HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 16
Information for the HP ProLiant ML150 G6 server. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés. These parts ... require that an authorized service provider replace the part. 2 Illustrated parts catalog This chapter provides the illustrated parts breakdown and spare parts lists for contacting HP is also provided. HOT PLUG 519734-001 Mandatory1 5 SPS-BAFFLE 519741-001 Mandatory1 6 SPS-PANEL, SIDE 519729-001 Mandatory1 1Mandatory-Parts for customer self repair...
Information for the HP ProLiant ML150 G6 server. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés. These parts ... require that an authorized service provider replace the part. 2 Illustrated parts catalog This chapter provides the illustrated parts breakdown and spare parts lists for contacting HP is also provided. HOT PLUG 519734-001 Mandatory1 5 SPS-BAFFLE 519741-001 Mandatory1 6 SPS-PANEL, SIDE 519729-001 Mandatory1 1Mandatory-Parts for customer self repair...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 24
... wiring board. Before installing a new component, review its specifications to the "Electrostatic Discharge Information" section for the HP ProLiant ML150 G6 server. Removal and replacement procedures 24 Hardware configuration information WARNING: Only authorized technicians trained by HP should attempt to make repairs at the component level or to make modifications to step b, etc.). Non-hot...
... wiring board. Before installing a new component, review its specifications to the "Electrostatic Discharge Information" section for the HP ProLiant ML150 G6 server. Removal and replacement procedures 24 Hardware configuration information WARNING: Only authorized technicians trained by HP should attempt to make repairs at the component level or to make modifications to step b, etc.). Non-hot...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 42
.../E5510/E5530/E5540 series processors CAUTION: To prevent possible server malfunction in 2P systems, ensure that both processors are the same type (series). Processor The HP ProLiant ML150 G6 Server supports single (1P)-
.../E5510/E5530/E5540 series processors CAUTION: To prevent possible server malfunction in 2P systems, ensure that both processors are the same type (series). Processor The HP ProLiant ML150 G6 Server supports single (1P)-
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 47
Memory The HP ProLiant ML150 G6 server provides 12 DIMM slots that support up to 48 GB of system memory. buffered DIMM. Removal and replacement procedures 47 Figure 3-25 DIMM slots ...
Memory The HP ProLiant ML150 G6 server provides 12 DIMM slots that support up to 48 GB of system memory. buffered DIMM. Removal and replacement procedures 47 Figure 3-25 DIMM slots ...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 88
... describing the key components (including connectors), switches, and LED indicators located on the front and rear panels, the system board, and hard drives of the HP ProLiant ML150 G6 Server. Front and Rear Panel Components, Switches, and Indicators Figure 5-1 Front and Rear Panel Components, Switches, and Indicators Table 5-1 Front and Rear Panel Components Item...
... describing the key components (including connectors), switches, and LED indicators located on the front and rear panels, the system board, and hard drives of the HP ProLiant ML150 G6 Server. Front and Rear Panel Components, Switches, and Indicators Figure 5-1 Front and Rear Panel Components, Switches, and Indicators Table 5-1 Front and Rear Panel Components Item...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 94
Specifications are provided for the HP ProLiant ML150 G6 server. 6 Physical and Operating Specifications This chapter provides physical and operating specifications for the following: • System unit • Software • Physical • Environmental • ...
Specifications are provided for the HP ProLiant ML150 G6 server. 6 Physical and Operating Specifications This chapter provides physical and operating specifications for the following: • System unit • Software • Physical • Environmental • ...
HP ProLiant ML150 G6 Server Maintenance and Service Guide
Page 99
...: 1GB, 2GB 1066MHz / 1333MHz 1Gb, 2Gb x4 and x8 for Registered and 2Gb x8 and x16 for unbuffered. For systems configured with ECC Processor The HP ProLiant ML150 G6 server provides two Intel LGA1366 processor sockets that support Intel Nehalem Dual-Core E5502 and Intel Nehalem Quad-Core E5504/E5506/E5520/E5530/E5540 processors.
...: 1GB, 2GB 1066MHz / 1333MHz 1Gb, 2Gb x4 and x8 for Registered and 2Gb x8 and x16 for unbuffered. For systems configured with ECC Processor The HP ProLiant ML150 G6 server provides two Intel LGA1366 processor sockets that support Intel Nehalem Dual-Core E5502 and Intel Nehalem Quad-Core E5504/E5506/E5520/E5530/E5540 processors.
