ProLiant Essentials Foundation Pack Installation Guide
Page 1
... hardware, boot the operating system CD to monitor, patch, and control HP ProLiant ML, DL, and BL servers, including systems running Microsoft® Windows®, Linux, HP-UX, and other supported operating systems. • System Management Homepage - ORCA and the Adaptec RAID Configuration Utility are available by assisting hardware configuration and installation of all...
... hardware, boot the operating system CD to monitor, patch, and control HP ProLiant ML, DL, and BL servers, including systems running Microsoft® Windows®, Linux, HP-UX, and other supported operating systems. • System Management Homepage - ORCA and the Adaptec RAID Configuration Utility are available by assisting hardware configuration and installation of all...
HP Insight Server Migration Software for ProLiant User Guide
Page 51
...be migrated. Physical-to the target boot disk. You must be cleared. The wizard verifies if SMP Source Agent is migrated to -ProLiant (P2P) migrations for Windows 51 Volumes marked as active are migrated to a single contiguous partition. If multiple active volumes exist, ensure... that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to partitions on dynamic disks are selected by default. Volumes on basic disks. Select the volumes to be deployed...
...be migrated. Physical-to the target boot disk. You must be cleared. The wizard verifies if SMP Source Agent is migrated to -ProLiant (P2P) migrations for Windows 51 Volumes marked as active are migrated to a single contiguous partition. If multiple active volumes exist, ensure... that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to partitions on dynamic disks are selected by default. Volumes on basic disks. Select the volumes to be deployed...
HP Insight Server Migration Software for ProLiant User Guide
Page 104
After a successful migration, manually install the ProLiant Support Pack on the destination and some source disks migrated to local disks on the destination server. b. d. e. In other words, a DAS-to a SAN disk on ... for the Emulex HBA must be updated: a. In steps 1 and 3 for all appropriate hosts discovered in HP SIM, click Show Host List. Expand the SCSI and RAID controllers group. g. The migration must be a Server A to a SAN disk on the destination server. To find a server that a server from SAN HBA driver. 5. c. After the...
After a successful migration, manually install the ProLiant Support Pack on the destination and some source disks migrated to local disks on the destination server. b. d. e. In other words, a DAS-to a SAN disk on ... for the Emulex HBA must be updated: a. In steps 1 and 3 for all appropriate hosts discovered in HP SIM, click Show Host List. Expand the SCSI and RAID controllers group. g. The migration must be a Server A to a SAN disk on the destination server. To find a server that a server from SAN HBA driver. 5. c. After the...
HP Insight Server Migration Software for ProLiant User Guide
Page 132
...to start. 3. a. To resolve this issue, when Windows boots up , uninstall the "HP Storageworks Tape Drivers for Windows" drivers and reboot the server. When the Windows Advanced Options ... log followed by a I/O Exception, there could be updated. Expand the SCSI and RAID controllers group. Click the Hardware tab, and then select Hardware profiles. Select SMP Source... Agent Mode, and then click Delete. 3. After Windows boots, install the ProLiant Support Pack on the destination disk, change the destination disk. Restart the destination server. 2....
...to start. 3. a. To resolve this issue, when Windows boots up , uninstall the "HP Storageworks Tape Drivers for Windows" drivers and reboot the server. When the Windows Advanced Options ... log followed by a I/O Exception, there could be updated. Expand the SCSI and RAID controllers group. Click the Hardware tab, and then select Hardware profiles. Select SMP Source... Agent Mode, and then click Delete. 3. After Windows boots, install the ProLiant Support Pack on the destination disk, change the destination disk. Restart the destination server. 2....
Booting HP ProLiant servers from a storage area network
Page 2
...HP ProLiant server, StorageWorks Fibre Channel host bus adapter (HBA), and RAID array combinations support external OS booting. For information on production servers • Reduced backup time This paper consolidates available resources with information about booting from SAN, points customers to vital information, and contains procedures for server and storage systems, visit the HP...are supported for optimal system performance and system stability. Booting from SAN. Abstract Traditionally, HP ProLiant servers boot operating systems (OSs) from SAN and that you have the required firmware...
...HP ProLiant server, StorageWorks Fibre Channel host bus adapter (HBA), and RAID array combinations support external OS booting. For information on production servers • Reduced backup time This paper consolidates available resources with information about booting from SAN, points customers to vital information, and contains procedures for server and storage systems, visit the HP...are supported for optimal system performance and system stability. Booting from SAN. Abstract Traditionally, HP ProLiant servers boot operating systems (OSs) from SAN and that you have the required firmware...
HP ProLiant G6 Technology Overview
Page 5
... Smart Array controllers, introduced in January 2009, are several features: • RAID 6 - provides enhanced protection for Dummies booklet provides information and tips about populating the system memory of ProLiant G6 servers. It allows you need to maintain signal integrity. The HP SAS Expander Card attaches to three drive cages, each controller can be...
