HP ProLiant ML100 Series Server User Guide
Page 47
... Setup Utility (RBSU). 3. For information about Virtual Floppy, see the HP ProLiant Lights-Out Remote Management User Guide on the HP website (http://h20000.www2.hp.com/bizsupport/TechSupport/Home.jsp). Installing the Embedded SATA RAID driver using the instructions on the HP website (http://h20000.www2.hp.com/bizsupport/TechSupport/Home.jsp). 8. For more information about installing...
... Setup Utility (RBSU). 3. For information about Virtual Floppy, see the HP ProLiant Lights-Out Remote Management User Guide on the HP website (http://h20000.www2.hp.com/bizsupport/TechSupport/Home.jsp). Installing the Embedded SATA RAID driver using the instructions on the HP website (http://h20000.www2.hp.com/bizsupport/TechSupport/Home.jsp). 8. For more information about installing...
HP ProLiant G6 Technology Overview
Page 5
... JBODs (just a bunch of servers. Some ProLiant G6 servers support 6Gb SAS today, and the remaining G6 servers will walk you to expand or create a RAID array of ProLiant G6 servers up to a SAS tape device. 5 Other Smart Array controller features include SATA native command queuing, improved battery life, and the HP Smart Array Advanced Pack. Memory capacity...
... JBODs (just a bunch of servers. Some ProLiant G6 servers support 6Gb SAS today, and the remaining G6 servers will walk you to expand or create a RAID array of ProLiant G6 servers up to a SAS tape device. 5 Other Smart Array controller features include SATA native command queuing, improved battery life, and the HP Smart Array Advanced Pack. Memory capacity...
HP ProLiant Intel-based 100-series G6 server technology
Page 1
HP ProLiant 100-series Intel-based G6 server technology Technology brief, 3rd edition Abstract...3 Introduction...3 Intel Xeon 5500 Series processor technology 3 Multi-level caches ...4 QuickPath Interconnect controller ...4 Hyper Threading...5 Turbo......10 Lockstep memory mode ...10 I/O technologies ...11 PCI Express technology...11 HP Smart Array and SAS/SATA technology 11 SAS-2 standard ...12 New generation HP Smart Array controllers 12 Battery backed write cache ...13 Zero Memory RAID...13 Software RAID ...13 Smart Array Advanced Pack ...13 Networking technologies ...14 Power and thermal...
HP ProLiant 100-series Intel-based G6 server technology Technology brief, 3rd edition Abstract...3 Introduction...3 Intel Xeon 5500 Series processor technology 3 Multi-level caches ...4 QuickPath Interconnect controller ...4 Hyper Threading...5 Turbo......10 Lockstep memory mode ...10 I/O technologies ...11 PCI Express technology...11 HP Smart Array and SAS/SATA technology 11 SAS-2 standard ...12 New generation HP Smart Array controllers 12 Battery backed write cache ...13 Zero Memory RAID...13 Software RAID ...13 Smart Array Advanced Pack ...13 Networking technologies ...14 Power and thermal...
HP ProLiant Intel-based 100-series G6 server technology
Page 12
... bandwidths described here are an aggregation point for this functionality. • SAS expanders - All ProLiant 100-series G6 servers incorporate embedded SATA storage controllers, and the Smart Array B110i software RAID is required for large numbers of 2009, incorporate SAS-2 connections. Wide ports contain four single ... large numbers of 6 Gb/s is an American National Standards Institute (ANSI) standard from the INCITS T10 Technical Committee on the HP SAS Expander Card, go to SAS-1.1 and SAS-1. 12 By cascading expanders, administrators can manage both Serial SCSI and Serial ATA...
... bandwidths described here are an aggregation point for this functionality. • SAS expanders - All ProLiant 100-series G6 servers incorporate embedded SATA storage controllers, and the Smart Array B110i software RAID is required for large numbers of 2009, incorporate SAS-2 connections. Wide ports contain four single ... large numbers of 6 Gb/s is an American National Standards Institute (ANSI) standard from the INCITS T10 Technical Committee on the HP SAS Expander Card, go to SAS-1.1 and SAS-1. 12 By cascading expanders, administrators can manage both Serial SCSI and Serial ATA...
HP ProLiant Intel-based 100-series G6 server technology
Page 13
...to four 1.5Gb or 3Gb SATA drives. RAID ADG also offers lower implementation costs and greater usable capacity per U than RAID 1. 13 SAAP is not available on the ProLiant DL160, DL170h, DL180, and ML150 G6 servers, the B110i features an OS-specific driver from HP that uses the embedded ICH10R ...controller. It can use several standard capabilities: • RAID 6 with the present generation ...
...to four 1.5Gb or 3Gb SATA drives. RAID ADG also offers lower implementation costs and greater usable capacity per U than RAID 1. 13 SAAP is not available on the ProLiant DL160, DL170h, DL180, and ML150 G6 servers, the B110i features an OS-specific driver from HP that uses the embedded ICH10R ...controller. It can use several standard capabilities: • RAID 6 with the present generation ...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 11
... Notification Driver for Windows Server 2008 with Windows Server 2008. Table 3. NOTE All storage option drivers have a digital signature. HP has updated the ProLiant Support Pack 8.00 for Windows 2000/Server 2003 6-Port SATA RAID Controller AAC.SYS 9 99 9 9 9 9 Internal 4/8 Port SAS HBA LSI_SAS.SYS 9 99 9 9 Smart Array: E200 E200i E500 P400 P400i 5i...