HP ProLiant ML 150 G6 Processor Installation Card
Page 1
...should be reused, carefully place the heatsink in a position where the base (processor contact area) will not come in the HP ProLiant ML150 G6 Server. If the heatsink is correctly positioned with the orientation notch on the socket and that the pins are set forth in ...Remove the air baffle by pulling up CD. Figure 4 Installing a processor After you are knowledgeable of the processor socket. HP ProLiant ML150 G6 Server Processor Option kit Installation Instructions Overview This document contains instructions for installing the optional Processor Option Kit in contact with foreign...
...should be reused, carefully place the heatsink in a position where the base (processor contact area) will not come in the HP ProLiant ML150 G6 Server. If the heatsink is correctly positioned with the orientation notch on the socket and that the pins are set forth in ...Remove the air baffle by pulling up CD. Figure 4 Installing a processor After you are knowledgeable of the processor socket. HP ProLiant ML150 G6 Server Processor Option kit Installation Instructions Overview This document contains instructions for installing the optional Processor Option Kit in contact with foreign...
HP ProLiant ML150 G6 server Installation Sheet
Page 1
... screen, and then press the Pause key to the HP ProLiant ML150 G6 Server Maintenance and Service Guide available on the HP website: http://www.hp.com d. To determine the BIOS version: a. c. If necessary, update the BIOS (refer to halt screen movement. b. Verify...before removing or replacing non-hot-pluggable hard disk drives, DIMMs, or processors. HP ProLiant ML150 G6 Server Installation Sheet Part number: 501527-001 March 2009 First Edition Configuring the server Refer to the HP ProLiant ML150 G6 Server Easy set-up the server. Power up CD contents for this installation sheet...
... screen, and then press the Pause key to the HP ProLiant ML150 G6 Server Maintenance and Service Guide available on the HP website: http://www.hp.com d. To determine the BIOS version: a. c. If necessary, update the BIOS (refer to halt screen movement. b. Verify...before removing or replacing non-hot-pluggable hard disk drives, DIMMs, or processors. HP ProLiant ML150 G6 Server Installation Sheet Part number: 501527-001 March 2009 First Edition Configuring the server Refer to the HP ProLiant ML150 G6 Server Easy set-up the server. Power up CD contents for this installation sheet...
HP ProLiant ML100 Series Server User Guide
Page 1
HP ProLiant ML100 Series Server User Guide For HP ProLiant ML110 G6 Servers and HP ProLiant ML150 G6 Servers Part Number 501528-004 February 2010 (Fourth Edition)
HP ProLiant ML100 Series Server User Guide For HP ProLiant ML110 G6 Servers and HP ProLiant ML150 G6 Servers Part Number 501528-004 February 2010 (Fourth Edition)
HP ProLiant ML100 Series Server User Guide
Page 17
Power up to four hard drives and the HP ProLiant ML150 G6 Server support up the server (on page 7). For ML110 G6 servers, slide the server back into the rack. 15. SAS and SATA hard drive options The HP ProLiant ML110 G6 Server supports up to eight hard drives: • SATA hard drives ...only with the embedded SATA controller • SAS or SATA hard drives with an optional storage controller. See the server installation sheet on the HP website (http://www.hp.com/go /bizsupport...
Power up to four hard drives and the HP ProLiant ML150 G6 Server support up the server (on page 7). For ML110 G6 servers, slide the server back into the rack. 15. SAS and SATA hard drive options The HP ProLiant ML110 G6 Server supports up to eight hard drives: • SATA hard drives ...only with the embedded SATA controller • SAS or SATA hard drives with an optional storage controller. See the server installation sheet on the HP website (http://www.hp.com/go /bizsupport...