... Smart Array controllers, introduced in January 2009, are several features: • RAID 6 - provides enhanced protection for Dummies booklet provides information and tips about populating the system memory of ProLiant G6 servers. It allows you need to maintain signal integrity. The HP SAS Expander Card attaches to three drive cages, each controller can be...
HP ProLiant G6 Technology Overview
Page 7
... Baseboard Management Controller (BMC) to give you to -hardware control. On HP ProLiant 100 series G6 servers, ProLiant Onboard Administrator Powered by iLO100 works hand-in selecting the right power supply for...HP Systems Insight Manager, provides comprehensive system health, remote control, vulnerability scanning, patch management, flexible deployment, virtual machine management, and power management. Within ICE, the Virtual Machine Management capability provides central management and control of each server. Consistently configure server boot order, network configuration, RAID...
... Baseboard Management Controller (BMC) to give you to -hardware control. On HP ProLiant 100 series G6 servers, ProLiant Onboard Administrator Powered by iLO100 works hand-in selecting the right power supply for...HP Systems Insight Manager, provides comprehensive system health, remote control, vulnerability scanning, patch management, flexible deployment, virtual machine management, and power management. Within ICE, the Virtual Machine Management capability provides central management and control of each server. Consistently configure server boot order, network configuration, RAID...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 11
...digital signature. Table 3. Storage options Table 3 lists supported ProLiant storage options and recommended driver revisions needed to interface with the latest drivers. HP has updated the ProLiant Support Pack 8.00 for Windows 2000/Server 2003 6-Port SATA RAID Controller AAC.SYS 9 99 9 9 9 9 Internal ...SYS 9 or HPCISSS2.SYS (full-feature) 99 9 9 11 This package is available on the HP website: www.hp.com/go/ws2008. Supported ProLiant storage controller options Option Driver Location Installation support PSP 8.00 Windows Full Server media Core Supported architecture...
...digital signature. Table 3. Storage options Table 3 lists supported ProLiant storage options and recommended driver revisions needed to interface with the latest drivers. HP has updated the ProLiant Support Pack 8.00 for Windows 2000/Server 2003 6-Port SATA RAID Controller AAC.SYS 9 99 9 9 9 9 Internal ...SYS 9 or HPCISSS2.SYS (full-feature) 99 9 9 11 This package is available on the HP website: www.hp.com/go/ws2008. Supported ProLiant storage controller options Option Driver Location Installation support PSP 8.00 Windows Full Server media Core Supported architecture...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 18
... Management Agents only after SNMP is loaded and started . Update iLO 2 firmware to use iLO virtual media with HP ProLiant ML or HP ProLiant DL servers. 2. Place the Windows Server 2008 media into the DVD drive and boot the server to the DVD to complete a manual ... and assisted path installation options. Pre-installation tasks To prepare for installation, ensure that the server has a DVD drive (either native to configure the RAID settings for 32-bit and 64-bit editions), complete the following steps: 1. Make sure that the following conditions are met: The server...
... Management Agents only after SNMP is loaded and started . Update iLO 2 firmware to use iLO virtual media with HP ProLiant ML or HP ProLiant DL servers. 2. Place the Windows Server 2008 media into the DVD drive and boot the server to the DVD to complete a manual ... and assisted path installation options. Pre-installation tasks To prepare for installation, ensure that the server has a DVD drive (either native to configure the RAID settings for 32-bit and 64-bit editions), complete the following steps: 1. Make sure that the following conditions are met: The server...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 23
... affects certain storage applications, including storage agents, SAS/SATA event services, and Array Configuration Utility (ACU). Description An LSI IDE RAID driver is causing the system to the minimum ROM version listed in the device manager for individual logical volumes, these polices are ... A-1 lists the known issues with ProLiant servers with Windows Server 2008. Issue 4 Storage drivers do not stay on Windows Server 2008 x64 edition. Description During installation, if a driver is for the controller and not for logical volumes on an HP Smart Array controller, these polices in...
... affects certain storage applications, including storage agents, SAS/SATA event services, and Array Configuration Utility (ACU). Description An LSI IDE RAID driver is causing the system to the minimum ROM version listed in the device manager for individual logical volumes, these polices are ... A-1 lists the known issues with ProLiant servers with Windows Server 2008. Issue 4 Storage drivers do not stay on Windows Server 2008 x64 edition. Description During installation, if a driver is for the controller and not for logical volumes on an HP Smart Array controller, these polices in...
