboard, mouse and monitor, or use HP Integrated Lights-out 2 (iLO2). Citrix XenDesktop HP Advanced Edition The Advanced Edition includes all the capabilities of...editions of XenServer; Virtual Desktop Provisioning - The Standard Edition includes the HP Select version of XenDesktop. HP suggests that runs on almost any device. Citrix XenServer HP Standard Edition leverages an HP ProLiant server's direct-attached storage (DAS). Application delivery provides applications and ...
HP Insight Management Agents architecture for Windows servers
Page 18
...distributed computing environments. HP Systems Insight Manager 5.3 provides full integration with ProLiant 100-series G6 servers, including discovery and association with G6 servers and HP SIM 5.3, HP ProLiant 100 - HP Insight Management WBEM Providers The HP Insight Management Web-...HP SIM. Conclusion The HP Insight Management Agents for Windows servers continue to the WMI service, part of the WBEM standard. The WBEM Providers client-side architecture also incorporates the System Management Homepage framework. Support for ProLiant 100-series servers Beginning with the Lights...
...distributed computing environments. HP Systems Insight Manager 5.3 provides full integration with ProLiant 100-series G6 servers, including discovery and association with G6 servers and HP SIM 5.3, HP ProLiant 100 - HP Insight Management WBEM Providers The HP Insight Management Web-...HP SIM. Conclusion The HP Insight Management Agents for Windows servers continue to the WMI service, part of the WBEM standard. The WBEM Providers client-side architecture also incorporates the System Management Homepage framework. Support for ProLiant 100-series servers Beginning with the Lights...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 3
... relationship between power capping and other server components. These increases, combined with ProLiant servers, the Integrated Lights Out (iLO 2) management processor, and the Insight Power Manager (IPM) plug-in for HP Systems Insight Manager (SIM). This provides increased flexibility in both the memory... a task, then the execution of that power capping does not reduce the total energy consumption required for one of HP ProLiant servers that are therefore not dependent on the operating system or applications. The power management system accomplishes this processor-driven ...
... relationship between power capping and other server components. These increases, combined with ProLiant servers, the Integrated Lights Out (iLO 2) management processor, and the Insight Power Manager (IPM) plug-in for HP Systems Insight Manager (SIM). This provides increased flexibility in both the memory... a task, then the execution of that power capping does not reduce the total energy consumption required for one of HP ProLiant servers that are therefore not dependent on the operating system or applications. The power management system accomplishes this processor-driven ...
HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 26
... or editorial errors or omissions contained herein. Nothing herein should be liable for a single server or groups of HP ProLiant servers. Intel is used under license. Source HP Power Management HP Insight Power Manager HP Integrated Lights-Out HP SIM page on their workload requirements. Enclosure Dynamic Power Capping represents the newest and most sophisticated implementation of...
... or editorial errors or omissions contained herein. Nothing herein should be liable for a single server or groups of HP ProLiant servers. Intel is used under license. Source HP Power Management HP Insight Power Manager HP Integrated Lights-Out HP SIM page on their workload requirements. Enclosure Dynamic Power Capping represents the newest and most sophisticated implementation of...
HP ProLiant G6 Technology Overview
Page 2
...power supplies. It is now available in the same way. 2 Introducing the HP ProLiant G6 servers The sixth-generation (G6) of HP ProLiant DL, ML, and BL servers is now implemented across the ProLiant G6 server portfolio and includes Dynamic Power Capping, a 'Sea of Sensors', and ..., embedded server health monitoring, and lights-out remote administration for ProLiant automates the migration process by overly conservative power allocation based on the Intel® Xeon® processor 5500 series. Decrease virtualization complexity • HP Insight Server Migration software for individual...
...power supplies. It is now available in the same way. 2 Introducing the HP ProLiant G6 servers The sixth-generation (G6) of HP ProLiant DL, ML, and BL servers is now implemented across the ProLiant G6 server portfolio and includes Dynamic Power Capping, a 'Sea of Sensors', and ..., embedded server health monitoring, and lights-out remote administration for ProLiant automates the migration process by overly conservative power allocation based on the Intel® Xeon® processor 5500 series. Decrease virtualization complexity • HP Insight Server Migration software for individual...
