HP Insight Diagnostics Online Edition Featuring Survey Utility and IML Viewer
Page 11
Obtain the latest software availability alerts and upcoming new feature information by SmartStart 6.x and later: ProLiant RBSU-based servers (most G2 models of ProLiant ML/DL 300, 500, 700 and BL servers) For a complete list, view the supported matrices ... 6 NOTE: Navigator requires the JDK 1.1 patch The browser must have the following URL http://www.hp.com/go /support. Specifications HP Insight Diagnostics Online Edition Specifications Supported platforms ProLiant platforms that are supported by subscribing to a device A supported Web browser Accessibility • Windows or...
Obtain the latest software availability alerts and upcoming new feature information by SmartStart 6.x and later: ProLiant RBSU-based servers (most G2 models of ProLiant ML/DL 300, 500, 700 and BL servers) For a complete list, view the supported matrices ... 6 NOTE: Navigator requires the JDK 1.1 patch The browser must have the following URL http://www.hp.com/go /support. Specifications HP Insight Diagnostics Online Edition Specifications Supported platforms ProLiant platforms that are supported by subscribing to a device A supported Web browser Accessibility • Windows or...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 6
ProLiant BL460c - ProLiant DL385 G2 - ProLiant ML350 G5 - ProLiant DL380 G5 - Carefully review this paper, visit the Windows Server 2008 support page: www.microsoft.com/windowsserver2008/default.mspx. 6 ProLiant BL685c • ProLiant DL servers: - In addition to the websites mentioned throughout this document for these servers): • ProLiant BL servers: - ProLiant BL680c G5 - ProLiant DL585 G2 • ProLiant... be encountered. ProLiant DL360 G5 - ProLiant DL580 G5 - Supported configurations Windows Server 2008 should load and run on any HP server listed in...
ProLiant BL460c - ProLiant DL385 G2 - ProLiant ML350 G5 - ProLiant DL380 G5 - Carefully review this paper, visit the Windows Server 2008 support page: www.microsoft.com/windowsserver2008/default.mspx. 6 ProLiant BL685c • ProLiant DL servers: - In addition to the websites mentioned throughout this document for these servers): • ProLiant BL servers: - ProLiant BL680c G5 - ProLiant DL585 G2 • ProLiant... be encountered. ProLiant DL360 G5 - ProLiant DL580 G5 - Supported configurations Windows Server 2008 should load and run on any HP server listed in...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 8
....www1.hp.com/wwsolutions/windows/index.html. Recommended ProLiant server platforms Table 2 lists the ProLiant servers, ROM version, and ROM date that support Windows Server 2008 Server platform ProLiant BL servers: ProLiant BL20p G3 ROM family ROM date (minimum) I08 07/16/07 ProLiant BL20p G4 I13 11/13/07 ProLiant BL25p A02 04/14/05 ProLiant BL25p G2...
....www1.hp.com/wwsolutions/windows/index.html. Recommended ProLiant server platforms Table 2 lists the ProLiant servers, ROM version, and ROM date that support Windows Server 2008 Server platform ProLiant BL servers: ProLiant BL20p G3 ROM family ROM date (minimum) I08 07/16/07 ProLiant BL20p G4 I13 11/13/07 ProLiant BL25p A02 04/14/05 ProLiant BL25p G2...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 9
... G5* P61 12/07/07 ProLiant DL585 A01 03/22/06 ProLiant DL585 G2* A07 11/21/07 ProLiant ML servers: ProLiant ML110 G2 ML110G2 12/08/05 ProLiant ML110 G3 ML110G3 02/13/06 ProLiant ML110 G4 ML110G4 06/05/06 ProLiant ML115 ML115G1 03/10/07 ProLiant ML310 G4 W03 08/21/07 ProLiant ML350 G4 D17 07/16/07...
