HP Power Capping and Dynamic Power Capping for ProLiant servers technology brief, 1st edition
Page 20
... As Table 5 shows, if Dynamic Power Capping is applied the same circuit can be provisioned within same 7760 watts using Dynamic Power Capping review the peak power consumption of the servers in the group may be used to ensure that the selected power cap for those servers, especially if... when capping to peak power consumption using basic Power Capping Description Maximum possible power consumption for 8 DL380 G5 servers (based on HP Power Calculator) Maximum power consumption when capping to peak Power 3384 watts 3116 watts Savings in power capacity 268 watts Additional servers that...
... As Table 5 shows, if Dynamic Power Capping is applied the same circuit can be provisioned within same 7760 watts using Dynamic Power Capping review the peak power consumption of the servers in the group may be used to ensure that the selected power cap for those servers, especially if... when capping to peak power consumption using basic Power Capping Description Maximum possible power consumption for 8 DL380 G5 servers (based on HP Power Calculator) Maximum power consumption when capping to peak Power 3384 watts 3116 watts Savings in power capacity 268 watts Additional servers that...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 38
...problems, review the list of Known Issues below first to disk at shutdown. Drive Array Reports Valid Data Found in slots 1, 2, 4, 5, 7, or 8. Known issues The following is a list of this by executing the following error message may be displayed on a DL580 G5 server.... the following command before every shutdown: # swap -d Optionally, shutdown the system using these commands: # init 0 # halt Solaris stops responding on HP ProLiant DL580 G5 server Solaris may stop responding, or will respond poorly if a PCI-Express Controller is configured in PCIExpress slots 1, 2, 4, 5, 7, or 8...
...problems, review the list of Known Issues below first to disk at shutdown. Drive Array Reports Valid Data Found in slots 1, 2, 4, 5, 7, or 8. Known issues The following is a list of this by executing the following error message may be displayed on a DL580 G5 server.... the following command before every shutdown: # swap -d Optionally, shutdown the system using these commands: # init 0 # halt Solaris stops responding on HP ProLiant DL580 G5 server Solaris may stop responding, or will respond poorly if a PCI-Express Controller is configured in PCIExpress slots 1, 2, 4, 5, 7, or 8...