HP ProLiant G6 Technology Overview
Page 8
...control of remote servers. The Insight Orchestration option for the logical server management and other capabilities delivered with HP Insight Control suite to a single physical ProLiant server blade, Flex-10 allows you analyze and optimize physical and virtual resources in the same way. ... Dynamics-VSE HP ID-VSE is a hardware-based solution that lets you to partition each 10GbE network connection and regulate the speed of each partition based on face plate ratings. • Lights-Out remote administration -Use Integrated Remote Console to manage: • Continuously consolidating...
...control of remote servers. The Insight Orchestration option for the logical server management and other capabilities delivered with HP Insight Control suite to a single physical ProLiant server blade, Flex-10 allows you analyze and optimize physical and virtual resources in the same way. ... Dynamics-VSE HP ID-VSE is a hardware-based solution that lets you to partition each 10GbE network connection and regulate the speed of each partition based on face plate ratings. • Lights-Out remote administration -Use Integrated Remote Console to manage: • Continuously consolidating...
ISS Technology Update Index
Page 2
...1 management for ProLiant and ProLiant server blades HP Solid State Drive technology 1 Volume 7, Number 9 October 2008 Volume 7, Number 6 June 2008 Volume 7, Number 10 December 2008 I | K | L | M | N | O | P | Q | R | S | T | U | V | W | Z Article title Page Newsletter issue number Publication date H How many bytes are in industry 4 standards for HP 6 c-Class ...Volume 7, Number 5 May 2008 1 Volume 7, Number 7 August 2008 K Kerberos technology with HP Integrated Lights-Out 3 4 Volume 9, Number 2 February 2010 L Licensing ports on the Brocade 4/12 SAN Switch for storage...
...1 management for ProLiant and ProLiant server blades HP Solid State Drive technology 1 Volume 7, Number 9 October 2008 Volume 7, Number 6 June 2008 Volume 7, Number 10 December 2008 I | K | L | M | N | O | P | Q | R | S | T | U | V | W | Z Article title Page Newsletter issue number Publication date H How many bytes are in industry 4 standards for HP 6 c-Class ...Volume 7, Number 5 May 2008 1 Volume 7, Number 7 August 2008 K Kerberos technology with HP Integrated Lights-Out 3 4 Volume 9, Number 2 February 2010 L Licensing ports on the Brocade 4/12 SAN Switch for storage...
ISS Technology Update Volume 7, Number 10
Page 6
... following websites for additional information on the topics discussed in this article: Resource HP Integrated Lights-Out DMTF SMASH information Common SM CLP scripting commands for ProLiant server management, Part 1 Common SM CLP scripting commands for ProLiant server management, Part 2 URL www.hp.com/go/ilo www.dmtf.org/standards/mgmt/smash/ http://h20000.www2...
... following websites for additional information on the topics discussed in this article: Resource HP Integrated Lights-Out DMTF SMASH information Common SM CLP scripting commands for ProLiant server management, Part 1 Common SM CLP scripting commands for ProLiant server management, Part 2 URL www.hp.com/go/ilo www.dmtf.org/standards/mgmt/smash/ http://h20000.www2...
ISS Technology Update Volume 8, Number 1
Page 3
The technology brief titled "Integrating HP ProLiant Lights-Out processors with Integrated Lights-Out devices to maintain iLO user accounts. The document includes a statement about iLO being able to use the Lightweight Directory Access Protocol (LDAP) ... iLO or iLO 2 Server administrators using Microsoft Active Directory (AD) can integrate it with Microsoft® Active Directory," available at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00190541/c00190541.pdf, describes the integration steps. Administrators should configure iLO to reference the DNS name of the domain, not...
The technology brief titled "Integrating HP ProLiant Lights-Out processors with Integrated Lights-Out devices to maintain iLO user accounts. The document includes a statement about iLO being able to use the Lightweight Directory Access Protocol (LDAP) ... iLO or iLO 2 Server administrators using Microsoft Active Directory (AD) can integrate it with Microsoft® Active Directory," available at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00190541/c00190541.pdf, describes the integration steps. Administrators should configure iLO to reference the DNS name of the domain, not...