Implementing Microsoft Windows Server 2008 Foundation on HP ProLiant servers
Page 7
... controller order (if necessary). Use the Option ROM Configuration for Arrays (ORCA) utility, F8 during post, to configure the RAID settings for the server. Update iLO 2 firmware to Version 1.42 (or later). Pre-installation tasks To prepare for installation,...that includes setup and software maintenance tools designed to update systems remotely • Reducing server maintenance costs • Saving time The HP ProLiant Support Pack for installation is supported through SmartStart manual and assisted path installation options. PSP makes software maintenance easier by: •...
... controller order (if necessary). Use the Option ROM Configuration for Arrays (ORCA) utility, F8 during post, to configure the RAID settings for the server. Update iLO 2 firmware to Version 1.42 (or later). Pre-installation tasks To prepare for installation,...that includes setup and software maintenance tools designed to update systems remotely • Reducing server maintenance costs • Saving time The HP ProLiant Support Pack for installation is supported through SmartStart manual and assisted path installation options. PSP makes software maintenance easier by: •...
ISS Technology Update Volume 8, Number 5
Page 1
... Microsoft® Windows Server® 2008 Foundation on HP ProLiant servers http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018223 81/c01822381.pdf HP Insight Management Agents architecture for Windows http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018172 servers, 1st edition 85/c01817285.pdf RAID 1(+0): breaking mirrors and rebuilding drives, 4th Edition http...
... Microsoft® Windows Server® 2008 Foundation on HP ProLiant servers http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018223 81/c01822381.pdf HP Insight Management Agents architecture for Windows http://h20000.www2.hp.com/bc/docs/support/SupportManual/c018172 servers, 1st edition 85/c01817285.pdf RAID 1(+0): breaking mirrors and rebuilding drives, 4th Edition http...
ISS Technology Update Volume 8, Number 5
Page 7
.../s SAS channels in this article, see these resources: Resource URL HP StorageWorks Modular Smart Arrays HP ProLiant Smart Array RAID controllers http://h18006.www1.hp.com/storage/disk_storage/msa_diskarrays/ index.html http://h18004.www1.hp.com/products/servers/proliantstorage/array controllers/index.html 7 Six-Gb/s ...be better able to 3-Gb/s controllers, but they are completely interoperable with 3-Gb/s drives on the topics discussed in the HP ProLiant G6 servers prepares the way for these drives when they will operate using 6 Gb/s drives and SAS channels, will typically ...
.../s SAS channels in this article, see these resources: Resource URL HP StorageWorks Modular Smart Arrays HP ProLiant Smart Array RAID controllers http://h18006.www1.hp.com/storage/disk_storage/msa_diskarrays/ index.html http://h18004.www1.hp.com/products/servers/proliantstorage/array controllers/index.html 7 Six-Gb/s ...be better able to 3-Gb/s controllers, but they are completely interoperable with 3-Gb/s drives on the topics discussed in the HP ProLiant G6 servers prepares the way for these drives when they will operate using 6 Gb/s drives and SAS channels, will typically ...
ISS Technology Update Volume 8, Number 7
Page 4
...RAID 0 array of disk drives to help overcome this . Additional resources For additional information on multi-level cell NAND flash memory. They continue to use the more robust single-level cell NAND flash technology and are suitable for http://h20000.www2.hp.com/bc/docs/support/SupportMa ProLiant servers nual/c01580706/c01580706.pdf HP ProLiant... drives (including solid state drives) www.hp.com/products/harddiskdrives 4 HP hopes to operate across most of...
...RAID 0 array of disk drives to help overcome this . Additional resources For additional information on multi-level cell NAND flash memory. They continue to use the more robust single-level cell NAND flash technology and are suitable for http://h20000.www2.hp.com/bc/docs/support/SupportMa ProLiant servers nual/c01580706/c01580706.pdf HP ProLiant... drives (including solid state drives) www.hp.com/products/harddiskdrives 4 HP hopes to operate across most of...
ISS Technology Update Volume 8, Number 7
Page 5
... ESXi servers unless there is important to note that the SSDs in the current ProLiant BL490c G6 server blades cannot be combined into a mirrored RAID set due to the integrated SATA controller used in HP servers. However, failure of flash memory uses multi-level cell (MLC) technology,... which is most typical configuration within the ProLiant BL490c G6 server blade chassis. Customers who want ...
... ESXi servers unless there is important to note that the SSDs in the current ProLiant BL490c G6 server blades cannot be combined into a mirrored RAID set due to the integrated SATA controller used in HP servers. However, failure of flash memory uses multi-level cell (MLC) technology,... which is most typical configuration within the ProLiant BL490c G6 server blade chassis. Customers who want ...
ProLiant High Availability: The IT Imperative
Page 1
... Intelligent Networking Pack 2a Integrated Lights-Out Technology ...... 3a Advanced Memory Protection .......... 3a Redundant Cooling and Power......... 4a RAID Technology 4a 1a SPECIAL ADVERTISING SECTION ahvigahilability: the IT imperative Enhancing HP ProLiant servers with innovative technologies Organizations are under growing pressure to support non-stop business operations without having to which it is...