... G5* P61 12/07/07 ProLiant DL585 A01 03/22/06 ProLiant DL585 G2* A07 11/21/07 ProLiant ML servers: ProLiant ML110 G2 ML110G2 12/08/05 ProLiant ML110 G3 ML110G3 02/13/06 ProLiant ML110 G4 ML110G4 06/05/06 ProLiant ML115 ML115G1 03/10/07 ProLiant ML310 G4 W03 08/21/07 ProLiant ML350 G4 D17 07/16/07...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 10
... 2008. Throughout the summer of Windows Server 2008, the HP Insight Control Management Software portfolio for the HP ProLiant and HP BladeSystem infrastructure deploys, monitors, and manages Windows Server 2008 servers. MSA500 G2 packaged clusters are installed on the Windows Server 2008 operating ...hp.com/go/insightcontrol. 10 ProLiant server platforms that support Windows Server 2008 Server platform ProLiant ML350 G4p ROM family ROM date (minimum) D19 07/16/07 ProLiant ML350 G5* D21 08/21/07 ProLiant ML370 G4 P50 07/19/07 ProLiant ML370 G5* P57 08/21/07 ProLiant...
... 2008. Throughout the summer of Windows Server 2008, the HP Insight Control Management Software portfolio for the HP ProLiant and HP BladeSystem infrastructure deploys, monitors, and manages Windows Server 2008 servers. MSA500 G2 packaged clusters are installed on the Windows Server 2008 operating ...hp.com/go/insightcontrol. 10 ProLiant server platforms that support Windows Server 2008 Server platform ProLiant ML350 G4p ROM family ROM date (minimum) D19 07/16/07 ProLiant ML350 G5* D21 08/21/07 ProLiant ML370 G4 P50 07/19/07 ProLiant ML370 G5* P57 08/21/07 ProLiant...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 16
... platform ProLiant DL140 G2 ProLiant DL140 G3 ProLiant DL145 G2 ProLiant ML110 G3 ProLiant ML110 G4 ROM family DL140G2 DL140G3 DL145G2 ML110G3 ML110G4 Minimum ROM date 03/31/06 06/18/06 03/23/06 02/13/06 06/05/06 HP IPMI Provider for HP BladeSystem servers and ProLiant 300 and 500 Series servers For HP BladeSystem servers and ProLiant 300...
... platform ProLiant DL140 G2 ProLiant DL140 G3 ProLiant DL145 G2 ProLiant ML110 G3 ProLiant ML110 G4 ROM family DL140G2 DL140G3 DL145G2 ML110G3 ML110G4 Minimum ROM date 03/31/06 06/18/06 03/23/06 02/13/06 06/05/06 HP IPMI Provider for HP BladeSystem servers and ProLiant 300 and 500 Series servers For HP BladeSystem servers and ProLiant 300...
ISS Technology Update Volume 8, Number 7
Page 6
...communications HP ProLiant BL490c G6 Server series HP ProLiant BL495c G6 Server series URL http://h18004.www1.hp.com/products/servers/technology /whitepapers/virtualization/index.html http://h10010.www1.hp.com/wwpc/us/en/sm/WF25a/3 709945-3709945-3328410-241641-33284193884113.html http://h10010.www1.hp.com/...pulled from SAN deployments are also possible. For example, a BladeSystem configuration using SAS switch interconnect modules and an HP MSA2000sa G2 SAS shared storage array provides a robust environment that used configuration of ESXi hosts provides greater high availability and fault...
...communications HP ProLiant BL490c G6 Server series HP ProLiant BL495c G6 Server series URL http://h18004.www1.hp.com/products/servers/technology /whitepapers/virtualization/index.html http://h10010.www1.hp.com/wwpc/us/en/sm/WF25a/3 709945-3709945-3328410-241641-33284193884113.html http://h10010.www1.hp.com/...pulled from SAN deployments are also possible. For example, a BladeSystem configuration using SAS switch interconnect modules and an HP MSA2000sa G2 SAS shared storage array provides a robust environment that used configuration of ESXi hosts provides greater high availability and fault...
ISS Technology Update, Volume 7 Number 1 - Newsletter
Page 11
...occur and the other fans will increase in speed to shutdown the system. Failure behavior of ProLiant DL and ML servers with G5 Intel processor-based systems and G2 AMD processor-based systems, graceful shutdowns can be maintained. Graceful shutdowns are installed and configured appropriately...event of events in the IML by iLO. The server models that support redundant fans ProLiant DL servers ProLiant ML servers DL360 DL365 ML350 DL380 DL385 ML370 DL580 DL585 ML570 NOTE: The ML350 G1 through the Integrated Lights-Out user interface. 11 Table 5-2. Single fan fails; The...