ISS Technology Update Volume 8, Number 1
Page 4
... Mechanics, 1984 University of Houston, Houston, TX: Masters of becoming an astronaut (50,000 applicants to go /ilo "Integrating HP ProLiant Lights-Out processors with Microsoft® Active Directory" Integration Note http://h20000.www2.hp.com/bc/docs/support/Support Manual/c00190541/c00190541.pdf Microsoft TechNet online publication, "Understanding Domains and Forests", from an...
... Mechanics, 1984 University of Houston, Houston, TX: Masters of becoming an astronaut (50,000 applicants to go /ilo "Integrating HP ProLiant Lights-Out processors with Microsoft® Active Directory" Integration Note http://h20000.www2.hp.com/bc/docs/support/Support Manual/c00190541/c00190541.pdf Microsoft TechNet online publication, "Understanding Domains and Forests", from an...
ISS Technology Update Volume 8, Number 6
Page 1
... Integrated Lights-Out technology: Enhancing the manageability of ProLiant Servers, 7th edition http://h20000.www2.hp.com/bc/docs/support/SupportManual/c002573 45/c00257345.pdf Selecting power cords and jumper cables for use with HP http://h20000.www2.hp.com/bc/docs/support/SupportManual/c001307 ProLiant and BladeSystem servers, 3rd edition 29/c00130729.pdf Technologies in HP ProLiant G6...
... Integrated Lights-Out technology: Enhancing the manageability of ProLiant Servers, 7th edition http://h20000.www2.hp.com/bc/docs/support/SupportManual/c002573 45/c00257345.pdf Selecting power cords and jumper cables for use with HP http://h20000.www2.hp.com/bc/docs/support/SupportManual/c001307 ProLiant and BladeSystem servers, 3rd edition 29/c00130729.pdf Technologies in HP ProLiant G6...
ISS Technology Update Volume 8, Number 7
Page 5
... for light duty applications such as photo storage and occasional file transfer. The flash memory in HP server SSDs uses single-level cell technology, which has a much higher reliability than HP enterprise SAS...HP ProLiant BL495c server blades are several alternatives for deploying virtualized infrastructures. Despite elaborate wear-level techniques, these systems. Thus, a single SSD is comparable to ensure continued operation. Configuration alternatives There are ideal systems for configuring an ESXi installation on the BL490c G6 server, including installing the image on HP...
... for light duty applications such as photo storage and occasional file transfer. The flash memory in HP server SSDs uses single-level cell technology, which has a much higher reliability than HP enterprise SAS...HP ProLiant BL495c server blades are several alternatives for deploying virtualized infrastructures. Despite elaborate wear-level techniques, these systems. Thus, a single SSD is comparable to ensure continued operation. Configuration alternatives There are ideal systems for configuring an ESXi installation on the BL490c G6 server, including installing the image on HP...
ISS Technology Update, Volume 7 Number 1 - Newsletter
Page 10
... and ML servers HP ProLiant DL and ML servers implement several technologies for example, HP Systems Insight Manager and Insight Agents) and to as possible without risking data corruption. The iLO controller resides on their redundancy. Alternatively, the ProLiant 100 series ML and DL servers use the Integrated Lights-Out (iLO) management controller. In this...
... and ML servers HP ProLiant DL and ML servers implement several technologies for example, HP Systems Insight Manager and Insight Agents) and to as possible without risking data corruption. The iLO controller resides on their redundancy. Alternatively, the ProLiant 100 series ML and DL servers use the Integrated Lights-Out (iLO) management controller. In this...
ISS Technology Update, Volume 7 Number 1 - Newsletter
Page 11
...Log (IML) is determined that support redundant fans ProLiant DL servers ProLiant ML servers DL360 DL365 ML350 DL380 DL385 ML370 DL580 DL585 ML570 NOTE: The ML350 G1 through the Integrated Lights-Out user interface. 11 Failure behavior of ProLiant DL and ML servers with redundant fans Scenario ...AMD processor-based systems, graceful shutdowns can be maintained. ISS Technology Update Volume 7, Number 1 Models with redundant fans Several ProLiant DL and ML server models support fan sets that support redundant fans are listed in Table 5-1. The health LED turns to...