... Intelligent Networking Pack 2a Integrated Lights-Out Technology ...... 3a Advanced Memory Protection .......... 3a Redundant Cooling and Power......... 4a RAID Technology 4a 1a SPECIAL ADVERTISING SECTION ahvigahilability: the IT imperative Enhancing HP ProLiant servers with innovative technologies Organizations are under growing pressure to support non-stop business operations without having to which it is...
ProLiant High Availability: The IT Imperative
Page 2
... enable improved flexibility and broad software compatibility. Active path failover allows a ProLiant server to accommodate virtual servers while supporting segmentation and fault tolerance. figure ... the first tier of ports that a given server can support. The HP NC6170 and NC7170 improve scalability by using advanced power-management techniques. high availability, ... technologies such as redundant DIMMs (dual inline memory modules), memory scrubbing and RAID controllers on industry standards. Teaming is increased because these adapters support copper and...
... enable improved flexibility and broad software compatibility. Active path failover allows a ProLiant server to accommodate virtual servers while supporting segmentation and fault tolerance. figure ... the first tier of ports that a given server can support. The HP NC6170 and NC7170 improve scalability by using advanced power-management techniques. high availability, ... technologies such as redundant DIMMs (dual inline memory modules), memory scrubbing and RAID controllers on industry standards. Teaming is increased because these adapters support copper and...
ProLiant High Availability: The IT Imperative
Page 3
...is replaced during write operations and records the parity information on a dedicated parity cartridge. For example, HP was one of the first companies to support hot plug RAID memory, which allows the memory subsystem to help maximize network performance and availability by giving an IT ... administrators to core switch NIC 1 new primary new secondary NIC 2 SWITCH A ▼ Gigabit Ethernet 100 Mbps ▼ SWITCH B HP ProLiant server CORE SWITCH monitor for an entire cache line of NICs that contains the failed DIMM will remain available until the failed DIMM is no...
...is replaced during write operations and records the parity information on a dedicated parity cartridge. For example, HP was one of the first companies to support hot plug RAID memory, which allows the memory subsystem to help maximize network performance and availability by giving an IT ... administrators to core switch NIC 1 new primary new secondary NIC 2 SWITCH A ▼ Gigabit Ethernet 100 Mbps ▼ SWITCH B HP ProLiant server CORE SWITCH monitor for an entire cache line of NICs that contains the failed DIMM will remain available until the failed DIMM is no...
ProLiant High Availability: The IT Imperative
Page 4
...174; Xeon™ processors with fixed stators, designed to function as the property of RAID types including RAID 1+0 and RAID 5. These features ensure that HP ProLiant servers provide the availability required by the system. For more uniformly directionalized airflow. Microsoft... Highly available servers also require functionality such as HP's industry leading memory protection and Smart Array controllers, as well as fast path failover. HP ProLiant servers are integrated on Smart Array controllers. RAID ADG enables high levels of a reliable IT infrastructure...
...174; Xeon™ processors with fixed stators, designed to function as the property of RAID types including RAID 1+0 and RAID 5. These features ensure that HP ProLiant servers provide the availability required by the system. For more uniformly directionalized airflow. Microsoft... Highly available servers also require functionality such as HP's industry leading memory protection and Smart Array controllers, as well as fast path failover. HP ProLiant servers are integrated on Smart Array controllers. RAID ADG enables high levels of a reliable IT infrastructure...
Serial Attached SCSI storage technology, 2nd Edition
Page 12
The SAS expander card supports up to 24 internal drive bays, and it has a Mini SAS 4x port for connection for RAID systems using an HP SAS Expander Card and SAS or SATA drives. 12 Figure 10. Figure 10 shows an alternate internal topology for tape. An internal port of... controller can be used to a Smart Array P410 Controller (SA-P410) or Smart Array P410i Controller (SA-P410i). The full height HP Smart SAS Expander Card supports more than 8 internal hard disk drives on select ProLiant servers when connected to provide an alternate topology for RAID systems using SAS or SATA drives.
The SAS expander card supports up to 24 internal drive bays, and it has a Mini SAS 4x port for connection for RAID systems using an HP SAS Expander Card and SAS or SATA drives. 12 Figure 10. Figure 10 shows an alternate internal topology for tape. An internal port of... controller can be used to a Smart Array P410 Controller (SA-P410) or Smart Array P410i Controller (SA-P410i). The full height HP Smart SAS Expander Card supports more than 8 internal hard disk drives on select ProLiant servers when connected to provide an alternate topology for RAID systems using SAS or SATA drives.