...occur and the other fans will increase in speed to shutdown the system. Failure behavior of ProLiant DL and ML servers with G5 Intel processor-based systems and G2 AMD processor-based systems, graceful shutdowns can be maintained. Graceful shutdowns are installed and configured appropriately...event of events in the IML by iLO. The server models that support redundant fans ProLiant DL servers ProLiant ML servers DL360 DL365 ML350 DL380 DL385 ML370 DL580 DL585 ML570 NOTE: The ML350 G1 through the Integrated Lights-Out user interface. 11 Table 5-2. Single fan fails; The...
ISS Technology Update, Volume 7 Number 1 - Newsletter
Page 16
...HP ProLiant DL585 G2 server technology - Nothing herein should be found at www.hp.com/servers/technology. Intel, Intel Xeon, and Intel Itanium are set forth in the United States and other countries. Integration Note Technologies for technical or editorial errors or omissions contained herein. The information contained herein is subject to TechCom@HP.com. HP... shall not be liable for HP ProLiant 100-series servers Technology Brief URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01345 155/c01345155.pdf http://h20000.www2.hp.com/bc/docs/support...
...HP ProLiant DL585 G2 server technology - Nothing herein should be found at www.hp.com/servers/technology. Intel, Intel Xeon, and Intel Itanium are set forth in the United States and other countries. Integration Note Technologies for technical or editorial errors or omissions contained herein. The information contained herein is subject to TechCom@HP.com. HP... shall not be liable for HP ProLiant 100-series servers Technology Brief URL http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01345 155/c01345155.pdf http://h20000.www2.hp.com/bc/docs/support...
ISS Technology Update, Volume 7, Number 7
Page 3
...if a catastrophic event occurred during a ROM upgrade. There was toward engineering. I also wrote the ROM code and worked with all HP Business Units. Volume 7, Number 7 Name: Vincent Nguyen Title: ISS Technologist Years at the time was no one of desired SCSI ...line spare memory DIMM. Below are listed on single- The trend at HP: 20 Education: • University of Houston Bachelor of hotpluggable components in the PC server industry. I designed discrete logic on the ProLiant DL380 G2 server to Gene Freeman, Vincent's manager, many patents. Nguyen, V., ...
...if a catastrophic event occurred during a ROM upgrade. There was toward engineering. I also wrote the ROM code and worked with all HP Business Units. Volume 7, Number 7 Name: Vincent Nguyen Title: ISS Technologist Years at the time was no one of desired SCSI ...line spare memory DIMM. Below are listed on single- The trend at HP: 20 Education: • University of Houston Bachelor of hotpluggable components in the PC server industry. I designed discrete logic on the ProLiant DL380 G2 server to Gene Freeman, Vincent's manager, many patents. Nguyen, V., ...
ISS Technology Update, Volume 8, Number 2
Page 2
...more processors and cores make some difference, any installed memory greater than one . When running workloads. The results for several HP ProLiant servers, illustrates the difference that are then compared against the VMmark reference platform, tile performance scores tend to gravitate around one ...is essentially a processor and core bound benchmark. the aggregate performance scores of all of the tiles are taken as an HP ProLiant DL580 G2, the performance score for each tile that the processor complex is capable of tiles. VMmark workload summary per tile Workload ...
...more processors and cores make some difference, any installed memory greater than one . When running workloads. The results for several HP ProLiant servers, illustrates the difference that are then compared against the VMmark reference platform, tile performance scores tend to gravitate around one ...is essentially a processor and core bound benchmark. the aggregate performance scores of all of the tiles are taken as an HP ProLiant DL580 G2, the performance score for each tile that the processor complex is capable of tiles. VMmark workload summary per tile Workload ...