HP ProLiant ML100 Series Server User Guide
Page 30
o Extend the server from the rack. 4. For ML150 G6 servers, do not operate the server unless all PCI slots have either an expansion slot cover or an expansion board installed. Hardware options installation 30 Remove the access panel (on page 8). Open the slot cover retainer: o HP ProLiant ML110 G6 server o HP ProLiant ML150 G6 server CAUTION: To prevent improper cooling and thermal damage, do one of the following: o Unlock and remove the bezel ("Remove the tower bezel (ML150 G6 servers)" on page 7). 5. 3.
o Extend the server from the rack. 4. For ML150 G6 servers, do not operate the server unless all PCI slots have either an expansion slot cover or an expansion board installed. Hardware options installation 30 Remove the access panel (on page 8). Open the slot cover retainer: o HP ProLiant ML110 G6 server o HP ProLiant ML150 G6 server CAUTION: To prevent improper cooling and thermal damage, do one of the following: o Unlock and remove the bezel ("Remove the tower bezel (ML150 G6 servers)" on page 7). 5. 3.
HP ProLiant Intel-based 100-series G6 server technology
Page 3
...implemented in multiple sizes to its dedicated memory provide a total bandwidth of this writing, the Intel-based 100-series G6 servers include the ProLiant DL120, DL160, DL180, ML110, ML150, DL170h, DL2x170h, and DL4x170h. Characterized by Lights-Out 100i (LO 100i) • I/O technologies such as .../c00164255.pdf. 3 The processors include an integrated memory controller and Intel QuickPath technology to reduce electrical leakage. Introduction HP ProLiant G6 servers have been the focus of this technology brief. The Xeon 5500 Series microarchitecture is built on hafnium-based, ...
...implemented in multiple sizes to its dedicated memory provide a total bandwidth of this writing, the Intel-based 100-series G6 servers include the ProLiant DL120, DL160, DL180, ML110, ML150, DL170h, DL2x170h, and DL4x170h. Characterized by Lights-Out 100i (LO 100i) • I/O technologies such as .../c00164255.pdf. 3 The processors include an integrated memory controller and Intel QuickPath technology to reduce electrical leakage. Introduction HP ProLiant G6 servers have been the focus of this technology brief. The Xeon 5500 Series microarchitecture is built on hafnium-based, ...
HP ProLiant Intel-based 100-series G6 server technology
Page 13
...key for the B110i SATA Software RAID, download the B110i user guide at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01706551/c01706551.pdf Smart Array Advanced Pack HP Smart Array Advanced Pack (SAAP) firmware provides advanced functionality within Smart Array controllers. ZMR does ... firmware stack. During the expansion, the BBWC preserves data and logical structures on the ProLiant DL160, DL170h, DL180, and ML150 G6 servers, the B110i features an OS-specific driver from HP that maintains the user data and RAID configuration. It can be available for capacity expansion...
...key for the B110i SATA Software RAID, download the B110i user guide at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01706551/c01706551.pdf Smart Array Advanced Pack HP Smart Array Advanced Pack (SAAP) firmware provides advanced functionality within Smart Array controllers. ZMR does ... firmware stack. During the expansion, the BBWC preserves data and logical structures on the ProLiant DL160, DL170h, DL180, and ML150 G6 servers, the B110i features an OS-specific driver from HP that maintains the user data and RAID configuration. It can be available for capacity expansion...
HP ProLiant Intel-based 100-series G6 server technology
Page 28
... SAS and SATA technology Smart Array Advance Pack Smart Array controllers HP Network Adapters for ProLiant DL and ML Servers HP ProLiant 100-series Easy Set-up CDs HP ProLiant DL120 G6 Server HP ProLiant DL160 G6 Server HP ProLiant DL180 G6 Server HP ProLiant ML110 G6 Server HP ProLiant ML150 G6 Server HP ProLiant DL170h G6 Server overview HP ProLiant DL1000 G6 Multi Node Server HP ProLiant Onboard Administrator Powered by LO100 (remote management) ISS Technology Communications...
... SAS and SATA technology Smart Array Advance Pack Smart Array controllers HP Network Adapters for ProLiant DL and ML Servers HP ProLiant 100-series Easy Set-up CDs HP ProLiant DL120 G6 Server HP ProLiant DL160 G6 Server HP ProLiant DL180 G6 Server HP ProLiant ML110 G6 Server HP ProLiant ML150 G6 Server HP ProLiant DL170h G6 Server overview HP ProLiant DL1000 G6 Multi Node Server HP ProLiant Onboard Administrator Powered by LO100 (remote management) ISS Technology Communications...