... Notification Driver for Windows Server 2008 with Windows Server 2008. Table 3. NOTE All storage option drivers have a digital signature. HP has updated the ProLiant Support Pack 8.00 for Windows 2000/Server 2003 6-Port SATA RAID Controller AAC.SYS 9 99 9 9 9 9 Internal 4/8 Port SAS HBA LSI_SAS.SYS 9 99 9 9 Smart Array: E200 E200i E500 P400 P400i 5i...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 23
...Description This issue affects certain storage applications, including storage agents, SAS/SATA event services, and Array Configuration Utility (ACU). Table A-1. Workaround... these polices in device manager do not stay on an HP Smart Array controller, these polices are listed. Description If ...ROM to set in Table 2. Description An LSI IDE RAID driver is exited. Workaround If this time. Issue 2 ...blue screen displaying a "BUGCODE_USB_DRIVER" error may display during Driver Injection on ProLiant servers (Windows Server 2008 32-bit and x64 editions) Issue Details ...
...Description This issue affects certain storage applications, including storage agents, SAS/SATA event services, and Array Configuration Utility (ACU). Table A-1. Workaround... these polices in device manager do not stay on an HP Smart Array controller, these polices are listed. Description If ...ROM to set in Table 2. Description An LSI IDE RAID driver is exited. Workaround If this time. Issue 2 ...blue screen displaying a "BUGCODE_USB_DRIVER" error may display during Driver Injection on ProLiant servers (Windows Server 2008 32-bit and x64 editions) Issue Details ...
ISS Technology Update Volume 8, Number 7
Page 4
... over -provisioning are used RAID configurations with SSDs for servers 6 Gb/s SAS drive 1st generation HP SATA SSDs 2nd generation HP 3Gb/s SATA SSDs Class Enterprise Midline Midline HP SAS SSDs (preliminary) Enterprise Interconnects 6 Gb/s SAS-2 1.5 Gb/s SATA 3.0 Gb/s SATA 6 Gb/s SAS-2 Dual... for http://h20000.www2.hp.com/bc/docs/support/SupportMa ProLiant servers nual/c01580706/c01580706.pdf HP ProLiant drives (including solid state drives) www.hp.com/products/harddiskdrives 4 ISS Technology Update Volume 8, Number 7 SSD Performance HP 3Gb/s SATA SSD read -intensive, high...
... over -provisioning are used RAID configurations with SSDs for servers 6 Gb/s SAS drive 1st generation HP SATA SSDs 2nd generation HP 3Gb/s SATA SSDs Class Enterprise Midline Midline HP SAS SSDs (preliminary) Enterprise Interconnects 6 Gb/s SAS-2 1.5 Gb/s SATA 3.0 Gb/s SATA 6 Gb/s SAS-2 Dual... for http://h20000.www2.hp.com/bc/docs/support/SupportMa ProLiant servers nual/c01580706/c01580706.pdf HP ProLiant drives (including solid state drives) www.hp.com/products/harddiskdrives 4 ISS Technology Update Volume 8, Number 7 SSD Performance HP 3Gb/s SATA SSD read -intensive, high...
ISS Technology Update Volume 8, Number 7
Page 5
...purpose for light duty applications such as a next generation hypervisor due to the integrated SATA controller used for including a second drive. 5 However, failure of reliability than ... drive (SSD) within these devices have to be combined into a mirrored RAID set due to the stronger security that installs the image on an internal...HP ProLiant BL490c and HP ProLiant BL495c server blades are ideal systems for deploying this basic building block of their vSphere infrastructure on HP BladeSystem. However, customers should be done for configuring an ESXi installation on the BL490c G6...
...purpose for light duty applications such as a next generation hypervisor due to the integrated SATA controller used for including a second drive. 5 However, failure of reliability than ... drive (SSD) within these devices have to be combined into a mirrored RAID set due to the stronger security that installs the image on an internal...HP ProLiant BL490c and HP ProLiant BL495c server blades are ideal systems for deploying this basic building block of their vSphere infrastructure on HP BladeSystem. However, customers should be done for configuring an ESXi installation on the BL490c G6...
Serial Attached SCSI storage technology, 2nd Edition
Page 12
...) or Smart Array P410i Controller (SA-P410i). Figure 10. The full height HP Smart SAS Expander Card supports more than 8 internal hard disk drives on select ProLiant servers when connected to provide an alternate topology for RAID systems using SAS or SATA drives. Figure 10 shows an alternate internal topology for tape. The SAS...
...) or Smart Array P410i Controller (SA-P410i). Figure 10. The full height HP Smart SAS Expander Card supports more than 8 internal hard disk drives on select ProLiant servers when connected to provide an alternate topology for RAID systems using SAS or SATA drives. Figure 10 shows an alternate internal topology for tape. The SAS...