Memory technology evolution: an overview of system memory technologies, 7th edition
Page 10
... section). These 64 bits constitute an ECC data word. A soft error does not indicate a problem with DRAM density. For example, while the HP ProLiant DL585 G2 of 2007 could support a maximum of 128 GB, some of the latest servers now support up to a memory cell), the same error does not... can only detect errors, while others can cause an application to address more than twice that of the electrical charge. As described earlier, each ProLiant server (see the "Importance of memory. An error in more than one bit of memory errors in the memory option kits for example, by...
... section). These 64 bits constitute an ECC data word. A soft error does not indicate a problem with DRAM density. For example, while the HP ProLiant DL585 G2 of 2007 could support a maximum of 128 GB, some of the latest servers now support up to a memory cell), the same error does not... can only detect errors, while others can cause an application to address more than twice that of the electrical charge. As described earlier, each ProLiant server (see the "Importance of memory. An error in more than one bit of memory errors in the memory option kits for example, by...
Performing an HP ProLiant server NMI crash dump
Page 4
...command to create a core dump. 3. Figure 2. This action presents an ABEND screen. 2. For exact placement, refer to the illustration on a ProLiant DL360 G5 server Figure 3. Note that the core dump file will be as large as the memory installed in the system. 4. Under some ... to initiate a core dump. Figures 2 and 3 are examples of a jumper switch found on a ProLiant DL580 G2 server Under Novell NetWare 6.5 1. Example of jumper pins and switches found on ProLiant servers. Through NMI Crash Dump jumper pins or switch The NMI Crash Dump jumper pins or switch generate ...
...command to create a core dump. 3. Figure 2. This action presents an ABEND screen. 2. For exact placement, refer to the illustration on a ProLiant DL360 G5 server Figure 3. Note that the core dump file will be as large as the memory installed in the system. 4. Under some ... to initiate a core dump. Figures 2 and 3 are examples of a jumper switch found on a ProLiant DL580 G2 server Under Novell NetWare 6.5 1. Example of jumper pins and switches found on ProLiant servers. Through NMI Crash Dump jumper pins or switch The NMI Crash Dump jumper pins or switch generate ...
Power basics for IT professionals
Page 18
... panel determines how power is live and carries power. A single-phase 120V circuit uses a single-pole circuit breaker; For example, a rack full of 21 ProLiant DL380 G2 servers requires 8.6 kVA to balance the electrical load on all three phases of threephase power. Consequently, the load requires at 208 V is the central source...
... panel determines how power is live and carries power. A single-phase 120V circuit uses a single-pole circuit breaker; For example, a rack full of 21 ProLiant DL380 G2 servers requires 8.6 kVA to balance the electrical load on all three phases of threephase power. Consequently, the load requires at 208 V is the central source...
Power basics for IT professionals
Page 31
... standard. In the NEMA nomenclature for plugs and sockets (for 125 V and 30 A. And it is available across the country. Each of HP equipment. It is the HP ProLiant DL580 G2 Server. The C13/C14 connectors are rated for male) 31 One example is called a CS8265c. In the IEC nomenclature for plugs and sockets...
... standard. In the NEMA nomenclature for plugs and sockets (for 125 V and 30 A. And it is available across the country. Each of HP equipment. It is the HP ProLiant DL580 G2 Server. The C13/C14 connectors are rated for male) 31 One example is called a CS8265c. In the IEC nomenclature for plugs and sockets...
System Memory Troubleshooting Best Practices for HP ProLiant Servers
Page 17
... Taking the time to Locate a Specific DIMM on ProLiant Servers when Multiple DIMM Slot Fault LEDs are Illuminated: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c00713352 HP ProLiant DL145 G2 Server Configured with Dual Processors May Not Report Memory ...Installed in DIMM Slots 5 Through 8: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale...
... Taking the time to Locate a Specific DIMM on ProLiant Servers when Multiple DIMM Slot Fault LEDs are Illuminated: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c00713352 HP ProLiant DL145 G2 Server Configured with Dual Processors May Not Report Memory ...Installed in DIMM Slots 5 Through 8: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale...