...Log (IML) is determined that support redundant fans ProLiant DL servers ProLiant ML servers DL360 DL365 ML350 DL380 DL385 ML370 DL580 DL585 ML570 NOTE: The ML350 G1 through the Integrated Lights-Out user interface. 11 Failure behavior of ProLiant DL and ML servers with redundant fans Scenario ...AMD processor-based systems, graceful shutdowns can be maintained. ISS Technology Update Volume 7, Number 1 Models with redundant fans Several ProLiant DL and ML server models support fan sets that support redundant fans are listed in Table 5-1. The health LED turns to...
ISS Technology Update, Volume 7 Number 1 - Newsletter
Page 16
...communications Title AMD Opteron processor scalability and performance in the express warranty statements accompanying such products and services. Technology Brief HP ProLiant DL585 G2 server technology - AMD and AMD Opteron are trademarks of Intel Corporation in the United States and other countries... forth in ProLiant DL585 G2 servers - The only warranties for technical or editorial errors or omissions contained herein. HP shall not be liable for HP products and services are US registered trademarks of Advanced Micro Devices, Inc. Technology Brief HP Integrated Lights-Out security ...
...communications Title AMD Opteron processor scalability and performance in the express warranty statements accompanying such products and services. Technology Brief HP ProLiant DL585 G2 server technology - AMD and AMD Opteron are trademarks of Intel Corporation in the United States and other countries... forth in ProLiant DL585 G2 servers - The only warranties for technical or editorial errors or omissions contained herein. HP shall not be liable for HP products and services are US registered trademarks of Advanced Micro Devices, Inc. Technology Brief HP Integrated Lights-Out security ...
ISS Technology Update, Volume 7, Number 7
Page 11
... Title "Integrating HP ProLiant Lights-Out processors with Microsoft® Active Directory" technology brief "Integrated hypervisor virtualization technologies in HP BladeSystem ProLiant server blades and ProLiant servers" technology brief "Implementing Microsoft Windows Server 2008 Hyper-V on HP ProLiant servers" integration note "Integrating HP Insight Management WBEM Providers with HP System Insight Manager" integration note "Implementing Novell NetWare 6.5 on HP ProLiant servers" integration...
... Title "Integrating HP ProLiant Lights-Out processors with Microsoft® Active Directory" technology brief "Integrated hypervisor virtualization technologies in HP BladeSystem ProLiant server blades and ProLiant servers" technology brief "Implementing Microsoft Windows Server 2008 Hyper-V on HP ProLiant servers" integration note "Integrating HP Insight Management WBEM Providers with HP System Insight Manager" integration note "Implementing Novell NetWare 6.5 on HP ProLiant servers" integration...
ISS Technology Update, Volume 7, Number 8
Page 5
...and license terms are not specified, iLO 2 prompts for account credentials, interrupting the process. The following examples demonstrate SSH command mode using the Integrated Lights-Out 2 (iLO 2) processor. C:\putty>plink -ssh -l admin -pw password ilo2system.corp.net stop system1 stop system1" command issues a virtual ... by processing a single command at a time. ISS Technology Update Volume 7, Number 8 Common SM CLP scripting commands for ProLiant server management This is the first in a similar manner. Some customers want to use SM CLP to perform basic target operations on...
...and license terms are not specified, iLO 2 prompts for account credentials, interrupting the process. The following examples demonstrate SSH command mode using the Integrated Lights-Out 2 (iLO 2) processor. C:\putty>plink -ssh -l admin -pw password ilo2system.corp.net stop system1 stop system1" command issues a virtual ... by processing a single command at a time. ISS Technology Update Volume 7, Number 8 Common SM CLP scripting commands for ProLiant server management This is the first in a similar manner. Some customers want to use SM CLP to perform basic target operations on...