Implementing Microsoft Windows Server 2008 Service Pack 2 on HP servers
Page 7
... G4p P54 07/16/07 DL360 G5 P58 08/21/07 DL360 G6 P64 03/03/09 DL365 A10 09/20/07 DL365 G5 A10 08/05/08 DL370 G6 P63 03/04/09 DL380 G5 P56 08/21/07 DL380 G6 P62 02/23/09 DL380 G4 Packaged Cluster - MSA1000* P17 07... G4 P59 08/10/07 DL580 G5 P61 12/07/07 DL585 A01 03/22/06 DL585 G2 A07 11/21/07 DL585 G5 A07 08/01/08 DL785 G5 A15 08/01/08 ProLiant ML servers: ML110 G5 015 08/05/08 ML115 G5 018 06/17/08 ML150 G5 017...
... G4p P54 07/16/07 DL360 G5 P58 08/21/07 DL360 G6 P64 03/03/09 DL365 A10 09/20/07 DL365 G5 A10 08/05/08 DL370 G6 P63 03/04/09 DL380 G5 P56 08/21/07 DL380 G6 P62 02/23/09 DL380 G4 Packaged Cluster - MSA1000* P17 07... G4 P59 08/10/07 DL580 G5 P61 12/07/07 DL585 A01 03/22/06 DL585 G2 A07 11/21/07 DL585 G5 A07 08/01/08 DL785 G5 A15 08/01/08 ProLiant ML servers: ML110 G5 015 08/05/08 ML115 G5 018 06/17/08 ML150 G5 017...
Implementing Microsoft Windows Server 2008 Service Pack 2 on HP servers
Page 8
Recommended Integrity server platforms HP Integrity Server BL860c BL870c rx2660 rx3600 rx6600 Rx7620 Rx8620 rx7640 rx8640...ProLiant server platforms that support Windows Server 2008 and Windows Server 2008 Service Pack 2 Server platform ML310 G5 ROM family ROM date (minimum) W05 08/01/08 ML310 G5p W05 08/01/08 ML350 G5 D21 08/21/07 ML350 G6... D22 02/23/09 ML370 G4 P50 07/19/07 ML370 G5 P57 08/21/07 ML370 G6 P63 03/04/09 ML570 G4 P60 08/02/07 *Supported when configured with an MSA1000 only. Table 2. Recommended Integrity server platforms Table 3. MSA500 G2...
Recommended Integrity server platforms HP Integrity Server BL860c BL870c rx2660 rx3600 rx6600 Rx7620 Rx8620 rx7640 rx8640...ProLiant server platforms that support Windows Server 2008 and Windows Server 2008 Service Pack 2 Server platform ML310 G5 ROM family ROM date (minimum) W05 08/01/08 ML310 G5p W05 08/01/08 ML350 G5 D21 08/21/07 ML350 G6... D22 02/23/09 ML370 G4 P50 07/19/07 ML370 G5 P57 08/21/07 ML370 G6 P63 03/04/09 ML570 G4 P60 08/02/07 *Supported when configured with an MSA1000 only. Table 2. Recommended Integrity server platforms Table 3. MSA500 G2...
Implementing Microsoft Windows Server 2008 Service Pack 2 on HP servers
Page 15
... was compatible with server clusters in Windows Server 2003 might not be compatible with BMC Server platform ProLiant DL140 G2 ProLiant DL140 G3 ProLiant DL145 G2 ProLiant ML110 G3 ProLiant ML110 G4 ROM family DL140G2 DL140G3 DL145G2 ML110G3 ML110G4 Minimum ROM date 03/31/06 06/18.../06 03/23/06 02/13/06 06/05/06 HP IPMI Provider for HP BladeSystem servers and ProLiant 300 and 500 Series servers For HP BladeSystem servers and ProLiant...
... was compatible with server clusters in Windows Server 2003 might not be compatible with BMC Server platform ProLiant DL140 G2 ProLiant DL140 G3 ProLiant DL145 G2 ProLiant ML110 G3 ProLiant ML110 G4 ROM family DL140G2 DL140G3 DL145G2 ML110G3 ML110G4 Minimum ROM date 03/31/06 06/18.../06 03/23/06 02/13/06 06/05/06 HP IPMI Provider for HP BladeSystem servers and ProLiant 300 and 500 Series servers For HP BladeSystem servers and ProLiant...